Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared thermography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Heat Transfer Measurements on the Endwall of a Variable Speed Power Turbine Blade Cascade

Heat transfer measurements were obtained on the endwall of a 2-D section of a variable speed power turbine (VSPT) rotor blade linear cascade. Infrared thermography was used to help determine the transition of flow from laminar to turbulent as well as determine regions of flow separation. Steady state data was obtained for six incidence angles ranging from +15.8 deg to -51 deg, and at five flow conditions for each angle. Nusselt number was used as a method to visualize flow transition and separation on the endwall surface and showed the effects of secondary flows on the surface. Nusselt correlation with Reynolds number from multiple flow conditions was used to plot local values of the correlation exponent and indicated the state of the local boundary layer as the flow transitioned from laminar to turbulent as well as secondary flow features.

variable speed power turbine↗

Temperature Mapping Above and Below Air Film-Cooled Thermal Barrier Coatings Using Phosphor Thermometry

Thermal barrier coatings (TBCs) are typically used in conjunction with air film cooling to maximize overall cooling effectiveness and reliability while minimizing sacrifices in engine performance. The effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness have usually been studied separately; however, their contributions to combined cooling effectiveness are interdependent and are not simply additive. The combined cooling effectiveness is always less than the sum of the cooling effectiveness of stand-alone TBC protection and stand-alone air film cooling. These diminishing returns arise because adding the thermally insulating TBC between the cooling air and the surface to be cooled reduces the air film cooling effectiveness and because the air film cooling reduces the heat flux through the TBC and therefore reduces the temperature difference sustained across the TBC thickness. Due to these considerations, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. In this investigation, temperature mapping above and below air film-cooled TBCs was performed using luminescence lifetime imaging-based phosphor thermometry. Measurements were performed in the NASA GRC Mach 0.3 burner rig on a TBC-coated plate using a scaled-up cooling hole geometry where both the hot mainstream gas temperature and the blowing ratio were varied. Surface temperature maps were obtained from a Cr-doped GdAlO3 thermographic phosphor deposited on the surface of the electron-beam vapor-deposited yttria-stabilized zirconia (YSZ) TBC. From separate plates, temperature maps from the bottom of the TBC were obtained from a thin Er-doped YSZ layer integrated into the TBC below the overlying undoped YSZ. Procedures for temperature and cooling effectiveness mapping above and below the air film-cooled TBC surface are described. Most importantly, these measurements enable mapping the combined cooling effectiveness below the TBC, which is more important than surface cooling effectiveness when there is a barrier coating between the hot mainstream gas and the surface that needs thermal protection. Advantages of the luminescence lifetime imaging method over infrared thermography, as well as its limitations to steady-state conditions are discussed.

cooling effectiveness.↗

Heat Transfer Measurements on the Endwall of a Variable Speed Power Turbine Blade Cascade

Heat transfer measurements were obtained on the endwall and a 2-D section of a variable speed power turbine (VSPT) rotor blade. Infrared thermography was used to help determine the transition of flow from laminar to turbulent as well asdetermine regions of flow separation. Steady state data was obtained for six incidence angles ranging from +50 degree to-17 degree, and at five flow conditions for each angle.

Variable Speed Power Turbine↗

Temperature Mapping at the Thermal Barrier Coating/Bond Coat Interface by Luminescence Lifetime Imaging Using Integrated Erbium-Doped Sublayers

Full-field temperature mapping of thermal barrier coated components by either infrared thermography or phosphor thermometry has been limited to surface temperature mapping even though temperature mapping at the thermal barrier coating (TBC)/bond coat interface is more relevant for evaluating the TBC thermal protection performance. For the first time, 2D temperature mapping at the TBC/bond coat interface has now been achieved by full-field luminescence lifetime imaging measurements of emission from a thin erbium-doped yttria-stabilized zirconia (YSZ) sensing layer integrated into the TBC below the overlying undoped YSZ. This new capability was applied to map temperatures at the TBC/bond coat interface for TBC-coated specimens subjected to a heat flux produced by the NASA Glenn high heat flux laser facility. In particular, thermal gradients at the TBC/bond coat interface were mapped in regions where the TBC was subjected to erosion or to mechanically induced delamination crack propagation. Finally, temperature mapping of the TBC/bond coat interface was used to evaluate the effectiveness of surface air film cooling at the TBC/bond coat interface.

Eldridge, Jeffrey I.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

IR camera Measurments↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part 1

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

Raman Scattering↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data was obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (on the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report. The rest of the data will be published in a future report, Part II, along with planned CFD predictions of the complex cooling film flow. The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Nozzle↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hotor combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR =2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (along the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part 1 report. The rest of the data will be published in a future report, Part 2, along with planned CFD predictions of the complex cooling film flow.The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Mark P Wernet↗

Shockwave/Boundary-Layer Interaction Studies Performed in the NASA Langley 20-Inch Mach 6 Air Tunnel

This paper highlights results from a collaborative study performed by The University of Tennessee Space Institute (UTSI) and NASA Langley Research Center on the Shockwave/Boundary-Layer Interaction (SWBLI) generated by a cylindrical protuberance on a flat plate in a Mach 6 flow. The study was performed in the 20-Inch Mach 6 Air Tunnel at NASA Langley Research Center and consisted of two separate entries. In the first entry, simultaneous high-speed schlieren and high-speed pressure-sensitive paint (PSP) imaging – which was performed for the first time in the 20-Inch Mach 6 facility at NASA Langley – were performed as well as simultaneous high-speed schlieren and oil-flow imaging. In the second entry, the model configuration was modified to increase the size of the interaction region. High-speed schlieren and infrared thermography (IR) surface imaging were performed in this second entry. The goal of these tests was to characterize the SBLI in the presence of a laminar, transitional, and turbulent boundary layer using high-speed optical imaging techniques. AoA = sting angle-of-attack (°) dcylinder = cylinder diameter (mm) dtrip = cylindrical tripping element diameter (mm) Δshock = shock stand-off distance (mm) hcylinder = cylinder height (mm) htrip = cylindrical tripping element height (mm) HSS = high-speed schlieren M∞ = freestream Mach number PSP = pressure-sensitive paint Re∞ = freestream unit Reynolds number (m-1) SWBLI = shockwave/boundary-layer interaction θplate = model plate angle (°) Introduction his paper highlights two experimental entries performed in the 20-Inch Mach 6 Air Blowdown Tunnel at NASA Langley Research Center in collaboration with The University of Tennessee Space Institute (UTSI). The purpose of these entries was to characterize the dynamic shockwave/boundary-layer interaction (SWBLI) between a vertical cylinder on a flat plate and laminar, transitional (XSWBLI), and turbulent (SWTBLI) boundary layers with a freestream Mach number of 6 using non-intrusive optical diagnostics. Experiments performed by Murphree et al.1,2 were among the first to specifically characterize XSWBLI induced by a vertical cylinder on a flat plate geometry using several optical measurement techniques. Recent optical studies of XSWBLI phenomenon have been performed by UTSI at Mach 2 in their low-enthalpy blow wind tunnel3-8 and by Texas A&M University and UTSI at Mach numbers of 6 and 7 in their Adjustable Contour Expansion wind tunnel.9 The experiments described in this paper were intended to complement previous studies by expanding the freestream unit Reynolds number range, Re∞, over which the XSWBLI phenomena has been observed. Additionally these experiments, made possible under NASA’s new facility funding model under the Aeronautics Evaluation and Test Capabilities (AETC) project, promoted collaboration between university and NASA researchers. The initial entry in the 20-Inch Mach 6 Air Tunnel at NASA Langley occurred in December of 2016. Originally, testing was to occur in November of 2016 in the 31-Inch Mach 10 Air Tunnel at NASA Langley. This facility was chosen so that the XSWBLI phenomenon could be observed at much higher Mach numbers than had previously been attempted in ground test experiments. The model selected for this experiment, a 10° half-angle wedge with a sharp leading edge (described in detail in section II.B), had previously been used by Danehy et al. [10] for boundary layer transition studies using the nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization technique. In that work, it was determined that transition could be induced downstream of a single htrip = 1-mm tall, dtrip = 4-mm diameter cylindrical tripping element and that the streamwise location of the transition could be changed for a single Re∞ by changing the model angle-of-attack (AoA) (see Fig. A3 in Ref. [10] for more details). Based on the findings of that work, a decision was made to use the wedge model with the cylindrical tripping element to trip the boundary layer flow ahead of a cylindrical protuberance in order to achieve a XSWBLI. Unfortunately, the 31-Inch Mach 10 facility had been taken offline for repairs in October of 2016 and a decision was made to move the test to the 20-Inch Mach 6 facility. Since the behavior of the boundary layer with the chosen model configuration had not been studied before in that facility and the available test time was limited, the entry was considered to be exploratory and was used to collect spatially-resolved and time-resolved flow and surface visualization data that would be used to inform a second entry. Test techniques included simultaneous high-speed schlieren (HSS) captured at 160 kHz and high-speed pressure sensitive paint captured at 10 kHz as well as oil flow visualization, captured at 750 Hz. The second entry in the 20-Inch Mach 6 facility occurred in June and July of 2017. In this follow-on test, modifications to the wind tunnel model were made based on observations made during the first entry and included removing the cylindrical tripping element, increasing the size of the cylinder used to induce the SWBLI to increase the size of the interaction while simultaneously improving spatial resolution, and using a swept ramp array, similar to that described in Ref. [11], to trip the flow to turbulence. Simultaneous HSS (captured at 140 kHz, 100 kHz, and 40 kHz) and conventional IR thermography (captured at 30 Hz) imaging were performed simultaneously in this follow-on entry. This paper is intended to serve as a summary of the work performed during these two entries, to detail lessons learned from each entry, and to highlight some of the datasets acquired. Details on the experimental setup, model configuration, and techniques used are provided. Papers providing a more rigorous analysis of data acquired during the second entry, including statistical, spectral, and modal decomposition methods, can be found in Refs. [12,13]. An entry examining XSWBLI in the 31-Inch Mach 10 Blowdown Wind Tunnel facility is currently planned for mid-to-late calendar year 2019, pending the success of facility repairs. The work performed and described in this paper and the upcoming entry in the 31-Inch Mach 10 facility at NASA Langley have been made possible by NASA’s new facility funding model under the Aeronautics Evaluation and Test Capabilities (AETC) project. Wind Tunnel Facility All experiments discussed in this paper were performed in the 20-Inch Mach 6 Air Tunnel at NASA Langley Research Center. Specific details pertaining to this facility can be found in Refs. [14,15], with only a brief description of the facility provided here. For both entries, the nominal freestream unit Reynolds number was varied between 1.8×106 m-1 (0.5×106 ft-1) and 26.3×106 m-1 (8×106 ft-1). The nominal stagnation pressure was varied between 0.21 MPa and 3.33 MPa and the nominal stagnation temperature was varied between 480 K and 520 K to achieve the desired Re∞ condition. For all runs, the nominal freestream Mach number was 6. The nearly square test section is 520.7-mm (20.5-inches) wide by 508-mm (20-inches) high. Two 431.8-mm (17-inch) diameter windows made of Corning 7940, Grade 5F schlieren-quality glass serve as the side walls of the tunnel and provide optical access for the high-speed schlieren measurements. A rectangular window made of the same material as the side windows served as the top wall of the test section and provided optical access for the high-speed PSP and oil flow measurements. For the second entry, this top window was replaced with a Zinc Selenide (ZnSe) window with an anti-reflection coating capable of passing IR wavelengths between 8μm and 12μm with greater than 98% transmittance. The model was sting supported by a strut attached to a hydraulic system that allows for the model pitch angle to be adjusted between -5° to +55°. For the first entry, an initial pitch/pause sweep of the model AoA was performed to observe the resulting SWBLI. Ultimately, however, the sting pitch angle for this entry was fixed at +10.0° so that the angle of the top surface of the wedge relative to the streamwise axis of the tunnel (referred to herein as the plate angle, θplate), was θplate = 0°. For the second entry, θplate = 0° and θplate = -13.25° were initially tested with the swept ramp array (discussed in the following section) to determine which orientation produced conditions most favorable for XSWBLI to occur based on the heating signatures observed over the top surface of the model in the IR thermography images. Based on these initial tests, θplate = -13.25° was set for the remainder of the runs in the second entry. For both entries, any model changes were performed in a housing located beneath the closed test section. Prior to performing a run of the tunnel, the housing was sealed and the tunnel started. Once the appropriate freestream conditions were achieved, the model was injected into the test section using a hydraulic injection system. B. Model Geometry For all runs, a 10° half-angle (20° full-angle) wedge model with a sharp leading edge was used. The model is described in detail in Refs. [10,16]. The top surface of the sharp leading edge of the model extended 47.8 mm from its upstream-most edge to a junction with the upstream edge of a stainless steel top plate that then extended an (a) (c) (b) Fig. 1 (a) Schematic of top surface of wedge model with gas seeding insert, (b) perspective view of the model in the 20-Inch Mach 6 tunnel with centerline pressure orifices on sharp leading edge, and (c) a perspective view of the model with stainless steel (top) and SLA middle insert (bottom) during the first entry. Flow occurs from left to right.

Bathel, Brett F.↗

Boundary Layer Transition Induced by Distributed Roughness Array

The effects of a finite, spanwise-periodic array of cylindrical roughness elements on boundary layer transition over a NACA 0012 airfoil are investigated at a chord-based Reynolds number of 1.44×105 by using hotwire anemometry and infrared thermography. Both the number and the spanwise spacing of roughness elements in the array are varied in order to study their effect on the wake flow topology. Spanwise interaction between the roughness elements has an effect on the connection and the merging of neighbouring low-speed regions, which results in the formation of merged low-speed blobs (MLSs) that modify the spatial distribution and the amplitudes of the velocity streaks. When the spanwise distance between adjacent roughness elements equals 1.5 times the cylinder diameter, the transition location moves rapidly upstream. In this case, the two neighbouring low-speed regions overlap with each other in the near wake of the roughness, leading to the maximum growth in the velocity streak amplitude and the velocity fluctuations. The number of roughness elements affects the total number of MLSs within the boundary layer. For a single MLS behind a pair of cylinders, the Kelvin-Helmholtz instability dominates the growth of velocity fluctuations around the three-dimensional shear layers. When three cylinders are placed in the array, two MLSs appear in the near wake, which coalesce in to one low-speed blob downstream before the onset of transition, revealing the importance of Kelvin-Helmholtz instability.

Qingqing Ye↗

Heat Transfer Measurements and Computations on Blade of Variable Speed Power Turbine Blade Cascade

Heat transfer measurements were obtained on the blade surface of a two-dimensional section of a variable speed power turbine (VSPT) rotor blade in a linear cascade. Infrared thermography was used to determine the blade heat transfer distribution. Changes in the local heat transfer rates with Reynolds number were used to identify the laminar, turbulent, and transitional flow regimes, as well as to determine regions of flow separation. Steady-state data were obtained for six incidence angles ranging from 15.8° to –51.0°, and at five flow conditions for each angle.

Philip E Poinsatte↗

TPSAS-NF1676L-32030-DND

Composite structures are often difficult to inspect due to the anisotropic nature of the material systems and the range of flaws and defects that can arise in the manufacturing process. NASA?s Advanced Composites Project, a public-private partnership between government, universities and industry, seeks to address improved methods, tools, and protocols to reduce the development and certification timeline for composite materials and structures. The rapid inspection of composites is one of the three focused research areas of the project. One deliverable of the project is to develop an NDE Methods and Capabilities Handbook. This Handbook provides a publically available guidance document that facilitates the selection of appropriate NDE techniques and provides recommended protocols for detecting and characterizing common flaw types in solid laminate polymer matrix composite (PMC) structures. The Handbook will reduce the time required to develop qualified inspection processes for composite aircraft structures during the development, certification, and manufacturing phases by providing a reference that helps minimize trial and error and provides guidance on best practices, techniques, and settings, for specific flaw types and geometries. The Handbook will include an NDE Guidance Matrix that provides an applicability rating for NDE techniques as they apply to given flaw types. NDE techniques will include, but is not limited to ultrasound, laser based ultrasound, infrared thermography, and x-ray CT. Flaw types will include, but are not limited to porosity, delamination, voids, AFP defects and impact damage. The Handbook will contain details that support the applicability rating including, but not limited to, specimen details, inspection parameters, data analysis techniques, inspection efficiency (speed & cost), and limitations. This presentation will describe key Handbook activities with examples of the techniques and flaw types examined by the Advanced Composite Consortium members.

Patricia A Howell↗

NDE Methods and Capabilities Handbook – Resources for the Composites NDE Community

Composite structures are often difficult to inspect due to the anisotropic nature of the material systems and the range of flaws and defects that can arise in the manufacturing process. NASA’s Advanced Composites Project, a public-private partnership between government, universities and industry, sought to address improved methods, tools, and protocols to reduce the development and certification timeline for composite materials and structures. The rapid inspection of composites was one of the three focused research areas of the project. One deliverable of the project was to develop an NDE Methods and Capabilities Handbook. This Handbook provides a publicly available guidance document that facilitates the selection of appropriate NDE techniques and provides recommended protocols for detecting and characterizing common flaw types in solid laminate carbon fiber reinforced polymer composite (CFRP) structures. The Handbook seeks to reduce the time required to develop qualified inspection processes for composite aircraft structures during the development, certification, and manufacturing phases by providing a reference that helps minimize trial and error and provides guidance on best practices, techniques, and settings, for specific flaw types and geometries. NDE techniques include, but are not limited to ultrasound, laser based ultrasound, infrared thermography, and x-ray CT. Flaw types include, but are not limited to porosity, delamination, voids, AFP defects and impact damage. The Handbook contains details such as inspection parameters, data analysis techniques, inspection efficiency (speed & cost), and limitations. This presentation will describe key Handbook activities with examples of the techniques and flaw types examined by the Advanced Composite Consortium members. Availability of the fabricated NDE standards as well as the raw data collected on the standards by the Consortium members to the NDE community is discussed.

Patricia A Howell↗

Fluid-Thermal-Structural Interactions in Ramp-Induced Shock-Wave Boundary-Layer Interactions at Mach6

Shock-wave boundary-layer interactions (SWBLI) pose unique challenges for the slender airframes and sharp control surfaces characteristic of high-speed airbreathing aircraft. Spikes in pressure and thermal loading have been shown to occur in SWBLI regions; thus, predicting their location and behavior proves critical for assuring aircraft structural integrity and fatigue resilience. SWBLIs frequently lead to severe turbulent boundary-layer separation and corresponding unsteady motions characterized by a wide range of frequencies. Low-frequency motion has been shown to couple with the structure of a compliant panel, and turbulent boundary layers thus present a particular danger for thin control surfaces. Previous studies have shown that the thermal loading on a compliant panel in a ramp-induced SWBLI may have a signi cant impact on the panel vibrations. A multitude of studies has investigated the heating on rigid structures, but a charactrization of the heating effects on compliant structures is necessary to fully understand the fluid-thermal-structural interactions (FTSI) occurring in ramp-induced SWBLIs. This studuses infrared thermography and high-frequency Kulite pressure transducers to examine the heating loads on rigid and compliant ramps at various angles and flow conditions at Mach 6.

Hypersonic↗

NDE Methods and Capabilities Handbook - Resources for the Composites NDE Community

Composite structures are often difficult to inspect due to the anisotropic nature of the material systems and the range of flaws and defects that can arise in the manufacturing process. NASA’s Advanced Composites Project, a public-private partnership between government, universities and industry, sought to address improved methods, tools, and protocols to reduce the development and certification timeline for composite materials and structures. The rapid inspection of composites was one of the three focused research areas of the project. One deliverable of the project was to develop an NDE Methods and Capabilities Handbook. This Handbook provides a publicly available guidance document that facilitates the selection of appropriate NDE techniques and provides recommended protocols for detecting and characterizing common flaw types in solid laminate carbon fiber reinforced polymer composite (CFRP) structures. The Handbook seeks to reduce the time required to develop qualified inspection processes for composite aircraft structures during the development, certification, and manufacturing phases by providing a reference that helps minimize trial and error and provides guidance on best practices, techniques, and settings, for specific flaw types and geometries. Techniques include, but are not limited to ultrasound, laser based ultrasound, infrared thermography, and x-ray CT. Flaw types include, but are not limited to porosity, delaminations, voids, Automated Fiber Placement (AFP) defects and impact damage. The Handbook contains details such as inspection parameters, data analysis techniques, inspection efficiency and limitations. This presentation will describe key Handbook activities with examples of the techniques and flaw types examined by the Advanced Composite Consortium members. Availability to the NDE community of the fabricated NDE standards as well as the raw data collected on the standards by the Consortium members is discussed.

Nondestructive Evaluation↗

NDE Methods and Capabilities Handbook - Resources for the Composites NDE Community

Composite structures are often difficult to inspect due to the anisotropic nature of the material systems and the range of flaws and defects that can arise in the manufacturing process. NASA’s Advanced Composites Project, a public-private partnership between government, universities and industry, sought to address improved methods, tools, and protocols to reduce the development and certification timeline for composite materials and structures. The rapid inspection of composites was one of the three focused research areas of the project. One deliverable of the project was to develop an NDE Methods and Capabilities Handbook. This Handbook provides a publicly available guidance document that facilitates the selection of appropriate NDE techniques and provides recommended protocols for detecting and characterizing common flaw types in solid laminate carbon fiber reinforced polymer composite (CFRP) structures. The Handbook seeks to reduce the time required to develop qualified inspection processes for composite aircraft structures during the development, certification, and manufacturing phases by providing a reference that helps minimize trial and error and provides guidance on best practices, techniques, and settings, for specific flaw types and geometries. Techniques include, but are not limited to ultrasound, laser based ultrasound, infrared thermography, and x-ray CT. Flaw types include, but are not limited to porosity, delaminations, voids, Automated Fiber Placement (AFP) defects and impact damage. The Handbook contains details such as inspection parameters, data analysis techniques, inspection efficiency and limitations. This paper describes key Handbook activities with examples of the techniques and flaw types examined by the Advanced Composite Consortium members. Availability to the NDE community of the fabricated NDE standards as well as the raw data collected on the standards by the Consortium members is discussed.

nondestructive evaluation↗

Boundary layer transition measured by DIT on the PSP rotor in forward flight

A well-defined reference set of data for CFD and comprehensive code validation for a scaled helicopter main rotor with boundary layer transition in forward flight is presented (Fig. 1). The boundary layer transition was measured using differential infrared thermography (DIT) on the top (suction) side of the three-bladed NASA/Army “PSP rotor”, in the NASA Langley 14- by 22-Foot Subsonic Tunnel at an advance ratio of 0.3 (115kt).

Boundary layer transistion↗

Applications of Advanced Nondestructive Evaluation (NDE) and Structural Health Monitoring (SHM) Techniques to Address Safety of Flight Issues on NASA Spacecraft

Advanced NDE and SHM techniques are critical for ensuring the reliability and safety of NASA launch vehicles and spacecraft. NDE techniques such as infrared thermography, THz imaging, x-ray computed tomography and backscatter x-ray are used to detect indications of damage in spacecraft components and structures. Additionally, sensor and measurement systems are integrated into spacecraft to provide SHM to detect damaging events that occur during flight such as debris impacts during launch and assent or from micrometeoroid and orbital debris, or excessive loading due to anomalous flight conditions. A number of examples will be provided of how these NDE and SHM techniques have been applied to resolve safety critical inspection concerns for the Space Shuttle, International Space Station (ISS), and a variety of launch vehicles and unmanned spacecraft.

Advanced Nondestructive Evaluation (NDE)↗