Search NASASearch

SEARCH · Search NASA

Results for “industrial process heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,093 records · Page 9

Bypass heat exchanger configuration to reroute core flow

A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.

Terwilliger, Neil

Fuel Heating System Design and Thermal Modeling for Aviation Combustion Research

Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.

Jet fuel heating system

Analytical Model for Steady Flow through a Finite Channel with One Porous Wall with Arbitrary Variable Suction or Injection

This paper presents an exact solution of two-dimensional laminar flow through a finite length channel with one porous wall. It improves upon previous solutions by (1) satisfying the no-slip boundary condition at the channel dead end, (2) adding a turbulent term to the porous wall boundary condition, (3) allowing for arbitrary variable suction or injection across the porous wall, and (4) model validation against new cryogenic liquid hydrogen and oxygen experimental data. Of particular interest in the current work is the modeling of cryogenic propellant flow through a porous liquid acquisition device (LAD) screen and channel inside a propellant tank. First, a detailed review of the literature is presented for previously attempted solutions to channel flow with one porous wall. Next, the governing equations, boundary conditions, and model assumptions are used to derive the analytical flow solution and present general model results for pressure and velocity fields within the channel. Then, the model solution is compared with horizontal LAD channel flow data in liquid oxygen as well as vertical LAD channel flow data in an inverted outflow configuration in liquid hydrogen. Model results are used to update the static cryogenic bubble point pressure model with a dynamic bubble point term which factors in enhanced convection and cooling at the screen during propellant outflow. Convective heat transfer at the LAD screen during outflow is also quantified by comparing model and data. The new analytical flow solution with the dynamic bubble point model is shown to compare well with available cryogenic experimental data

Navier Stokes Equations

Minimum Heating Re-Entry Trajectories for Advanced Hypersonic Launch Vehicles

Optimal re-entry trajectories are generated for reusable launch vehicles which minimize: (1) the heat absorbed at the vehicle surface, (2) the lower surface temperature, and (3) the heat absorbed by the internal structure. The approach uses the energy state approximation technique and a finite control volume heat transfer code coupled to a flight path integration code. These trajectories are compared to the optimal re-entry trajectory minimizing the integrated convective heat rate to determine which trajectory produces the minimum internal structural temperatures for a given thermal protection system. Three different thermal protection systems are considered: tile, blanket, and metallic.

Robert Windhorst

Salt to Metal to Salt Heat Transfer in Narrow Fuel Pins (Final CRADA Report)

This work focused on improving the understanding and modeling of conjugate heat transfer in the Stable Salt Reactor (SSR), particularly the transfer of heat from molten fuel salt inside narrow fuel pins, through the metal cladding and into the surrounding coolant salt.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Multilevel Conditional Disturbance Rejection Control for Satellite Attitude Tracking

Recently, the conditional disturbance rejection controller (CDRC) was proposed to improve control performance by leveraging disturbances that have beneficial effects on the system. However, it only considers disturbances acting on the state variable directly influenced by them. Although fast convergence of this state can be achieved with the CDRC, it may unintentionally affect the convergence of the output (i.e., the primary state). Here, in this article, a multilevel CDRC is proposed to enhance satellite attitude control performance by accounting for the effect of disturbances on both attitude (output) and angular velocity. The extended state observer is employed to estimate the lumped disturbance, including the modeling errors and external disturbances. Then, a backstepping-based controller with the multilevel disturbance rejection law (ML-DRL) is designed for attitude tracking. The ML-DRL is developed to improve the control performance by using a disturbance with a damping effect on both attitude and velocity. Faster convergence of attitude and velocity can be achieved by conditionally compensating for the disturbance. The stability of the proposed control method is analyzed by demonstrating that the errors are bounded as time tends to infinity. The attitude control performance of the proposed method is evaluated through numerical examples conducted using the MATLAB/Simulink Multibody tool.

Active disturbance rejection control (ADRC)

Thermal Protection Facility: Taking the Heat

Video highlighting the products and manufacturing capabilities of the Thermal Protection Facility at Kennedy Space Center which is part of the JSC EA/ES division. This record includes an mp4 video with a run time of 9 min. 13 sec.; in color; with sound.

TPSF

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Reduction of baseplate distortion during directed energy deposition using compliant features

Distortion in additive manufacturing (AM) remains a barrier to its adoption in precision industries. Baseplate warpage is one such issue which compromises the feasibility of post-process precision machining. The restriction to thermal contraction of the deposited part, imposed by the baseplate, generates bending moments, that in turn causes warpage. A novel distortion mitigation strategy using baseplates with integrated compliant features, which enables thermal contraction of the build is presented. Six unique design concepts are evaluated, including a solid reference, using two deposition geometries. A laser, hot-wire, directed energy deposition (DED) process is used to deposit a symmetric cylindrical part (C-part) and a T-shaped asymmetric part (T-part). Flatness deviation of baseplates is measured using structured light 3D scanning. Measurements reveal a reduction in net flatness deviation of 58.8% for the C-part and 40.9% for the T-part, compared to the solid reference. While most designs yielded reductions exceeding 30% and 20% for the C- and T-parts, respectively, one configuration resulted in increased deviation. Finite element (FE) simulations are performed to elucidate the underlying mechanisms affecting distortion of compliant baseplates during DED. Despite variations between predictions and measurements, agreement in the general trend is observed. It also revealed that initial flatness errors in baseplates significantly affect its deviation during deposition. Predictions indicate that compliant features significantly affect the thermal distribution as well as the evolution of flatness deviation in the baseplate during deposition. Notably, one design exhibited a reduction in distortion during cooling, following its initial increase during deposition. FE predictions show a maximum reduction of 60.9% and 38.8% in net flatness deviation for the C- and T-parts, respectively. The performance of compliant baseplates is found to be governed by both its the thermal and mechanical characteristics, which are crucial factors to be considered during design.

Mathews, Ritin [ORNL] (ORCID:0000000301440828)

Generalizable Web User Interface for Scalable and Streamlined Deployment of Building Energy Management Systems in Small and Medium-Sized Commercial Buildings

Small and medium-sized commercial buildings (SMCBs) comprise 94% of US commercial buildings yet face significant barriers to implementing building energy management systems despite advances in smart device technology. Existing solutions present critical limitations: cloud-based API solutions simplify deployment but create vendor lock-in constraints; commercial integrated software solutions ensure compatibility via standardized protocols but require substantial cost and technical expertise; open-source IoT platforms offer cost-effective vendor independence but provide insufficient standardized protocol support for commercial building automation. This research presents a generalizable web user interface framework that bridges the gap between evolving smart device capabilities and lagging software infrastructure for SMCBs. The proposed system integrates VOLTTRON open-source middleware with an automated configuration converter that transforms unified specifications written in YAML, a human-readable data-serialization format, into system-specific files, streamlining manual setup processes. The vendor-agnostic architecture supports industry-standard protocols (BACnet and Modbus) and semantic building models while providing adaptive web interfaces that dynamically adjust to various building configurations. Demonstrations through simulation-based testing and a field deployment show automatic interface adaptation across heterogeneous HVAC systems and multizone monitoring. The automated configuration converter also substantially reduces labor-intensive setup.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean