Search NASA⌕ Search

SEARCH · Search NASA

Results for “islanding operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

NANT Site - ASSIST / Thermodynamic retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Rochette et al. 2009) operated by NOAA Physical Sciences Laboratory on Nantucket Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the ASSIST housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

A Data-Driven Democratized Control Architecture for Regional Transmission Operators

As probably the most complicated and critical infrastructure system, U.S. power grids become increasingly vulnerable to extreme events such as cyber-attacks and severe weather, as well as higher DER penetrations and growing information mismatch among system operators, utilities (transmission or generation owners), and end-users. This paper proposes a data-driven democratized control architecture considering two democratization pathways to assist transmission system operators, with a targeted use case of developing online proactive islanding strategies. Detailed discussions on load capability profiling at transmission buses and disaggregation of DER generations are provided and illustrated with real-world utility data. By Combining network and operational constraints, transmission system operators can be equipped with new tools built on top of this architecture, to derive accurate, proactive, and strategic islanding decisions to incorporate the wide range of dynamic portfolios and needs when facing extreme events or unseen grid contingencies.

Power System Reliability, Islanding, Democratized ↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗

Analytic and numerical bootstrap of CFTs with $O(m)\times O(n)$ global symmetry in 3D

Motivated by applications to critical phenomena and open theoretical questions, we study conformal field theories with O(m)\times O(n) O ( m ) × O ( n ) global symmetry in d=3 d = 3 spacetime dimensions. We use both analytic and numerical bootstrap techniques. Using the analytic bootstrap, we calculate anomalous dimensions and OPE coefficients as power series in \varepsilon=4-d ε = 4 − d and in 1/n 1 / n , with a method that generalizes to arbitrary global symmetry. Whenever comparison is possible, our results agree with earlier results obtained with diagrammatic methods in the literature. Using the numerical bootstrap, we obtain a wide variety of operator dimension bounds, and we find several islands (isolated allowed regions) in parameter space for O(2)\times O(n) O ( 2 ) × O ( n ) theories for various values of n n . Some of these islands can be attributed to fixed points predicted by perturbative methods like the \varepsilon ε and large- n n expansions, while others appear to arise due to fixed points that have been claimed to exist in resummations of perturbative beta functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

BLOC Site - ASSIST Thermodynamic retrievals TROPoe / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Rochette et al. 2009) operated by NOAA Physical Sciences Laboratory on Block Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Radiances are noise-filtered but not averaged in time to minimize errors due to non-uniform clouds. Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a sensor attached to the ASSIST housing. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY.

17 WIND ENERGY↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement report: Cloud condensation nuclei activity and its variation with organic oxidation level and volatility observed during an aerosol life cycle intensive operational period (ALC-IOP)

Abstract. Cloud condensation nuclei (CCN) spectrum and the CCN activated fraction of size-resolved aerosols (SR-CCN) were measured at a rural site on Long Island during the Department of Energy (DOE) aerosol life cycle intensive operational period (ALC-IOP) from 15 July to 15 August 2011. During the last week of the ALC-IOP, the dependence of the activated fraction on aerosol volatility was characterized by sampling downstream of a thermodenuder (TD) operated at temperatures up to 100 ∘C. Here we present aerosol properties, including aerosol total number concentration, CCN spectrum, and the CCN hygroscopicity, for air masses of representative origins during the ALC-IOP. The hygroscopicity of organic species in the aerosol is derived from CCN hygroscopicity and chemical composition. The dependence of organic hygroscopicity on the organic oxidation level (e.g., atomic O:C ratio) agrees well with theoretical predictions and results from previous laboratory and field studies. The derived κorg and O:C ratio first increase as TD temperature increases from 20 ∘C (i.e., ambient temperature) to 50 or 75 ∘C and then decrease as TD temperature further increases to 100 ∘C. The initial increases of O:C and κorg with TD temperature below 50 ∘C are likely due to evaporation of more volatile organics with relatively lower O:C and hygroscopicity such as primary organic aerosol. At the high TD temperatures, the decreases of O:C and κorg indicate that evaporated organics were more oxygenated and had lower molecular weights. These trends are different from previous laboratory experiments and field observations, which reported that organic O:C increased monotonically with increasing TD temperature, whereas κorg decreased with the TD temperature. One possible reason is that previous studies were either focused on laboratory-generated secondary organic aerosol (SOA) or based on field observations at locations more dominated by SOA.

54 ENVIRONMENTAL SCIENCES↗

BLOC Site - ASSIST Thermodynamic Retrievals TROPoe v0.18 / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). This is a post-processed dataset and recommended for use. The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Michaud-Belleau et al. 2025) operated by NOAA Physical Sciences Laboratory (PSL) on Block Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a collocated surface tower operated by NOAA PSL. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY. The TROPoe docker container (version 0.18) is available from Docker Hub at https://hub.docker.com/r/davidturner53/tropoe/tags, and the source code code is available in the GitHub repository https://github.com/OAR-atmospheric-observations/TROPoe.

17 WIND ENERGY↗

NANT Site - ASSIST Thermodynamic Retrievals TROPoe v0.18 / Derived Data

This dataset contains daily files with thermodynamic profiles retrieved with the optimal estimation physical retrieval TROPoe (Turner and Löhnert 2014; Turner and Blumberg 2019; Turner and Löhnert 2021). This is a post-processed dataset and recommended for use. The profiles are retrieved every 10 minutes from instantaneous radiances observed with an Atmospheric Sounder Spectrometer by Infrared Spectral Technology (ASSIST, Michaud-Belleau et al. 2025) operated by NOAA Physical Sciences Laboratory (PSL) on Nantucket Island for WFIP3. The spectral bands used in the retrieval are in the wavenumber range from 612 - 905.4 cm-1 and are specified in Turner and Löhnert (2021). Additional input data in TROPoe are cloud base height from a collocated ceilometer operated by NOAA GML and temperature, water vapor mixing ratio, and pressure from a collocated surface tower operated by NOAA PSL. In addition to these temporally resolved input data, TROPoe requires an a priori dataset (prior) that provides mean climatological estimates of thermodynamic profiles and specifies how temperature and humidity covary with height as an input (for details see, e.g., Djalalova et al. 2022). The prior is a key component of the retrieval and provides a constraint on the ill-posed inversion problem. A monthly prior was computed from operational radiosonde launches at Upton, NY. The TROPoe docker container (version 0.18) is available from Docker Hub at https://hub.docker.com/r/davidturner53/tropoe/tags, and the source code code is available in the GitHub repository https://github.com/OAR-atmospheric-observations/TROPoe.

17 WIND ENERGY↗

Impact of Load Tap Changer Control Operation Under Microgrid Conditions

Every microgrid is unique in its diversity of assets, operation, and network structure. This uniqueness presents challenges for each microgrid implementation that need to be understood and addressed to prevent power quality concerns, stability issues, and blackouts. In this research work, we present one challenge faced during microgrid operation that could potentially cause a blackout in some microgrid configurations. Through the incorrect operation of the load tap changer controller during an islanding event for a microgrid with generation present on both primary and secondary busses, the primary voltage will increase or decrease beyond allowable bounds, causing a cascading failure. This work presents the issue first with simulation results to demonstrate the phenomenon and then presents results of load tap changer controller operation using a controller-hardware-in-the-loop experiment. Finally, details of the complete sequence of operation and the blackout scenarios are presented and summarized.

blackout↗

First operation and validation of simulations for the divertor cryo-vacuum pump in Wendelstein 7-X

Ten cryo-vacuum pumps (CVPs) were installed in the subdivertor region of each island divertor in the stellarator Wendelstein 7-X (W7-X) and operated for the first time during the recently completed plasma campaign OP2.1. A pumping speed of 70 ± 1 $\frac{m^3}{s}$ was measured during dedicated tests with known hydrogen gas injection. Based on a conductance model, the estimated pumping speed ranges from 86-93 $\frac{m^3}{s}$ for different sticking coefficients between 0.6 and 0.8. After completion of the initial tests the CVPs were operated successfully throughout the campaign, with regeneration performed once a week. Neutral gas pressures in the subdivertor in the range of 10 −4 mbar are well within the molecular flow regime and limit the particle exhaust capabilities of the CVPs. Simulations of the neutral gas pressure in the three-dimensional complex geometry of the subdivertor were performed using the DIVGAS code based on the direct simulation Monte Carlo method and a model implemented in the steady-state thermal package in ANSYS, which are in agreement with the measured values during plasma operation.

Cryo-vacuum pumping↗

Does practice make perfect? Lessons learned from full-scale power system incident response exercise

While threats to the energy sector occur daily, few utilities get the opportunity to fully test out their detection and response mechanisms to advanced threats in the real world. With the high demand for reliability, few grid operators would allow execution of simulated cyber-attacks on their live systems. The DOE-funded Liberty Eclipse project offers a unique opportunity for small and large utilities and coops to practice their combined IT/OT responses to a live red team executing attacks against an isolated power system on an island in New York. Both cyber teams and power operations teams must work together to detect and respond to attacks, even restoring the power system against extreme impacts. Lessons learned from these exercises reveal key takeaways for understanding what a real attack against the electric sector will look like, gaps in execution of the best-laid plans when the pressure of a real event is bearing down, and how organizations can better prepare for advanced attacks by optimizing participation in exercises. This presentation will discuss successes and opportunities for improvement both in how utilities can prepare for and respond to events, as well as how full-scale IT/OT exercises can be coordinated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of microgrid resilience through co-simulation of power system dynamics and communication systems

The interdependence of power and communication systems in smart grid technologies is acknowledged, but difficult to quantify. Communication systems can be essential to maintaining stability in microgrids that are islanded due to extreme events. Though many power system studies assume the presence of communication networks, detailed modeling of power and communication systems for dynamic studies of microgrids is rare. The work presented in this paper develops a framework for power and communication system co-simulation to study the impact of communications system on microgrid stability. An operational use case is examined where a battery energy storage system operates to offset the loss of generation in an islanded microgrid. The framework is evaluated for different communication technologies, network structures, and communication media.

Thekkumparambath Mana, Priya↗

The “Brookhaven Brassie” and the Response to the Three Mile Island Accident

In the mid-1970s, American civil defense authorities became increasingly concerned with the potential threat of fission reactor accidents. Research from the Defense Civil Preparedness Agency began to be aimed not just at the ever-present threat of nuclear warfare, but also peacetime emergencies as part of a "dual use" philosophy. The Brookhaven National Laboratory received funding to create a prototype radioiodine air sampling system, with multiple publications detailing the creation of the air sampler itself and a special CD V-700 survey meter that accompanied it. In late March 1979, the system found its first operational employment at the reactor accident at Three Mile Island, Pennsylvania. Despite successful use and further study, the BNL Air Sampler was not widely fielded by the federal government. However, lessons learned from its employment and development may be applicable to contemporary radiological emergency response.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A fully implicit, asymptotic-preserving, semi-Lagrangian algorithm for the time dependent anisotropic heat transport equation

In this paper, we extend the operator-split asymptotic-preserving, semi-Lagrangian algorithm for time dependent anisotropic heat transport equation proposed in Chacón et al. (2014) [18] to use a fully implicit time integration with backward differentiation formulas. The proposed implicit method can deal with arbitrary heat-transport anisotropy ratios $\mathcal{X}$∥ /$ \mathcal{X}$⟂ $\ggg$ 1 (with $\mathcal{X}$∥, $ \mathcal{X}$⟂ the parallel and perpendicular heat diffusivities, respectively) in complicated magnetic field topologies in an accurate and efficient manner. Further, the implicit algorithm is second-order accurate temporally and demonstrates an accurate treatment at boundary layers (e.g., island separatrices), which was not ensured by the operator-split implementation. The condition number of the resulting algebraic system is independent of the anisotropy ratio, and is inverted with preconditioned GMRES. We propose a simple preconditioner that renders the finite-dimensional linear operator compact, resulting in mesh-independent convergence rates for topologically simple magnetic fields, and convergence rates scaling as ~ (NΔt) 1/4 (with N the total mesh size and Δt the timestep) in topologically complex magnetic-field configurations. We demonstrate the accuracy and performance of the approach with test problems of varying complexity, including an analytically tractable boundary-layer problem in a straight magnetic field, and a topologically complex magnetic field featuring magnetic islands with extreme anisotropy ratios $\mathcal{X}$∥ /$ \mathcal{X}$⟂ = 10 10 ) .

97 MATHEMATICS AND COMPUTING↗