Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumentation development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

MethodOpt: a Shiny-based graphical user interface for multivariate optimization of sampling and analytical instrumentation

Method optimization is an important step in producing useful data in various experimental settings involving the use of sampling and analytical instrumentation, such as gas-chromatography mass-spectrometry or other analytical techniques. However, traditional optimization techniques often lack the sophistication of more modern optimization techniques developed in areas of applied mathematics. A graphical user interface has been developed that implements a multivariate, multi-objective optimization technique for spectra-generating sampling and analytical instrumentation, which saves substantial time and resources compared to the more traditional approaches to method development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exocortex Network for AI-Augmented Human-Led Scientific Expedition

AI advances in science can be viewed along two main directions with a fluid boundary: enhancing efficiency through automation and smart tools to accelerate tasks that humans can already perform; and enabling exploration into uncharted territories and potentially toward AGI. These advances manifest in the AI cognitive core through the development and explainability of foundation models; in the physical embodiment of instruments and facilities; and in the integrated agency of AI workflows exemplified by the science exocortex. To address the role of humans in this evolving landscape, in this Perspective, we suggest a third direction: the development of personalized agents that form human-centered networks, supporting both efficiency and exploration while ensuring that AI remains aligned with human vision.

97 MATHEMATICS AND COMPUTING↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Monte Carlo Simulation with CAD Interface for Calculation of 3D Maps of Residual Dose (CRADA)

Objective: To develop an easy-to-use software application to predict and mitigate radiation effects in research environment, space instruments, nuclear plants and medical facilities and help nonproliferation and national security efforts. Tech-X will develop standalone software libraries and command-line tools for ( 1) translating CAD into tessellated surfaces and tetrahedral meshes in GDML (for Geant4 and MARS 15), ROOT (for MARS 15) and HDF5 (for compact representation and for the visualization) formats, (2) healing CAD geometries to make them suitable for Monte Carlo simulations; (3) creating uniform and variable Cartesian and cylindrical meshes for detailed scoring; and ( 4) efficient Monte Carlo navigation in CAD geometries. JLAB will finish automation of simulations of residual dose in CAD geometries and integrate Tech-X software into Geant4 and MARS15. Finally, Tech-X will develop a Graphical User Interface to set up and heal CAD geometries, create input files, run and visualize simulations for residual dose. This application will run on local desktops, local and remote clusters and supercomputers and will be made available through public clouds, such as Amazon Web Services.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation and Control Digital Modernization Research Plan for Long-Term Sustainability in the Nuclear Industry

This report, developed by Idaho National Laboratory (INL) in collaboration with Oak Ridge National Laboratory (ORNL), outlines a comprehensive research plan to support the digital modernization of safety-related instrumentation and control (I&C) systems in the U.S. nuclear industry. The modernization effort is critical to ensuring the long-term safety, reliability, and economic viability of both existing and future nuclear power plants (NPPs), particularly as aging analog systems become increasingly obsolete and difficult to maintain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design-to-Deployment Continuum Platform for Microscopes and Computing Ecosystems

Science ecosystems with networked computing systems and physical instruments are increasingly being deployed with a goal to achieve the productivity promised by AI-supported remote automation. In support of these efforts, the virtual infrastructure twins (VITs) have been successfully utilized to develop the orchestration codes for these ecosystems without requiring physical access to expensive instruments, such as electron microscopes. Currently, the utility of such a VIT is severely limited by the computing capacity and capability of the computing system used as its host. Furthermore, codes developed on the VIT typically need to be transferred and refactored for production use, particularly, on high-performance systems with accelerators. In response, we develop a design-to-deployment continuum platform wherein a VIT runs natively on the ecosystem's own computing system, and thereby facilitates the continual in-situ testing and transition of codes for production use. Here, we describe the development and testing of software for remote microscope steering and GPU-based image reconstruction using this platform on a multi-GPU computing system networked to Nion microscopes. We demonstrate a continual transition of steering and reconstruction codes developed under VIT platform to production ecosystem deployment.

Al-Najjar, Anees [Oak Ridge National Laboratory (O↗

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic separation of gases using microsieves

Separation of light weight molecules, such as nitrogen, argon, and oxygen, from heavier compounds can have significant impacts on energy capture, environmental monitoring, or isotopic applications. Large-scale gas separation techniques, like gas centrifugation and membrane mitigation, can be problematic as they impart tremendous energy and induce high mechanical stress onto the instrumentation. Microsieves, also known as micronozzles or microfunnels, are developed to create physical barriers to separate specific isotopes and gases. Separation is achieved using a converging and diverging micronozzle to impose supersonic gas flow around a curved wall, and it has been used for the separation of heavy actinide isotopes in low weight gas as well as separation of low weight gas compositions of nitrogen and argon back in 1900s. However, systematic reviews of this unique technology are lacking. The application of the Laval style nozzle, which has a converging/diverging entrance fundamental to the micronozzle, is included in this review due to its importance in industrial applications in uranium (U) isotope refinement. Using advanced computational fluid dynamic (CFD) simulations, the extent of gas separation can be modelled. Herein, we first examine the literature and survey recent advances on fabrication techniques for creating curved micronozzles, methods and separation principles used to design devices. Furthermore, we then follow with highlights of CFD simulations applied to evaluate the separation effects using microsieves. Finally, identification of the gap and recommendation for future development and applications are suggested for using intrinsic molecular features and fluidic dynamics in formulating separation strategies.

30 Microfluidics↗

Supplementing biofuel mandates with a carbon mitigation policy can lead to water quality co-benefits

Biofuel mandates can impact the environment in multiple ways that may be positive or negative, including affecting life-cycle greenhouse gas (GHG) emissions by displacing fossil fuels, affecting soil carbon stocks due to accompanying land use change, and water quality due to changes in fertilizer requirements and the mix of crops used as feedstocks. To achieve desired environmental outcomes in the presence of a biofuel mandate, additional policy instruments must be adopted to supplement the mandate. We develop an integrated and spatially explicit ecosystem-economic modeling framework to analyze the cost-effectiveness of alternative policies to achieve desired targets for GHG emissions reduction from the agricultural and fuel sectors in the USA and nitrate leaching reduction in the Gulf of Mexico below the levels that would be achieved by a corn ethanol and/or a cellulosic ethanol mandate in the USA. We find that while a corn ethanol mandate lowers GHG emissions, it increases nitrate leaching due to the expansion of corn production; a cellulosic ethanol mandate lowers both GHG emissions and nitrate leaching relative to a corn ethanol mandate, but the additional carbon and nitrate prices are needed to achieve anticipated GHG reduction and nitrate reduction targets. We also find that accompanying a biofuel mandate with a GHG reduction target alone leads to substantial nitrate reduction co-benefits, but a nitrate reduction target alone is less effective in reducing GHG emissions. Combining a GHG standard with a nitrate standard can achieve GHG and nitrate reduction targets at lower carbon and nitrate prices as compared to implementing each of these policies independently. Furthermore, our findings show that disregarding policy co-benefits can overestimate the GHG and nitrate prices needed to achieve policy targets and higher policy costs.

09 BIOMASS FUELS↗

Advanced Computational Modeling of High-Level Waste Vitrification at the Hanford Site

The U.S. Department of Energy (DOE) has selected vitrification for stabilizing legacy tank waste at the Hanford site, where radioactive waste from plutonium production was historically stored in underground tanks. This waste will be separated into low-activity waste (LAW) and high-level waste (HLW) fractions and processed at the Waste Treatment and Immobilization Plant (WTP). At WTP, glass melters are used for the vitrification of radioactive tank waste, transforming it into a stable borosilicate glass form for safe long-term storage. The melter vessel is constructed from highly durable and heat-resistant materials, where the vitrification process occurs. The main regions that are modeled are the melt pool, plenum, cold cap, riser/discharge chamber, and surrounding structure with insulation layers. Forced convection induced by air bubblers at the base of the melter ensure uniform temperature distribution and provide heat to the cold cap layer. The cold cap is a region of reacting batch feed that floats on top of the molten glass and is where the batch-to-glass reactions occur. Joule heating provided by electrodes mounted along the vertical walls of the melter and immersed directly in the glass, generates the necessary heat for the net endothermic conversion processes that occur in the cold cap. The high temperatures, radioactivity, and opaque nature of the glass prevent direct observation inside the melters. Therefore, computational models are essential for providing insight into factors that affect melter throughput. Thermocouples in the plenum provide operators with plenum temperature measurements. Operational adjustments include bubbling rate, voltage supplied to the electrodes, feed adjustments, and glass removal rate. Different computational fluid dynamics (CFD) models have been developed, each serving a specific purpose. There are CFD models of different scale melters, as well as models that capture the two-phase flow interfaces of rising bubbles in the molten glass or models with a simplified molten glass region so that the surrounding structure and plenum can be feasibly incorporated. Pilot-scale melter models have been developed to serve as validation of the methods employed in the simulation of the full-scale WTP melters. Models incorporating resolved bubbling are used to develop momentum source terms to implement into a single phase, multi-region, steady-state flow model that is being validated by measured process parameters such as glass production rate, voltage, input power, plenum temperatures, etc. The resolved bubbling model uses the multiphase volume of fluid approach to model the system with a high-resolution interface capturing scheme to maintain sharp interfaces between the molten glass and the air phase. The suite of CFD models is continually being improved to incorporate more realistic physics and achieve faster turnaround time. For example, an incremental controller is implemented to automatically adjust electrode voltage within the simulation to a molten glass set point temperature of 1150°C. Newer models feature improved meshes to ensure conformal meshes between regions and eliminate unnecessary mesh refinement in areas that are not of interest (such as boundary layers in offgas ports). Instead of explicitly modeling the structural, refractory, and insulation layers of the melter, a thermal resistance approach is used with published correlations used for boundary conditions. The development of robust and efficient CFD models will be instrumental in enabling the WTP to successfully fulfill its mission of safely stabilizing legacy nuclear waste.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Validation and demonstration of the AEFC as a practical safeguards tool for inventory verification

The Advanced Experimental Fuel Counter (AEFC) is a nondestructive assay (NDA) instrument designed to determine the residual fissile mass in irradiated fuel assemblies for safeguards verification purposes. This is done by actively interrogating an assembly with a neutron source and measuring the total (Singles) and correlated (Doubles) neutron count rates resulting from induced fissions in the irradiated nuclear fuel and relating those rates to the residual fissile mass using calibration curves. Comprehensive NDA measurements of the irradiated fuel inventory at Israeli Research Reactor 1 (IRR-1) were taken with the AEFC to validate a set of previously developed calibration curves. During the campaign, measurements were acquired of 32 standard fuel assemblies and three control assemblies in just nine days. This is a significant majority of the research reactor's irradiated fuel inventory and the largest data set gathered by the AEFC to date. Many of the fuel assemblies measured during the campaign had much shorter cooling times than those assemblies previously measured with the instrument. Calibration curves developed from previous AEFC deployments were used to determine the residual 235 U mass in the measured standard fuel assemblies. The results of the campaign demonstrated that the AEFC can be used to estimate the 235 U mass remaining in a large number of irradiated fuel assemblies with 1%–5% uncertainty in a reasonable amount of time despite operating in a high dose environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Performance and Reliability Assessment of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Data Advisor (ADA)

The Atmospheric Radiation Measurement (ARM) User Facility provides one of the world's largest openly accessible repositories of atmospheric observations through the ARM Data Discovery platform. Although the repository contains more than three decades of measurements collected from permanent observatories, mobile facilities, aircraft campaigns, and field experiments, identifying appropriate datasets can be challenging, particularly for new users unfamiliar with ARM instrumentation and datastream organization. To improve data accessibility, the ARM Data Center developed the ARM Data Advisor (ADA), an artificial intelligence-powered assistant designed to facilitate scientific data discovery, dataset interpretation, and user guidance. This report evaluates ADA's performance as a domain-specific scientific assistant using realistic atmospheric science workflows. The evaluation examines five key capabilities: data retrieval and curation efficiency, hallucination resistance, scientific reasoning, response to ambiguous queries, and content retention and session continuity. Representative prompts were developed to simulate typical interactions between researchers and the ARM Data Discovery platform, and ADA's responses were assessed for retrieval completeness, scientific accuracy, consistency, and practical usefulness. In these representative tests, ADA reduced the complexity of discovering and accessing ARM datasets by recommending appropriate datastreams, explaining instrumentation, interpreting metadata, and assisting with data processing workflows. ADA also exhibits strong domain knowledge of atmospheric science terminology and generally resists hallucination by acknowledging unavailable datasets and requesting clarification when appropriate. Overall, the results indicate that ADA represents a promising advancement in scientific data discovery within the ARM User Facility and has considerable potential to improve researcher productivity, particularly for new users and interdisciplinary scientists seeking efficient access to ARM observations.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Development and validation of a humidified CAPS-PMSSA with an improved methodology to calculate the truncation correction factor

Absorbing aerosols play an important role in the Earth’s radiation budget, and current uncertainties associated with their radiative impacts remain substantial. An element of this uncertainty derives from insufficient understanding of the extent to which water, as a coating on absorbing particles, enhances the absorption. Here, we describe and characterize the performance of a cavity-attenuated phase shift single scatter albedo spectrometer (CAPS-PMSSA) system that has been modified to enable concurrent aerosol extinction and scattering measurements, from which aerosol absorption is derived, at relative humidities up to ~90%. The modified instrument is referred to as the humidified CAPS (HCAPS). Additionally, we develop and validate an update to a method to calculate the truncation correction factor, used to correct the scattering measurements, that can account for the effects of particle growth and compositional changes resulting from water uptake. The method can be applied to experiments that use either size-selected or polydisperse aerosol samples of either known or unknown composition. Overall, we show that measurements made with the HCAPS, when processed using the updated truncation correction method, enable accurate measurement of the influence of water uptake on light absorption.

Dal Porto, Rachael [University of California, Davi↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗