Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser frequency noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurements of a supersonic velocity in a nitrogen flow using inverse Raman spectroscopy

Results are presented for supersonic molecular flow-velocity measurements using inverse Raman spectroscopy. The flow velocity, temperature, and density of flowing N2 molecules are measured because of potential wind-tunnel applications. Uncertainties of less than 5% are found for the velocity measurements, while the uncertainties are about 10% for the temperature and density measurements. The laser probe is stabilized by using I2 fluorescence, and I2 saturated absorption is utilized to provide an absolute frequency reference. Differential detection techniques are employed to reduce detection noise.

Herring, G. C.↗

Filter induced errors in laser anemometer measurements using counter processors

Simulations of laser Doppler anemometer (LDA) systems have focused primarily on noise studies or biasing errors. Another possible source of error is the choice of filter types and filter cutoff frequencies. Before it is applied to the counter portion of the signal processor, a Doppler burst is filtered to remove the pedestal and to reduce noise in the frequency bands outside the region in which the signal occurs. Filtering, however, introduces errors into the measurement of the frequency of the input signal which leads to inaccurate results. Errors caused by signal filtering in an LDA counter-processor data acquisition system are evaluated and filters for a specific application which will reduce these errors are chosen.

Oberle, L. G.↗

Filter induced errors in laser anemometry using counter-processor

Simulations of laser Doppler anemometer (LDA) systems have focused primarily on noise studies or biasing errors. Another possible source of error is the choice of filter types and filter cutoff frequencies. Before it is applied to the counter portion of the signal processor, a Doppler burst is filtered to remove the pedestal and to reduce noise in the frequency bands outside the region in which the signal occurs. Filtering, however, introduces errors into the measurement of the frequency of the input signal which leads to inaccurate results. Errors caused by signal filtering in an LDA counter-processor data acquisition system are evaluated and filters for a specific application will reduce these errors are chosen.

Oberle, L. A.↗

The role of laser coherence in long-range vibration measurements

In this paper, the temporal coherence effect of a laser oscillator will be critically examined using existing laser frequency stability data in the time domain by first converting them to the frequency domain. We limit our discussion to CO2 lasers. To be more specific, our presentation will include the following items: (1) a review of the definitions and representations of laser oscillator frequency stability; (2) a methodology will be developed for determining the dynamic range of vibration measurements; (3) the methodology will show that the conversion of the laser frequency stability from the time domain to the frequency domain can be performed effectively in the optical region; and (4) because of a finite time delay, the phase noise is reduced for offset frequencies close to the carrier frequency.

Eng, R. S.↗

Noise in Intense Electron Bunches (Final Technical Report)

The goal of this project is to investigate density fluctuations in electron bunches. Noise and density fluctuations in relativistic electron bunches, accelerated in a linac, are of critical importance to various Coherent Electron Cooling (CEC) concepts as well as to free-electron lasers (FELs). For CEC, the beam noise results in additional diffusion that counteracts cooling; and if this noise is not controlled at sufficiently low level, the noise heating effects can overcome cooling. There have been several proposals in the past to suppress the noise in the beam in the frequency range of interest in order to optimize the cooling effects. In SASE FELs a microwave instability starts from the initial noise in the beam and eventually leads to the beam microbunching yielding coherent radiation, and the initial noise in the FEL bandwidth plays a useful role. In seeded FELs, in contrast, such noise interferes with the seed signal, so that reducing noise at the initial seed wavelength would lower the seed laser power requirement. Our major goals were (1) to measure the electron beam density noise level in a 0.5 – 10 um wavelength range, (2) to predict the beam noise level in order to compare with the measurements, and (3) as a stretch goal, to find mechanisms that affect the beam noise to control its level in a predictable manner.

43 PARTICLE ACCELERATORS↗

Simulation Study of a Follow-on Gravity Mission to GRACE

The gravity recovery and climate experiment (GRACE) has been providing monthly estimates of the Earth's time-variable gravity field since its launch in March 2002. The GRACE gravity estimates are used to study temporal mass variations on global and regional scales, which are largely caused by a redistribution of water mass in the Earth system. The accuracy of the GRACE gravity fields are primarily limited by the satellite-to-satellite range-rate measurement noise, accelerometer errors, attitude errors, orbit errors, and temporal aliasing caused by unmodeled high-frequency variations in the gravity signal. Recent work by Ball Aerospace and Technologies Corp., Boulder, CO has resulted in the successful development of an interferometric laser ranging system to specifically address the limitations of the K-band microwave ranging system that provides the satellite-to-satellite measurements for the GRACE mission. Full numerical simulations are performed for several possible configurations of a GRACE Follow-On (GFO) mission to determine if a future satellite gravity recovery mission equipped with a laser ranging system will provide better estimates of time-variable gravity, thus benefiting many areas of Earth systems research. The laser ranging system improves the range-rate measurement precision to approximately 0.6 nm/s as compared to approx. 0.2 micro-seconds for the GRACE K-band microwave ranging instrument. Four different mission scenarios are simulated to investigate the effect of the better instrument at two different altitudes. The first pair of simulated missions is flown at GRACE altitude (approx. 480 km) assuming on-board accelerometers with the same noise characteristics as those currently used for GRACE. The second pair of missions is flown at an altitude of approx. 250 km which requires a drag-free system to prevent satellite re-entry. In addition to allowing a lower satellite altitude, the drag-free system also reduces the errors associated with the accelerometer. All simulated mission scenarios assume a two satellite co-orbiting pair similar to GRACE in a near-polar, near-circular orbit. A method for local time variable gravity recovery through mass concentration blocks (mascons) is used to form simulated gravity estimates for Greenland and the Amazon region for three GFO configurations and GRACE. Simulation results show that the increased precision of the laser does not improve gravity estimation when flown with on-board accelerometers at the same altitude and spacecraft separation as GRACE, even when time-varying background models are not included. This study also shows that only modest improvement is realized for the best-case scenario (laser, low-altitude, drag-free) as compared to GRACE due to temporal aliasing errors. These errors are caused by high-frequency variations in the hydrology signal and imperfections in the atmospheric, oceanographic, and tidal models which are used to remove unwanted signal. This work concludes that applying the updated technologies alone will not immediately advance the accuracy of the gravity estimates. If the scientific objectives of a GFO mission require more accurate gravity estimates, then future work should focus on improvements in the geophysical models, and ways in which the mission design or data processing could reduce the effects of temporal aliasing.

Loomis, Bryant D.↗

Pseudorandom Noise Code-Based Technique for Thin Cloud Discrimination with CO2 and O2 Absorption Measurements

NASA Langley Research Center is working on a continuous wave (CW) laser based remote sensing scheme for the detection of CO2 and O2 from space based platforms suitable for ACTIVE SENSING OF CO2 EMISSIONS OVER NIGHTS, DAYS, AND SEASONS (ASCENDS) mission. ASCENDS is a future space-based mission to determine the global distribution of sources and sinks of atmospheric carbon dioxide (CO2). A unique, multi-frequency, intensity modulated CW (IMCW) laser absorption spectrometer (LAS) operating at 1.57 micron for CO2 sensing has been developed. Effective aerosol and cloud discrimination techniques are being investigated in order to determine concentration values with accuracies less than 0.3%. In this paper, we discuss the demonstration of a pseudo noise (PN) code based technique for cloud and aerosol discrimination applications. The possibility of using maximum length (ML)-sequences for range and absorption measurements is investigated. A simple model for accomplishing this objective is formulated, Proof-of-concept experiments carried out using SONAR based LIDAR simulator that was built using simple audio hardware provided promising results for extension into optical wavelengths.

Campbell, Joel F.↗

Plan for compensation of self-gravity on ST-7/DRS

The Space Technology 7 (ST-7) payload, flying on the Laser Interferometer Space Antenna (LISA) Pathfinder (LPF) mission, will demonstrate drag-free control of a test mass with acceleration disturbances below 3x10-14 m/s2/(square root)Hz. Low frequency acceleration noise introduced by the electrostatic force needed to counter static mass distribution imbalance is expected to be a significant contributor to the acceleration noise budget. For this reason, the self-gravity (due to mass imbalance) is minimized by adding trim mass to bring the total differential acceleration between the two test masses due to self-gravity below 5x10-10 m/s2 in any axis and the DC acceleration gradient due to self-gravity below 4x10-8 m/s2/m in any axis of either test mass. A plan has been established to develop the distribution and placement of the compensation masses. Compensation for the self-gravity effects on the two test masses is handled in a two step process. A nominal compensation mass is defined and incorporated early and is located very near the test masses. The final trimming for self-gravity occurs after the integration on the spacecraft with small mass added externally to the test mass vacuum enclosures. The plan identifies three preliminary points in the hardware maturity where the trimming to the as-built configuration can take place: (1) during build-up of the sensor vacuum enclosure, (2) prior to delivery of the integrated ST-7 to Europe, and (3) prior to environmental testing of the integrated LPF system. The sensitivity of the self-gravity to knowledge errors in the actual mass distribution is taken into account in the determination of final trimming opportunities and mounting locations.

acceleration noise↗

Positive- and negative-frequency noise from an ensemble of two-level fluctuators

The analysis of charge noise based on the Bloch-Redfield treatment of an ensemble of dissipative two-level fluctuators generally results in a violation of the fluctuation-dissipation theorem. The standard Markov approximation (when applied to the two-level fluctuators coupled to a bath) can be identified as the main origin of this failure. The resulting decoherence rates only involve the bath response at the fluctuator frequency, and thus completely neglect the effects of frequency broadening. A systematic and computationally convenient way to overcome this issue is to employ the spectator-qubit method: by coupling an auxiliary qubit to the two-level fluctuator ensemble, an analytical approximation for S(ω) fully consistent with the fluctuation-dissipation theorem can be obtained. We discuss the resulting characteristics of the noise which exhibits distinct behavior over several frequency ranges, including a 1/f to 1/f2 crossover with a T3 temperature dependence of the crossover frequency.

2-dimensional systems↗

Signal to noise ratio calculation for fiber optics links

The signal to noise ratio (SNR) effect upon the maximum transmission length of a fiberoptic system is discussed. The relationships of different system parameters are discussed. A general formula to obtain the SNR of a single mode fiberoptic system is derived. The SNR attainable with single mode and multimode fiber optics links was calculated from fundamental noise considerations. It was found that for single mode fibers, laser noise dominates the noise contributions for links less than 30 km long, while thermal noise dominates for longer links. Multimode fibers degrade SNR for long links because of intermode dispersion. For frequency standard transmission, as long as the baseband modulation signals are within the bandwidth of the fibers, respectable SNR can be attained with low loss fibers (approximately 1 dB/km) for links as long as 70 km. For wideband transmission SNR is decreased by a factor equal to the ratio of the bandwidth.

Lau, K. Y.↗

433 micron laser heterodyne observations of galactic CO from Mauna Kea

A submillimeter heterodyne radiometer, developed for astronomical applications, uses an optically pumped laser local oscillator and a quasi-optical Schottky diode mixer. The resultant telescope-mounted system, which has a noise temperature less than 4000 K (double sideband) and high frequency and spatial resolution, has been used to detect the J = 6 to 5 rotational transition of carbon monoxide at 434 micrometers in the Orion molecular clouds. The measurements, when compared with previous millimeter-wave data, indicate that the broad carbon monoxide emission feature is produced by an optically thin gas whose temperature exceeds 180 K.

Buhl, D.↗

High Temperature Superconductor/Semiconductor Hybrid Microwave Devices and Circuits

Contents include following: film deposition technique; laser ablation; magnetron sputtering; sequential evaporation; microwave substrates; film characterization at microwave frequencies; complex conductivity; magnetic penetration depth; surface impedance; planar single-mode filters; small antennas; antenna arrays phase noise; tunable oscillations; hybrid superconductor/semiconductor receiver front ends; and noise modeling.

Romanofsky, Robert R.↗

Fiber-optic delay-line stabilization of heterodyne optical signal generator and method using same

The present invention is a laser heterodyne frequency generator system with a stabilizer for use in the microwave and millimeter-wave frequency ranges utilizing a photonic mixer as a photonic phase detector in a stable optical fiber delay-line. Phase and frequency fluctuations of the heterodyne laser signal generators are stabilized at microwave and millimeter wave frequencies by a delay line system operating as a frequency discriminator. The present invention is free from amplifier and mixer 1/.function. noise at microwave and millimeter-wave frequencies that typically limit phase noise performance in electronic cavity stabilized electronic oscillators. Thus, 1/.function. noise due to conventional mixers is eliminated and stable optical heterodyne generation of electrical signals is achieved.

Logan, Ronald T.↗

Testbed for LISA Photodetectors

The Laser Interferometer Space Antenna (LISA) is a gravitational wave observatory consisting of three spacecraft separated by 5 million km in an equilateral triangle whose center follows the Earth in orbit around the Sun but offset in orbital phase by 20 degrees. LISA is designed to observe sources in the frequency range of 0.1 mHz-100 mHz by measuring fluctuations of the inter-spacecraft separation with laser interferometry. Quadrant photodetectors are used to measure both separation and angular orientation. Noise level, phase and amplitude inhomogeneities of the semiconductor response, and channel cross-talk between quadrant cells need to be assessed in order to ensure the 10 pm/Square root(Hz) sensitivity required for the interferometric length measurement in LISA. To this end, we are currently developing a testbed that allows us to evaluate photodetectors to the sensitivity levels required for LISA. A detailed description of the testbed and preliminary results will be presented.

Guzman, Felipe↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space: Progress

We describe progress toward developing a laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft at the few ppm level, with a capability of scaling to permit global CO2 measurements from orbit. Accurate measurements of the tropospheric CO2 mixing ratio from space are challenging due to the many potential error sources. These include possible interference from other trace gas species, the effects of temperature, clouds, aerosols & turbulence in the path, changes in surface reflectivity, and variability in dry air density caused by changes in atmospheric pressure, water vapor and topographic height. Some potential instrumental errors include frequency drifts in the transmitter, small transmission and sensitivity drifts in the instrument. High signal-to-noise ratios and measurement stability are needed for mixing ratio estimates at the few ppm level. We have been developing a laser sounder approach as a candidate for a future space mission. It utilizes multiple different laser transmitters to permit simultaneous measurement of CO2 and O2 extinction, and aerosol backscatter in the same measurement path. It directs the narrow co-aligned laser beams from the instrument's fiber lasers toward nadir, and measures the energy of the strong laser echoes reflected from the Earth's land and water surfaces. During the measurement its narrow linewidth lasers are rapidly tuned on- and off- selected CO2 line near 1572 nm and an O2 absorption line near 770 nm. The receiver measures the energies of the laser echoes from the surface and any clouds and aerosols in the path with photon counting detectors. Ratioing the on- to off-line echo pulse energies for each gas permits the column extinction and column densities of CO2 and O2 to be estimated simultaneously via the differential absorption lidar technique. For the on-line wavelengths, the side of the selected absorption lines are used, which due to pressure broadening, weights the measurements to the lower troposphere, where CO2 variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column abundance are made using an identical approach using an O2 line. The laser backscatter profiles from clouds and aerosols are measured with other lidar channels, which permits identifying measurements influenced by clouds and/or aerosol scattering in the path. For space use, our lidar would continuously measure at nadir in near polar circular orbit. Using dawn and dusk measurements made over the same region will make it possible to sample the diurnal variations in CO2 mixing ratios. A 1-m diameter telescope is used for the receiver for all wavelengths. When averaging over 50 seconds, our calculations show a SNR of approximately 1500 is achievable for each gas at each on- and off-line measurement. Measurements from such a mission can be used to generate monthly global maps of the lower tropospheric CO2 column abundance. Our calculations show global coverage with an accuracy of a few ppm with a spatial resolution of approximately 50,000 sq. km are achievable each month. We have demonstrated some key elements of the laser, detector and receiver approaches in the laboratory and with measurements over a 206 m horizontal path. These include stable measurements of CO2 line shapes in an absorption cell using a fiber laser amplifier seeded by a tunable diode laser, measurement of small amplitude changes at low optical signal levels with the PMT receiver, and comparison of the horizontal path measurements of CO2 against those from an in-situ instrument.

Abshire, J. B.↗

A microcomputer based frequency-domain processor for laser Doppler anemometry

A prototype multi-channel laser Doppler anemometry (LDA) processor was assembled using a wideband transient recorder and a microcomputer with an array processor for fast Fourier transform (FFT) computations. The prototype instrument was used to acquire, process, and record signals from a three-component wind tunnel LDA system subject to various conditions of noise and flow turbulence. The recorded data was used to evaluate the effectiveness of burst acceptance criteria, processing algorithms, and selection of processing parameters such as record length. The recorded signals were also used to obtain comparative estimates of signal-to-noise ratio between time-domain and frequency-domain signal detection schemes. These comparisons show that the FFT processing scheme allows accurate processing of signals for which the signal-to-noise ratio is 10 to 15 dB less than is practical using counter processors.

Horne, W. Clifton↗

A microcomputer based frequency-domain processor for laser Doppler anemometry

A prototype multi-channel laser Doppler anemometry (LDA) processor was assembled using a wideband transient recorder and a microcomputer with an array processor for fast Fourier transform (FFT) computations. The prototype instrument was used to acquire, process, and record signals from a three-component wind tunnel LDA system subject to various conditions of noise and flow turbulence. The recorded data was used to evaluate the effectiveness of burst acceptance criteria, processing algorithms, and selection of processing parameters such as record length. The recorded signals were also used to obtain comparative estimates of signal-to-noise ratio between time-domain and frequency-domain signal detection schemes. These comparisons show that the FFT processing scheme allows accurate processing of signals for which the signal-to-noise ratio is 10 to 15 dB less than is practical using counter processors.

Horne, W. Clifton↗

Effects of laser-annealing on fixed-frequency superconducting qubits

As superconducting quantum processors increase in complexity, techniques to overcome constraints on frequency crowding are needed. The recently developed method of laser-annealing provides an effective post-fabrication method to adjust the frequency of superconducting qubits. In this work, we present an automated laser-annealing apparatus based on conventional microscopy components and demonstrate preservation of highly coherent transmons. In addition, we perform noise spectroscopy to investigate the change in defect features, in particular, two-level system defects, after laser-annealing. Finally, we present a local heating model as well as demonstrate aging stability for laser-annealing on the wafer scale. Our work constitutes an important step toward both understanding the underlying physical mechanism and scaling up laser-annealing of superconducting qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗