Modeling a Grid-Forming Inverter Dynamics Under Ground Fault Scenarios Using Experimental Data From Commercially Available Equipment.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
In this work, we provide an in-depth structural characterization of the amorphous ionic glasses LiPON and LiSiPON with high Li content. Based on ab initio molecular dynamics simulations, the structure of these materials is an inverted structure with either isolated polyanion tetrahedra or polyanion dimers in a Li+ matrix. Based on neutron scattering data, this type of inverted structure leads to a significant amount of medium-range ordering in the structure, as demonstrated by two sharp diffraction peaks and a periodic structural oscillation in the density function G(r). While this medium-range ordering is commonly observed in liquids and metallic glasses, it has not previously been observed in oxides. On a local scale, adding N and Si increases the number of anion bridges and polyanion dimer structures, leading to higher ionic conductivity. In the medium-range ordering, the addition of Si leads to more disorder in the polyanion substructure but a significant increase in the ordering of the O substructure. Finally, we demonstrate that this inverted structure with medium-range ordering results in a glassy material that is both mechanically stiff and ductile on the nanoscale.
We invert far field infrasound data for the equivalent seismo-acoustic time domain moment tensor to assess the relative importance of two assumed seismoacoustic source mechanisms. The infrasound data were produced by a four of the underground chemical explosions that were conducted during the Source Physics Experiment (SPE). For each SPE event that we invert, we produce three set of atmospheric Green's functions: an average model based on ten years of atmospheric data, as well as two extrema models designed to maximize the variability of atmospheric conditions for the given time-of-day and day-of-year for each SPE event. To parameterize the inversion, we assume that the source of infrasonic energy results from the linear combination of explosion-induced surface spall and linear seismic-to-elastic mode conversion at the Earth's free surface. We find that the inversion yields relatively repeatable results for the estimated spall source whereas the estimated isotropic explosion source is highly variable. This suggests that the majority of the observed acoustic energy is produced by the spall source and/or our modeling of the elastic energy propagation, and data are subsequent conversion to acoustic energy via linear elastic-to-acoustic coupling at the surface, is too simplistic.
The software was developed to invert seismic amplitude-versus-angle (AVA) data using a Bayesian framework. The posterior probability distribution function is sampled by effective Markov chain Monte Carlo (MCMC) methods. The software could provide not only estimates of unknown variables but also varieties of information about uncertainty, such as the mean, mode, median, variance, and even probability density of each unknown.
Weather-induced spatio-temporal degradation limits outdoor PV inverter lifetime and reliability, necessitating advanced data analysis. This study employs a top-down, data-driven approach utilizing multiple machine learning (ML) algorithms to estimate inverter reliability in a 1.4 MW PV power plant, considering factors such as irradiance, humidity, temperature, time of day, and weather conditions. An extensive alert dataset from 17 identical inverters, including alert types, propagation, and frequency, reveals significant correlations with environmental factors and inverter output power, enabling the construction of a performance reliability model. Dual-stage supervised-ML models are evaluated for accuracy, with the ‘classification-regression’ model by an artificial neural network (ANN) tested on the averaged “Alert-Ambient” dataset, which is outperformed by ‘clustering-regression’ models using random forest (RF) and K-Nearest Neighbors (KNN) on individual inverter datasets. K-means clustering applies principal component analysis to reduce dimensions, achieving improved accuracy beyond the 80% achieved by ANN on the averaged dataset. Second-stage regression estimates inverter reliability with a mean square error of 0.0195 on the averaged dataset and as low as 0.002 on individual inverter datasets using RF. Furthermore, these findings highlight the method's suitability for estimating PV inverter output reliability under ambient conditions, essential for digital twin development and related applications.
As carbon dioxide (CO{sub 2}) is sequestered from the bottom of a brine reservoir and allowed to migrate upward, the effects of the relative permeability hysteresis due to capillary trapping and buoyancy driven migration tend to make the reservoir patchy saturated with different fluid phases over time. Seismically, such a patchy saturated reservoir induces an effective anisotropic behavior whose properties are primarily dictated by the nature of the saturation of different fluid phases in the pores and the elastic properties of the rock matrix. By combining reservoir flow simulation and modeling with seismic modeling, it is possible to derive these effective anisotropic properties, which, in turn, could be related to the saturation of CO{sub 2} within the reservoir volume any time during the post-injection scenario. Therefore, if time-lapse seismic data are available and could be inverted for the effective anisotropic properties of the reservoir, they, in combination with reservoir simulation could potentially predict the CO{sub 2} saturation directly from the time-lapse seismic data. It is therefore concluded that the time-lapse seismic data could be used to monitor the carbon sequestrated saline reservoirs. But for its successful implementation, seismic modeling and inversion methods must be integrated with the reservoir simulations. In addition, because CO{sub 2} sequestration induces an effective anisotropy in the sequestered reservoir and anisotropy is best detected using multicomponent seismic data compared to single component (P-wave) data, acquisition, processing, and analysis is multicomponent seismic data is recommended for these time-lapse studies. Finally, a successful implementation of using time-lapse seismic data for monitoring the carbon sequestrated saline reservoirs will require development of a robust methodology for inverting multicomponent seismic data for subsurface anisotropic properties.
Here, this article introduces ways to identify dynamic system models using measurement data. In power system analysis, a static model represents the time-invariant input-output relationship of a system, while a dynamic model describes the behavior of the system over time. For example, how will a system transit from one steady-state operation point to another?
Rate constants for bimolecular electron transfer (ET) increased with driving force, -ΔG°, reached a plateau, and then decreased in an inverted region. This rate data was described well by electron transfer theory subject to a diffusion-controlled limit. These were for ET from radical anions of polydecylthiophene (P3DT) to a series of acceptors in THF solution. When the donor was the smaller anion of quaterthiophene (T4 •- ) the inverted region was much less prominent, and still less so for when the donor was the anion of bithiophene (T2 •- ). Description of the data using ET theory identifies smaller electronic couplings for the highly-delocalized P3DT anions as enabling the inverted behavior: The presence of a Marcus inverted region is a consequence of delocalized electronic states. The results of this study further imply that electronic couplings smaller than usually found for molecules in contact could boost efficiency of energy storage by electron transfer, and identifies size-mismatch as an important concept in control of electronic couplings.
The problem of inverting for multiple physical parameters in the subsurface using seismic full-waveform inversion (FWI) is complicated by interparameter trade-off arising from inherent ambiguities between different physical parameters. Parameter resolution is often characterized using scattering radiation patterns, but these neglect some important aspects of interparameter trade-off. More general analysis and mitigation of interparameter trade-off in isotropic-elastic FWI is possible through judiciously chosen multiparameter Hessian matrix-vector products. We show that products of multiparameter Hessian off-diagonal blocks with model perturbation vectors, referred to as interparameter contamination kernels , are central to the approach. We then apply the multiparameter Hessian to various vectors designed to provide information regarding the strengths and characteristics of interparameter contamination, both locally and within the whole volume. With numerical experiments, we observe that S-wave velocity perturbations introduce strong contaminations into density and phase-reversed contaminations into P-wave velocity, but themselves experience only limited contaminations from other parameters. Based on these findings, we introduce a novel strategy to mitigate the influence of interparameter trade-off with approximate contamination kernels. Furthermore, we recommend that the local spatial and interparameter trade-off of the inverted models be quantified using extended multiparameter point spread functions (EMPSFs) obtained with pre-conditioned conjugate-gradient algorithm. Compared to traditional point spread functions, the EMPSFs appear to provide more accurate measurements for resolution analysis, by de-blurring the estimations, scaling magnitudes and mitigating interparameter contamination. Approximate eigenvalue volumes constructed with stochastic probing approach are proposed to evaluate the resolution of the inverted models within the whole model. With a synthetic Marmousi model example and a land seismic field data set from Hussar, Alberta, Canada, we confirm that the new inversion strategy suppresses the interparameter contamination effectively and provides more reliable density estimations in isotropic-elastic FWI as compared to standard simultaneous inversion approach.
This paper presents a systematic approach to characterize the stability of a power-hardware-in-the-loop (PHIL) platform, an important step in PHIL tests. Many existing works focus the stability assessments on the PHIL interface algorithm; however, this work considers all software and hardware subsystems that form the closed loop of the PHIL experiment and develops a complete closed-loop stability assessment. This assessment is developed in the context of a common framework that can be readily applied to other PHIL platforms. This paper presents methods for characterizing key PHIL subsystems toward obtaining transfer functions to be used for analysis. The systematic stability assessment approach is demonstrated for a case study involving PHIL testing of a solar inverter and validated using experimental data. assessment. This assessment is developed in the context of a common framework that can be readily applied to other PHIL platforms. This paper presents methods for characterizing key PHIL subsystems toward obtaining transfer functions to be used for analysis. The systematic stability assessment approach is demonstrated for a case study involving PHIL testing of a solar inverter and validated using experimental data.
The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.
This dataset contains Electromagnetic Induction (EMI) data collected at Trail Creek, Colorado, in 2024. EMI surveys were conducted to investigate the spatial distribution of electrical conductivity in the subsurface, providing insights into soil moisture and subsurface geological features. The surveys were performed along multiple transects to capture variations in conductivity influenced by changes in soil composition, moisture content, and underlying geological structures. This dataset complements other geophysical data collected in the region, including Electrical Resistivity Tomography (ERT) and Terrestrial LiDAR Scanning (TLS), providing a detailed understanding of the subsurface and its impact on surface vegetation and hydrological processes. The data are valuable for environmental geophysics, ecological research, and hydrological modeling in mountainous ecosystems. The files include: - data.zip: the raw EMI data (.csv) - inversion.zip: the inverted resistivity model (.csv and .kml) - kriging.zip: the kriging resistivity model (.csv, .tif, .kmz) - flmd.csv: file level metadata file describing all files within this dataset - dd.csv: data dictionary file describing the column headers within CSV files This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.
A new coherence imaging Doppler spectroscopy diagnostic has been deployed on the UK’s Mega Amp Spherical Tokamak for scrape-off-layer and divertor impurity flow measurements. The system has successfully obtained 2D images of C III, C II, and He II line-of-sight flows, in both the lower divertor and main scrape-off-layer. Flow imaging has been obtained at frame rates up to 1 kHz, with flow resolution of around 1 km/s and spatial resolution better than 1 cm, over a 40° field of view. C III data have been tomographically inverted to obtain poloidal profiles of the parallel impurity flow in the divertor under various conditions. In this paper we present the details of the instrument design, operation, calibration, and data analysis as well as a selection of flow imaging results which demonstrate the diagnostic's capabilities.
We explore the use of centroid coordinates as a means to identify the 'locations' of electron-proton bremsstrahlung hard X-ray sources in solar flares. Differences between the coordinates of the electron and photon centroids are derived and explained. For electron propagation in a collision-dominated target, with either a uniform or an exponential density profile, the position of the electron centroid can be calculated analytically. We compare these analytic forms to data from a flare event on 2002 February 20. We first spectrally invert the native photon visibility data to obtain 'electron visibilities', which are in turn used to construct electron flux images at various electron energies E. Centroids of these maps are then obtained by straightforward numerical integration over the electron maps. This comparison allows us to infer the density structure in the two compact sources visible, and we discuss the (somewhat unexpected) results thus obtained.
As part of DEEPEN (DE-risking Exploration of geothermal Plays in magmatic ENvironments), a 3D play fairway analysis (PFA) was conducted at Newberry Volcano in Central Oregon for multiple play types (conventional hydrothermal, superhot EGS, and supercritical). For use in this PFA, combined full tensor broadband magnetotelluric (MT) and gravity data were acquired, processed, and inverted by Enthalpion Energy LLC (Enthalpion) with support from NREL staff. The data collection efforts took place from June 19th to July 24. Data were collected with the goal of gaining an improved understanding of the South Flank and the extent of the magma chamber. This GDR submission includes the raw data, single inversions, joint inversions, resolution matrices, and a report on these processes. More detailed information about the folder structure of the datasets included in this submission may be found on pages 94-97 of Magnetotelluric and Gravity Survey Report.pdf below.
The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.
Abstract A major challenge in the inversion of subsurface parameters is the ill‐posedness issue caused by the inherent subsurface complexities and the generally spatially sparse data. Appropriate simplifications of inversion models are thus necessary to make the inversion process tractable and meanwhile preserve the predictive ability of the inversion results. In this study, we investigate the effect of model complexity on fracture aperture inversion and thermal performance prediction in a field‐scale EGS model. Principal component analysis was used to map the aperture field to a low‐dimensional latent space. The complexity of the inversion model was quantitatively represented by the percentage of total variance in the original aperture fields preserved by the latent space. Tracer, pressure and flow rate data were used to invert for fracture aperture through an ensemble‐based inversion method, and the inferred aperture field was used to predict thermal performance. With an over‐simplified aperture model, ensemble collapse occurred. The inverted aperture models failed to resolve necessary flow and transport features, leading to a biased thermal performance prediction. A complex aperture model involved excessive features and was prone to overinterpreting the inversion data. Both the tracer/pressure/flow rate data reproduction and thermal prediction showed significant uncertainties, making it difficult to properly estimate long‐term thermal performance. Fortunately, our results indicate that there exists an appropriate model complexity which can simultaneously match inversion data and predict thermal performance with an acceptable uncertainty. The quality of the fit of tracer data appears to be a useful indicator of such an appropriate model complexity.
Resolving the time dependent terms in the seismic moment tensor provides important information that can be used to interpret the source process of an explosion, including the separation of isotropic explosion terms from shear forces and potentially isolated force couples. In this report, we detail our method of inverting three component seismic data for the seismic moment tensor. We review possible seismic source models from the simplest isotropic explosion type source to those incorporating the six independent moment tensor terms. The inversion we describe is formulated in the frequency domain, and results in estimates of time dependent moment tensor components. The inversion relies on an accurate estimate of the Green's functions of the Earth. However, given the complexity of the Earth, we explore the effects of inaccuracies in the presumed Earth model used to estimate the Green's functions needed for the inversion. Specifically, we explore the effects of stochastic variations in the Earth models on the inversion results. These tests are synthetic throughout, and show that adding stochastic density/velocity heterogeneity in the presumed Earth model results in reduced amplitude seismic moment tensor estimates, as well as degrading the data misfit. We suggest two mitigation strategies. First, produce a suite of Green's functions using different realizations of the stochastic field within the Earth Model. Secondly, perform the in- version in the power spectral domain, eliminating all phase information. Finally, we analyze actual seismic data collected in winter 2017/2018. The seismic data was collected at in active geothermal well site outside of Winnimucca, NV, and was produced during well stimulation operations. In general, the inversion results were poor, with a high degree of data misfit. We hypothesize that the poor results are a function of a poorly constrained Earth model as well as noisy, high-frequency data being used in the inversion.