Calculation of relaxing turbulent boundary layers downstream of tangential slot injection
Turbulent boundary layers calculation downstream of compressible relaxing slot injection flows, using finite difference method based on eddy viscosity model
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Turbulent boundary layers calculation downstream of compressible relaxing slot injection flows, using finite difference method based on eddy viscosity model
A warm gas thrust vector control system was studied to optimize the injection geometry for a specific engine configuration, and an injection valve was designed capable of meeting the base line requirements. To optimize injection geometry, studies were made to determine the performance effects of varying injection location, angle, port size, and port configuration. Having minimized the injection flow rate required, a warm gas valve was designed to handle the required flow. A direct drive hydraulic servovalve capable of operating with highly contaminated hydraulic fluid was designed. The valve is sized to flow 15 gpm at 3000 psia and the direct drive feature is capable of applying a spool force of 200 pounds. The baseline requirements are the development of 6 deg of thrust vector control utilizing 2000 F (total temperature) gas for 180 seconds on a 1.37 million pound thrust engine burning LOX and RP-1 at a chamber pressure of 250 psia with a 155 inch long conical nozzle having a 68 inch diameter throat and a 153 inch diameter exit.
Explore the source record for details and available documents.
Preliminary results are presented from an experimental evaluation of a hydrogen-burning wall-injection scramjet engine, performed in the free-piston shock tunnel at the Australian National University. The advantages of scramjet propulsion for high-Mach-number high-altitude flight are reviewed, and the need for an alternative to injection struts is indicated. Pressure profiles and heat-transfer measurements for constant-area and diverging ducts are presented graphically and characterized in detail. The ability of the injected flow to shield the chamber wall from the heat of the freestream flow is demonstrated. The extrapolation of the shock-tunnel results to flight conditions, however, is made difficult by the fact that a significant amount of fuel passes through a quenched zone without burning, seriously degrading overall performance.
Tests are performed to determine the effects of impinging oscillating shocks of different frequencies on a 15 deg downstream angled, underexpanded, sonic helium jet injected into a supersonic airflow. Information on mixing, penetration, total pressure loss, and turbulence structure from these tests is employed to estimate mixing control achieved by adding an oscillating shock to the helium injection flow field. The principal result of this study is that impingement of an oscillating shock on a high-speed shear layer can be utilized to control the rate of mixing.
Validation of Computational Fluid Dynamics (CFD) codes developed for prediction and evaluation of rocket performance is hampered by a lack of experimental data. Non-intrusive laser based diagnostics are needed to provide spatially and temporally resolved gas dynamic and fluid dynamic measurements. This paper reports the first non-intrusive temperature and species measurements in the plume of a 110 N gaseous hydrogen/oxygen thruster at and below ambient pressures, obtained with spontaneous Raman spectroscopy. Measurements at 10 mm downstream of the exit plane are compared with predictions from a numerical solution of the axisymmetric Navier-Stokes and species transport equations with chemical kinetics, which fully model the combustor-nozzle-plume flowfield. The experimentally determined oxygen number density at the centerline at 10 mm downstream of the exit plane is four times that predicted by the model. The experimental number density data fall between those numerically predicted for the exit and 10 mm downstream planes in both magnitude and radial gradient. The predicted temperature levels are within 10 to 15 percent of measured values. Some of the discrepancies between experimental data and predictions result from not modeling the three dimensional core flow injection mixing process, facility back pressure effects, and possible diffuser-thruster interactions.
The problems of asymmetric flow around slender bodies and its control are formulated using the unsteady, compressible, thin-layer or full Navier-Stokes equations which are solved using an implicit, flux-difference splitting, finite-volume scheme. The problem is numerically simulated for both locally-conical and three-dimensional flows. The numerical applications include studies of the effects of relative incidence, Mach number and Reynolds number on the flow asymmetry. For the control of flow asymmetry, the numerical simulation cover passive and active control methods. For the passive control, the effectiveness of vertical fins placed in the leeward plane of geometric symmetry and side strakes with different orientations is studied. For the active control, the effectiveness of normal and tangential flow injection and surface heating and a combination of these methods is studied.
The result of a literature search to consider what technologies should be represented in a totally automated water quality monitor for extended space flight is presented. It is the result of the first summer in a three year JOVE project. The next step will be to build a test platform at the Authors' school, St. John Fisher College. This will involve undergraduates in NASA related research. The test flow injection analysis system will be used to test the detection limit of sensors and the performance of sensors in groups. Sensor companies and research groups will be encouraged to produce sensors which are not currently available and are needed for this project.
The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simultaneously retracting dual-injector system in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors under dynamic stimuli from the continuous injection flow as well as from the stepped motion of the injectors. The final released drop must have a well determined volume and negligible residual linear or angular momentum. The outcome of Earth-based short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts. They were successfully utilized during the USML-1 Spacelab mission as the primary tips. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module range between 0.3 and 2.7 cm. The tests conducted on-orbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.
The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simuttaneously retracting dual-injector system used in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors even under dynamic stimuli due to continuous injection flow as well as to the stepped motion of the injectors, and the final released drop must have a well determined volume as well as negligible residual linear or angular momentum from the deployment process. The outcome of Earthbased short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts and were successfully utilized during the USML-1 Spacelab mission. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module ranged between 0.3 and 2.7 cm. The tests conducted onsrbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.
Continuous flow analysis was based on a steady sample flow and in-line detection of BC and other chemical substances as described in McConnell et al. (2007). In the cold room, previously cut one meter ice core sticks of 3x3cm, are melted continuously on a heated melter head specifically designed to eliminate contamination from the atmosphere or by the external parts of the ice. The melted ice from the most inner part of the ice stick is continuously pumped by a peristaltic pump and carried to a clean lab by Teflon lines. The recorded signal is continuous, integrating a sample volume of about 0.05 mL, for which the temporal resolution depends on the speed of melting, ice density and snow accumulation rate at the ice core drilling site. For annual accumulation derived from the WAIS and Law Dome ice cores, we assumed ~3.1 cm water equivalent uncertainty in each year's accumulation from short scale spatial variability (glaciological noise) which was determined from several measurements of annual accumulation in multiple parallel ice cores notably from the WAIS Divide ice core site (Banta et al., 2008) and from South Pole site (McConnell et al., 1997; McConnell et al., 2000). Refractory black carbon (rBC) concentrations were determined using the same method as in (Bisiaux et al., 2011) and adapted to continuous flow measurements as described by (McConnell et al., 2007). The technique uses a single particle intracavity laser induced incandescence photometer (SP2, Droplet Measurement Technologies, Boulder, Colorado) coupled to an ultrasonic nebulizer/desolvation (CETAC UT5000) Flow Injection Analysis (FIA). All analyses, sample preparation etc, were performed in a class 100 cleanroom using anti contamination "clean techniques". The samples were not acidified.
NASA’s Gateway will serve as an orbital outpost to enable sustained human lunar exploration and facilitate access to destinations beyond the Moon. To maintain sustainable deep space missions, on-orbit propellant transfer and refueling must be realized. One of Gateway’s critical components, the Power and Propulsion Element (PPE), will use solar electric propulsion to perform attitude control maneuvers and orbit transfers. Xenon will be used as the propellant for the PPE and stored in a composite overwrapped pressure vessel (COPV). During the propellant refueling process, xenon will compress causing the fluid and tank walls to warm. There is concern that the bond between the tank liner and composite may degrade at elevated temperatures, along with the possibility of the tank exceeding design pressure. While on-orbit testing is being proposed, numerical models are being used to predict the thermal response and reduce risk during a refueling operation in microgravity where natural convection is diminished. Accurate numerical models may be used to inform decisions for follow-on testing, or design and operation of refueling architectures. Challenges of modeling xenon tank fill in microgravity include non-ideal gas behavior, operating near the fluid’s critical point, and lack of experimental flight data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict averaged heat transfer coefficients during tank filling. At the anticipated injection flow rates, the CFD results showed that forced convection dominates in microgravity. Initial results from a multi-node Thermal Desktop model that assumed a purely conducting fluid (Nu=1) over-predicted the CFD fluid temperature and pressure, while a similar model allowing for natural convection under-predicted. The heat transfer coefficients predicted by CFD were implemented into the multi-node model, and the COPV thermal response from the two computational approaches were compared with good agreement.
On March 11, 2011, the Fukushima Daiichi Nuclear Power Plant, owned by Tokyo Electric Power Company, encountered a beyond design basis earthquake/tsunami and the flood crippled the on-site emergency power and electric transmission systems. The ELAP (Extended Loss of Alternating Current Power) and LUHS (Loss of Ultimate Heat Sink) events severely damaged the core cooling systems and the safety functions of the containment. As a result, three reactor cores were damaged. Also, the cooling capability of nuclear spent fuel pools was lost due to loss of AC and DC power. Existing Station Blackout (SBO) analyses have demonstrated that even with leakage from Reactor Coolant Pump (RCP) seals, the core could maintain coolable only when heat transfer exists between primary loop and secondary loop. Depend on the availability of DC power in different plant designs, the SBO coping times were shown to be 4 to 16 hours. According to INPO event report, it is necessary to analyze the consequences if current coping times are extended with increased core water inventory loss from pump seals. In an ELAP scenario, all active system including Emergency Core Cooling System (ECCS) and motor driven AFW were out of power supply, results in degradation of core cooling capability. Moreover, the fuel exposed risk would increase due to continuously Reactor Coolant System (RCS) inventory loss through pump seals. Therefore, mitigation strategy must be applied prior to core uncovering to prevent its damage and assure plant safety. This research utilized a fast running NPP safety simulation code, PCTRAN, to assess reactor performances in the situations of ELAP of Maanshan PWR. Also, the sensitivity study of injection flow rates and effectiveness of mitigation strategy were demonstrated. (authors)
In this chapter, we describe nanomaterial-based biosensors for detecting OP pesticides and explosives. CNTs and functionalized silica nanoparticles have been chosen for this study. The biosensors were combined with the flow-injection system, providing great advantages for onsite, real-time, and continuous detection of environmental pollutants such as OPs and TNT. The sensors take advantage of the electrocatalytic properties of CNTs, which makes it feasible to achieve a sensitive electrochemical detection of the products from enzymatic reactions at low potential. This approach uses a large aspect ratio of silica nanoparticles, which can be used as a carrier for loading a large amount of electroactive species, such as poly(guanine), for amplified detection of explosives. These methods offer a new environmental monitoring tool for rapid, inexpensive, and highly sensitive detection of OPs or TNT compounds.
The behavior of liquid nitrogen injected into a supersonic nitrogen flow field was investigated using an experimental apparatus in which a Mach 2.7 2D gas nitrogen tunnel is coupled with a high-pressure cryogenic source. Observations were monitored and recorded via a video camera and a motion picture camera. It was found that the penetration of a supersonic flow field by injection of liquid nitrogen is strongly dependent on the flow Mach number, the cryogen injection pressure (Pi/Pc), the injector configuration, and the cryogen temperature. For a 2D gaseous N2, Mach 2.7 tunnel, with cryogen injection Pi/Pc approaching 2, the injected fluid penetration for the 1/8-in. injection port approached one half of the tunnel width at 90-deg injection, and one fourth of the tunnel width at 20-deg injection.
A foot-scale high-temperature true-triaxial fracturing apparatus was used to conduct hydraulic fracture tests on rock samples. The fracturing tests used different fluids including water, CO2, CO2 with water, and CO2 with a 1% polyallylamine (PAA)/water solution. The tests were conducted with both constant pressure injection and constant flow rate injection modes. CO2-based fracturing fluids were found to produce higher breakdown pressures, high transient flow rates, and produce higher-conductivity fractures as compared to water-based fracturing fluids. Additionally, faster pressurization rates with CO2-based fracturing fluids (obtained when fracturing at constant flow rate mode) are found to be associated with higher fracture conductivities. When fracturing with CO2-based fluids in the presence of a PAA aqueous solution, for example if the rock is saturated with 1wt% PAA in water, the volume expansion caused by CO2-induced crosslinking of PAA leads to a faster pressure increase due to the associated volume expansion and increase in viscosity. It was also found that CO2 as a fracturing fluid injected in hot dry rock (HDR) attain the highest fracture conductivity only when injected at very high flow rates, followed very closely by the CO2/PAA fracturing fluid system that generates fractures with, on average, similarly high conductivity values though independently of injection flow rate and using 1/6 of the mass of CO2 as compared to CO2 in HDR. Breakdown pressures were also similar for CO2 stimulation in HDR and CO2/PAA fluid system under identical injection flow rates. Finally, the well-known low viscosity of CO2 phase prevents the efficient transport of proppants while the reacted CO2/PAA fluid system is known to form a high viscosity binary fracturing fluid system with the potential to carry proppant in addition of being a fine fracturing fluid.
This paper presents a technique to improve the Cross Correlation Function (CCF) method for indirect flow measurement. Unlike other methods, the CCF method does not need a specific instrument or tool for flow measurements. Instead, the delay time between two sensors can be derived by applying the CCF. A water flow loop was constructed to investigate the CCF method for flow measurement. Because the inherent process temperature variations were small when compared to significant amounts of measurement and process noise, inaccurate flow measurements were obtained. The performance of the CCF method could be improved by increasing the system signal-to-noise ratio, which is the process noise divided by the measurement noise. For this reason, a periodic injection of different temperature water was used to increase the process temperature variation. The results were favorable. However, several design variables needed to be selected. To assist, a CFD simulation was utilized to optimize the distance between sensors and injection point, the rate of injection flow, and other related variables. The results show that CCF optimization of these variables produces better flow measurement performance over a range of flow velocities. (authors)
Abstract not provided.