Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer

We carry out the calibration of an ultraviolet spectrometer by using a cryogenic electrical-substitution radiometer and intensity-stabilized laser sources. A comparison of the error budgets for the laser-based calibration described here and for a calibration using a type-FEL tungsten spectral-irradiance standard indicates that this technique could provide an improvement of a factor of about three in the uncertainty of the spectrometer calibration, resulting in an absolute accuracy (standard deviation of three) of about 1 percent at 257 nm. The technique described here might significantly improve the accuracy of calibrations on NASA ozone-monitoring and solar ultraviolet-monitoring spectrophotometers when used to complement present procedures that employ lamps and the SURF II synchrotron ultraviolet radiation facility at the National Institute of Standards and Technology.

Jauniskis, L.↗

Cryogenic monocrystalline silicon Fabry-Perot cavity for the stabilization of laser frequency

A 1.6 kg silicon monocrystal was used to make a Fabry-Perot optical cavity operated at cryogenic temperatures. High-resolution thermal expansion measurements were made as the silicon cooled to 4.2 K, in order to characterize the cavity as a length reference standard. A helium-neon laser was then locked to a transmission resonance at liquid-helium temperatures, and the laser frequency tracked the cavity resonance with error fluctuations at the level of 10 Hz/sq rt Hz in the bandwidth dc to 1 Hz. Implications of the combined set of data, thermal expansion plus frequency-tracking fluctuations, for using such a system as a frequency standard are discussed.

Richard, J.-P.↗

Construction and Calibration of a Difference Frequency Laser Spectrometer and New THZ Frequency Measurements of water and Ammonia

A three laser system based on 852nm DBR lasers has been constructed and used to generate radiation in the 750 GHz to 1600 GHz frequency region. The system works by locking two of the three lasers to modes of an ultra low expansion Fabry-Perot cavity. The third laser is offset locked to one of the cavity locked lasers with conventional microwave techniques. The signal from the offset laser and the other cavity locked laser are injected into a Master Oscillator Power Amplifier (MOPA), amplified and focused on a low temperature grown GaAs photomixer, which radiates the difference frequency. The system has been calibrated with molecular lines to better than one part in 10(exp 7). In this paper we present the application of this system to the v(sub 2) in inversion band of Ammonia and the ground and v(sub 2) states of water. A discussion of the system design, the calibration and the new spectral measurements will be presented.

Pearson, J. C.↗

Single mode, short cavity, Pb-salt diode lasers operating in the 5, 10, and 30-microns spectral regions

Pb-salt diode lasers are being used as frequency-tunable infrared sources in high resolution spectroscopy and heterodyne detection applications. Recent advances in short cavity, stripe-geometry laser configurations have led to significant increases in maximum CW operating temperature, single mode operation, and increased single mode tuning range. This paper describes short cavity, stripe geometry lasers operating in the 5, 10, and 30-microns spectral regions, with single mode tuning ranges of over 6/cm.

Linden, K. J.↗

Waveguide CO2 laser gain: Dependence on gas kinetic and discharge properties

Using a simple rate equation approach the gas kinetic and discharge properties of waveguide CO2 lasers were examined. The dependence was calculated of the population inversion and laser small signal gain on gas pressure, gas mixture, pumping rate (discharge current), tube bore diameter, and wall temperature. At higher pressures the gain is optimized by using more helium rich mixtures and smaller bore diameters. The dependence of laser tunability on the gas kinetic properties and cavity losses was determined, it was found that for loss cavities the laser tunability may substantially exceed the molecular fullwidth at half maximum. The more helium rich gas mixtures give greater tunability when cavity losses are small and less tunability when cavity losses are large. The role of the various gases in the waveguide CO2 laser is the same as that in conventional devices, by contrast with conventional lasers, the waveguide laser transition is homogeneously broadened. The dependence of gain on gas pressure and other kinetic and discharge properties differs substantially from that predicted by scaling results from conventional low pressure lasers.

Cohen, S. C.↗

Waveguide CO2 laser gain - Dependence on gas kinetic and discharge properties

A simple rate-equation approach is used to examine the gas-kinetic and discharge properties of waveguide CO2 lasers. The dependence of the population inversion and laser small-signal gain on gas pressure, gas mixture, pumping rate (discharge current), tube bore diameter, and wall temperature is calculated along with the dependence of laser tunability on the gas-kinetic properties and cavity losses. It is found that for low-loss cavities, the laser tunability may substantially exceed the molecular full width at half-maximum. Furthermore, the more helium-rich gas mixtures give greater tunability when cavity losses are small, and less tunability when cavity losses are large. By contrast with conventional lasers, the waveguide-laser transition is homogeneously broadened. Thus, the dependence of gain on gas pressure and other kinetic properties differs substantially from that predicted by scaling results from conventional low-pressure lasers.

Cohen, S. C.↗

Scaling blackbody laser to high powers

Lasers pumped by solar heated blackbody cavities have potential for multimegawatt power beaming in space. There are two basic types of blackbody lasers; cavity pumped and transfer system. The transfer system is judged to be more readily scalable to high power. In this system, either N2 or CO is heated by the blackbody cavity then transferred into the laser cavity where CO2 is injected. The N2-CO2 system was demonstrated, but probably has lower efficiency than the CO-CO system. The characteristics of potential transfer laser systems are outlined.

Deyoung, R. J.↗

Proposed distributed feedback crystal cavities for X-ray lasers

The use of zeolite crystals in distributed feedback crystal cavities for X-ray emissions is proposed. The zeolite crystals can guide the emitted X rays and can also generate the feedback necessary for self-sustained oscillation. A table lists the parameters of some typical zeolite crystals.

Elachi, C.↗

Development of Fiber-Based Laser Systems for LISA

We present efforts on fiber-based laser systems for the LISA mission at the NASA Goddard Space Flight Center. A fiber-based system has the advantage of higher robustness against external disturbances and easier implementation of redundancies. For a master oscillator, we are developing a ring fiber laser and evaluating two commercial products, a DBR linear fiber laser and a planar-waveguide external cavity diode laser. They all have comparable performance to a traditional NPRO at LISA band. We are also performing reliability tests of a 2-W Yb fiber amplifier and radiation tests of fiber laser/amplifier components. We describe our progress to date and discuss the path to a working LISA laser system design.

Numata, Kenji↗

Fundamental Limit of 1/f Frequency Noise in Semiconductor Lasers Due to Mechanical Thermal Noise

So-called 1/f noise has power spectral density inversely proportional to frequency, and is observed in many physical processes. Single longitudinal-mode semiconductor lasers, used in variety of interferometric sensing applications, as well as coherent communications, exhibit 1/f frequency noise at low frequency (typically below 100kHz). Here we evaluate mechanical thermal noise due to mechanical dissipation in semiconductor laser components and give a plausible explanation for the widely-observed 1/f frequency noise, applying a methodology developed for fixed-spacer cavities for laser frequency stabilization. Semiconductor-laser's short cavity, small beam radius, and lossy components are expected to emphasize thermal-noise-limited frequency noise. Our simple model largely explains the different 1/f noise levels observed in various semiconductor lasers, and provides a framework where the noise may be reduced with proper design.

Numata, K.↗

Laser Scanner for Tile-Cavity Measurement

Irregular surfaces mapped and digitized for numerical-control machinery. Fast, accurate laser scanning system measures size and shape of cavity without making any physical contact with cavity and walls. Measurements processed into control signals for numerically controlled machining of tile or block to fit cavity. System generates map of grid points representing cavity and portion of outer surface surrounding cavity. Map data used to control milling machine, which cuts tile or block to fit in cavity.

Yoshino, Stanley Y.↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

A resonant cavity second harmonic generation system has been developed to produce 369.4 nm radiation from a 738.8 nm diode laser with 10 mW nominal output power. This system utilizes a polarization technique to lock the cavity to the laser frequency. In this paper we report on an evaluation of the system using a Titanium:Sapphire laser as the input source, and preliminary results with a diode laser source. To our knowledge, this is the deepest uv light ever produced by frequency-doubling a diode laser.

Williams, A.↗

LISA Laser Development in the US

Lowering phase noise: 1) optimize optical cavity reflectivity slope to strong feedback to low noise. 2) optimize gain chip for low loss to low noise. 3) select gain chip for lowest 1/f noise.

External Cavity Laser↗

Whispering Gallery Mode Resonators as Optical Reference Cavities

Highly stabilized lasers are an increasingly valuable tool for metrology. For many applications, however, existing Fabry Perot systems are too bulky and cumbersome. We are investigating the use of miniature monolithic whispering gallery mode resonators as reference cavities for laser stabilization. We seek to exploit the benefit of small size and vibration resistance by suppressing thermally induced frequency fluctuations. We have theoretically investigated the viability of using a thin-film coating to achieve temperature compensation. We have experimentally investigated an active temperature stabilization scheme based on birefringence in a crystalline resonator. We also report progress of laser locking to the resonators.

optical frequency↗