Search NASA⌕ Search

SEARCH · Search NASA

Results for “instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Redis-Based Streaming Architecture for Accelerator Beam Instrumentation DAQ Systems

The Fermilab Acceleraor Division, Beam Instrumentation Department, is always adopting modern and current software methodologies for complex DAQ architectures. This paper highlights the Redis Adapter (RA) as the key software component enabling high performance, modular communication between digitizers and distributed control systems by leveraging Redis and containerization. The RA provides a unified, efficient interface between Redis based data streams and consumer systems. In the legacy architecture, digitized data flowed through the custom, UDP based Distributed Data Communication Protocol in the middle layer. In the current system, DDCP remains the ingestion path, while the RA serves as the decoupling layer. The proposed system replaces old VME digitizers with a SOM-based digitizer that communicates with Redis using the RA. The RA acts as both a performance-critical bridge and a protocol-agnostic adapter, ensuring compatibility with legacy control frameworks while enabling future scalability and modularity. This restructuring of the middle layer also helps the system achieve high throughput, reduce latency, and simplify the data path. Finally, we will demonstrate how RA is utilized in our two core products to deliver both legacy compatibility and future flexibility.

Joshi, S. [Fermilab]↗

Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument

Here, the design of a submersible, gamma-ray tomography system for imaging irradiated nuclear fuel is described. The system—named Fuel Interrogation and Examination using Submersible Tomography Analysis (FIESTA) Mk. II—is a variation on a previous Mk. I I design, which was developed to non-destructively image fuel capsules irradiated in the Advanced Test Reactor at the Idaho National Laboratory. The FIESTA system uses a combination of transmission computed tomography and emission computed tomography to image the restructuring and fission product migration at different points of burnup. Changes made to FIESTA Mk. I reflect the revised design requirements and a need to reduce background noise, largely originating from downscattered photons from fuel and transmission source. The computational design and radiation transport simulations are described.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Ultra-pure nickel for structural components of low-radioactivity instruments

The next generation of nuclear and particle physics rare-event search experiments demand structural materials combining ultra-low levels of radioactive contamination with exceptional mechanical strength. Here, this study evaluates chemical vapor deposition (CVD) nickel as a low radioactive background candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates was assayed via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution. These material assays produced measured bulk concentration of 232 Th, 238 U, and nat K at the levels of ~70 ppq, ≲100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 μ m beneath the surface, likely associated with the aluminum growth substrate. Additionally, the CVD Ni underwent tensile testing alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, heat treatment was found to reduce the tensile strength to levels comparable to standard Ni, with implications for high-temperature weld joining methods. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in surface cleaning and weld-joining techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

47 OTHER INSTRUMENTATION↗

Design of a first-of-A-kind instrumented advanced test reactor irradiation Capsule experiment for In situ thermal conductivity measurements of metallic fuel

Metallic fuel undergoes dramatic microstructural changes early in life due to fission gas swelling until ~2–3 at% burnup which affects the conductivity of the material, however the evolution of metallic fuel thermal conductivity during this early phase burnup has never been successfully measured in situ. The Irradiated Material Properties Accelerated Characterization Test (IMPACT) experiment will be the first in a series of experiments to irradiate advanced nuclear metallic fuel specimens with novel embedded thermal conductivity probes in ATR. In the current work the IMPACT experiment final design and supporting analysis is reported in detail. Results are evaluated for various reactor operational conditions to meet the functional requirements of the experiment. Finally, the first iteration of this IMPACT experiment will provide data regarding thermal properties evolution in uranium-zirconium (U10Zr) fuel, but this experiment vehicle is envisioned for future advanced fuels and structural materials irradiations in ATR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Reproducibility of Spin-Echo Small-Angle Neutron Scattering Instruments

Spin-echo small-angle neutron scattering (SESANS) is a unique method to measure structures of materials in real space with length scales from ∼ 30 μm to ∼20 µm. As shown in Figure 1, the accessible length scale of SESANS is given by its ability to encode the momentum transfer into the Larmor phase, namely Φ = $\vec{𝛿}$ ⋅ $\vec{𝑄}$, where $\vec{𝑄}$ is the momentum transfer and $\vec{𝛿}$ is the encoding vector of the setup and its projection along Q (δQ) is called spin-echo length (SEL). The spin echo length, which is synonymous with the spatial correlation distance probed, is defined as the following 𝛿𝑄 ∝ 𝜆 2 𝐵𝐿cot𝜃 where 𝜆 is neutron wavelength, B is magnetic field, L is length of the parallelogram magnetic field region, and 𝜃 is the angle between the inclined magnetic field boundary and the beam direction, as shown in Figure 1. The result of the SESANS experiment is a Hankel transformation of the SANS scattering function I(Q), which yields the correlation function of the sample in real space.

47 OTHER INSTRUMENTATION↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AmeriFlux Measurement Component Instrument Handbook

An AMC system was installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s North Slope Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling PAR sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape. The soil VWC and temperature sensors used at NSA C1 are the Campbell Scientific CS650L and the sensors at NSA M1 use the Campbell Scientific CS655. The two sensors are nearly identical in function, and vendor specifications are based on the CS650 unless otherwise stated.

47 OTHER INSTRUMENTATION↗

Ultrafine Condensation Particle Counter Instrument Handbook

The Model 3776 Ultrafine Condensation Particle Counter (UCPC; pictured in Appendix A) is designed for researchers interested in airborne particles smaller than 20 nm. With sensitivity to particles down to 2.5 nm in diameter, this UCPC is ideally suited for atmospheric and climate research, particle formation and growth studies, combustion and engine exhaust research, and nanotechnology research.

47 OTHER INSTRUMENTATION↗

Stereo Cameras for Clouds (STEREOCAM) Instrument Handbook

The three pairs of stereo camera setups aim to provide synchronized and stereo calibrated time series of images that can be used for 3D cloud mask reconstruction. Each camera pair is positioned at approximately 120 degrees from the other pair, with a 17o-19o pitch angle from the ground, and at 5-6 km distance from the U.S. Department of Energy (DOE) Central Facility at the Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) observatory to cover the region from northeast, northwest, and southern views. Images from both cameras of the same stereo setup can be paired together to obtain 3D reconstruction by triangulation. 3D reconstructions from the ring of three stereo pairs can be combined together to generate a 3D mask from surrounding views. This handbook delivers all stereo reconstruction parameters of the cameras necessary to make 3D reconstructions from the stereo camera images.

47 OTHER INSTRUMENTATION↗

Tethered Balloon System (TBS) Instrument Handbook

The Tethered Balloon System (TBS) is an unmanned aerial system composed of a helium-filled balloon, tether, winch, and sensors. Individual components of the system may change with each flight based on the desired measurements, atmospheric conditions, and flight strategy. The TBS operates within the U.S. Department of Energy (DOE)’s R-2204 Restricted Airspace, which encompasses a two-nautical-mile radius centered on Oliktok Point, Alaska that is segmented by altitude into R-2204 Low (0-1,499’ MSL or 0-457 m MSL) and R-2204 High (1,500-6,999’ MSL or 457-2133 m MSL). The TBS may operate outside of R-2204 if allowed to do so under a Certificate of Authorization from the Federal Aviation Administration.

42 ENGINEERING↗

FY26 Mid-Year Report Self-Diagnostic Capabilities for Neutron Instruments

This year we will transfer the latest version of INCC6 with last year’s self-diagnostic features to the IAEA. In FY25 we completed the development of three automated self diagnostic features into INNC6. The completion of these features marked the final stable version of INCC 6.0 ready for release to the IAEA and other users. In the first half of the Fiscal Year 2026 we have worked with LANL’s Feynman Center and Export Control office to attain a license for exporting INCC6 to the IAEA. We have successfully attained the export license for INCC6, and contacts at the IAEA have been granted permission to receive INCC6. We are in the final stage of writing the version 6 user manual. Once this is complete, we will deliver INCC6 to the IAEA for testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗