Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Rare Earth Garnet Selective Emitter

Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional impurities, in the development of solid state laser crystals. Doping, dependent on the particular ion and crystal structure, may be as high as 100 at. % (complete substitution of yttrium ion with the rare earth ion). These materials have high melting points, 1940 C for YAG (Yttrium Aluminum Garnet), and low emissivity in the near infrared making them excellent candidates for a thin film selective emitter. As previously stated, the spectral emittance of a rare earth emitter is characterized by one or more well defined emission bands. Outside the emission band the emittance(absorptance) is much lower. Therefore, it is expected that emission outside the band for a thin film selective emitter will be dominated by the emitter substrate. For an efficient emitter (power in the emission band/total emitted power) the substrate must have low emittance, epsilon(sub S). This paper presents normal spectral emittance, epsilon(sub lambda), measurements of holmium(Ho) and erbium (Er) doped YAG thin film selective emitters at (1500 K), and compares those results with the theoretical spectral emittance.

Lowe, Roland A.↗

The DREAM Endstation at the Linac Coherent Light Source

Free-electron lasers (FEL), with their ultrashort pulses, ultrahigh intensities, and high repetition rates at short wavelength, have provided new approaches to Atomic and Molecular Optical Science. One such approach is following the birth of a photo electron to observe ion dynamics on an ultrafast timescale. Such an approach presents the opportunity to decipher the photon-initiated structural dynamics of an isolated atomic and molecular species. It is a fundamental step towards understanding single- and non-linear multi-photon processes and coherent electron dynamics in atoms and molecules, ultimately leading to coherent control following FEL research breakthroughs in pulse shaping and polarization control. A key aspect for exploring photoinduced quantum phenomena is visualizing the collective motion of electrons and nuclei in a single reaction process, as dynamics in atoms/ions proceed at femtosecond (10 –15 s) timescales while electronic dynamics take place in the attosecond timescale (10 –18 s). Here, we report on the design of a Dynamic Reaction Microscope (DREAM) endstation located at the second interaction point of the Time-Resolved Molecular and Optical (TMO) instrument at the Linac Coherent Light Source (LCLS) capable of following the photon–matter interactions by detecting ions and electrons in coincidence. The DREAM endstation takes advantage of the pulse properties and high repetition rate of LCLS-II to perform gas-phase soft X-ray experiments in a wide spectrum of scientific domains. With its design ability to detect multi-ions and electrons in coincidence while operating in step with the high repetition rate of LCLS-II, the DREAM endstation takes advantage of the inherent momentum conservation of reaction product ions with participating electrons to reconstruct the original X-ray photon–matter interactions. In this report, we outline in detail the design of the DREAM endstation and its functionality, with scientific opportunities enabled by this state-of-the-art instrument.

47 OTHER INSTRUMENTATION↗

Two-Color IRMPD Applied to Conformationally Complex Ions: Probing Cold Ion Structure and Hot Ion Unfolding

Two-color infrared multiphoton dissociation (2C-IRMPD) spectroscopy is a technique that mitigates spectral distortions due to nonlinear absorption that is inherent to one-color IRMPD. We use a 2C-IRMPD scheme that incorporates two independently tunable IR sources, providing considerable control over the internal energy content and type of spectrum obtained by varying the trap temperature, the time delays and fluences of the two infrared lasers, and whether the first or second laser wavelength is scanned. In this work, we describe the application of this variant of 2C-IRMPD to conformationally complex peptide ions. The 2C-IRMPD technique is used to record near-linear action spectra of both cations and anions with temperatures ranging from 10 to 300 K. In this work, we also determine the conditions under which it is possible to record IR spectra of single conformers in a conformational mixture. Furthermore, we demonstrate the capability of the technique to explore conformational unfolding by recording IR spectra with widely varying internal energy in the ion. The protonated peptide ions YGGFL (NH 3 + -Tyr-Gly-Gly-Phe-Leu, Leu-enkephalin) and YGPAA (NH 3 + -Tyr-Gly-Pro-Ala-Ala) are used as model systems for exploring the advantages and disadvantages of the method when applied to conformationally complex ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simplified model of a volumetric direct nuclear pumped He-3-Ar laser

A physical model for the volumetric nuclear pumped He-3-Ar laser is described and the source terms arising from the He-3(n, p)H-3 reaction as well as the rate equations are given. Steady state solutions are derived for the densities of the species vs the fraction of argon. The dominant pumping mechanism is found to be collisional radiative recombination of the argon atomic ions and subsequent cascading into the upper laser level. The reactions following recombination are described and an expression is derived for the difference in densities of the argon 3d and 4p levels. Comparison with experiments shows good agreement.

Harries, W. L.↗

Laser mass spectrometer

Development of time of flight mass spectrometer using laser powered vaporization source is discussed. Operation of equipment to measure thermal velocities of individual mass species is described. Illustration of test equipment installation and detailed line drawing of ion producing equipment are provided.

Lincoln, K. A.↗

A confocal laser-induced fluorescence diagnostic with an annular laser beam

Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.

47 OTHER INSTRUMENTATION↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic mix at gas-shell interface in inverted corona fusion targets

Gas-filled, laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. At the fill pressures under investigation, ejected particles from the shell can penetrate deeply into the gas before colliding, leading to significant mixing across the gas–shell interface. Here, we use kinetic-ion, fluid-electron hybrid particle-in-cell simulations to explore the nature of that mix. Simulations of the system demonstrate characteristics of a weakly collisional electrostatic shock, whereby a strong electric field accelerates shell ions into the rarefied gas and reflects upstream gas ions. This interpenetration is mediated by collisional processes: At higher initial gas pressure, fewer shell particles pass into the mix region and reach the hotspot. This effect is detectable through neutron yield scaling vs gas pressure. Predictions of neutron yield scaling show excellent agreement with experimental data recorded at the OMEGA laser facility, suggesting that 1D kinetic mechanisms are sufficient to capture the mix process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherence imaging spectroscopy at Wendelstein 7-X for impurity flow measurements

In the last decade, Coherence Imaging Spectroscopy (CIS) has shown distinctive results in measuring ion flow velocities in the edge of magnetically confined plasma devices. Its 2D spatially resolved measurement capabilities and its high optical throughput are ideal for investigating the impurity behavior in the complex 3D magnetic island topology edge of Wendelstein 7-X (W7-X). However, a highly precise and stable calibration method is required for a reliable diagnostic operation. A new level of precision and stability has been achieved for the two CIS systems installed at W7-X with the use of a new calibration source, a continuous tunable laser commercially available only since 2015. A specific prototype model was successfully adapted to the challenging requirements of W7-X, granting high accuracy (±0.01 pm) and flexibility (spectral range: 450–650 nm) in the wavelength calibration required for measuring low-Z impurity ion flow velocities. These features opened up new investigation possibilities on temperature stability and wavelength response of the CIS components, allowing to fully characterize and validate the W7-X systems. The CIS diagnostic was operational throughout the last W7-X experimental campaign. Measured velocities on the order of ~20–30 km/s were observed, corroborated by comparisons with measurements with Mach probes.

47 OTHER INSTRUMENTATION↗

Formation of ion damage tracks

A new model is proposed to explain both localized damage regions and preferential etching of damage tracks caused by the passage of energetic ions in insulators. The formation of each region of extended defects is initiated by the Auger decay of a vacancy produced in an inner electronic shell of an atom of the insulator by an incident ion. This decay produces an intense source of ionization within a small volume around the decaying atom, which causes decomposition of the material in a manner similar to that observed in pulsed laser irradiation. The resulting chemical or crystalline modification of the material is the latent track, which can be preferentially etched due to its changed structure.

Tombrello, T. A.↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Direct nuclear-pumped lasers using the He-3/n,p/H-3 reaction

A description is presented of experimental results concerning a specific class of direct nuclear-pumped lasers classified as 'volumetric nuclear lasers'. In the considered laser system a fissioning gas, He-3, is mixed with the lasing gas to form a homogeneous mixture, resulting in uniform volume excitation. In typical volumetric nuclear lasers a fast-burst reactor is used as a source of neutrons which penetrate a polyethylene moderator. Here the fast neutrons are thermalized. After thermalization, neutrons scatter into the laser cell. Nuclear reactions produce a proton of 0.56 MeV and a tritium ion of 0.19. These ions produce secondary electrons which pump the laser medium creating a population inversion. The results reported demonstrate direct nuclear pumping of He-3-Ar, Xe, Kr, and Cl with the considered system.

Deyoung, R. J.↗

Electron-Ion Temperature Relaxation in Warm Dense Hydrogen Observed With Picosecond Resolved X-Ray Scattering

Angularly resolved X-ray scattering measurements from fs-laser heated hydrogen have been used to determine the equilibration of electron and ion temperatures in the warm dense matter regime. The relaxation of rapidly heated cryogenic hydrogen is visualized using 5.5 keV X-ray pulses from the Linac Coherent Light (LCLS) source in a 1 Hz repetition rate pump-probe setting. We demonstrate that the electron-ion energy transfer is faster than quasi-classical Landau-Spitzer models that use ad hoc cutoffs in the Coulomb logarithm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrodynamic conditions in laser irradiated buried layer experiments

The calculation of open shell ionization level and radiative properties of materials in Non-Local Thermal Equilibrium (NLTE) is currently still a major challenge for any atomic model. The predictions of various NLTE atomic codes at these conditions still differ significantly. In recent years, a new buried layer platform was developed at the Lawrence Livermore National Laboratory and the Laboratory for Laser Energetics. This platform is used to measure ionization distribution and emission of open L-shell, mid-Z ions and open M-shell, high-Z ions at NLTE conditions that are relevant in many laser plasma applications. These experiments offer a unique chance for benchmarking the atomic models. In order to perform these experiments, a uniform well characterized plasma source is required. In this work, we present one-dimensional (1D) and two-dimensional simulations of the experimental platform. These simulations were used for both the design and the analysis of the experiments. The simulations demonstrate the different phases of hydrodynamic evolution of the target and identify the time windows in which uniform conditions can be achieved. A 1D expansion of the target was found to be adequate to describe the target's evolution for most of the experiment duration. The fast 1D simulations were compared with recent experimental results from the Omega laser facility. The sensitivity of the results to several modeling parameters such as the electron flux limiter and laser resonant absorption is reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Longitudinal Profile Measurement of Operational H⁻ Beam at the SNS Linac Using a Laser Comb

We demonstrate a novel technique to measure the longitudinal profile of an operational hydrogen ion (H⁻) beam in a non intrusive, real-time fashion. The measurement is conducted based on the photo-ionization of the ion beam with a phase modulated laser comb pico-second laser pulses with controllable temporal structure. The measurement technique has been applied to a 1-GeV, 1.4-MW H⁻ beam at the Spallation Neutron Source (SNS) high energy beam transport (HEBT). A stroboscopic photo-graph of H⁻ beamμbunch can be obtained by using a phase modulated laser comb. The entire measurement takes only 700 us.

Liu, Yun↗

Laser-Assisted Analysis of Aerosol Particles

Proposed instrument makes rapid mass-spectrometric analyses of individual particles in aerosols. Each particle vaporized and ionized by intense laser pulse, which creates ions of minimum complexity. Ability to analyze single aerosol particles continuously makes technique suitable for detection of toxic aerosol particles on real-time basis and for identification of their sources.

Sinha, M. P.↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗