Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Frequency stability and offset locking of a laser-diode-pumped Nd:YAG monolithic nonplanar ring oscillator

The frequency stability of laser-diode-pumped, monolithic Nd:YAG solid-state unidirectional nonplanar ring oscillators was studied by heterodyne measurements. CW single-axial- and transverse-mode power of 25 mW at 1064 nm was obtained at a slope efficiency of 19 percent. Two independent oscillators were offset-locked at 17 MHz with frequency fluctuations of less than + or - 40 kHz for periods of 8 min.

Kane, Thomas J.↗

NASA's Preparations for ESA's L3 Gravitational Wave Mission

Telescope Subsystem - Jeff Livas (GSFC): Demonstrate pathlength stability, straylight and manufacturability. Phase Measurement System - Bill Klipstein (JPL): Key measurement functions demonstrated. Incorporate full flight functionality. Laser Subsystem - Jordan Camp (GSFC): ECL master oscillator, phase noise of fiber power amplifier, demonstrate end-to-end performance in integrated system, lifetime. Micronewton Thrusters - John Ziemer (JPL): Propellant storage and distribution, system robustness, manufacturing yield, lifetime. Arm-locking Demonstration - Kirk McKenzie (JPL): Studying a demonstration of laser frequency stabilization with GRACE Follow-On. Torsion Pendulum - John Conklin (UF): Develop U.S. capability with GRS and torsion pendulum test bed. Multi-Axis Heterodyne Interferometry - Ira Thorpe (GSFC): Investigate test mass/optical bench interface. UV LEDs - John Conklin+ (UF): Flight qualify UV LEDs to replace mercury lamps in discharging system. Optical Bench - Guido Mueller (UF): Investigate alternate designs and fabrication processes to ease manufacturability. LISA researchers at JPL are leading the Laser Ranging Interferometer instrument on the GRACE Follow-On mission.

Midterm Assessment↗

Estimation of Frequency Noise in Semiconductor Lasers Due to Mechanical Thermal Noise

We evaluate mechanical thermal noise in semiconductor lasers, applying a methodology developed for fixed-spacer cavities for laser frequency stabilization. Our simple model determines an underlying fundamental limit for the frequency noise of free-running semiconductor laser, and provides a framework: where the noise may be potentially reduced with improved design.

Numata, Kenji↗

Laser heterodyne spectrometer for helioseismology

The technique of laser heterodyne spectroscopy has been applied to the measurement of solar oscillations. Coherent mixing of solar radiation with the output of a frequency-stabilized CO2 laser permits the measurement of fully resolved profiles of solar absorption lines with high spectral purity and excellent frequency stability. This technique has been used to measure OH pure rotation lines in the infrared solar spectrum. Power spectra of these line frequency measurements show the well-known 5-min oscillations as well as significant velocity power at shorter periods.

Glenar, D. A.↗

Tropospheric and stratospheric wind profiling with a direct detection Doppler lidar

The Space Physics Research Laboratory at the University of Michigan has been operating a direct detection, high resolution Doppler Lidar (HRDL) to measure winds in the boundary layer, free troposphere and lower stratosphere. A direct detection Doppler lidar measures the Doppler shift of the aerosol or Rayleigh backscattered signal, from which the wind velocity vector can be retrieved (Benedetti-Michelangeli et al, 1972, 1974; Chanin et al., 1989; Abreu et al., 1992). The system components are shown. The transmitting system is a Continuum NY-60 Nd:YAG laser frequency doubled to a wavelength of 532 nm. The laser is injection seeded for single line mode operation yielding a linewidth of 0.0045 cm(exp -1) (135 MHz) with excellent shot-to-shot frequency stability. The laser produces 60 mJ pulses and operates at a 50 Hz repetition rate for an effective output power of 3.0 W. A description of the University of Michigan's Doppler lidar is given with examples of wind profiles for the boundary layer, free troposphere, and for the lower stratosphere. The system provides a reliable method of remotely measuring the wind. The wind error is smallest in regions of high aerosols. The system also produces aerosol extinction profiles versus altitude which can be determined by the shape of the spectra. The system has been installed in a trailor so that measurements can be made for field campaigns. Winds and aerosol data are available immediately at the site for use in forecasting.

Abreu, Vincent J.↗

Frequency Swept Diode-pumped Single Frequency TM,Ho:YLiF Laser for spaceborne Doppler Lidar

Optical heterodyne experiments involving the photomixing of two single frequency, deode-pumped thulium holmium yttrium lithium flouride lasers are described. Operated in external frquency stabilization loops, the lasers exhibit 1MHz short term stability, and are photomixed and offset-locked at 140 MHz. Summation of sine wave modulation onto the PZT control voltage on one laser results in frequency swept operation over a continuous tuning range of 160 MHz.

Doppler Lidar Optical heterodyne experiments↗

Pressure effects on the frequency of continuous-wave optically pumped far-infrared lasers

The frequency of the 170.6-micron CW CH3OH optically pumped laser emission has been remeasured at different pressures without observing the pressure shift observed by Lawandy and Koepf (1980). The far-infrared frequency was synthesized with two stabilized CO2 lasers. No measurable pressure shift over the operating pressure range of the laser was observed, and the frequency was confirmed to be 1 757 526.3 MHz. However, competing lasing lines were found to produce spurious effects on the frequency. These effects may explain the apparent shifts.

Inguscio, M.↗

Arm Locking for the Laser Interferometer Space Antenna

The Laser Interferometer Space Antenna (LISA) mission is a planned gravitational wave detector consisting of three spacecraft in heliocentric orbit. Laser interferometry is used to measure distance fluctuations between test masses aboard each spacecraft to the picometer level over a 5 million kilometer separation. Laser frequency fluctuations must be suppressed in order to meet the measurement requirements. Arm-locking, a technique that uses the constellation of spacecraft as a frequency reference, is a proposed method for stabilizing the laser frequency. We consider the problem of arm-locking using classical optimal control theory and find that our designs satisfy the LISA requirements.

Maghami, P. G.↗

Energy measurement of electron beams by Compton scattering

A method has been proposed to utilize the well-known Compton scattering process as a tool to measure the centroid energy of a high energy electron beam at the 0.01% level. It is suggested to use the Compton scattering of an infrared laser off the electron beam, and then to measure the energy of the scattered gamma-rays very precisely using solid-state detectors. The technique proposed is applicable for electron beams with energies from 200 MeV to 16 GeV using presently available lasers. This technique was judged to be the most viable of all those proposed for beam energy measurements at the nearby Continuous Electron Beam Accelerator Facility (CEBAF). Plans for a prototype test of the technique are underway, where the main issues are the possible photon backgrounds associated with an electron accelerator and the electron and laser beam stabilities and diagnostics. The bulk of my ASEE summer research has been spent utilizing the expertise of the staff at the Aerospace Electronics Systems Division at LaRC to assist in the design of the test. Investigations were made regarding window and mirror transmission and radiation damage issues, remote movement of elements in ultra-high vacuum conditions, etc. The prototype test of the proposed laser backscattering method is planned for this December.

Keppel, Cynthia↗

Technology Advancement for Active Remote Sensing of Carbon Dioxide from Space Using the ASCENDS CarbonHawk Experiment Simulator: First Results

The ASCENDS CarbonHawk Experiment Simulator (ACES) is a newly developed lidar developed at NASA Langley Research Center and funded by NASA's Earth Science Technology Office (ESTO) Instrument Incubator Program (IIP) that seeks to advance technologies critical to measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The technology advancements targeted include: (1) increasing the power-aperture product to approach ASCENDS mission requirements by implementing multi-aperture telescopes and multiple co-aligned laser transmitters; (2) incorporating high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) developing and incorporating a high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration autonomous operation on Global Hawk aircraft, and (4) advancing algorithms for cloud and aerosol discrimination. The ACES instrument architecture is being developed for operation on high-altitude aircraft and will be directly scalable to meet the ASCENDS mission requirements. These technologies are critical towards developing not only spaceborne instruments but also their airborne simulators, with lower platform requirements for size, mass, and power, and with improved instrument performance for the ASCENDS mission. ACES transmits five laser beams: three from commercial EDFAs operating near 1.57 microns, and two from the Exelis oxygen (O2) Raman fiber laser amplifier system operating near 1.26 microns. The three EDFAs are capable of transmitting up to 10 watts average optical output power each and are seeded by compact, low noise, stable, narrow-linewidth laser sources stabilized with respect to a CO2 absorption line using a multi-pass gas absorption cell. The Integrated-Path Differential Absorption (IPDA) lidar approach is used at both wavelengths to independently measure the CO2 and O2 column number densities and retrieve the average column CO2 mixing ratio. The ACES receiver uses three fiber-coupled 17.8-cm diameter athermal telescopes. The transmitter assembly consists of five fiber-coupled laser collimators and an associated Risley prism pair for each laser to co-align the outgoing laser beams and to align them with the telescope field of view. The backscattered return signals collected by the three telescopes are combined in a fiber bundle and sent to a single low noise detector. The detector/TIA development has improved the existing detector subsystem by increasing its bandwidth to 4.7 MHz from 500 kHz and increasing the duration of autonomous, service-free operation periods from 4 hours to >24 hours. The new detector subsystem enables the utilization of higher laser modulation rates, which provides greater flexibility for implementing advanced thin-cloud discrimination algorithms as well as improving range-determination resolution and error reduction. The cloud/aerosol discrimination algorithm development by Langley and Exelis features a new suite of algorithms for the minimization/elimination of bias errors in the return signal induced by the presence of intervening thin clouds. Multiple laser modulation schemes are being tested in an effort to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. Full instrument development concluded in the spring of 2014. After ground range tests of the instrument, ACES successfully completed six test flights on the Langley Hu-25 aircraft in July, 2014, and recorded data at multiple altitudes over land and ocean surfaces with and without intervening clouds. Preliminary results from these test flights will be presented in this paper.

Obland, Michael D.↗

Research in the aerospace physical sciences

Research efforts are reported in various areas including dynamics of thin films, polymer chemistry, mechanical and chemical properties of materials, radar system engineering, stabilization of lasers, and radiation damage of organic crystals. Brief summaries of research accomplished and literature citations are included.

Whitehurst, R. N.↗

Solar cell spectral response characterization

The absolute spectral response of solar cells is reported in the 400-1000-nm spectral region. Measurements were performed using two different types of monochromatic sources: amplitude-stabilized CW laser lines and interference filters with an incandescent lamp. Both types of calibration procedures use electrical substitution radiometry as the basis of traceability to absolute SI units. The accuracy of the calibration is shown to be limited by the nonideal characteristics of the solar cells themselves, specifically spatial nonuniformities and nonlinearities induced by high light levels.

Zalewski, E. F.↗

Diode laser 87Rb optical pumping in an evacuated wall-coated cell

The evacuated wall coated sealed cell coupled with diode laser optical pumping offers a number of attractive potential advantages for use in Rb or Cs atomic frequency standards. An investigation of systematic effects is required to explore possible limitations of the technique. The use of diode laser optical pumping of 87 Rb in an evacuated wall coated sealed cell is presented. Experimental results/discussion to be presented include the signal strength and line broadening of the 0 - 0 hyperfine resonance as a function of light intensity for the D1 optical transitions (F - F prime) - (2 1 prime) and (2 - 2 prime), shift of the 0 - 0 hyperfine frequency as a function of laser intensity and de-tuning from optical resonance, and diode laser frequency stabilization techniques.

Lee, W. K.↗

Frequency stability of a tunable diode laser mounted in a compact Stirling cycle cooler

A tunable diode laser (TDL) has been operated with a compact lightweight closed-cycle Stirling cooler. The laser linewidth has been measured near 80 K and found to be about half of that when using more massive closed-cycle coolers. Novel applications include balloon-borne and aircraft-adapted instruments, where size, weight, and power requirements place stringent demands on necessary TDL cooling systems.

Durso, Santo S.↗

Faraday anomalous dispersion optical tuners

Common methods for frequency stabilizing diode lasers systems employ gratings, etalons, optical electric double feedback, atomic resonance, and a Faraday cell with low magnetic field. Our method, the Faraday Anomalous Dispersion Optical Transmitter (FADOT) laser locking, is much simpler than other schemes. The FADOT uses commercial laser diodes with no antireflection coatings, an atomic Faraday cell with a single polarizer, and an output coupler to form a compound cavity. This method is vibration insensitive, thermal expansion effects are minimal, and the system has a frequency pull in range of 443.2 GHz (9A). Our technique is based on the Faraday anomalous dispersion optical filter. This method has potential applications in optical communication, remote sensing, and pumping laser excited optical filters. We present the first theoretical model for the FADOT and compare the calculations to our experimental results.

Wanninger, P.↗

High Resolution Doppler Lidar

This Grant supported the development of an incoherent lidar system to measure winds and aerosols in the lower atmosphere. During this period the following activities occurred: (1) an active feedback system was developed to improve the laser frequency stability; (2) a detailed forward model of the instrument was developed to take into account many subtle effects, such as detector non-linearity; (3) a non-linear least squares inversion method was developed to recover the Doppler shift and aerosol backscatter without requiring assumptions about the molecular component of the signal; (4) a study was done of the effects of systematic errors due to multiple etalon misalignment. It was discovered that even for small offsets and high aerosol loadings, the wind determination can be biased by as much as 1 m/s. The forward model and inversion process were modified to account for this effect; and (5) the lidar measurements were validated using rawinsonde balloon measurements. The measurements were found to be in agreement within 1-2 m/s.

Source record↗