Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Interferometric direction finding with a metamaterial detector

We present measurements and analysis demonstrating useful direction finding of sources in the S band (2–4 GHz) using a metamaterial detector. An augmented metamaterial absorber that supports magnitude and phase measurement of the incident electric field, within each unit cell, is described. The metamaterial is implemented in a commercial printed circuit board process with off-board back-end electronics. We also discuss on-board back-end implementation strategies. Direction finding performance is analyzed for the fabricated metamaterial detector using simulated data and the standard algorithm, MUtiple SIgnal Classification. The performance of this complete system is characterized by its angular resolution as a function of radiation density at the detector. Sources with power outputs typical of mobile communication devices can be resolved at kilometer distances with sub-degree resolution and high frame rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complex photonic lattices embedded with tailored intrinsic defects by a dynamically reconfigurable single step interferometric approach

We report sculptured diverse photonic lattices simultaneously embedded with intrinsic defects of tunable type, number, shape as well as position by a single-step dynamically reconfigurable fabrication approach based on a programmable phase spatial light modulator-assisted interference lithography. The presented results on controlled formation of intrinsic defects in periodic as well as transversely quasicrystallographic lattices, irrespective and independent of their designed lattice geometry, portray the flexibility and versatility of the approach. The defect-formation in photonic lattices is also experimentally analyzed. Further, we also demonstrate the feasibility of fabrication of such defects-embedded photonic lattices in a photoresist, aiming concrete integrated photonic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interferometric and schlieren characterization of the plasmas and shock wave dynamics during laser-triggered discharge in atmospheric air

This paper describes our efforts to reveal the underlying physics of laser-triggered discharges in atmospheric air using a Mach-Zehnder interferometer and schlieren photography. Unlike the hemispherical shock waves that are produced by laser ablation, bell-like morphologies are observed during laser-triggered discharges. Phase shifts are recovered from the interferograms at a time of 1000 ns by the 2D fast Fourier transform method, and then the values of the refractive index are deduced using the Abel inversion. An abundance of free electrons is expected near the cathode surface. The schlieren photographs visualize the formation of stagnation layers at ∼600 ns in the interaction zones of the laser- and discharge-produced plasmas. Multiple reflected waves are observed at later times with the development of shock wave propagations. Estimations using the Taylor-Sedov self-similar solution indicated that approximately 45.8% and 51.9% of the laser and electrical energies are transferred into the gas flow motions, respectively. Finally, numerical simulations were performed, which successfully reproduced the main features of the experimental observations, and provided valuable insights into the plasma and shock wave dynamics during the laser-triggered discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature and non-linear response of cantilever-type mechanical oscillators used in atomic force microscopes with interferometric detection

The sensitivity of atomic force microscopes is fundamentally limited by the cantilever temperature, which can be, in principle, determined by measuring its thermal spectrum and applying the equipartition theorem. However, the mechanical response can be affected by the light field inside the cavity of a Fabry-Perot interferometer due to light absorption, radiation pressure, photothermal forces, and laser noise. By evaluating the optomechanical Hamiltonian, we are able to explain the peculiar distance dependence of the mechanical quality factor as well as the appearance of thermal spectra with symmetrical Lorentzian as well as asymmetrical Fano line shapes. Our results can be applied to any type of mechanical oscillator in an interferometer-based detection system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative measurements of electromechanical response with a combined optical beam and interferometric atomic force microscope

An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The OBD method is easy to implement, has impressive noise performance, and tends to be mechanically robust. However, it represents an indirect measurement of the cantilever displacement, since it is fundamentally an angular rather than a displacement measurement. Here, we demonstrate a metrological AFM that combines an OBD sensor with a laser Doppler vibrometer (LDV) to enable accurate measurements of the cantilever velocity and displacement. The OBD/LDV AFM allows a host of quantitative measurements to be performed, including in-situ measurements of cantilever oscillation modes in piezoresponse force microscopy. As an example application, we demonstrate how this instrument can be used for accurate quantification of piezoelectric sensitivity—a longstanding goal in the electromechanical community.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A step-wise steerable source of illumination for low-noise “Violin-Mode” shadow sensors, intended for use in interferometric gravitational wave detectors

A steerable low-noise source of illumination is described for shadow-sensors having a displacement sensitivity of ∼100 pm (rms)/√Hz, at 500 Hz, over a measuring span of at least ±0.5 mm. These sensors were designed to detect lateral “Violin-Mode” resonances in the highly tensioned fused-silica suspension fibres of the test-masses/mirrors for the Advanced Laser Interferometer Gravitational Wave Observatory gravitational wave detectors. The shadow sensors—one intended for each of the four fibres in a suspension—comprised a source of Near InfraRed (NIR) radiation (emitter) and a differential shadow-displacement sensor (detector), these bracketing the fibre under test. The suspension fibres themselves were approximately 600 mm long by 0.4 mm in diameter, and when illuminated from the side, they cast narrow, vertical, shadows onto their respective detectors—these being located at an effective distance of 50 fibre diameters behind the axes of the fibres themselves. The emitter described here was designed to compensate for a significant degree of mechanical drift or creep over time in the mean position of its suspension fibre. This was achieved by employing five adjacent columns of 8 × miniature NIR LEDs (Light Emitting Diodes, λ = 890 nm), with one column being activated at a time. When used in conjunction with a “reverse Galilean” telescope, the LED sources allowed the collimated beam from the emitter to be steered azimuthally in fine angular increments (0.65°), causing the fibre’s shadow to move laterally, in a step-wise manner, across the plane of its facing detector. Each step in shadow position was approximately 0.23 mm in size, and this allowed the fibre’s shadow to be re-centred, so as to bridge once again both elements of its photodiode detector—even if the fibre was off-centred by as much as ±0.5 mm. Re-centring allowed Violin-Mode vibrations of the fibre to be sensed once again as differential AC photocurrents, these flowing in anti-phase in the two elements of the “split-photodiode” detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time resolved interferometric study of the plasma plume induced shock wave in confined geometry: Two-dimensional mapping of the ambient and plasma density

An experimental investigation of the laser produced plasma induced shock wave in the presence of confining walls placed along the axial as well as the lateral direction has been performed. A time resolved Mach Zehnder interferometer is set up to track the primary as well as the reflected shock waves and its effect on the evolving plasma plume has been studied. An attempt has been made to discriminate the electronic and medium density contributions towards the changes in the refractive index of the medium. Two dimensional spatial distributions for both ambient medium density and plasma density (electron density) have been obtained by employing customised inversion technique and algorithm on the recorded interferograms. The observed density pattern of the surrounding medium in the presence of confining walls is correlated with the reflected shock wave propagation in the medium. Further, the shock wave plasma interaction and the subsequent changes in the shape and density of the plasma plume in confined geometry are briefly described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electro-optic modulation of a laser at microwave frequencies for interferometric purposes

A multi-point microwave interferometer (MPMI) concept was previously proposed by the authors for spatially-resolved, non-invasive tracking of a shock, reaction, or detonation front in energetic media [P. Specht et al., AIP Conf. Proc. 1793, 160010 (2017).]. The advantage of the MPMI concept over current microwave interferometry techniques is its detection of Doppler shifted microwave signals through electro-optic (EO) modulation of a laser. Since EO modulation preserves spatial variations in the Doppler shift, collecting the EO modulated laser light into a fiber array for recording with an optical heterodyne interferometer yields spatially-resolved velocity information. This work demonstrates the underlying physical principle of the MPMI diagnostic: the monitoring of a microwave signal with nanosecond temporal resolution using an optical heterodyne interferometer. For this purpose, the MPMI concept was simplified to a single-point construction using two tunable 1550 nm lasers and a 35.2 GHz microwave source. A (110) ZnTe crystal imparted the microwave frequency onto a laser, which was combined with a reference laser for determination of the microwave frequency in an optical heterodyne interferometer. A single, characteristic frequency associated with the microwave source was identified in all experiments, providing a means to monitor a microwave signal on nanosecond time scales. Lastly, areas for improving the frequency resolution of this technique are discussed, focusing on increasing the phase-modulated signal strength.

Specht, Paul E. (ORCID:000000027007000X)↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Nonlinear dispersive similariton: spectral interferometric study

A similariton formed in a passive optical fibre is experimentally found and investigated by spectral interferometry completely characterising the complex radiation field. A nonlinear dispersive character of similariton formation leads to chirp linearisation and spectrotemporal similarity of this similariton. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-sensitive interferometric control of the quality of diffractive elements

The prospects of the long lateral shear interferometry for controlling the quality of diffractive elements are shown. In this case, use is made of two diffractive elements, one of which is under investigation, and the other is the model one. A universal device is proposed to control the quality of the diffractive elements of both transmission and reflection types. We present the results of experimental realisation of the technique for the quality control of production of two-dimensional amplitude masks and reflection diffraction gratings. (interferometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometric imaging of nonlocal electromechanical power transduction in ferroelectric domains

Significance The conversion between electrical and acoustic signals in piezoelectric materials is of fundamental importance for their applications. Because of the much slower speed of sound than speed of light in solids, mesoscopic imaging is imperative for the study of electroacoustic behaviors at microwave frequencies. In this paper, the electromechanical power transduction in lithium niobate domains is spatially resolved by microwave impedance microscopy. Because of the sign reversal of piezoelectric tensor in opposite domains, the interaction between electric fields and elastic waves leads to fringe patterns that are fundamentally different from the acoustic displacement fields. This approach uncovers hidden information in the piezoelectric transduction process and opens a frontier to explore various elastic phenomena in materials and devices.

42 ENGINEERING↗

Interferometric measurements of graphene-based membranes for micromechanical applications

Recent studies on piezoelectricity in 2D materials, such as graphene, have revealed their potential in multiple applications including microelectromechanical systems. Herein, we reveal piezoelectricity in few-layer graphene sheets deposited on amorphous Si 3 N 4 membranes. The response in the center of square membrane of 6.7 × 6.7 mm 2 size reaches about 14 nm at resonance and could be further enhanced by adjusting the composite structure. Resonance piezoelectric phenomena are fully consistent with the earlier piezoresponse force microscopy observations on free-standing piezoelectric graphene and open up a possibility of using 2D materials in micromechanical applications.

36 MATERIALS SCIENCE↗

MILLIMETER AND SUBMILLIMETER HIGH ANGULAR RESOLUTION INTERFEROMETRIC OBSERVATIONS: DUST IN THE HEART OF IRAS 18162-2048

The GGD27 complex includes the HH 80-81-80N system, which is one of the most powerful molecular outflows associated with a high-mass star-forming region observed to date. This outflow is powered by the star associated with the source IRAS 18162-2048. Here, we report on the detection of continuum emission at subarcsec/arcsec resolution with the Submillimeter Array (SMA) at 1.36 mm and 456 {mu}m, respectively. We detected dust emission arising from two compact cores, MM1 and MM2, separated by about 7'' ({approx}12,000 AU in projected distance). MM1 spatially coincides with the powerful thermal radio continuum jet that powers the very extended molecular outflow, while MM2 is associated with the protostar that drives the compact molecular outflow recently found in this region. High angular resolution observations at 1.36 mm show that MM1 is unresolved and that MM2 splits into two subcomponents separated by {approx}1''. The mass of MM1 is about 4 M{sub sun} and it has a size of {approx}<300 AU. This is consistent with MM1 being associated with a massive and dense (n(H{sub 2}) {approx}> 10{sup 9} cm{sup -3}) circumstellar dusty disk surrounding a high-mass protostar, which has not yet developed a compact H II region. On the other hand, the masses of the two separate components of MM2 are about 2 M{sub sun} each. One of these components is a compact core with an intermediate-mass young protostar inside and the other component is probably a prestellar core. MM1 is the brightest source at 1.36 mm, while MM2 dominates the emission at 456 {mu}m. These are the only (sub)millimeter sources detected in the SMA observations. Hence, it seems that both sources may contribute significantly to the bolometric luminosity of the region. Finally, we argue that the characteristics of these two sources indicate that MM2 is probably in an earlier evolutionary stage than MM1.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FIRST VERY LONG BASELINE INTERFEROMETRIC SETI EXPERIMENT

The first Search for Extra-Terrestrial Intelligence (SETI) conducted with very long baseline interferometry (VLBI) is presented. By consideration of the basic principles of interferometry, we show that VLBI is efficient at discriminating between SETI signals and human generated radio frequency interference (RFI). The target for this study was the star Gliese 581, thought to have two planets within its habitable zone. On 2007 June 19, Gliese 581 was observed for 8 hr at 1230-1544 MHz with the Australian Long Baseline Array. The data set was searched for signals appearing on all interferometer baselines above five times the noise limit. A total of 222 potential SETI signals were detected and by using automated data analysis techniques were ruled out as originating from the Gliese 581 system. From our results we place an upper limit of 7 MW Hz{sup -1} on the power output of any isotropic emitter located in the Gliese 581 system within this frequency range. This study shows that VLBI is ideal for targeted SETI including follow-up observations. The techniques presented are equally applicable to next-generation interferometers, such as the long baselines of the Square Kilometre Array.

79 ASTRONOMY AND ASTROPHYSICS↗

ENHANCED INTERFEROMETRIC IDENTIFICATION OF SPECTRA IN HABITABLE EXTRASOLAR PLANETS

An Earth-like extrasolar planet emits light that is many orders of magnitude fainter than that of the parent star. We propose a method of identifying bio-signature spectral lines in light of known extrasolar planets based on Fourier spectroscopy in the infrared, using an off-center part of a Fourier interferogram only. This results in superior sensitivity to narrower molecular-type spectral bands, which are expected in the planet spectrum but are absent in the parent star. We support this idea by numerical simulations that include photon and thermal noise, and show it to be feasible at a luminosity ratio of 10{sup -6} for a Sun-like parent star in the infrared. We also carried out a laboratory experiment to illustrate the method. The results suggest that this method should be applicable to real planet searches.

79 ASTRONOMY AND ASTROPHYSICS↗

INTERFEROMETRIC UPPER LIMITS ON MILLIMETER POLARIZATION OF THE DISKS AROUND DG Tau, GM Aur, AND MWC 480

Millimeter-wavelength polarization measurements offer a promising method for probing the geometry of magnetic fields in circumstellar disks. Single dish observations and theoretical work have hinted that magnetic field geometries might be predominantly toroidal, and that disks should exhibit millimeter polarization fractions of 2%-3%. While subsequent work has not confirmed these high polarization fractions, either the wavelength of observation or the target sources differed from the original observations. Here we present new polarimetric observations of three nearby circumstellar disks at 2'' resolution with the Submillimeter Array and the Combined Array for Research in Millimeter Astronomy. We reobserve GM Aur and DG Tau, the systems in which millimeter polarization detections have been claimed. Despite higher resolution and sensitivity at wavelengths similar to the previous observations, the new observations do not show significant polarization. We also add observations of a new HAeBe system, MWC 480. These observations demonstrate that a very low ({approx}<0.5%) polarization fraction is probably common at large ({approx}>100 AU) scales in bright circumstellar disks. We suggest that high-resolution observations may be worthwhile to probe magnetic field structure on linear distances smaller than the disk scale height, as well as in regions closer to the star that may have larger MRI-induced magnetic field strengths.

79 ASTRONOMY AND ASTROPHYSICS↗