Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Study Methods to Standardize Thermography NDE

The purpose of this work is to develop thermographic inspection methods and standards for use in evaluating structural composites and aerospace hardware. Qualification techniques and calibration methods are investigated to standardize the thermographic method for use in the field. Along with the inspections of test standards structural hardware, support hardware is designed and fabricated to aid in the thermographic process. Also, a standard operating procedure is developed for performing inspections with the Bales Thermal Image Processor (TIP). Inspections are performed on a broad range of structural composites. These materials include various graphite/epoxies, graphite/cyanide-ester, graphite/silicon-carbide, graphite phenolic and Keviar/epoxy. Also metal honeycomb (titanium and aluminum faceplates over an aluminum honeycomb core) structures are investigated. Various structural shapes are investigated and the thickness of the structures vary from as few as 3 plies to as many as 80 plies. Special emphasis is placed on characterizing defects in attachment holes and bondlines, in addition to those resulting from impact damage and the inclusion of foreign matter. Image processing through statistical analysis and digital filtering is investigated to enhance the quality and quantify the NDE thermal images when necessary.

Walker, James L.↗

Synchrotron Facilities: Vibration and Stability Challenge

The new generation of synchrotron accelerator facilities are opening exciting new opportunities in imaging, spectroscopy, structural and dynamic studies, and other applications by pushing the envelope of resolution to just a few nanometers and possibly atomic scale (~1 nm). Achieving such a state of resolution in both space and energy is expected to have broad impact on a wide range of disciplines and scientific initiatives in the coming decades, including new studies of small crystals in structural biology, a wide range of nanometer-resolution probes for nanoscience, properties of materials under extreme conditions, etc. Such performance goals place severe requirements on the quality of the electron and photon beams. Within the synchrotron accelerator envelope, and in addition to the need to maintain the electron beam within an extremely stable orbit in order to realize the benefits of the high brightness and small beam sizes, it is essential that the photon beams are also exceedingly stable in both position and angle. Particularly for timing experiments, it is also necessary that the arrival-time jitter of the bunch be small. Transverse beam motions <10% of beam size or angular spread, and longitudinal beam motion of <5% of equilibrium bunch duration, are typically desired. Ideally, the temporal, spatial, and angular stability of the electron beam should be maintained for at least the duration of spectral scans, which typically run from a few milliseconds to a few hours. Achieving such a level of stability that is ever pushing the envelope is an enormous task, and that is where engineering comes into play.

36 MATERIALS SCIENCE↗

X-ray diffraction studies and equation of state of methane at 200 GPa

Solid methane (CH{sub 4}) was compressed up to 202 GPa at 300 K in a diamond-anvil cell. The crystal structure and equation of state over this entire range were determined from angle dispersive X-ray diffraction results. CH{sub 4} undergoes phase transitions from rhombohedral to a simple cubic phase at 19 GPa and from simple cubic to a higher pressure cubic phase at approximately 94 GPa. This higher pressure cubic phase was stable to the maximum pressure investigated. Combined with previous optical measurements, it was found that at room temperature compressed CH{sub 4} remains an insulator with cubic structure to 202 GPa. X-ray images of the solid CH{sub 4} at three pressures, showing the high pressure phase with cubic structure persisting up to 202 GPa. At high pressure the XRD from the sample became increasingly weaker. To improve the quality of XRD pattern, we reduced the X-ray focus spot size and clean-up slits at 171 GPa, and increased the exposure time for each measurement.

03 NATURAL GAS↗

Inorganic Halide Perovskitoid TlPbI 3 for Ionizing Radiation Detection

Room temperature semiconductor detector (RTSD) materials for γ-ray and X-ray radiation are in great demand for the nonproliferation of nuclear materials as well as for biomedical imaging applications. Halide perovskites have attracted great attention as emerging and promising RTSD materials. In this contribution, the material synthesis, purification, crystal growth, crystal structure, photoluminescence properties, ionizing radiation detection performance, and electronic structure of the inorganic halide perovskitoid compound TlPbI 3 are reported on. This compound crystallizes in the ABX 3 non-perovskite crystal structure with a high density of d = 6.488 g·cm –3 , has a wide bandgap of 2.25 eV, and melts congruently at a low temperature of 360 °C without phase transitions, which allows for facile growth of high quality crystals with few thermally-activated defects. High-quality TlPbI 3 single crystals of centimeter-size are grown using the vertical Bridgman method using purified raw materials. A high electrical resistivity of ≈10 12 Ω·cm is readily obtainable, and detectors made of TlPbI 3 single crystals are highly photoresponsive to Ag K α X-rays (22.4 keV), and detects 122 keV γ-rays from 57 Co radiation source. The electron mobility-lifetime product µ e τ e was estimated at 1.8 × 10 –5 cm 2 ·V –1 . A high relative static dielectric constant of 35.0 indicates strong capability in screening carrier scattering and charged defects in TlPbI 3 .

36 MATERIALS SCIENCE↗

Note: Gratings on low absorbing substrates for x-ray phase contrast imaging

Grating based X-ray phase contrast imaging is on the verge of being applied in clinical settings. To achieve this goal, compact setups with high sensitivity and dose efficiency are necessary. Both can be increased by eliminating unwanted absorption in the beam path, which is mainly due to the grating substrates. Fabrication of gratings via deep X-ray lithography can address this issue by replacing the commonly used silicon substrate with materials with lower X-ray absorption that fulfill certain boundary conditions. Gratings were produced on both graphite and polymer substrates without compromising on structure quality. These gratings were tested in a three-grating setup with a source operated at 40 kVp and lead to an increase in the detector photon count rate of almost a factor of 4 compared to a set of gratings on silicon substrates. As the visibility was hardly affected, this corresponds to a significant increase in sensitivity and therefore dose efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The XXL Survey I. Scientific Motivations - Xmm-Newton Observing Plan - Follow-up Observations and Simulation Programme

The quest for the cosmological parameters that describe our universe continues to motivate the scientific community to undertake very large survey initiatives across the electromagnetic spectrum. Over the past two decades, the Chandra and XMM-Newton observatories have supported numerous studies of X-ray-selected clusters of galaxies, active galactic nuclei (AGNs), and the X-ray background. The present paper is the first in a series reporting results of the XXL-XMM survey; it comes at a time when the Planck mission results are being finalized. Aims. We present the XXL Survey, the largest XMM programme totaling some 6.9 Ms to date and involving an international consortium of roughly 100 members. The XXL Survey covers two extragalactic areas of 25 deg2 each at a point-source sensitivity of approx. 5 x 10(exp 15) erg/s/sq cm in the [0.5-2] keV band (completeness limit). The surveys main goals are to provide constraints on the dark energy equation of state from the space-time-distribution of clusters of galaxies and to serve as a pathfinder for future, wide-area X-ray missions. We review science objectives, including cluster studies, AGN evolution, and large-scale structure, that are being conducted with the support of approximately 30 follow-up programs. Methods. We describe the 542 XMM observations along with the associated multi- and numerical simulation programmes. We give a detailed account of the X-ray processing steps and describe innovative tools being developed for the cosmological analysis. Results. The paper provides a thorough evaluation of the X-ray data, including quality controls, photon statistics, exposure and background maps, and sky coverage. Source catalogue construction and multi-associations are briefly described. This material will be the basis for the calculation of the cluster and AGN selection functions, critical elements of the cosmological and science analyses. Conclusions. The XXL multi- data set will have a unique lasting legacy value for cosmological and extragalactic studies and will serve asa calibration resource for future dark energy studies with clusters and other X-ray selected sources. With the present article, we release the XMM XXL photon and smoothed images along with the corresponding exposure maps.

X-rays: general – large-scale structure of Unive↗

Laser Brazing of High Temperature Braze Alloy

The Space Shuttle Main Engine (SSME) consists of 1080 conical tubes, which are furnace brazed themselves, manifolds, and surrounding structural jacket making almost four miles of braze joints. Subsequent furnace braze cycles are performed due to localized braze voids between the coolant tubes. SSME nozzle experiences extremely high heat flux (180 mW/sq m) during hot fire. Braze voids between coolant tubes may result in hot combustion gas escape causing jacket bulges. The nozzle can be disqualified for flight or result in mission failure if the braze voids exceed the limits. Localized braze processes were considered to eliminate braze voids, however, damage to the parent materials often prohibited use of such process. Being the only manned flight reusable rocket engine, it has stringent requirement on the braze process. Poor braze quality or damage to the parent materials limits the nozzle service life. The objective of this study was to develop a laser brazing process to provide quality, localized braze joints without adverse affect on the parent materials. Gold (Au-Cu-Ni-Pd-Mn) based high temperature braze alloys were used in both powder and wire form. Thin section iron base superalloy A286 tube was used as substrate materials. Different Laser Systems including CO2 (10.6 micrometers, 1kW), ND:YAG (1.06 micrometers, 4kW). and direct diode laser (808nm. 150W) were investigated for brazing process. The laser process variables including wavelength. laser power, travel speed and angle of inclination were optimized according to bead geometry and braze alloy wetting at minimum heat input level, The properties of laser brazing were compared to that of furnace brazing. Microhardness profiles were used for braze joint property comparison between laser and furnace brazing. The cooling rate of laser brazing was compared to furnace brazing based on secondary dendritic arm spacing, Both optical and Scanning Electron Microscope (SEM) were used to evaluate the microstructures of the braze materials and tube substrate. Metallography of the laser braze joint was compared to the furnace braze. SEM Energy Disperse X-Ray Spectra (EDX) and back scattered imaging were used to analyze braze alloy segregation. Although all of the laser systems, CO2, ND:YAG, and direct diode laser produced good braze joint, the direct diode laser was selected for its system simplicity, compactness and portability. Excellent laser and braze alloy coupling is observed with powder alloy compared to braze alloy wire. Good wetting is found with different gold based braze alloys. The laser brazing process can be optimized so that the adverse affect on the parent materials can be eliminated. Metallography of the laser braze joint has shown that quality braze joint was produced with laser brazing process. Penetration of the laser braze to the substrate is at neglectable level. Zero penetration is observed. Microstructure examinations shown that no observable changes of the microstructure (grain structure and precipitation) in the HAZ area between laser braze and furnace braze. Wide gaps can be laser brazed with single pass for up to 0.024 inches. Finer dendritic structure is observed in laser brazing compared with equiaxial and coarser grain of the furnace brazing microstructure. Greater segregation is also found in the furnace braze. Higher hardness of the laser braze joint comparing to furnace braze is observed due to the fast cooling rate and Finer microstructure in the laser brazing. Laser braze joint properties meet or exceed the furnace joint properties. Direct diode laser for thin section tube brazing with high temperature braze alloys have been successfully demonstrated. The laser's high energy density and precise control has shown significant advantages in reducing process heat input to the substrates and provide high quality braze joints comparing to other localized braze process such as torch, TIG, and MPTA processes. Significant cost savings can be realized particularly with localized braze comparing to a full furnace braze cycle.

Gao, Y. P.↗

An Anisotropic Scale-Invariant Unstructured Mesh Generator Auitable for Volumetric Imaging Data

Mesh generation algorithms must consider the computational physics schemes to be adopted insomuch as tessellation should attempt to minimize discretization error metrics a priori, while placing elements judiciously yet economically. Basing local element size and shape on local geometric feature size is a promising approach, as the underlying physics may either be scale-invariant or may vary with scale in a predictable way. We present a boundary-fitted scale-invariant unstructured tetrahedral mesh generation algorithm that enables registration of element size to local geometric scale, given a triangulated mesh surface. The resulting tetrahedra are well-shaped and nearly orthogonal to the boundary. Unlike previous feature-based approaches, our algorithm does not require a background mesh, nor does it rely on the medial-axis. In contrast, as a first step, our algorithm produces a gradientlimited feature-size field over the input surface based on efficient ray casting. We illustrate how this field can be used to produce quality grids for computational fluid dynamics based simulations of challenging, topologically complex surfaces derived from magnetic resonance images. The algorithm is implemented in the Pacific Northwest National Laboratory (PNNL) version of the Los Alamos grid toolbox LaGriT[6].

36 MATERIALS SCIENCE↗

Matrix phased arrays for the inspection of CFRP-components

Lightweight components are increasingly used in different industrial sectors such as transportation, energy generation and automotive. This growing field includes different types of CFRP-structures, hybrid materials and glued components showing - compared to their pure metallic counterparts- a significant more complicated structure in terms of internal interfaces and anisotropy of material parameters. In this work we present the use of matrix phased array to increase the amount of obtained information to enhance the inspection quality. We used different types of carbon materials such as 6 mm thick uni- and bidirectional prepreg specimens containing impact damages. The latter were introduced with different energy levels ranging from 1.3 to 7.2 J. By scanning a 2.25 MHz matrix array with 6 × 10 elements above the prepreg surface and using different angels of incidence a complete 3D-image was generated which allows the detection of defects as small as 1mm in a depth of 4 mm. A comparison with conventional approaches show that the signal-to-noise ratio can be highly increased. This enables us to visualize the region of damage within the impact zone, clearly showing the cone-like damage distribution along increasing material depth. The detection quality allows the estimation of the opening angles of the cone shaped damage, which can be used for further evaluation and quantitation of energy dependent impact damages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gaussian process analysis of electron energy loss spectroscopy data: multivariate reconstruction and kernel control

Abstract Advances in hyperspectral imaging including electron energy loss spectroscopy bring forth the challenges of exploratory and physics-based analysis of multidimensional data sets. The multivariate linear unmixing methods generally explore similarities in the energy dimension, but ignore correlations in the spatial domain. At the same time, Gaussian process (GP) explicitly incorporate spatial correlations in the form of kernel functions but is computationally intensive. Here, we implement a GP method operating on the full spatial domain and reduced representations in the energy domain. In this multivariate GP, the information between the components is shared via a common spatial kernel structure, while allowing for variability in the relative noise magnitude or image morphology. We explore the role of kernel constraints on the quality of the reconstruction, and suggest an approach for estimating them from the experimental data. We further show that spatial information contained in higher-order components can be reconstructed and spatially localized.

36 MATERIALS SCIENCE↗

Terahertz Dirac Hyperbolic Metamaterial

Hyperbolic metamaterials (HMMs) are engineered materials with a hyperbolic isofrequency surface, enabling a range of interesting phenomena and applications including negative refraction, enhanced sensing, and subdiffraction imaging, focusing, and waveguiding. Existing HMMs primarily work in the visible and infrared spectral range due to the inherent properties of their constituent materials. Here, we demonstrate a THz-range Dirac HMM using topological insulators as the building blocks. Here, we find that the structure houses up to three high-wavevector volume plasmon polariton (VPP) modes, consistent with transfer matrix modeling and effective medium theory calculations. The VPPs have mode indices greater than 100, significantly larger than observed for VPP modes in HMMs made from metals or doped semiconductors while maintaining comparable quality factors. We attribute these properties to the two-dimensional Dirac nature of the electrons occupying the topological insulator surface states. Because these are van der Waals materials, these structures can be grown at a wafer-scale on a variety of substrates, allowing them to be integrated with existing THz structures and enabling next-generation THz optical devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multienergy CT acquisition and reconstruction with a stepped tube potential scan

Purpose: Based on an energy-dependent property of matter, one may obtain a pseudomonochromatic attenuation map, a material composition image, an electron-density distribution, and an atomic number image using a dual- or multienergy computed tomography (CT) scan. Dual- and multienergy CT scans broaden the potential of x-ray CT imaging. The development of such systems is very useful in both medical and industrial investigations. In this paper, the authors propose a new dual- and multienergy CT system design (segmental multienergy CT, SegMECT) using an innovative scanning scheme that is conveniently implemented on a conventional single-energy CT system. The two-step-energy dual-energy CT can be regarded as a special case of SegMECT. A special reconstruction method is proposed to support SegMECT. Methods: In their SegMECT, a circular trajectory in a CT scan is angularly divided into several arcs. The x-ray source is set to a different tube voltage for each arc of the trajectory. Thus, the authors only need to make a few step changes to the x-ray energy during the scan to complete a multienergy data acquisition. With such a data set, the image reconstruction might suffer from severe limited-angle artifacts if using conventional reconstruction methods. To solve the problem, they present a new prior-image-based reconstruction technique using a total variance norm of a quotient image constraint. On the one hand, the prior extracts structural information from all of the projection data. On the other hand, the effect from a possibly imprecise intensity level of the prior can be mitigated by minimizing the total variance of a quotient image. Results: The authors present a new scheme for a SegMECT configuration and establish a reconstruction method for such a system. Both numerical simulation and a practical phantom experiment are conducted to validate the proposed reconstruction method and the effectiveness of the system design. The results demonstrate that the proposed SegMECT can provide both attenuation images and material decomposition images of reasonable image quality. Compared to existing methods, the new system configuration demonstrates advantages in simplicity of implementation, system cost, and dose control. Conclusions: This proposed SegMECT imaging approach has great potential for practical applications. It can be readily realized on a conventional CT system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth

We present an epi-detected quadruple-modal nonlinear optical microscopic imaging technique (i.e., coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), third-harmonic generation (THG), and two-photon excited fluorescence (TPEF)) based on a picosecond (ps) laser-pumped optical parametric oscillator system for label-free imaging of the tooth. We demonstrate that high contrast ps-CARS images covering both the fingerprint (500–1800 cm{sup −1}) and high-wavenumber (2500–3800 cm{sup −1}) regions can be acquired to uncover the distributions of mineral and organic biomaterials in the tooth, while high quality TPEF, SHG, and THG images of the tooth can also be acquired under ps laser excitation without damaging the samples. The quadruple-modal nonlinear microscopic images (CARS/SHG/THG/TPEF) acquired provide better understanding of morphological structures and biochemical/biomolecular distributions in the dentin, enamel, and the dentin-enamel junction of the tooth without labeling, facilitating optical diagnosis and characterization of the tooth in dentistry.

60 APPLIED LIFE SCIENCES↗

Sputter-Deposited Mo Thin Films: Multimodal Characterization of Structure, Surface Morphology, Density, Residual Stress, Electrical Resistivity, and Mechanical Response

Multimodal datasets of materials are rich sources of information which can be leveraged for expedited discovery of process–structure–property relationships and for designing materials with targeted structures and/or properties. For this data descriptor article, we provide a multimodal dataset of magnetron sputter-deposited molybdenum (Mo) thin films, which are used in a variety of industries including high temperature coatings, photovoltaics, and microelectronics. In this dataset we explored a process space consisting of 27 unique combinations of sputter power and Ar deposition pressure. Here, the phase, structure, surface morphology, and composition of the Mo thin films were characterized by x-ray diffraction, scanning electron microscopy, atomic force microscopy, and Rutherford backscattering spectrometry. Physical properties—namely, thickness, film stress and sheet resistance—were also measured to provide additional film characteristics and behaviors. Additionally, nanoindentation was utilized to obtain mechanical load-displacement data. The entire dataset consists of 2072 measurements including scalar values (e.g., film stress values), 2D linescans (e.g., x-ray diffractograms), and 3D imagery (e.g., atomic force microscopy images). An additional 1889 quantities, including film hardness, modulus, electrical resistivity, density, and surface roughness, were derived from the experimental datasets using traditional methods. Minimal analysis and discussion of the results are provided in this data descriptor article to limit the authors’ preconceived interpretations of the data. Overall, the data modalities are consistent with previous reports of refractory metal thin films, ensuring that a high-quality dataset was generated. The entirety of this data is committed to a public repository in the Materials Data Facility.

36 MATERIALS SCIENCE↗

The Structural Quality of AlxGa1-xN Epitaxial Layers Grown by Digitally-AlloyedModulated Precursor Epitaxy Determined by Transmission Electron Microscopy

Al(x)Ga(1-x)N layers of varying composition (0.5<x(Al)<1.0) grown in the digitally-alloyed modulated precursor epitaxial regime employing AlN and GaN binary sub-layers by metalorganic chemical vapor deposition on AlN templates were characterized by transmission electron microscopy techniques. Fine lamellae were observed in bright field images that indicate a possible variation in composition due to the modulated nature of growth. In higher Ga content samples (x(Al)<0.75), a compositional inhomogeniety associated with thicker island regions was observed, which is determined to be due to large Ga-rich areas formed at the base of the layer. Possible causes for the separation of Ga-rich material are discussed in the context of the growth regime used.

36 MATERIALS SCIENCE↗

In-line three-dimensional holography of nanocrystalline objects at atomic resolution

We report that resolution and sensitivity of the latest generation aberration-corrected transmission electron microscopes allow the vast majority of single atoms to be imaged with sub-Ångstrom resolution and their locations determined in an image plane with a precision that exceeds the 1.9-pm wavelength of 300 kV electrons. Such unprecedented performance allows expansion of electron microscopic investigations with atomic resolution into the third dimension. Here we show a general tomographic method to recover the three-dimensional shape of a crystalline particle from high-resolution images of a single projection without the need for sample rotation. The method is compatible with low dose rate electron microscopy, which improves on signal quality, while minimizing electron beam-induced structure modifications even for small particles or surfaces. Lastly, we apply it to germanium, gold and magnesium oxide particles, and achieve a depth resolution of 1–2 Å, which is smaller than inter-atomic distances.

36 MATERIALS SCIENCE↗

Lithographically defined synthesis of transition metal dichalcogenides

Abstract Transition metal dichalcogenides (TMDs) promise to revolutionize optoelectronic applications. While monolayer exfoliation and vapor phase growth produce extremely high quality 2D materials, direct fabrication at wafer scale remains a significant challenge. Here, we present a method that we call ‘lateral conversion’, which enables the synthesis of patterned TMD structures, with control over the thickness down to a few layers, at lithographically predefined locations. In this method, chemical conversion of a metal-oxide film to TMD layers proceeds by diffusion of precursor propagating laterally between silica layers, resulting in structures where delicate chalcogenide films are protected from contamination or oxidation. Lithographically patterned WS 2 structures were synthesized by lateral conversion and analyzed in detail by hyperspectral Raman imaging, scanning electron microscopy and transmission electron microscopy. The rate of conversion was investigated as a function of time, temperature, and thickness of the converted film. In addition, the process was extended to grow patterned MoS 2 , WSe 2 , MoSe 2 structures, and to demonstrate unique WS 2 /SiO 2 multilayer structures. We believe this method will be applicable to a variety of additional chalcogenide materials, and enable their incorporation into novel architectures and devices.

Kemelbay, Aidar (ORCID:0000000233211483)↗

Modeling the X-Ray Process, and X-Ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Khoshti, Ajay↗