Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Our present state of ignorance of the outer planets and their satellites.

Although the outer solar system contains the bulk of the angular momentum of the system and a huge fraction of the total planetary mass, very little is actually known about it. Massive Jupiter, with its low mean density and huge red spot (possibly a Taylor column), shows a complex rotational pattern as a result of three rotating systems, each having a different period. Atmospheric scattering of the reflected solar radiation makes spectral interpretation uncertain. Imprecisions in the Bond albedo cause discrepancies between actual and predicted solar energy absorbed. Saturn is similar to Jupiter in massiveness, low density, atmospheric aerosols, and albedo. Its rings are believed to be largely water ice. To date, no evidence of radiation belts, analogous to Jupiter's, exists for Saturn, Uranus, or Neptune. Methane and hydrogen have been detected in the atmospheres of all these planets, but the mole fraction of hydrogen is lower in the atmospheres of Uranus and Neptune. Uranus' 98 degree inclination will provide basis for study of its atmospheric circulation. Our knowledge of Pluto is restricted to the sparsest physical data.

Rea, D. G.↗

Interstellar molecular hydrogen

Recent progress in the detection of H2 in the interstellar medium is reviewed. The hydrogen molecule is discussed in terms of properties, and collisional excitation and dissociation rates. Molecular hydrogen formation and cooling and heating by H2 are also discussed. Ultraviolet studies provided information for the study of the formation-destruction equilibrium of H2, the kinetic temperature of the cloud, the hydrogen particle density, and the ultraviolet radiation field. Infrared observations in Orion and the planetary nebula NGC 7027 reveal two detections of vibrationally excited H2. In addition, thermal and nonthermal excitation mechanisms are discussed. Finally, it is noted that increased ultraviolet sensitivity is necessary for thorough H2 studies.

Shull, J. M.↗

Molecular Hydrogen in the Quiescent Disk of SW UMA

The data have been acquired and re-reduced by Alex Lobel. We do not detect the molecular hydrogen transitions expected from models of a molecular disk illuminated by Ly alpha photons. We are currently working on an interpretation of the O VI emission lines to determine whether they arise in the disk or the boundary layer. The upper limit on continuum flux will provide an important constraint on models of white dwarf heating in cataclysmic variables.

Raymond, John C.↗

IUE observations of PG 1115 + 080 - The He I Gunn-Peterson test and a search for the lensing galaxy

Five observations of PG 1115 + 080 taken with the IUE SWP camera have been combined in order to carry out the He I Gunn-Peterson test and to search for a Lyman limit which could determine the redshift of the lens candidate reported by Christian et al. (1987). No Lyman-limit discontinuities are found, implying that the lensing galaxy does not intercept the line of sight or does not contain enough neutral hydrogen to be detected as a Lyman-limit edge. It is estimated that the lens column density for neutral hydrogen is 3 x 10 to the 16th/sq cm or less if it intercepts the line of sight.

Tripp, Todd M.↗

Molecular hydrogen emission in L1448 associated with a highly collimated molecular outflow

A near-infrared camera was used to search for jets around low-luminosity embedded infrared sources in nearby molecular clouds. The near-infrared offers the advantage that the extinction is very low compared with the optical. A jet is detected in molecular hydrogen at 2.12 microns toward a source in L1448. Given the sample size this indicates a detection rate of no more than a couple percent. The average visual extinction in L1448 is roughly 5 mag. The properties of the molecular hydrogen emission are similar to those measured for known Herbig-Haro objects, suggesting the jet is a buried Herbig-Haro object/jet that would be visible in the optical if the extinction were lower. The L1448 jet coincides with the unusual CO outflow that is highly collimated and contains high-velocity CO 'bullets'. The properties of the L1448 source suggest it defines a transition case between molecular outflows and Herbig-Haro jets, combining the characteristics of both.

Terebey, Susan↗

Molecular hydrogen and the 2 micron spectrum of NGC 7027

The spectrum of the planetary nebula NGC 7027 in the range 1.6-2.5 microns was obtained with a resolution of 1.2 per cm. The presence of molecular hydrogen emission in the v = 1-0 S(1), Q(1), and Q(3) lines is confirmed, and the detection of H2 lines v = 1-0 Q(2), Q(4), S(0), and S(2) is reported. The H2 line strengths, with upper limits for the v = 2-1 band, suggest a model in which the emitting gas is confined to clumps heated by a shock front accompanying an expanding H II region. Emission lines are also detected from atomic hydrogen (Pfund and Brackett series) and from He I and He II.

Smith, H. A.↗

Study to develop improved methods to detect leakage in fluid systems, phase 2

An ultrasonic contact sensor engineering prototype leak detection system was developed and its capabilities under cryogenic operations demonstrated. The results from tests indicate that the transducer performed well on liquid hydrogen plumbing, that flow and valve actuation could be monitored, and that the phase change from gaseous to liquid hydrogen could be detected by the externally mounted transducers. Tests also demonstrate the ability of the system to detect internal leaks past valve seats and to function as a flow meter. Such a system demonstrates that it is not necessary to break into welded systems to locate internal leaks.

Janus, J. C.↗

Active galactic nuclei with ultrasoft X-ray emission

The discovery of a class of AGN with clearly distinguishable soft X-ray components below 0.5 keV is reported. These AGN were detected through equivalent hydrogen column densities that are less than a few times 10 exp 20/sq cm. At least three kinds of AGN comprise this sample: low-redshift quasars and Seyfert galaxies that have only ultrasoft emission (these objects lack detectable hard X-ray emission); AGN that have both ultrasoft as well as hard X-ray components; and high-redshift quasars whose soft emission may originate, as proposed for the lensed quasar 0957 + 561, in an extended source or, alternately, in a source that is luminosity-enhanced due to relativistic beaming.

Cordova, F. A.↗

Fiber-Optic System Would Detect Leaking Liquid H2

Proposed instrument based on optical time-domain reflectometry measures both locations and sizes of leaks in tanks and plumbing storing and transferring liquid hydrogen. Conceived for use in detecting leaks of hydrogen from propulsion system of Space Shuttle, concept applicable to detection of flammable and/or poisonous fumes in chemical-processing plants, fuel-distributing equipment, and other terrestrial applications.

Grove, Charles H.↗

Visualization of hydrogen fires.

Hydrogen fire visualization detection techniques including application of photography, TV and image converter in IR and UV regions

ULTRAVIOLET RADIATION↗

Palladium Implanted Silicon Carbide for Hydrogen Sensing

Silicon carbide is intended for use in fabrication of high-temperature, efficient hydrogen sensors. Traditionally, when a palladium coating is applied on the exposed surface of SiC, the chemical reaction between palladium and hydrogen produces a detectable change in the surface chemical potential. We have produced both a palladium coated SiC as well as a palladium, ion implanted SiC sensor. The palladium implantation was done at 500 C into the Si face of 6H, N-type SiC at various energies, and at various fluences. Then, we measured the hydrogen sensitivity response of each fabricated sensor by exposing them to hydrogen while monitoring the current flow across the p-n junction(s), with respect to time. The sensitivity of each sensor was measured at temperatures between 27 and 300 C. The response of the SiC sensors produced by Pd implantation has revealed a completely different behaviour than the SiC sensors produced by Pd deposition. In the Pd-deposited SiC sensors as well as in the ones reported in the literature, the current rises in the presence of hydrogen at room temperature as well as at elevated temperatures. In the case of Pd-implanted SiC sensors, the current decreases in the presence of hydrogen whenever the temperature is raised above 100 C. We will present the details and conclusions from the results obtained during this meeting.

Muntele, C. I.↗

A Leak Monitor for Industry

GenCorp Aerojet Industrial Products, Lewis Research Center, Marshall Space Flight Center, and Case Western Reserve University developed a gas leak detection system, originally for use with the Space Shuttle propulsion system and reusable launch vehicles. The Model HG200 Automated Gas Leak Detection System has miniaturized sensors that can identify extremely low concentrations of hydrogen without requiring oxygen. A microprocessor-based hardware/software system monitors the sensors and displays the source and magnitude of hydrogen leaks in real time. The system detects trace hydrogen around pipes, connectors, flanges and pressure tanks, and has been used by Ford Motor Company in the production of a natural gas-powered car.

Source record↗

Chemical Gas Sensors for Aeronautic and Space Applications

Aeronautic and space applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. Two areas of particular interest are safety monitoring and emission monitoring. In safety monitoring, detection of low concentrations of hydrogen at potentially low temperatures is important while for emission monitoring the detection of nitrogen oxides, hydrogen, hydrocarbons and oxygen is of interest. This paper discusses the needs of aeronautic and space applications and the point-contact sensor technology being developed to address these needs. The development of these sensors is based on progress in two types of technology: (1) Micromachining and microfabrication technology to fabricate miniaturized sensors. (2) The development of high temperature semiconductors, especially silicon carbide. The detection of each type of gas involves its own challenges in the fields of materials science and fabrication technology. The number of dual-use commercial applications of this microfabricated gas sensor technology make this general area of sensor development a field of significant interest.

Hunter, Gary W.↗

Design and Performance of a Gas Chromatograph for Automatic Monitoring of Pollutants in Ambient Air

In recent years, interest in air pollution constituents has focused on carbon monoxide and hydrocarbons as prime components of polluted air. Instrumental methods have been developed, and commercial instruments for continuous monitoring of these components have been available for a number of years. For the measurement of carbon monoxide, non-dispersive infrared spectroscopy has been the accepted tool, in spite of its marginal sensitivity at low parts-per-million levels. For continuously monitoring total hydrocarbons, the hydrogen flame ionization analyzer has been widely accepted as the preferred method. The inadequacy of this latter method became evident when it was concluded that methane is non-reactive and cannot be considered a contaminant even though present at over 1 ppm in the earth's atmosphere. Hence, the need for measuring methane separately became apparent as a means of measuring the reactive and potentially harmful non-methane hydrocarbons fraction. A gas chromatographic method for the measurement of methane and total hydrocarbons which met these requirements has been developed. In this technique, methane was separated on conventional gas chromatographic columns and detected by a hydrogen flame ionization detector (FID) while the total hydrocarbons were obtained by introducing a second sample directly into the FID without separating the various components. The reactive, or non-methane hydrocarbons, were determined by difference. Carbon monoxide was also measured after converting to methane over a heated catalyst to render it detectable by the FID. The development of this method made it possible to perform these measurements with a sensitivity of as much as 1 ppm full scale and a minimum detectability of 20 ppb. Incorporating this technique, criteria were developed by APCO for a second generation continuous automatic instrument for atmospheric monitoring stations.

Villalobos, R.↗

Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks

In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.

Source record↗

Interstellar molecules

The Princeton equipment on the Copernicus satellite provides the means to study interstellar molecules between the satellite and stars from 20 to 1000 pc distant. The study is limited to stars relatively unobscured by dust which strongly attenuates the ultraviolet continuum flux used as a source to probe the interstellar medium. Of the 14 molecules searched for only three have been detected including molecular hydrogen, molecular HD, and carbon monoxide.

Drake, J. F.↗