Search NASA⌕ Search

SEARCH · Search NASA

Results for “kernel reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast Bayesian blind deconvolution with Huber Super Gaussian priors

We report expectation Maximization (EM) based inference has already proven to be a very powerful tool to solve blind image deconvolution (BID) problems. Unfortunately, three important problems still impede the application of EM in BID: the undesirable saddle points and local minima caused by highly nonconvex priors, the instability around zero of some of the most interesting sparsity promoting priors, and the intrinsic high computational cost of the corresponding BID algorithm. In this paper we first show how Super Gaussian priors can be made numerically tractable around zero by introducing the family of Huber Super Gaussian priors and then present a fast EM based blind deconvolution method formulated in the image space. In the proposed computational approach, image and kernel estimation are performed by using the Alternating Direction Method of Multipliers (ADMM), which allows to exploit the advantages of FFT computation. For highly nonconvex priors, we propose a Smooth ADMM (SADMM) approach to avoid poor BID estimates. In conclusion, extensive experiments demonstrate that the proposed method significantly outperforms state-of-the-art BID methods in terms of quality of the reconstructions and speed.

97 MATHEMATICS AND COMPUTING↗

Improvements of Nuclear Data Evaluations for Lead Isotopes in Support of Next Generation Lead-Cooled Fast Systems

The neutron evaluation of the isotopes that comprise natural lead were undertaken as a part of DOE-NEUP Project #19-16739. The goal of the project was to update the neutron cross sections to account for new differential measurements and incorporate the most up-to-date physics. Shortcomings in the lead cross sections was made known by several independent reports. The work performed here repeated the simulation of all the “benchmark” validation systems and concluded that the major issue is the scattering cross sections in the major lead isotopes above 100 keV. Re-evaluation of 206,207,208 Pb included both the resolved resonance region and fast region evaluations of the cross sections. Combined these regions cover energies from thermal to 20 MeV. The most drastic improvement is the resolved resonance region evaluation of 208 Pb which is now extended from 1.0 to 1.5 MeV. Parameterization of these resonances in the R-matrix provides a superior reconstruction of not only the experimental cross section but also the scattering distributions via the Blatt-Biedenharn formalism. Fast region evaluations of the three major isotopes were done to include new inelastic experimental data from the neutron Time-of-Flight facility at CERN. The culmination of all the changes to the cross section is a drastic improvement in the scattering kernel as shown in Rensselaer Polytechnic Institute (RPI) Quasi-Differential scattering measurements and improved prediction of keff for fast integral experiments. Alongside the new cross sections, new nuclear data covariance (uncertainties) have been computed and are included in the evaluation. Little is changed in the magnitude of the uncertainties but the correlations within the covariance display non-trivial changes. The new evaluations of 206,207,208 Pb have been submitted to the National Nuclear Data Center to be included in the ENDF/B-VIII.1 library. While the cross sections have been updated extensively, knowledge and modeling of the cross sections between 1.0 and 3.0 MeV for the isotopes remain a challenge. Most notably is the double differential elastic cross section for 208 Pb and 206 Pb. New quasi-differential measurements for pure samples of these two nuclei would go a long way in reducing compensating errors in the evaluations. Qualitatively, the project has produced a prosperous collaboration between the nuclear data group at RPI with staff scientists at Brookhaven National Laboratory, Naval Nuclear Laboratory, Oak Ridge National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratories. Quantitatively this is reflected in seven conference presentations, at least one journal submission, and one doctoral thesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The high level trigger and express data production at STAR

To meet the demands of the Beam Energy Scan phase-II (BES-II) program, the STAR experiment at the Relativistic Heavy Ion Collider (RHIC) developed a dual real-time framework consisting of a High Level Trigger (HLT) and an Express Data Production system (xProduction). The HLT operates online within the Data Acquisition (DAQ) chain on a dedicated multi-core CPU cluster with the option to offload compute-intensive kernels to Xeon Phi coprocessors. It uses parallelized algorithms, such as the Cellular Automaton (CA) Track Finder, to perform rapid tracking, vertexing, and event filtering. This allows it to select events of interest in real time and provide immediate feedback on detector and beam conditions. In contrast, the xProduction workflow runs concurrently and independently of the DAQ loop. It applies near offline-quality calibration and reconstruction within hours of data collection. The xProduction input is the express data stream, whose content can be enriched by HLT trigger/priority selections under DAQ/HLT resource constraints, and it uses the STAR calibration/conditions framework, incorporating online calibration/QA information when available. This enables early preliminary physics analysis, including the reconstruction of rare signals, such as hyperons and hypernuclei. It also provides collaboration-wide access to analysis-ready datasets. Together, the HLT and xProduction systems form a complementary architecture: the HLT performs online event selection while the xProduction chain delivers high-quality results within a short amount of time. This integrated framework has enabled the prompt reconstruction of the $^5_Λ$ He hypernucleus with high statistical significance and the efficient processing of hundreds of millions of heavy-ion collision events. In conclusion, its demonstrated scalability and robustness establish a model for future high-luminosity experiments requiring both online event filtering and rapid access to analysis-quality data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-BRE-06: Evaluation of Patient CT Dose Reconstruction From 3D Diode Array Measurements Using Anthropomorphic Phantoms

Purpose: To compare 3D reconstructed dose of IMRT plans from 3D diode array measurements with measurements in anthropomorphic phantoms. Methods: Six IMRT plans were created for the IROC Houston (RPC) head and neck (H and N) and lung phantoms following IROC Houston planning protocols. The plans included flattened and unflattened beam energies ranging from 6 MV to 15 MV and both static and dynamic MLC tecH and Niques. Each plan was delivered three times to the respective anthropomorphic phantom, each of which contained thermoluminescent dosimeters (TLDs) and radiochromic films (RCFs). The plans were also delivered to a Delta4 diode array (Scandidos, Uppsala, Sweden). Irradiations were done using a TrueBeam STx (Varian Medical Systems, Palo Alto, CA). The dose in the patient was calculated by the Delta4 software, which used the diode measurements to estimate incident energy fluence and a kernel-based pencil beam algorithm to calculate dose. The 3D dose results were compared with the TLD and RCF measurements. Results: In the lung, the average difference between TLDs and Delta4 calculations was 5% (range 2%–7%). For the H and N, the average differences were 2.4% (range 0%–4.5%) and 1.1% (range 0%–2%) for the high- and low-dose targets, respectively, and 12% (range 10%-13%) for the organ-at-risk simulating the spinal cord. For the RCF and criteria of 7%/4mm, 5%/3mm, and 3%/3mm, the average gamma-index pass rates were 95.4%, 85.7%, and 76.1%, respectively for the H and N and 76.2%, 57.8%, and 49.5% for the lung. The pass-rate in the lung decreased with increasing beam energy, as expected for a pencil beam algorithm. Conclusion: The H and N phantom dose reconstruction met the IROC Houston acceptance criteria for clinical trials; however, the lung phantom dose did not, most likely due to the inaccuracy of the pencil beam algorithm in the presence of low-density inhomogeneities. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

A Novel Gradient Projection Approach for Fourier-Based Image Restoration

This work deals with the ill-posed inverse problem of reconstructing a two-dimensional image of an unknown object starting from sparse and nonuniform measurements of its Fourier Transform. In particular, if we consider a priori information about the target image (e.g., the nonnegativity of the pixels), this inverse problem can be reformulated as a constrained optimization problem, in which the stationary points of the objective function can be viewed as the solutions of a deconvolution problem with a suitable kernel. We propose a fast and effective gradient-projection iterative algorithm to provide regularized solutions of such a deconvolution problem by early stopping the iterations. Preliminary results on a real-world application in astronomy are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single Gaussian process method for arbitrary tokamak regimes with a statistical analysis

Abstract Gaussian process regression is a Bayesian method for inferring profiles based on input data. The technique is increasing in popularity in the fusion community due to its many advantages over traditional fitting techniques including intrinsic uncertainty quantification and robustness to over-fitting. This work investigates the use of a new method, the change-point method, for handling the varying length scales found in different tokamak regimes. The use of the Student’s t-distribution for the Bayesian likelihood probability is also investigated and shown to be advantageous in providing good fits in profiles with many outliers. To compare different methods, synthetic data generated from analytic profiles is used to create a database enabling a quantitative statistical comparison of which methods perform the best. Using a full Bayesian approach with the change-point method, Matérn kernel for the prior probability, and Student’s t-distribution for the likelihood is shown to give the best results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward the first gluon parton distribution from the LaMET

Abstract We present progress towards the first unpolarized gluon quasi-parton distribution function (PDF) from lattice quantum chromodynamics using high-statistics measurements for hadrons at two valence pion masses M π ≈ 310 and 690 MeV computed on an a ≈ 0.12 fm ensemble with 2 + 1 + 1-flavors of highly improved staggered quark generated by the MILC collaboration. In this study, we consider two gluon operators for which the hybrid-ratio renormalization matching kernels have been recently derived and a third operator that has been used in prior pseudo-PDF studies of the gluon PDFs. We compare the matrix elements for each operator for both the nucleon and pion, at both pion masses, and using two gauge-smearing techniques. Focusing on the more phenomenologically studied nucleon gluon PDF, we compare the ratio and hybrid-ratio renormalized matrix elements at both pion masses and both smearings to those reconstructed from the nucleon gluon PDF from the CT18 global analysis. We identify the best choice of operator to study the gluon PDF and present the first gluon quasi-PDF under some caveats. Additionally, we explore the recent idea of Coulomb gauge fixing to improve signal at large Wilson-line displacement and find it could be a major help in improving the signal in the gluon matrix elements. This work helps identify the best operator for studying the gluon quasi-PDF, shows higher hadron boost momentum is needed to implement hybrid-ratio renormalization reliably, and suggests the need to study more diverse set of operators with their corresponding perturbative calculations for hybrid-ratio renormalization to further gluon quasi-PDF study.

Good, William (ORCID:0000000184281003)↗

TuckerMPI: A Parallel C++/MPI Software Package for Large-scale Data Compression via the Tucker Tensor Decomposition

With this study, our goal is compression of massive-scale grid-structured data, such as the multi-terabyte output of a high-fidelity computational simulation. For such data sets, we have developed a new software package called TuckerMPI, a parallel C++/MPI software package for compressing distributed data. The approach is based on treating the data as a tensor, i.e., a multidimensional array, and computing its truncated Tucker decomposition, a higher-order analogue to the truncated singular value decomposition of a matrix. The result is a low-rank approximation of the original tensor-structured data. Compression efficiency is achieved by detecting latent global structure within the data, which we contrast to most compression methods that are focused on local structure. In this work, we describe TuckerMPI, our implementation of the truncated Tucker decomposition, including details of the data distribution and in-memory layouts, the parallel and serial implementations of the key kernels, and analysis of the storage, communication, and computational costs. We test the software on 4.5 and 6.7 terabyte data sets distributed across 100 s of nodes (1,000 s of MPI processes), achieving compression ratios between 100 and 200,000×, which equates to 99--99.999% compression (depending on the desired accuracy) in substantially less time than it would take to even read the same dataset from a parallel file system. Moreover, we show that our method also allows for reconstruction of partial or down-sampled data on a single node, without a parallel computer so long as the reconstructed portion is small enough to fit on a single machine, e.g., in the instance of reconstructing/visualizing a single down-sampled time step or computing summary statistics. The code is available at https://gitlab.com/tensors/TuckerMPI.

97 MATHEMATICS AND COMPUTING↗

Interparameter tradeoff quantification for isotropic-elastic full-waveform inversion with various model parameterizations

Simultaneous determination of multiple physical parameters using full-waveform inversion (FWI) suffers from interparameter tradeoff diffculty. Analyzing the interparameter tradeoffs in different model parameterizations of isotropic-elastic FWI, and thus determining the appropriate model parameterization, are critical for efficient inversion and obtaining reliable inverted models. Five different model parameterizations are considered and compared including velocity-density, modulus-density, impedance-density and two velocity-impedance parameterizations. The scattering radiation patterns are first used for interparameter tradeoff analysis. Furthermore, a new framework is developed to evaluate the interparameter tradeoff based upon multiparameter Hessian-vector products: multiparameter point spread functions (MPSFs) and interparameter contamination sensitivity kernels (ICSKs), which provide quantitative, second-order measurements of the interparameter contaminations. In the numerical experiments, the interparameter tradeoffs in various model parameterizations are evaluated using the MPSFs and ICSKs. Inversion experiments are then carried out with simple Gaussian-anomaly models and complex Marmousi model. Overall, the parameterization of P-wave velocity, S-wave velocity and density and the parameterization of P-wave velocity, S-wave velocity and S-wave impedance perform best for reconstructing all of the physical parameters. Isotropic-elastic FWI of the Hussar low frequency dataset with various model parameterizations verifies the conclusions.

58 GEOSCIENCES↗

Improved Cross Section Generation Capability of Griffin in FY22

The Griffin code is a Multiphysics Object-Oriented Simulation Environment (MOOSE) based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. The code includes a variety of deterministic steady-state transport solvers for fixed source, k-eigenvalue, adjoint, and subcritical multiplication as well as transient solvers for spatial dynamics with the improved quasi-static method. Griffin uses cross section data in the ISOXML format generated from external deterministic or Monte Carlo cross section generation codes. In recent years, the MC 2 -3 modules have been added to Griffin for fast reactor cross section generation, and the self-shielding application programming interface (SSAPI) was implemented in the ISOXML module for thermal reactor cross section generation. The on-the-fly slowing down method and double-heterogeneity treatment have been implemented to SSAPI and verified against particulate fuel-bearing graphite-moderated thermal reactor problems with high accuracy. This year, work has been focused on improving the cross section generation capability of ISOXML and streamlining the cross section generation procedures. In addition, the form function data were added to ISOXML in order to support the pin power reconstruction capability that was newly implemented in Griffin in this fiscal year. To facilitate the cross section generation using MC 2 -3 and SSAPI in Griffin, the cross section generation workflows have been set up for both fast and thermal spectrum reactors. The MOOSE action system tool was devised for fast spectrum problems, and the MOOSE stochastic tool was adopted to the branch calculation procedure for thermal spectrum problems. Meanwhile, to ensure the accuracy of group-constants, the thermal up-scattering kernel calculator accounting for resonance scattering was implemented in ISOXML, demonstrating the accurate computation of a Doppler-broadened scattering kernel of any Legendre order within a reasonable timescale. Other aspects of ISOXML, such as deletion solver and data, documentation, ISOXML file management, and the interface for Mixture, were improved as well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant improvements in r{sup ¯} and d{sup ¯}{sub 20} (p < 0.05), with density scaled metrics also showing higher r{sup ¯} than for unscaled versions (p < 0.02). r{sup ¯} and d{sup ¯}{sub 20} were also sensitive to image quality, with statistically significant improvements using standard (as opposed to gated) PET images and with application of median filtering. Conclusions: The use of modified CT ventilation metrics, in conjunction with PET-Galligas and careful application of image filtering has resulted in improved correlation compared to earlier studies using nuclear medicine ventilation. However, CT ventilation and PET-Galligas do not always provide the same functional information. The authors have demonstrated that the agreement can improve for CT ventilation metrics incorporating a tissue density scaling, and also with increasing PET image quality. CT ventilation imaging has clear potential for imaging regional air volume change in the lung, and further development is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compadre Toolkit

The Compadre Toolkit solves a minimization problem, that once solved allows a user to reconstruct a function from sample data collected from a cloud of data sites. The solution to this minimization can also be used to assemble a linear system that can be solved numerically using some other software. The minimization problem the toolkit solves is to find the optimal finite polynomial in a user specified finite dimensional space with regards to minimizing an objective function which measures a linear sampling functional applied to the polynomial, compared to the same sampling functional applied to the source function, weighted by a positive kernel that has compact support.

SciDAC↗

Active Learning Surrogates for Integrating Electron Microscopy and Computational Insights from Simulations in Autonomous Experiments

Artificial Intelligence (AI) combined with simulations and experiments has great potential to accelerate scientific discovery across technology and pharmaceuticals. However, the gap between simulations and experiments is challenging due to disparities in time and scale, making it difficult to estimate properties like energy and electronic states from experiments, and to provide feedback based on theoretical insights.Our research addresses the challenge by developing unique deep kernel based surrogate models that learns from microscopic images, mapping structural features to energy differences from defect formation. We start with full-training using simulated images to determine optimal settings, establishing a baseline for active learning. Using these settings from the baseline, active learning is trained, and predicts structures along simulation trajectories based on uncertainty and energetic stability, thus reducing data requirements, simulation time and computational costs. The results demonstrate that the model achieves a low average error margin of approximately 0.03 meV, indicating good performance. To enhance feature extraction and reconstruction capabilities, we developed an autoencoder-decoder as additional surrogate to create latent space to capture essential features, enabling precise comparisons between simulations and experiments. The results from this model achieved a reconstruction loss of around 0.2 and accurately reconstructed molecular structures.Overall, this work advances the steering of experiments through computational simulations by employing a surrogate models that actively predicts the trajectories of structural evolution, achieving time-to-solution comparable to experimental measurements.

Saranathan, Gayathri [Hewlett-Packard]↗

Experience with the alpaka performance portability library in the CMS software

ion Library for Parallel Kernel Acceleration) is a header-only C++ library that provides performance portability across different back-ends, abstracting the underlying levels of parallelism. It supports serial and parallel execution on CPUs, and extremely parallel execution on NVIDIA, AMD and Intel GPUs.This contribution will show how alpaka is used in the CMS software to develop and maintain a single code base; to use different toolchains to build the code for each supported back-end, and link them into a single application; to seamlessly select the best backend at runtime, and implement portable reconstruction algorithms that run efficiently on CPUs and GPUs from different vendors. It will describe the validation and deployment of the alpaka-based implementation in the CMS High Level Trigger, and highlight how it achieves near-native performance.

Alawieh, Jaafar [CERN]↗

Summary Statistics for Fun Dough Data Acquired at LLNL

Using x-ray computerized tomography (CT), we have characterized the x-ray linear attenuation coefficients (LAC) of a Play Dough{trademark}-like product, Fun Dough{trademark}, designated as PD. Table 1 gives the first-order statistics for each of four CT measurements, estimated with a Gaussian kernel density estimator (KDE) analysis. The mean values of the LAC range from a high of about 2100 LMHU{sub D} at 100kVp to a low of about 1100 LMHU{sub D} at 300kVp. The standard deviation of each measurement is around 1% of the mean. The entropy covers the range from 3.9 to 4.6. Ordinarily, we would model the LAC of the material and compare the modeled values to the measured values. In this case, however, we did not have the composition of the material and therefore did not model the LAC. Using a method recently proposed by Lawrence Livermore National Laboratory (LLNL), we estimate the value of the effective atomic number, Z{sub eff}, to be near 8.5. LLNL prepared about 50mL of the Fun Dough{trademark} in a polypropylene vial and firmly compressed it immediately prior to the x-ray measurements. Still, layers can plainly be seen in the reconstructed images, indicating that the bulk density of the material in the container is affected by voids and bubbles. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the data capture and image reconstruction are given in this report. Additional details may be found in the experimental SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an 80% central-core segment of volume elements ('voxels') lying completely within the specimen, away from the walls of the polypropylene vial. All of the voxels within this central core, including those comprised of voids and inclusions, are included in the statistics. We then calculated the mean value, standard deviation and entropy for (a) the four image segments and for (b) their digital gradient images. (A digital gradient image of a given image was obtained by taking the absolute value of the difference between the initial image and that same image offset by one voxel horizontally, parallel to the rows of the x-ray detector array.) The statistics of the initial image of LAC values are called 'first order statistics;' those of the gradient image, 'second order statistics.'

99 GENERAL AND MISCELLANEOUS↗

Summary Statistics for Homemade ?Play Dough? -- Data Acquired at LLNL

Using x-ray computerized tomography (CT), we have characterized the x-ray linear attenuation coefficients (LAC) of a homemade Play Dough{trademark}-like material, designated as PDA. Table 1 gives the first-order statistics for each of four CT measurements, estimated with a Gaussian kernel density estimator (KDE) analysis. The mean values of the LAC range from a high of about 2700 LMHU{sub D} 100kVp to a low of about 1200 LMHUD at 300kVp. The standard deviation of each measurement is around 10% to 15% of the mean. The entropy covers the range from 6.0 to 7.4. Ordinarily, we would model the LAC of the material and compare the modeled values to the measured values. In this case, however, we did not have the detailed chemical composition of the material and therefore did not model the LAC. Using a method recently proposed by Lawrence Livermore National Laboratory (LLNL), we estimate the value of the effective atomic number, Z{sub eff}, to be near 10. LLNL prepared about 50mL of the homemade 'Play Dough' in a polypropylene vial and firmly compressed it immediately prior to the x-ray measurements. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the data capture and image reconstruction are given in this report. Additional details may be found in the experimental SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an 80% central-core segment of volume elements ('voxels') lying completely within the specimen, away from the walls of the polypropylene vial. All of the voxels within this central core, including those comprised of voids and inclusions, are included in the statistics. We then calculated the mean value, standard deviation and entropy for (a) the four image segments and for (b) their digital gradient images. (A digital gradient image of a given image was obtained by taking the absolute value of the difference between the initial image and that same image offset by one voxel horizontally, parallel to the rows of the x-ray detector array.) The statistics of the initial image of LAC values are called 'first order statistics;' those of the gradient image, 'second order statistics.'

99 GENERAL AND MISCELLANEOUS↗

Sierra/RKPM: Current State and Applications

The Reproducing Kernel Particle Method (RKPM), a meshfree method, has been implemented in Sandia's Sierra/Solid Mechanics in a collaboration between Sandia and the University of California San Diego's Center for Extreme Events Research (UCSD/CEER). Meshfree methods, like RKPM, have an advantage over mesh-based methods, like the Finite Element Method (FEM), in applications where achieving or maintaining a quality mesh becomes burdensome or impractical. For example, using FEM for problems with very large deformations will result in poor element Jacobians which causes problems with the parametric mapping. RKPM constructs the approximation functions in the physical domain, circumventing the parametric mapping issue. Also, reconstructing the approximation functions at very large deformations is straight-forward. RKPM has an advantage over traditional meshfree methods such as Smoothed-Particle Hydrodynamics (SPH) due to its ability to reproduce linear or higher-order functions exactly. This removes the tensile instabilities that are present in SPH and allows preservation of angular momentum. The point of this memo is to explore the capabilities and limitations of the current implementation by testing it on three different applications: 1) a quasi-static ductile shearing problem 2) a dynamic concrete panel perforation problem and 3) a set of dynamic metal panel perforation problems. In summary, areas where RKPM appears to be a promising alternative to current methods have been identified. Also, outstanding inefficiencies and issues (bugs) with code are noted, ways to improve the capabilities using material from literature are mentioned and areas deserving of new research are highlighted.

42 ENGINEERING↗