Search NASA⌕ Search

SEARCH · Search NASA

Results for “interior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Guia de Edificios Saludables para Pequenas Empresas: Una Referencia Rapida para Mejorar la Calidad del Aire Interior (Restaurantes Excluidos)

Indoor air pollutant concentrations can be higher than those outdoors, putting occupants at risk. These pollutants come from a variety of sources: materials used to build and furnish indoor spaces, retail products and services, and occupants themselves. Ventilation, temperature, and humidity also affect indoor air quality. It is important to consider the documented benefits of healthy indoor environments at any time - not just during a public health crisis - and it is key to consider the indoor air quality where we do business as well as at home. Small businesses vary in size, services, products, ownership style, and building mechanical systems, yet all benefit from healthy indoor spaces for employees and customers. This guide provides steps, in conjunction with public health guidance, that small businesses can take to improve and maintain indoor air quality. Small businesses often have unique ownership structures - the building owner and business owner can be different parties - so this guide addresses both building and business owner action items. There are many ways to pursue healthy indoor air, including eliminating, minimizing, and/or controlling the contaminants we bring in, and removing or diluting any existing contaminants through ventilation, filtration, air cleaning, and/or disinfection. Best results are achieved through a comprehensive approach combining various strategies, including those discussed in this guide.

air filtration↗

Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant

Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.

01 COAL, LIGNITE, AND PEAT↗

Spitzer Phase-curve Observations and Circulation Models of the Inflated Ultrahot Jupiter WASP-76b

The large radii of many hot Jupiters can only be matched by models that have hot interior adiabats, and recent theoretical work has shown that the interior evolution of hot Jupiters has a significant impact on their atmospheric structure. Due to its inflated radius, low gravity, and ultrahot equilibrium temperature, WASP-76b is an ideal case study for the impact of internal evolution on observable properties. Hot interiors should most strongly affect the nonirradiated side of the planet, and thus full phase-curve observations are critical to ascertain the effect of the interior on the atmospheres of hot Jupiters. In this work, we present the first Spitzer phase-curve observations of WASP-76b. We find that WASP-76b has an ultrahot dayside and relatively cold nightside with brightness temperatures of 2471 ± 27 K/1518 ± 61 K at 3.6 μm and 2699 ± 32 K/1259 ± 44 K at 4.5 μm, respectively. These results provide evidence for a dayside thermal inversion. Both channels exhibit small phase offsets of 0.68 ± 0.°48 at 3.6 μm and 0.67 ± 0.°2 at 4.5 μm. We compare our observations to a suite of general circulation models (GCMs) that consider two endmembers of interior temperature along with a broad range of frictional drag strengths. Strong frictional drag is necessary to match the small phase offsets and cold nightside temperatures observed. From our suite of cloud-free GCMs, we find that only cases with a cold interior can reproduce the cold nightsides and large phase-curve amplitude at 4.5 μm, hinting that the hot interior adiabat of WASP-76b does not significantly impact its atmospheric dynamics or that clouds blanket its nightside.

79 ASTRONOMY AND ASTROPHYSICS↗

A Perturbative Solution for Nonlinear Stratified Upwelling over a Frictional Slope

Abstract A perturbative solution of simplified primitive equations for nonlinear weakly stratified upwelling over a frictional slope is found that resolves the vertical structure of velocity fields and can satisfy Ertel’s potential vorticity conservation in the stratified inviscid interior. The solution uses assumptions consistent with the model proposed by Lentz and Chapman, including a steady-state, constant cross-shore density gradient, no alongshore gradients, laterally inviscid, and consideration of cross-shore advection of alongshore momentum. The solution resolves the vertical structure of velocity fields (including subsurface maxima of compensational flow, not resolved by Lentz and Chapman) and can satisfy Ertel’s potential vorticity conservation in the stratified inviscid interior. The dynamics are similar to Lentz and Chapman; bottom stress balances alongshore wind stress in a homogeneous density ocean and is replaced by nonlinear cross-shore transport of alongshore momentum as the Burger number (S=αN/f, whereα,N, andfare the bottom slope, buoyancy frequency, Coriolis frequency, respectively) increases. When the solution uses the empirical relation between cross-shore and vertical density gradients proposed by Lentz and Chapman, vorticity conservation is not satisfied and the nonlinear momentum transport estimated by the solution linearly increases withS, asymptotically matching Lentz and Chapman forS< 1. When the solution conserves interior potential vorticity, the momentum transport is proportional toS 2 forS< 1 and is in better agreement with numerical simulations.

Oceanography↗

Shrouded screw device for removing and depositing material

A shrouded screw apparatus includes an outer tube, a telescoping inner tube, an auger bit, and an anti-rotation pin. The outer tube has a first sidewall defining a first interior chamber. The first sidewall has an opening defined therethrough. The inner tube is positioned in the first interior chamber. The inner tube has a second sidewall defining a second interior chamber. The second sidewall has a longitudinal groove defined therein. The inner tube is configured to extend from and retract within the first interior chamber of the outer tube. The auger bit is positioned in the second interior chamber and is rotatably coupled to the inner tube. The anti-rotation pin is coupled to the first sidewall of the outer tube and extends inwardly into the first interior chamber. The pin engages the longitudinal groove of the inner tube.

47 OTHER INSTRUMENTATION↗

Shrouded screw device for removing and depositing material

A shrouded screw apparatus includes an outer tube, a telescoping inner tube, an auger bit, and an anti-rotation pin. The outer tube has a first sidewall defining a first interior chamber. The first sidewall has an opening defined therethrough. The inner tube is positioned in the first interior chamber. The inner tube has a second sidewall defining a second interior chamber. The second sidewall has a longitudinal groove defined therein. The inner tube is configured to extend from and retract within the first interior chamber of the outer tube. The auger bit is positioned in the second interior chamber and is rotatably coupled to the inner tube. The anti-rotation pin is coupled to the first sidewall of the outer tube and extends inwardly into the first interior chamber. The pin engages the longitudinal groove of the inner tube.

Kontras, Evan A.↗

Shifts in belowground processes along a temperate forest edge

Abstract Context Forests are increasingly fragmented, and as a result most forests in the United States are within one km of an edge. Edges change environmental conditions of the forest—especially radiation, roughness, temperature, and moisture—that can have consequences for plant productivity and ecosystem functions. However, edge effects on aboveground characteristics of plants and the environment are better understood relative to plant roots and soil in the belowground environment. Objectives Our main objectives were to determine if soil C pools and fluxes are higher at the edge relative to other landscape positions, and to understand how specific belowground processes contribute to bulk differences in pools and fluxes. Methods We measured environmental conditions, live and dead fine root traits, soil chemistry, and soil respiration along a 75 m transect from interior forest to meadow in Gaithersburg, MD. Results We observed differences in the soil chemical, biological and hydrological environment between the forest interior, edge and adjacent meadow. In some cases, the forest edge represented a mid-point in environmental or belowground characteristics between the forest interior and meadow ( e.g. , pH, C-to-N ratio [C:N], live fine root biomass, heterotrophic respiration), likely reflecting the change in litter type and quality associated with the transition from grass to woody species. In other cases, neighboring landscape positions were different from the forest edge, which was drier and had higher dead fine root biomass. Although soil C contents were not significantly different across landscape positions, there was a tendency towards higher average soil C content at the edge relative to other landscape positions, suggesting that increased C loss related to root decay and greater soil respiration at the edge relative to the forest interior may have been offset by increased C gain from high plant productivity and subsequent inputs to soil. Conclusions This research provides insight into how forest edge environments may differ from the interior and how concurrent processes above- and belowground may contribute to those differences.

54 ENVIRONMENTAL SCIENCES↗

Quartz-hosted inclusions and embayments reveal storage, fluxing, and ascent of the Mesa Falls Tuff, Yellowstone

Quartz-hosted glasses from the Mesa Falls Tuff provide a geochemical window into the pre-eruptive magmatic system from one of Yellowstone's largest-volume caldera-forming eruptions. H 2 O and CO 2 concentrations, along with major and trace elements, were measured in both fully enclosed glass inclusions and partially enclosed embayments in the same quartz crystals. Major elements are largely consistent between the inclusions and embayments, except for K 2 O and Na 2 O. Of note, K 2 O is enriched by ~1 wt.% in embayment interiors relative to inclusions. Most trace elements are also enriched in the embayment interiors compared to inclusions from the same crystals. Fractionation trends of trace elements are consistent with ~30-60% crystallization. Quartz-hosted glass inclusions preserve 3.1±0.9 wt.% H 2 O and 493±227 ppm CO 2 whereas embayment interiors have 0.9±0.1 wt.% H 2 O and 399±229 ppm CO 2 . The CO 2 is roughly similar, but the distinct ~2 wt.% discrepancy between inclusion and embayment interior H 2 O contents may have been produced by CO 2 fluxing sourced from underplated Yellowstone basalts. H 2 O gradients within embayments are flat in their interiors and modified by sharp positive gradients near embayment exteriors which were produced by post-eruptive rehydration. CO 2 gradients occur as gently sloping concentration gradients that extend inward 150 to 250 μm from the embayment exterior. Finally, finite-difference 1D and 2D diffusion modeling indicates the distribution of H 2 O and CO 2 in embayments was produced by slow, fluid-saturated decompression that preceded rapid ascent during the caldera-forming eruption.

2D diffusion modeling↗

Diverter fittings for cooling systems of an engine

A passive diverter fitting for a cooling system of an engine includes a base defining an interior cavity, an inlet opening extending through the base that is in fluid communication with the interior cavity, an outlet opening that is in fluid communication with the interior cavity, and a bypass opening that is in fluid communication with the interior cavity. The base is configured to be removably disposed in a cavity of an engine block. The inlet opening is positioned to receive coolant when the passive diverter fitting is disposed in the cavity of the engine block. The outlet opening is in fluid communication with the area exterior to the engine block when the passive diverter fitting is disposed in the cavity of the engine block. The bypass opening is in fluid communication with an interior coolant passage of the engine block when the passive diverter fitting is disposed in the cavity of the engine block.

Chen, Allen Yao↗

A Three–Dimensional Nanoscale View of Electrocatalyst Degradation in Hydrogen Fuel Cells

The loss of platinum (Pt) electrochemically active surface area (ECSA) is a critical degradation mode that often becomes a limiting factor for heavy-duty proton exchange membrane fuel cell vehicles. High surface area carbon supports have been shown to improve Pt dispersion and limit detrimental ionomer-electrocatalyst interactions due to their large interior pore volume. Here, in this work, using automated scanning transmission electron tomography, the degradation of nanoparticles located on the interior versus exterior surfaces of the carbon support is compared following a catalyst-specific accelerated stress test (AST) of 90,000 voltage cycles between 0.6 V to 0.95 V. The results reveal a notable increase in median particle size for both interior and exterior Pt catalyst particles, with a slightly higher increase in particle size distribution and loss of specific surface area for the particles located on the exterior carbon surface. The fraction of Pt nanoparticles that reside within the interior of the carbon support also increased following the AST test, accompanied by evidence of an increase in average carbon mesopore size. Here, the results shed light on the degradation mechanisms affecting electrochemical properties and the enhanced particle accessibility at lower relative humidity.

08 HYDROGEN↗