Search NASA⌕ Search

SEARCH · Search NASA

Results for “in situ analytics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Miniature GC-Minicell Ion Mobility Spectrometer (IMS) for In Situ Measurements in Astrobiology Planetary Missions

Astrobiology flight experiments require highly sensitive instrumentation for in situ analysis of volatile chemical species and minerals present in the atmospheres and surfaces of planets, moons, and asteroids. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The use of land rovers and balloon aero-rovers place additional emphasis on miniaturization of the analytical instrumentation. In addition, smaller instruments, using tiny amounts of consumables, allow the use of more instrumentation and/or ionger mission life for stationary landers/laboratories. The miniCometary Ice and Dust Experiment (miniCIDEX), which combined Gas Chromatography (GC) with helium Ion Mobility Spectrometry (IMS), was capable of providing the wide range of analytical information required for Astrobiology missions. The IMS used here was based on the PCP model 111 IMS. A similar system, the Titan Ice and Dust Experiment (TIDE), was proposed as part of the Titan Orbiter Aerorover Mission (TOAM). Newer GC systems employing Micro Electro- Mechanical System (MEMS) based technology have greatly reduced both the size and resource requirements for space GCs. These smaller GCs, as well as the continuing miniaturization of Astrobiology analytical instruments in general, has highlighted the need for smaller, dry helium IMS systems. We describe here the development of a miniature, MEMS GC-IMS system (MEMS GC developed by Thorleaf Research Inc.), employing the MiniCell Ion Mobility Spectrometer (IMS), from Ion Applications Inc., developed through NASA's Astrobiology Science and Technology Instrument Development (ASTID) Program and NASA s Small Business Innovative Research (SBIR) Program.

Kojiro, Daniel R.↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

The Effects of Uncertainty in Initial CME Input Parameters on Deflection, Rotation, Bz, and Arrival Time Predictions

Understanding the effects of coronal mass ejections (CMEs) requires knowing if and when they will impact and their properties upon impact. Of particular importance is the strength of a CME's southward magnetic field component (Bz ). Kay et al. (2013, https://doi:10.1088/0004-637X/775/1/5, 2015, https://doi:10.1088/948 0004-637X/805/2/168) have shown that the simplified analytic model Forecasting a CME's Altered Trajectory (ForeCAT) can reproduce the deflection and rotation of CMEs. Kay, Gopalswamy, Reinard, and Opher (2017, https://doi.org/10.3847/1538-4357/835/2/117) introduced ForeCAT In situ Data Observer, which uses ForeCAT results to simulate magnetic field profiles. ForeCAT In situ Data Observer reproduces the in situ observations on roughly hourly time scales, suggesting that these models could be extremely useful for predictions of Bz . However, as with all models, both models are sensitive to their input parameters, which may not be precisely known for predictions. We explore this sensitivity using ensembles having small changes in the initial latitude, longitude, and orientation of the erupting CME. We explore the effects of different background magnetic field models and find that the changes in deflection and rotation resulting from the uncertainty in the initial parameters tend to exceed the changes from dierent magnetic backgrounds. The range in the in situ proles tends to scale with the range in the deflection and rotation. We also consider a simple arrival time model using ForeCAT results and nd an average absolute error of only 3 hr. We show that an uncertainty in the CME position of 8.1 ± 6.9 leads to variations of 6 hr in the arrival time. This measure depends strongly on the location of impact within the CME with the arrival time changing less for impacts near the nose.

Kay, Christina D.↗

Data use investigations for applications Explorer Mission A (Heat Capacity Mapping Mission): HCMM's role in studies of the urban heat island, Great Lakes thermal phenomena and radiometric calibration of satellite data

The utility of data from NASA'a heat capacity mapping mission satellite for studies of the urban heat island, thermal phenomena in large lakes and radiometric calibration of satellite sensors was assessed. The data were found to be of significant value in all cases. Using HCMM data, the existence and microstructure of the heat island can be observed and associated with land cover within the urban complex. The formation and development of the thermal bar in the Great Lakes can be observed and quantitatively mapped using HCMM data. In addition, the thermal patterns observed can be associated with water quality variations observed both from other remote sensing platforms and in situ. The imaging radiometer on-board the HCMM satellite is shown to be calibratible to within about 1.1 C of actual surface temperatures. These findings, as well as the analytical procedures used in studying the HCMM data, are included.

Schott, J. R.↗

Employing ISRU Models to Improve Hardware Design

An analytical model for hydrogen reduction of regolith was used to investigate the effects of several key variables on the energy and mass performance of reactors for a lunar in-situ resource utilization oxygen production plant. Reactor geometry, reaction time, number of reactors, heat recuperation, heat loss, and operating pressure were all studied to guide hardware designers who are developing future prototype reactors. The effects of heat recuperation where the incoming regolith is pre-heated by the hot spent regolith before transfer was also investigated for the first time. In general, longer reaction times per batch provide a lower overall energy, but also result in larger and heavier reactors. Three reactors with long heat-up times results in similar energy requirements as a two-reactor system with all other parameters the same. Three reactors with heat recuperation results in energy reductions of 20 to 40 percent compared to a three-reactor system with no heat recuperation. Increasing operating pressure can provide similar energy reductions as heat recuperation for the same reaction times.

Linne, Diane L.↗

Pre-Mission Input Requirements to Enable Successful Sample Collection by A Remote Field/EVA Team

The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team, part of the Solar System Exploration Virtual Institute (SSERVI), is a field-based research program aimed at generating strategic knowledge in preparation for human and robotic exploration of the Moon, near-Earth asteroids, Phobos and Deimos, and beyond. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused and, moreover, is sampling-focused with the explicit intent to return the best samples for geochronology studies in the laboratory. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. We examined the in situ sample characterization and real-time decision-making process of the astronauts, with a guiding hypothesis that pre-mission training that included detailed background information on the analytical fate of a sample would better enable future astronauts to select samples that would best meet science requirements. We conducted three tests of this hypothesis over several days in the field. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This was not meant to be a blind, controlled test of crew efficacy, but rather an effort to explicitly recognize the relevant variables that enter into sampling protocol and to be able to develop recommendations for crew and backroom training in future endeavors.

FINESSE↗

In-situ x-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ x ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (0)1, (0)3, (0)5, and (0)8 composite specimens, showed that x ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

Baaklini, George Y.↗

In situ X-ray monitoring of damage accumulation in SiC/RBSN tensile specimens

The room-temperature tensile testing of silicon carbide fiber reinforced reaction-bonded silicon nitride (SiC/RBSN) composite specimens was monitored by using in-situ X-ray film radiography. Radiographic evaluation before, during, and after loading provided data on the effect of preexisting volume flaws (high density impurities, and local density variations) on the fracture behavior of composites. Results from (O)1, (O)3, (O)5, and (O)8 composite specimens showed that X-ray film radiography can monitor damage accumulations during tensile loading. Matrix cracking, fiber-matrix debonding, and fiber pullout were imaged throughout the tensile loading history of the specimens. Further, in-situ film radiography was found to be a helpful and practical technique for estimating interfacial shear strength between the SiC fiber and the RBSN matrix by the matrix crack spacing method. It is concluded that pretest, in-situ, and post-test radiography can provide for a greater understanding of ceramic matrix composite mechanical behavior, a verification of related experimental procedures, and a validation and development of related analytical models.

Baaklini, George Y.↗

Chemical Detection and Identification Techniques for Exobiology Flight Experiments

Exobiology flight experiments require highly sensitive instrumentation for in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical Instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. Advances in technology may be achieved by increasing the amount of information acquired by a given technique with greater analytical capabilities and miniaturization of proven terrestrial technology. We describe here methods to develop analytical instruments for the detection and identification of a wide range of chemical species using Gas Chromatography. These efforts to expand the analytical capabilities of GC technology are focused on the development of detectors for the GC which provide sample identification independent of the GC retention time data. A novel new approach employs Penning Ionization Electron Spectroscopy (PIES).

Kojiro, Daniel R.↗

Analytical/Operational Requirements for the In Situ Chemical Analysis of Cometary and Planetary Environments Using GC-IMS

Exobiology flight experiments require highly sensitive instrumentation for the in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. The miniCIDEX instrument was developed for the chemical analysis of a cemetery environment. It combined a Gas Chromatograph (GC) with a helium based Ion Mobility Spectrometer (IMS) to fulfill the analytical requirements of a cemetery exobiology mission: universal response; ppb sensitivity; low mass, volume and consumable MiniCIDEX is now a candidate for the chemical analysis instrument of a Titan Aero-rover Mission. The complexity of the analyses will be similar to the comet application with a heavier emphasis on organic molecules. Because the Titan Aero-Rover will be a balloon powered rover, much more attention is placed on the total mass of the instrument package. The GC will likely be a Micro-Electro-Mechanical-System (MEMS) design, smaller than the initial miniCIDEX GC by a factor of ten (with a similar reduction in consumable use). Similar miniaturization of the helium-based IMS will be necessary while maintaining the analytical capabilities. The two mission applications, the analytical requirements, and the evolution of the IMS design to accommodate these requirements will be presented.

Kojiro, Daniel R.↗

First in-situ Nitrogen Isotope Measurements in Martian Meteorites

The origin and timing of the accretion of volatile elements on the terrestrial planets remains a subject of controversy. Nitrogen and hydrogen isotopes are powerful tools to constrain the source(s) of primordial volatiles accreted by planetary bodies because their isotope ratios (15N/14N; D/H) differ significantly between different solar system reservoirs (e.g., solar, chondritic, cometary). Hf-W data of martian samples indicate that Mars accreted very rapidly in the inner solar system and reached half ofits size in 1.8 Myr [1]. Therefore, martian samples are key to understand the distribution of volatile elements in the inner solar system during the early stages of planetary formation. Since no space missions have yet returned samples from Mars, martian meteorites (Shergottites, Nakhlites, Chassignites) are unique samples to constrain the source(s) of volatiles present in the martian mantle. The goal of this study was to target pristine phases(e.g., melt inclusions, mesostasis) for in-situ measurements of their nitrogen content and isotopic ratios to access the most primitive melt of the Chassignites and Nakhlites reservoirs. Five different Nakhlites (Nakhla, NWA 998, MIL 03346, Y 000593,NWA 6148) and Chassigny were analysed [2] using a recent high-resolution analytical technique that allows constraining the nitrogen composition of both carbon-bearing and carbon-free phases in natural and synthetic samples. Nitrogen was measured in the form of 14N16O- and 15N16O- with the CAMECA 1280-HR2 at the CRPG [3]. A significant amount of nitrogen was detected in melt inclusions in Chassigny and in the mesostasis of Nakhla, Y000593, MIL 03346, and NWA 6148. Nitrogen isotope signatures of Chassigny and Nakhlites exhibit a heavy isotope enrichment compared to Earth's mantle, and are consistent with a carbonaceous chondrite-like source [4]. This suggests that Earth and Mars accreted nitrogen from different chondritic sources. Overall, our in-situ technique is a unique and powerful tool to characterize the nitrogen abundance and isotopic composition of natural samples.

C Deligny↗

Temporal and spatial variations observed in the ionospheric composition of Venus - Implication for empirical modelling

The distributions of several ion species in a data base obtained by in situ measurements of the thermal ion composition of the ionosphere of Venus by the Pioneer Venus Orbiter have been sorted to identify temporal and spatial variations and determine the feasibility of an analytical representation of the experimental results. The first results from the sorting of several prominent ions including O(+), O2(+), and H(+) and several minor ions including CO2(+), C(+), and H2(+) reveal significant diurnal variations which consist of strong day to night contrast in the ion concentrations, with differences of one to two orders of magnitude, depending upon ion mass and altitude. It is suggested that repeatable day to night gradients in the ion distribution are adaptable to parametric modeling.

Taylor, H. A., Jr.↗

Rationale for Mars Rover/Sampler Return mission

A Mars Rover/Sample Return (MRSR) mission is currently being studied for the late 1990's. The objectives of the mission are to better understand the origin and evolution of Mars, to search for evidence of former life, and to improve the knowledge of the Martian environment in preparation for subsequent human exploration. Having formed in a different part of the Solar System from Earth, Mars will provide clues that will better enable the discrimination between conflicting theories of Solar System formations. Mars is also a natural laboratory on which a wide range of geologic and meteorological processes have operated under conditions very different from those on Earth. Samples are needed so that the full range of analytical techniques available here on Earth can be applied to the study of these issues. The rover provides the mobility needed to access different materials, and can be equipped with an analytical capability so that the planet can be sampled intelligently. The rover will also provide the means of exploring the planet on a human scale and performing a wide range of in situ measurements at different locations. Different mission scenarios are currently being studied with the goal of achieveing sample return before the end of the century.

Carr, Michael H.↗

Space R/T base: Propulsion (high thrust chemical)

The topics presented are covered in viewgraph form. The programmatic objective is to provide a technology base and maintain an institutional capability for continued advances in the development of advanced space propulsion systems to support launch, upper stage, orbit transfer and ascent/descent engines. The technical objectives are to study: (1) validated design and analytical codes for cryogenic turbopump bearings and seals; (2) design methodologies and diagnostic capabilities for combustion stability; and (3) reduced operations cost, increase life, safety, higher energy density propellants, and in-situ engine concepts.

Gorland, S.↗

Gas Chromatographic Detectors for Exobiology Flight Experiments

Exobiology flight experiments require highly sensitive instrumentation for in situ chemical analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. Future missions to Mars', comets, or planetary moons such as Europa, will perform experiments with complex analyses. In addition, instrumentation for such missions must perform under severely restricted conditions with limited resources. To meet these analytical requirements, improved methods and highly sensitive yet smaller instruments must continually be developed with increasingly greater capabilities. We describe here efforts to achieve this objective, for past and future missions, through the development of new or the improvement of existing sensitive, miniaturized gas chromatographic detectors.

Kojiro, Daniel R.↗

Analysis and simulation of the Ultrasonic/Sonic Driller/Corer (USDC)

The USDC was developed to address the challenges to the NASA objective of planetary in-situ rock sampling analysis. A computer program was developed to simulate the operation of the USDC and successfully predicted the characteristic behavior of the new device. This paper covers the theory, the analytical models and the algorithms that were developed and predicted the results.

piezoelectric↗

Development of a Low Power Gas Chromatograph-Mass Spectrometer for In-Situ Detection of Organics in Martian Soil

The Mars Organic Molecule Analyzer (MOMA) is a joint venture by NASA and the European Space Agency (ESA) to develop a sensitive, light-weight, low-power mass spectrometer for chemical analysis on Mars. MOMA is a key analytical instrument aboard the 2018 ExoMars rover mission seeking signs of past or present life. The current prototype was built to demonstrate operation of gas chromatography (OC) and laser desorption (LD) mass spectrometry under martian ambient conditions (5-7 Torr of CO2-rich atmosphere). Recent reports have discussed the MO MA concept, design and performance. Here, we update the current prototype performance, focusing specifically on the GCMS mode.

Pinnick, Veronica↗