Search NASA⌕ Search

SEARCH · Search NASA

Results for “holographic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Holographic interferometry applied to symmetric aerodynamic models in a wind tunnel

The technique of holographic interferometry provides a means for noninvasive measurement of the air density distribution in the flow field in the vicinity of an aerodynamic model. A test of the applicability of this technique was the objective of this investigation. A holographic interferometer was installed in the 2- by 2-Foot Transonic Wind Tunnel at Ames Research Center. Several tests were conducted with this system on two axisymmetric models, one at subsonic and the other at supersonic speeds. Holograms were made of the flow field around the model for several test conditions. These holograms were reconstructed into interferograms in the laboratory. The fringe distribution (a measure of local densities) from a number of interferograms was digitized for subsequent data reduction. A computer program based on the Fourier transform technique was developed to convert the fringe distribution into a three-dimensional distribution of air density around the model. These results will be presented in this paper.

Perry, R. L.↗

A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

Decker, A. J.↗

Holographic gratings for spectrographic applications: Study of abberations

A computer program was developed that determines the optimum holographic grating recording parameters as a function of optical instrumental parameters and desired wavelength range for Seya-Namioka monochromator mountings. The theory and basic equations for designing holographic concave gratings such that minimization of aberrations of astigmatism or coma over a desired wavelength range may be achieved are presented. The computer program is described, including all of the subroutines. The input data, definitions of terms, and data card description are presented. An example is summarized for using the program and the output data is described in detail.

Bhatia, Manjit S.↗

Beam-modulation methods in quantitative and flow-visualization holographic interferometry

Heterodyne holographic interferometry and time-average holography with a frequency shifted reference beam are discussed. Both methods will be used for the measurement and visualization of internal transonic flows where the target facility is a flutter cascade. The background and experimental requirements for both methods are reviewed. Measurements using heterodyne holographic interferometry are presented. The performance of the laser required for time-average holography of time-varying transonic flows is discussed.

Decker, Arthur J.↗

Real-time laser holographic Interferometry for aerodynamics

Recent developments in thermoplastic recording holograms and advancements in automated image digitalization and analysis make real-time laser holographic interferometry feasible for two-dimensional flows such as airfoil flows. Typical airfoil measurements would include airfoil presssure distributions, wake and boundary layer profiles, and flow field density contours. This paper addresses some of the problems and requirements of a real-time laser holographic interferometer.

Lee, George↗

Transonic rotor flow-measurement technique using holographic interferometry

Holographic interferometry is used to record interferograms of the flow near a hovering transonic rotor blade. A pulsed ruby laser recorded 40 interferograms with a 2 ft dia. view field near the model rotor blade tip operating at a tip Mach number of 0.90. The experimental procedure is presented and example interferograms recorded in the rotor's tip path plane. In addition, a method currently being pursued to obtain quantitative flow information using computer assisted tomography (CAT) with the holographic interferogram data, is outlined.

Kittleson, John K.↗

Transonic flow visualization using holographic interferometry

An account is made of some of the applications of holographic interferometry to the visualization of transonic flows. In the case of the compressor shock visualization, the method is used regularly and has moved from being a research department invention to a design test tool. With the implementation of automatic processing and simple digitization systems, holographic vibrational analysis has also moved into routine nondestructive testing. The code verification interferograms were instructive, but the main turbomachinery interest is now in 3 dimensional flows. A major data interpretation effort will be required to compute tomographically the 3 dimensional flow around the leading or the trailing edges of a rotating blade row. The bolt on approach shows the potential application to current unsteady flows of interest. In particular that of the rotor passing and vortex interaction effects is experienced by the new generation of unducted fans. The turbocharger tests presents a new area for the application of holography.

Bryanston-Cross, Peter J.↗

Implementation of a digital optical matrix-vector multiplier using a holographic look-up table and residue arithmetic

The design and implementation of a digital (numerical) optical matrix-vector multiplier are presented. The objective is to demonstrate the operation of an optical processor designed to minimize computation time in performing a practical computing application. This is done by using the large array of processing elements in a Hughes liquid crystal light valve, and relying on the residue arithmetic representation, a holographic optical memory, and position coded optical look-up tables. In the design, all operations are performed in effectively one light valve response time regardless of matrix size. The features of the design allowing fast computation include the residue arithmetic representation, the mapping approach to computation, and the holographic memory. In addition, other features of the work include a practical light valve configuration for efficient polarization control, a model for recording multiple exposures in silver halides with equal reconstruction efficiency, and using light from an optical fiber for a reference beam source in constructing the hologram. The design can be extended to implement larger matrix arrays without increasing computation time.

Habiby, Sarry F.↗

Real-time laser holographic interferometry for aerodynamics

Recent developments in thermoplastic recording holograms and advancements in automated image digitalization and analysis make real-time laser holographic interferometry feasible for two-dimensional flows such as airfoil flows. Typical airfoil measurements would include airfoil pressure distributions, wake and boundary layer profiles, and flow field density contours. This paper addresses some of the problems and requirements of a real-time laser holographic interferometer.

Lee, George↗

Measuring Airflow With Digital Holographic Interferometry

Digital image-processing system assists in analysis of holographic interferometric images of flow about airfoil. Operating semiautomatically, identifies, counts, and labels interference fringes, then processes distances between fringes into distribution of pressure on surface of airfoil. Yields data on pressure faster than manual image-analyses techniques, and data compares favorably with those obtained by manual analysis and by probe measurements of pressure. Uses computer programs evaluating interferograms along straight or curved lines represented by polygon segments. User prompted for such inputs as reference points and fringe number. Digitizes holographic interferograms of flow and processes them into data of pressure or other properties of flow.

Torres, Francisco J.↗

Laser holographic interferometric measurements of the flow in a scramjet inlet at Mach 4

The need for quantitative data is addressed by laser holographic interferometry (LHI) by efficiently recording and reducing high resolution density data. This paper investigates the potential to get quantitative data from an interferogram created from two separate holographic plates. THe LHI measurements were made on a scramjet inlet at Mach 4. LHI successfully generated results for both internal and external flows, and demonstrated its ability to map entire flow fields. Of the three data reduction techniques used, the four-bucket method gave better results than the three-bucket or three-by-three methods. This technique requires high quality holograms as well as a good resolution in the digital images to produce good data.

Mcarthur, J. Craig↗

Holographic matched filter for full-field in-line signal processing of optical-fiber sensor outputs

A holographic matched filter is used to measure the changes in the output of a dual-mode fiber undergoing axial strain. The hologram is formed by interfering collimated light from a single-mode reference fiber and an unstrained dual-mode sensor fiber on a small piece of holographic material. When the hologram is illuminated by the strained sensor fiber, the cross-correlation field comparing the dual-mode output and its previous state, as recorded in the hologram, is collected, focused into a pick-up fiber, and sent to a photodiode. This arrangement allows for a compact, in-line method for full-field processing of the strain-induced changes in phase and amplitude in the sensor fiber. Other uses of such fiber-based correlators are suggested.

Indebetouw, Guy↗

The use of holographic interferometry for measurements of temperature in a rectangular heat pipe

Holographic interferometry is a nonintrusive method and as such possesses considerable advantages such as not disturbing the velocity and temperature field by creating obstacles which would alter the flow field. These optical methods have disadvantages as well. Holography, as one of the interferometry methods, retains the accuracy of older methods, and at the same time eliminates the system error of participating components. The holographic interferometry consists of comparing the objective beam with the reference beam and observing the difference in lengths of optical paths, which can be observed during the propagation of the light through a medium with locally varying refractive index. Thus, change in refractive index can be observed as a family of nonintersecting surfaces in space (wave fronts). The object of the investigation was a rectangular heat pipe. The goal was to measure temperatures in the heat pipe, which yields data for computer code or model assessment. The results were obtained by calculating the temperatures by means of finite fringes.

Marn, Jure↗

Holographic instrumentation for monitoring crystal growth in space

Measurement requirements and candidates for measuring crystal growth in space are described, emphasizing holographic instrumentation. Existing instrumentation planned for the IML-1 Spaceflight is described along with advanced concepts for future application which incorporate diode lasers, fiber optics, and holographic optical elements. Particle image displacement velocimetry in crystal growth chambers is described.

Trolinger, James D.↗

Practical design considerations and performance characteristics of high numerical aperture holographic lenses

The diffraction efficiency of interferometrically formed holographic lenses is influenced by the recording geometry and properties of the recording material. Variations in efficiency increase when attempting to make high numerical aperture elements. The factors which influence the diffraction efficiency of high numerical aperture holographic lenses are examined.

Kostuk, Raymond K.↗

Holographic study of conventional and negative Poisson's ratio metallic foams - Elasticity, yield and micro-deformation

An experimental study by holographic interferometry is reported of the following material properties of conventional and negative Poisson's ratio copper foams: Young's moduli, Poisson's ratios, yield strengths and characteristic lengths associated with inhomogeneous deformation. The Young's modulus and yield strength of the conventional copper foam were comparable to those predicted by microstructural modeling on the basis of cellular rib bending. The reentrant copper foam exhibited a negative Poisson's ratio, as indicated by the elliptical contour fringes on the specimen surface in the bending tests. Inhomogeneous, non-affine deformation was observed holographically in both foam materials.

Chen, C. P.↗

Ruled and holographic experiment (AO 138-5)

The AO 138-5 experiment was designed, via the FRECOPA (FRench COoperative PAyload) experiment with the aim to study the optical behavior of different diffraction gratings submitted to space vacuum long exposure and solar irradiation. Samples were ruled and holographic gratings, masters or replica, and some additional control mirrors with various coatings. The experiment was located on the B3, trailing edge of the LDEF and was protected against Atomic Oxygen flux. The experienced thermal cycling was evaluated from -23 C to 66 C during the flight, 34,000 orbits. The samples (two batches of four pieces) were located on a dedicated plate, by a pair of equivalent gratings or mirrors; optical faces were located on the external side. The plate was inside a canister, which had been opened in space for ten months. When the satellite returned to Kennedy Space Center, the remaining vacuum in the canister was still correct. The analysis focused on the triple point characterization including light efficiency, wavefront flatness quality and stray light level. Tests were conducted on control mirrors and gratings (rules and holographic master or replica) loaded but not exposed to cosmic dust or direct solar irradiations. They did not show any significant variations. Solar exposure had damaged the coating (aluminum and platinum) reflectivity in the Ultra-Violet region; the degradation is higher with the gratings, in terms of efficiency. However, wavefront flatness quality and stray light level tests revealed no additional changes.

Bonnemason, Francis↗

Holographic testing of composite propfans for a cruise missile wind tunnel model

Each of the approximately 90 composite propfan blades constructed for a 55 percent scale cruise missile wind tunnel model were holographically tested to obtain natural frequencies and mode shapes. These data were used not only for quality assurance, but also to select sets of similar blades for each blade row. Presented along with the natural frequency data is a description of a computer-based image processing system developed to supplement the photographic based system for holographic image analysis and storage. The new system is quicker and cheaper, the holograms are indexed better, and several engineers can access the data simultaneously. The only negative effect is a slight reduction in image resolution, which does not influence the end use.

Miller, Christopher J.↗