Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumental resolution function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global centroid moment tensor solutions in a heterogeneous earth: the CMT3D catalogue

SUMMARY For over 40 yr, the global centroid-moment tensor (GCMT) project has determined location and source parameters for globally recorded earthquakes larger than magnitude 5.0. The GCMT database remains a trusted staple for the geophysical community. Its point-source moment-tensor solutions are the result of inversions that model long-period observed seismic waveforms via normal-mode summation for a 1-D reference earth model, augmented by path corrections to capture 3-D variations in surface wave phase speeds, and to account for crustal structure. While this methodology remains essentially unchanged for the ongoing GCMT catalogue, source inversions based on waveform modelling in low-resolution 3-D earth models have revealed small but persistent biases in the standard modelling approach. Keeping pace with the increased capacity and demands of global tomography requires a revised catalogue of centroid-moment tensors (CMT), automatically and reproducibly computed using Green's functions from a state-of-the-art 3-D earth model. In this paper, we modify the current procedure for the full-waveform inversion of seismic traces for the six moment-tensor parameters, centroid latitude, longitude, depth and centroid time of global earthquakes. We take the GCMT solutions as a point of departure but update them to account for the effects of a heterogeneous earth, using the global 3-D wave speed model GLAD-M25. We generate synthetic seismograms from Green's functions computed by the spectral-element method in the 3-D model, select observed seismic data and remove their instrument response, process synthetic and observed data, select segments of observed and synthetic data based on similarity, and invert for new model parameters of the earthquake’s centroid location, time and moment tensor. The events in our new, preliminary database containing 9382 global event solutions, called CMT3D for ‘3-D centroid-moment tensors’, are on average 4 km shallower, about 1 s earlier, about 5 per cent larger in scalar moment, and more double-couple in nature than in the GCMT catalogue. We discuss in detail the geographical and statistical distributions of the updated solutions, and place them in the context of earlier work. We plan to disseminate our CMT3D solutions via the online ShakeMovie platform.

58 GEOSCIENCES↗

Thallium-based scintillators for high-resolution gamma-ray spectroscopy: Ce 3+ - doped Tl 2 LaCl 5 and Tl 2 LaBr 5

In this paper we report on the crystallographic and scintillation properties of Tl 2 LaCl 5 :Ce 3 + and Tl 2 LaBr 5 :Ce 3 + , two novel thallium-containing high-resolution scintillators for gamma-ray spectroscopy. Crystals of Tl 2 LaCl 5 :Ce 3 + and Tl 2 LaBr 5 :Ce 3 + were grown by the Vertical Bridgman method up to 1-inch diameter and 1-inch long. Single crystals of Tl 2 LaCl 5 :Ce 3 + and Tl 2 LaBr 5 :Ce 3 + belong to the orthorhombic system with space group 62 and have a density of 5.16 and 5.98 g/cm 3 , respectively. The scintillators show high light yields of up to 68,000 photons/MeV, excellent gamma-ray energy resolution of ≤ 3% at 662 keV, a fast scintillation decay, and a proportional response over a wide range of energies from 32 keV up to 1275 keV. Density Functional Theory calculations show that the Ce 3 + energy levels are inside the bandgap despite the smaller bandgap of Tl 2 LaCl 5 and Tl 2 LaBr 5 compared to K 2 LaCl 5 and K 2 LaBr 5 . Finally, a systematic Ce 3 + concentration study was performed for Tl 2 LaCl 5 :Ce 3 + and trends observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Doppler velocimetry surface return study for common surface preparations

Photon Doppler velocimetry (PDV) is a ubiquitous diagnostic method in dynamic compression experiments. It typically requires the roughening of the test surface to ensure scattering of the probe light back into the PDV probe at non-normal angles of incidence. Although surface scattering plays an essential role in the quality of PDV data, surface scattering properties for common materials and preparations have not previously been studied with specific relevance to PDV. Here, we present detailed measurements of the bidirectional reflectance distribution function for four different surface preparations (Scotch-Brite hand and drill roughened, ball-rolled, and grit blasted) and four different materials (copper, aluminum, stainless steel, and tantalum). These measurements employ a conventional PDV probe and obtain a diffraction limited angular resolution with 10 pW accuracy and 2.6% repeatability. In addition to scattering data, we employ scattering theory and simulations to accurately emulate the measured data. We also present a straightforward method to derive the average scattering distribution from surface profilometry and observe several qualitative aspects of the scattering data that may help to optimize PDV signals.

42 ENGINEERING↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Instrumentation and experimental procedures for robust collection of X-ray diffraction data from protein crystals across physiological temperatures

Traditional X-ray diffraction data collected at cryo-temperatures have delivered invaluable insights into the three-dimensional structures of proteins, providing the backbone of structure–function studies. While cryo-cooling mitigates radiation damage, cryo-temperatures can alter protein conformational ensembles and solvent structure. Furthermore, conformational ensembles underlie protein function and energetics, and recent advances in room-temperature X-ray crystallography have delivered conformational heterogeneity information that can be directly related to biological function. Given this capability, the next challenge is to develop a robust and broadly applicable method to collect single-crystal X-ray diffraction data at and above room temperature. This challenge is addressed herein. The approach described provides complete diffraction data sets with total collection times as short as ~5 s from single protein crystals, dramatically increasing the quantity of data that can be collected within allocated synchrotron beam time. Its applicability was demonstrated by collecting 1.09–1.54 Å resolution data over a temperature range of 293–363 K for proteinase K, thaumatin and lysozyme crystals at BL14-1 at the Stanford Synchrotron Radiation Lightsource. Here, the analyses presented here indicate that the diffraction data are of high quality and do not suffer from excessive dehydration or radiation damage.

36 MATERIALS SCIENCE↗

Broadband Rotational Spectroscopy in Uniform Supersonic Flows: Chirped Pulse/Uniform Flow for Reaction Dynamics and Low Temperature Kinetics

ConspectusThe study of gas-phase chemical reactions at very low temperatures first became possible with the development and implementation of the CRESU (French acronym for Reaction Kinetics in Uniform Supersonic Flows) technique. CRESU relies on a uniform supersonic flow produced by expansion of a gas through a Laval (convergent-divergent) nozzle to produce a wall-less reactor at temperatures from 10 to 200 K and densities of 1016-1018 cm-3 for the study of low temperature kinetics, with particular application to astrochemistry. In recent years, we have combined uniform flows with revolutionary advances in broadband rotational spectroscopy to yield an instrument that affords near-universal detection for novel applications in photodissociation, reaction dynamics, and kinetics. This combination of uniform supersonic flows with chirped-pulse Fourier-transform microwave spectroscopy (Chirped-Pulse/Uniform Flow, CPUF) permits detection of any species with a modest dipole moment, thermalized to the uniform temperature of the gas flow, with isomer, conformer, and vibrational state specificity. In addition, the use of broadband, high-resolution, and time-dependent (microsecond time scale) micro- and mm-wave spectroscopy makes it an ideal tool for characterizing both transient and stable molecules, as well as studying their spectroscopy and dynamics.In this Account, we review recent advances made using the CPUF technique, including studies of photodissociation, radical-radical reaction dynamics, and low temperature kinetics. These studies highlight both the strength of universal and multiplexed detection and the challenges of coupling it to a high-density collisional environment. Product branching and product evolution as a function of time have been measured for astrochemically relevant systems, relying on the detailed characterization of these flow conditions via experiments and fluid dynamics simulations. In the photodissociation of isoxazole, an unusual heterocyclic molecule with a very low-energy conical intersection, we have identified 7 products in 5 reaction channels and determined the product branching, pointing to both direct and indirect pathways. We have also approached the same system from separated NO and C3H3 reactants to explore a broader range of the potential energy surface, demonstrating the power of multichannel branching measurements for complex radical-radical reactions. We determined the product branching in the C3H2 isomers in the photodissociation of the propargyl radical and identified the importance of a hydrogen atom catalyzed isomerization to the lowest energy cyclic form. This then motivated a study of direct D-H exchange reaction in radicals, in which we demonstrate that it is an important and overlooked pathway for deuterium fractionation in astrochemical environments. Recently, we have shown the measurement of low temperature kinetics inside an extended Laval nozzle, after which a shock-free secondary expansion to low temperature and density affords an ideal environment for detection by rotational spectroscopy. These results highlight the power and potential of the CPUF approach, and future prospects will also be discussed in light of these developments.

Dias, Nureshan↗

DESI mock challenge: constructing DESI galaxy catalogues based on FastPM simulations

Together with larger spectroscopic surveys such as the Dark Energy Spectroscopic Instrument (DESI), the precision of large-scale structure studies and thus the constraints on the cosmological parameters are rapidly improving. Therefore, one must build realistic simulations and robust covariance matrices. We build galaxy catalogues by applying a halo occupation distribution (HOD) model upon the FastPM simulations, such that the resulting galaxy clustering reproduces high-resolution N-body simulations. While the resolution and halo finder are different from the reference simulations, we reproduce the reference galaxy two-point clustering measurements – monopole and quadrupole – to a precision required by the DESI Year 1 emission line galaxy sample down to non-linear scales, i.e. $k\lt 0.5\, h\, \mathrm{Mpc}^{-1}$ or $s\gt 10\, \mathrm{Mpc}\, h^{-1}$. Furthermore, we compute covariance matrices based on the resulting FastPM galaxy clustering – monopole and quadrupole. We study for the first time the effect of fitting on Fourier conjugate (e.g. power spectrum) on the covariance matrix of the Fourier counterpart (e.g. correlation function). We estimate the uncertainties of the two parameters of a simple clustering model and observe a maximum variation of 20 per cent for the different covariance matrices. Nevertheless, for most studied scales the scatter is between 2 and 10 per cent. Consequently, using the current pipeline we can precisely reproduce the clustering of N-body simulations and the resulting covariance matrices provide robust uncertainty estimations against HOD fitting scenarios. We expect our methodology will be useful for the coming DESI data analyses and their extension for other studies.

79 ASTRONOMY AND ASTROPHYSICS↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗

Milestone report for MRT 8479: High Yield Xray Imager Preliminary Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi-MJ yield shots. Also, a new radiation tolerance CMOS imaging array is being developed to eliminate the significant background noise which limits the data quality of PDIXI. The HYXI Preliminary Design Review was completed at the end of Q4 FY23. The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the new CMOS imaging array. Initial time integrated NIF data will be collected in Q2 FY25, first time resolved imaging with Daedalus starting in Q2 FY26 and the final performance qualification of the complete HYXI system is scheduled for Q2 FY27.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis, Processing, and Use of Isotopically Enriched Epitaxial Oxide Thin Films

Isotopic engineering has emerged as a key approach to study the nucleation, diffusion, phase transitions, and reactions of materials at an atomic level. It aims to uncover mass transport pathways, kinetics, and operational and failure mechanisms of functional materials and devices. Understanding these phenomena leads to deeper insights into important physical processes, such as the transport of ions in energy conversion and storage devices and the role of active sites and supports during heterogeneous catalytic reactions. Likewise, isotopic engineering is being pursued as a means of modifying functionality to enable future technological applications. In this Account, we summarize our recent work employing isotope labeling (e.g., 18 O 2 and 57 Fe) during thin film synthesis and postgrowth processing to reveal growth mechanisms, defect chemistry, and elemental diffusion under working and extreme conditions. Isotope-resolved analysis techniques with nanometer-scale spatial resolution, such as time-of-flight secondary ion mass spectrometry and atom probe tomography, facilitate the accurate quantification of isotopic placement and concentration in our well-defined heterostructures with precisely positioned, isotope-enriched layers. By measuring the nanometer-scale redistribution between natural abundance and isotopically enriched oxygen layers during the deposition of Fe 2 O 3 and Cr 2 O 3 by molecular beam epitaxy, we identified intermixing processes driven by surface adatoms occurring both at the film growth surface and within the first few layers below the surface. Further insights into synthesis mechanisms were gained by studying the tungsten oxide thin films grown by evaporating WO 3 powder in the presence of background 18 O 2 , revealing minimal incorporation of background oxygen during the film formation process. Thermal and radiation-enhanced diffusion in epitaxial Fe and Cr oxides were precisely tracked using 18 O and 57 Fe tracer layers incorporated into model epitaxial oxide thin films. This approach has allowed us to access thermal diffusion behavior at lower temperatures than previously measured, revealing a potential changeover in diffusion mechanism. Understanding radiation-enhanced diffusion in model oxides that represent the surface layers on the structural components of nuclear reactors informs our understanding of their corrosion behavior under irradiation. Isotopic labeling can also provide unique insights into the surface exchange reactions and defect chemistry of electrocatalysts. For instance, tracking the change in 18 O concentration at the surface of an epitaxial LaNiO 3 thin film after the electrocatalytic oxygen evolution reaction revealed the participation of lattice oxygen, confirming a hypothesis that had been proposed previously. Lastly, we highlight a new direction wherein we perform in situ processing studies utilizing isotopic tracers in conjunction with model epitaxial thin films within the atom probe tomography instrument. Additionally, this Account illustrates the great potential of isotopic engineering to enable fundamental mechanistic insights into physical processes and engineer functional properties in epitaxial films, heterostructures, and superlattices.

36 MATERIALS SCIENCE↗

Strong Correspondence in Evapotranspiration and Carbon Dioxide Fluxes Between Different Eddy Covariance Systems Enables Quantification of Landscape Heterogeneity in Dryland Fluxes

Abstract The eddy covariance method is widely used to investigate fluxes of energy, water, and carbon dioxide at landscape scales, providing important information on how ecological systems function. Flux measurements quantify ecosystem responses to environmental perturbations and management strategies, including nature‐based climate‐change mitigation measures. However, due to the high cost of conventional instrumentation, most eddy covariance studies employ a single system, limiting spatial representation to the flux footprint. Insufficient replication may be limiting our understanding of ecosystem behavior. To address this limitation, we deployed eight lower‐cost eddy covariance systems in two clusters around two conventional eddy covariance systems in the Chihuahuan Desert of North America for a period of 2 years. These dryland settings characterized by large temperature variations and relatively low carbon dioxide fluxes represented a challenging setting for eddy covariance. We found very good closure of energy and water balance across all systems (within ±9% of unity). We found very good correspondence between the lower‐cost and conventional systems' fluxes of sensible heat (with concordance correlation coefficient (CCC) of ≥0.87), latent energy (evapotranspiration; CCC ≥ 0.89), and useful correspondence in the net ecosystem exchange ((NEE); with CCC ≥ 0.4) at the daily temporal resolution. Relative to the conventional systems, the low‐frequency systems were characterized by a higher level of random error, particularly in the NEE fluxes. Lower‐cost systems can enable wider deployment affording better replication and sampling of spatiotemporal variability at the expense of greater measurement noise that might be limiting for certain applications. Replicated eddy covariance observations may be useful when addressing gaps in the existing monitoring of critical and underrepresented ecosystems and for measuring areas larger than a single flux footprint.

54 ENVIRONMENTAL SCIENCES↗

Survey of Surveys: I. The largest compilation of radial velocities for the Galaxy

In the present-day panorama of large spectroscopic surveys, the amount, diversity, and complexity of the available data continuously increase. The overarching goal of studying the formation and evolution of our Galaxy is hampered by the heterogeneity of instruments, selection functions, analysis methods, and measured quantities. Here, we present a comprehensive catalogue, the Survey of Surveys (SoS), built by homogeneously merging the radial velocity (RV) determinations of the largest ground-based spectroscopic surveys to date, such as APOGEE, GALAH, Gaia-ESO, RAVE, and LAMOST, using Gaia as a reference. This pilot study serves to prove the concept and to test the methodology that we plan to apply in the future to the stellar parameters and abundance ratios as well. We have devised a multi-staged procedure that includes: (i) the cross match between Gaia and the spectroscopic surveys using the official Gaia cross-match algorithm, (ii) the normalisation of uncertainties using repeated measurements or the three-cornered hat method, (iii) the cross calibration of the RVs as a function of the main parameters on which depend (magnitude, effective temperature, surface gravity, metallicity, and signal-to-noise ratio) to remove trends and zero point offsets, and (iv) the comparison with external high-resolution samples, such as the Gaia RV standards and the Geneva-Copenhagen survey, to validate the homogenisation procedure and to calibrate the RV zero-point of the SoS catalogue. We provide the largest homogenised RV catalogue to date, containing almost 11 million stars, of which about half come exclusively from Gaia and half in combination with the ground-based surveys. We estimate the accuracy of the RV zero-point to be about 0.16–0.31 km s –1 and the RV precision to be in the range 0.05–1.50 km s –1 depending on the type of star and on its survey provenance. We validate the SoS RVs with open clusters from a high resolution homogeneous samples and provide the systemic velocity of 55 individual open clusters. Additionally, we provide median RVs for 532 clusters recently discovered by Gaia data. The SoS is publicly available and ready to be applied to various research projects, such as the study of star clusters, Galactic archaeology, stellar streams, or the characterisation of planet-hosting stars, to name a few. We also plan to include survey updates and more data sources in future versions of the SoS.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Fourier-based methods for removing mesh anomalies from angle resolved photoemission spectra

Recent improvements to spatial resolution in angle-resolved photo-emission spectroscopy (ARPES) have made it common to perform measurements with a very brief dwell time, for the purpose of mapping the spectral function over large surface regions. However, rapid measurement modalities can suffer a grid-like intensity modulation due to a wire mesh that is typically placed in front of the ARPES detector to block stray electrons. Here, we explore Fourier-based methods that can effectively remove this artifact, and improve the quality of ARPES images obtained in rapid scanning modes. In conclusion, an open source software package is provided containing implementations of demonstrated algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer

We present a model and numerical simulation of a distributed temperature sensor based on a two-pulse differential coherent optical time-domain reflectometer (COTDR). The differential phase measured using a phase-sensitive Rayleigh reflectometer is shown to have a regular component, which is a linear function of temperature, and a random component, which is related to a random distribution of scattering centres in the fibre and restricts the accuracy of measurements of variations in temperature. Measurement accuracy can be improved by reducing the relative contribution of the random component via a decrease in pulse duration and/or an increase in the time delay between pulses. The spatial resolution of a differential two-pulse phase-sensitive reflectometer is shown to be determined by the time delay between pulses and to vary little with pulse duration. At a typical pulse duration (200 ns) and delay time (300 ns), the accuracy in measurements of variations in temperature in the 0.1-K range is 2 % and the spatial resolution is about 30 m. (fibre-optic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated detector simulation and reconstruction parametrization using machine learning

Rapidly applying the effects of detector response to physics objects (e.g. electrons, muons, showers of particles) is essential in high energy physics. Presently available tools for the transformation from truth-level physics objects to reconstructed detector-level physics objects involve manually defining resolution functions. These resolution functions are typically derived in bins of variables that are correlated with the resolution (e.g. pseudorapidity and transverse momentum). This process is time consuming, requires manual updates when detector conditions change, and can miss important correlations. Machine learning offers a way to automate the process of building these truth-to-reconstructed object transformations and can capture complex correlation for any given set of input variables. Such machine learning algorithms, with sufficient optimization, could have a wide range of applications: improving phenomenological studies by using a better detector representation, allowing for more efficient production of Geant4 simulation by only simulating events within an interesting part of phase space, and studies on future experimental sensitivity to new physics.

47 OTHER INSTRUMENTATION↗