Exploring leakage in dielectric films via automated experiments in scanning probe microscopy

Here electronic conduction pathways in dielectric thin films are explored using automated experiments in scanning probe microscopy (SPM). In this study, we use large field of view scanning to identify the position of localized conductive spots and develop an SPM workflow to probe their dynamic behavior at higher spatial resolution as a function of time, voltage, and scanning process in an automated fashion. Using this approach, we observe the variable behaviors of the conductive spots in a 20-nm-thick ferroelectric Hf 0.54 Zr 0.48 O 2 film, where conductive spots disappear and reappear during continuous scanning. There are also fresh conductive spots that develop during scanning. The automated workflow is universal and can be integrated into a wide range of microscopy techniques, including SPM, electron microscopy, optical microscopy, and chemical imaging.

36 MATERIALS SCIENCE↗

GaN-on-GaN p-i-n diodes with avalanche capability enabled by eliminating surface leakage with hydrogen plasma treatment

Traditional mesa terminations require precise angle design to reduce the electric field at the edge and surface treatment to reduce etch damage. Otherwise, the device usually suffers a premature breakdown. This work proposes the use of easy-to-implement hydrogen plasma treatment to solve the premature breakdown caused by mesa and demonstrates the avalanche capability in GaN-on-GaN p-i-n diodes. The breakdown electric field when the avalanche occurred was ∼2.3 MV/cm at room temperature for a GaN drift layer with a doping concentration of ∼7 × 1015 cm−3, which is consistent with the theoretical value. The temperature coefficient of the avalanche breakdown voltage of the devices was 4.64–4.85 × 10−4 K−1. This work shows a simple and effective approach to achieve avalanche capability in vertical GaN power devices, which can serve as an important reference for the future development of efficient and robust GaN power electronics.

Fu, Kai (ORCID:0000000294057512)↗

Electrochromic shift supports the membrane destabilization model of Tat-mediated transport and shows ion leakage during Sec transport

Significance Due to the transient nature of the active Tat complex, much of the knowledge available has been hard won. Electric-field-indicating absorbance transients allow investigation of transmembrane ion movement using native electric potential in thylakoids while circumventing challenges of reconstitution. Electrical behavior of transiently and/or constitutively assembled complexes suggests that Sec translocation occurs through a barrel-stave-type proteinaceous pore, while Tat translocation likely occurs through a toroidal pore. This would be the first instance of toroidal pores being exploited by a general protein translocation system. Our electrochemical analysis offers insight into how protein transport might be linked to light stimulation. Localized membrane destabilization presents a rational link between the proton motive force, membrane thinning, and Tat-mediated transport of substrates critical to photosynthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

SSA Monte Carlo and Master Equation Modeling of Neutron Leakage Distributions

Strongly stochastic neutron populations in highly subcritical multiplying media containing weak spontaneous fission sources are unique indicators of the presence of SNM. For instance, in neutron multiplicity counting, an extended tail in the count number probability distribution is observed that is a characteristic of and sensitive to the amount of SNM present. Theoretical modeling and efficient computation of stochastic neutron distributions are complementary to experimental measurements and moreover shed light on the fundamental interactions and transport processes that underlie nuclear signatures. Modeling approaches that are intermediate between gross-system level models and high-fidelity but computationally demanding Monte Carlo simulations are of particular interest in this regard. Furthermore we present three advances on existing work in point kinetic or lumped geometry: (i) implementation of the Stochastic Simulation Algorithm (SSA), a system state-updating Monte Carlo method that is more e cient than single-event Monte Carlo in lumped geometries, (ii) application of the backward Master equation to obtain time-gated count moments, and (iii) reconstructing the count number distribution from the deterministically computed moments using a generalized Laguerre polynomial expansion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimation of High-Altitude Electromagnetic Pulse Signal Leakage into Power Generation Facilities: Simulations and Measurements

The coupling of early-time high-altitude electromagnetic pulse signals into a power generation facility was investigated. This study encompasses both electromagnetic simulation and on-site experimental efforts that are relevant to shielding effectiveness estimation with a passive technique. As an initial step in understanding the attenuation models involved, simulations were carried out as a function of frequency, building properties, and signal incidence angle. Testing was then performed at the US Department of Energy’s Oak Ridge National Laboratory campus to identify the equipment needed for signal collection and to fine-tune the experimental procedure. Finally, as an application of the models and methods presented, measurements were conducted at a power generation plant to derive the field transfer functions and coupled high-altitude electromagnetic pulse waveforms for various locations within the facility.

42 ENGINEERING↗