Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An investigation of aqueous ammonium nitrate aerosols with soft X-ray spectroscopy

Aqueous aerosols are important in atmospheric chemistry, drug delivery, and human health. X-ray photoelectron spectroscopy (XPS), a surface-sensitive technique and near-edge X-ray absorption fine structure (NEXAFS) spectroscopy which informs on the bulk, is deployed to study the solvation of ammonium nitrate (NH 4 NO 3 ). Aerosolised solutions of NH 4 NO 3 were introduced into a photoelectron spectrometer via an aerodynamic lens, and interrogated with soft X-ray photons, the resulting electrons were imaged via velocity map imaging. Density functional theory calculations were performed to compare with the measured binding energies of NH 4 + and NO 3 - solvated in water. The results reveal that the nitrate anion has a slight propensity for the surface, while both ammonium and nitrate ions are present in equal measure in the bulk.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Multiplanet System TOI-421: A Warm Neptune and a Super Puffy Mini-Neptune Transiting a G9 V Star in a Visual Binary

We report the discovery of a warm Neptune and a hot sub-Neptune transiting TOI-421 (BD-14 1137, TIC 94986319), a bright (V = 9.9) G9 dwarf star in a visual binary system observed by the Transiting Exoplanet Survey Satellite (TESS) space mission in Sectors 5 and 6. We performed ground-based follow-up observations—comprised of Las Cumbres Observatory Global Telescope transit photometry, NIRC2 adaptive optics imaging, and FIbre-fed Echellé Spectrograph, CORALIE, High Accuracy Radial velocity Planet Searcher, High Resolution Échelle Spectrometer, and Planet Finder Spectrograph high-precision Doppler measurements—and confirmed the planetary nature of the 16 day transiting candidate announced by the TESS team. We discovered an additional radial velocity signal with a period of five days induced by the presence of a second planet in the system, which we also found to transit its host star. We found that the inner mini-Neptune, TOI-421 b, has an orbital period of P{sub b} = 5.19672 ± 0.00049 days, a mass of M{sub b} = 7.17 ± 0.66 M{sub ⊕}, and a radius of R{sub b} = 2.68{sub −0.18}{sup +0.19} R{sub ⊕}, whereas the outer warm Neptune, TOI-421 c, has a period of P{sub c} = 16.06819 ± 0.00035 days, a mass of M{sub c} = 16.42{sub −1.04}{sup +1.06} M{sub ⊕}, a radius of R{sub c} = 5.09{sub −0.15}{sup +0.16} R{sub ⊕}, and a density of ρ{sub c} = 0.685{sub −0.072}{sup +0.080} g cm{sup −3}. With its characteristics, the outer planet (ρ{sub c} = 0.685{sub −0.072}{sup +0.080} g cm{sup −3}) is placed in the intriguing class of the super-puffy mini-Neptunes. TOI-421 b and TOI-421 c are found to be well-suited for atmospheric characterization. Our atmospheric simulations predict significant Lyα transit absorption, due to strong hydrogen escape in both planets, as well as the presence of detectable CH{sub 4} in the atmosphere of TOI-421 c if equilibrium chemistry is assumed.

79 ASTRONOMY AND ASTROPHYSICS↗

Structured ionized winds shooting out from a quasar at relativistic speeds

Evidence indicates that supermassive black holes (SMBHs) exist at the centres of most galaxies. Their mass correlates with the galactic bulge mass, suggesting a coevolution with their host galaxies, most likely through powerful winds. X-ray observations have detected highly ionized winds outflowing at sub-relativistic speeds from the accretion disks around SMBHs. However, the limited spectral resolution of present X-ray instruments has left the physical structure and location of the winds poorly understood, hindering accurate estimates of their kinetic power. Here, in this study, the first X-Ray Imaging and Spectroscopy Mission (XRISM) observation of the luminous quasar PDS 456 is reported. The high-resolution spectrometer Resolve aboard XRISM enabled the discovery of five discrete velocity components outflowing at 20–30% of the speed of light. This demonstrates that the wind structure is highly inhomogeneous, which probably consists of up to a million clumps. The mass outflow rate is estimated to be 60–300 solar masses per year, with the wind kinetic power exceeding the Eddington luminosity limit. Compared with the galaxy-scale outflows, the kinetic power is more than three orders of magnitude larger, whereas the momentum flux is ten times larger. These estimates disfavour both energy-driven and momentum-driven outflow models. This suggests that such wind activity occurs in less than 10% of the quasar phase and/or that its energy/momentum is not efficiently transferred to the galaxy-scale outflows owing to the clumpiness of the wind and the interstellar medium.

Audard, Marc [Univ. of Geneva, Versoix (Switzerlan↗

Depth-resolved sagebrush root metabolomics, rhizosphere microbial communities, and geochemistry at the East River Watershed

This data set consists of results from soil nutrient profile, untargeted metabolomics, mass spec imaging, and amplicon sequencing. Data for soil nutrient profile includes common cations (Ca, Mg, Na, and K etc.) extracted from 3 digesting steps – ammonia acetate (for exchangeable cations), nitric acid (for acid dissolved fraction), and hydrofluoric acid/perchloric acid (HF/HClO4) for whole soil digestion. It also includes concentration of organic carbon, inorganic nitrogen (ammonia and nitrate) and phosphorus (Bray-1 P and nitric acid extract), and total nitrogen and phosphorus. Data for untargeted metabolomics includes metabolomic profile for root exudate/tissues and soil extracts from depths at surface soil to saprolite, that were measured using gas chromatography – mass spectrometry (GC-MS), and liquid chromatography – tandem mass spectrometry (LC-MS/MS). Data for mass spec imaging includes spatial distribution of metabolites that were detected and annotated with Fourier transformation ion cyclotron resonance mass spectrometer (FTICR-MS). Data for amplicon sequencing includes the base paired 16S and ITS ribosomal RNA sequences from Miseq Illumina sequencing. All samples were collected from 2 sampling campaign October 2022 and June 2023. Collectively, these datasets enable a mechanistic evaluation of how nutrient acquisition, especially nitrogen and phosphorus, differs between shallow roots operating in soil and deep roots functioning within the fractured bedrock zone. All files are provided as comma-separated values (CSV) fies (.csv) and (GZIP) file (.gz). The compressed .gz FASTQ files can be read directly in R using the dada2 package as part of the amplicon sequence analysis workflow. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. This research was performed on a project award 60563 (https://dx.doi.org/10.46936/expl.proj.2022.60563/60008727) from the Environmental Molecular Sciences Laboratory, a DOE Office of Science User Facility sponsored by the Biological and Environmental Research program under Contract No. DE-AC05-76RL01830.

EARTH SCIENCE > AGRICULTURE > SOILS > CARBON↗

Multi-delay coherence imaging spectroscopy optimized for ion temperature measurements in the divertor plasma of the Wendelstein 7-X stellarator

A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Looking at the bigger picture: Identifying the photoproducts of pyruvic acid at 193 nm

Here, photodissociation of pyruvic acid (PA) was studied in the gas-phase at 193 nm using two complementary techniques. The time-sliced velocity map imaging arrangement was used to determine kinetic energy release distributions of fragments and estimate dissociation timescales. The multiplexed photoionization mass spectrometer setup was used to identify and quantify photoproducts, including isomers and free radicals, by their mass-to-charge ratios, photoionization spectra, and kinetic time profiles. Using these two techniques, it is possible to observe the major dissociation products of PA photodissociation: CO 2 , CO, H, OH, HCO, CH 2 CO, CH 3 CO, and CH 3 . Acetaldehyde and vinyl alcohol are minor primary photoproducts at 193 nm, but products that are known to arise from their unimolecular dissociation, such as HCO, H 2 CO, and CH 4 , are identified and quantified. A multivariate analysis that takes into account the yields of the observed products and assumes a set of feasible primary dissociation reactions provides a reasonable description of the photoinitiated chemistry of PA despite the necessary simplifications caused by the complexity of the dissociation. These experiments offer the first comprehensive description of the dissociation pathways of PA initiated on the S 3 excited state. Most of the observed products and yields are rationalized on the basis of three reaction mechanisms: (i) decarboxylation terminating in CO 2 + other primary products (~50%); (ii) Norrish type I dissociation typical of carbonyls (~30%); and (iii) O—H and C—H bond fission reactions generating the H atom (~10%). The analysis shows that most of the dissociation reactions create more than two products. This observation is not surprising considering the high excitation energy (~51 800 cm –1 ) and fairly low energy required for dissociation of PA. We find that two-body fragmentation processes yielding CO 2 are minor, and the expected, unstable primary co-fragment, methylhydroxycarbene, is not observed because it probably undergoes fast secondary dissociation and/or isomerization. Norrish type I dissociation pathways generate OH and only small yields of CH 3 CO and HOCO, which have low dissociation energies and further decompose via three-body fragmentation processes. Experiments with d 1 -PA (CH 3 COCOOD) support the interpretations. The dissociation on S 3 is fast, as indicated by the products’ recoil angular anisotropy, but the roles of internal conversion and intersystem crossing to lower states are yet to be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

HAT-P-68b: A Transiting Hot Jupiter around a K5 Dwarf Star

We report the discovery by the ground-based Hungarian-made Automated Telescope Network (HATNet) survey of the transiting exoplanet HAT-P-68b, which has a mass of 0.724 ± 0.043 M {sub J}, and radius of 1.072 ± 0.012 R {sub J}. The planet is in a circular P = 2.2984 day orbit around a moderately bright V = 13.937 ± 0.030 magnitude K-dwarf star of mass 0.673{sub −0.014}{sup +0.020} M {sub ⊙}, and radius 0.6726 ± 0.0069 R {sub ⊙}. The planetary nature of this system is confirmed through follow-up transit photometry obtained with the Fred L. Whipple Observatory (FLWO) 1.2 m telescope, high-precision radial velocities measured using Keck I/High Resolution Echelle Spectrometer (HIRES), FLWO 1.5 m/Tillinghast Reflector Echelle Spectrograph (TRES), and Observatoire de Haute-Provence (OHP) 1.9 m/Sophie, and high-spatial-resolution speckle imaging from WIYN 3.5 m/DSSI. HAT-P-68 is at an ecliptic latitude of +3° and outside the field of view of both the NASA Transiting Exoplanet Survey Satellite primary mission and the K2 mission. The large transit depth of 0.036 mag (r band) makes HAT-P-68b a promising target for atmospheric characterization via transmission spectroscopy.

47 OTHER INSTRUMENTATION↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

A Replacement Cold Neutron Guide System for HFIR (Conceptual Design Report)

The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗