Search NASA⌕ Search

SEARCH · Search NASA

Results for “levelized cost of storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Development of a differentially balanced magnetic bearing and control system for use with a flywheel energy storage system

The purpose of a magnetically suspended flywheel energy storage system for electric utility load leveling is to provide a means to store energy during times when energy is inexpensive to produce and then return it to the customer during times of peak power demand when generated energy is most expensive. The design of a 20 kWh flywheel energy storage system for electric utility load leveling applications involves the successful integration of a number of advanced technologies so as to minimize the size and cost of the system without affecting its efficiency and reliability. The flywheel energy storage system uses a carbon epoxy flywheel, two specially designed low loss magnetic bearings, a high efficiency motor generator, and a 60 cycle AC power converter all integrated through a microprocessor controller. The basic design is discussed of each of the components that is used in the energy storage design.

Higgins, Mark A.↗

Local Power: Comparing County-Level Renewable Energy Potential to Consumption Using the SLOPE Platform

Wide-scale deployment of renewable energy technologies has the potential to significantly reduce greenhouse gas emissions and mitigate the effects of climate change. Many communities have ambitious clean energy goals with targets for locally generated renewable energy. To inform state and local clean energy planning, analysts from the Joint Institute for Strategic Energy Analysis (JISEA) and National Renewable Energy Laboratory (NREL) used data from NREL's State and Local Planning for Energy (SLOPE) platform to compare annual technical generation potential of renewable energy technologies to modeled electricity consumption in every county of the contiguous United States. Annual costs were calculated to produce a 20% share of electricity consumed annually from each technology to examine localized cost effectiveness of a diversified mix of generation sources. For example, combining distributed and utility-scale wind and solar generation can offset the need for storage and nonintermittent fossil resources to achieve high deployment of renewables. This county-level analysis provides insight into where localized renewable energy generation could cost-effectively match annual electricity consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of the economics of photovoltaic-diesel-battery energy systems for remote applications

Computer simulations were conducted to analyze the performance and operating cost of a photovoltaic energy source combined with a diesel generator system and battery storage. The simulations were based on the load demand profiles used for the design of an all photovoltaic energy system installed in the remote Papago Indian Village of Schuchuli, Arizona. Twenty year simulations were run using solar insolation data from Phoenix SOLMET tapes. Total energy produced, energy consumed, operation and maintenance costs were calculated. The life cycle and levelized energy costs were determined for a variety of system configurations (i.e., varying amounts of photovoltaic array and battery storage).

Brainard, W. A.↗

Trade Study: Storing NASA HDF5/netCDF-4 Data in the Amazon Cloud and Retrieving Data Via Hyrax Server Data Server

This study explored three candidate architectures with different types of objects and access paths for serving NASA Earth Science HDF5 data via Hyrax running on Amazon Web Services (AWS). We studied the cost and performance for each architecture using several representative Use-Cases. The objectives of the study were: Conduct a trade study to identify one or more high performance integrated solutions for storing and retrieving NASA HDF5 and netCDF4 data in a cloud (web object store) environment. The target environment is Amazon Web Services (AWS) Simple Storage Service (S3). Conduct needed level of software development to properly evaluate solutions in the trade study and to obtain required benchmarking metrics for input into government decision of potential follow-on prototyping. Develop a cloud cost model for the preferred data storage solution (or solutions) that accounts for different granulation and aggregation schemes as well as cost and performance trades.We will describe the three architectures and the use cases along with performance results and recommendations for further work.

AWS cost↗

Optimization models for integrated biorefinery operations

Variations of physical and chemical characteristics of biomass lead to an uneven flow of biomass in a biorefinery, which reduces equipment utilization and increases operational costs. Uncertainty of biomass supply and high processing costs increase the risk of investing in the US’s cellulosic biofuel industry. We propose a stochastic programming model to streamline processes within a biorefinery. A chance constraint models system’s reliability requirement that the reactor is operating at a high utilization rate given uncertain biomass moisture content, particle size distribution, and equipment failure. The model identifies operating conditions of equipment and inventory level to maintain a continuous flow of biomass to the reactor. Furthermore, the sample average approximation method approximates the chance constraint and a bisection search-based heuristic solves this approximation. A case study is developed using real-life data collected at Idaho National Laboratory’s biomass processing facility. An extensive computational analysis indicates that sequencing of biomass bales based on moisture level, increasing storage capacity, and managing particle size distribution, increases utilization of the reactor and reduces operational costs.

09 BIOMASS FUELS↗

Task 28: Web Accessible APIs in the Cloud Trade Study

This study explored three candidate architectures for serving NASA Earth Science Hierarchical Data Format Version 5 (HDF5) data via Hyrax running on Amazon Web Services (AWS). We studied the cost and performance for each architecture using several representative Use-Cases. The objectives of the project are: Conduct a trade study to identify one or more high performance integrated solutions for storing and retrieving NASA HDF5 and Network Common Data Format Version 4 (netCDF4) data in a cloud (web object store) environment. The target environment is Amazon Web Services (AWS) Simple Storage Service (S3).Conduct needed level of software development to properly evaluate solutions in the trade study and to obtain required benchmarking metrics for input into government decision of potential follow-on prototyping. Develop a cloud cost model for the preferred data storage solution (or solutions) that accounts for different granulation and aggregation schemes as well as cost and performance trades.

cost model↗

Assessing the Performance and Impact of PV Technologies on Storage in Hybrid Renewable Systems

Traditional monofacial photovoltaic (mPV) systems are commonly adopted and well-documented because of their lower upfront costs in comparison to bifacial photovoltaic (bPV) systems. This study investigates how PV technologies impact energy storage in grid-scale hybrid renewable systems, focusing on optimizing and assessing the performance of mPV and bPV technologies integrated with pumped storage hydropower. Using Ludington City, Michigan as a case study and analyzing real-world data such as solar irradiance, ambient temperature, and utility-scale load profiles, the research highlights the operational and economic benefits of bPV systems. The results reveal that bPV systems can pump approximately 10.38% more water annually to the upper reservoir while achieving a lower levelized cost of energy ($0.0578/kWh for bPV vs. $0.0672/kWh for mPV). This study underscores the outstanding potential of bPV systems in enhancing energy storage and management strategies, contributing to a more sustainable and resilient renewable energy future.

13 HYDRO ENERGY↗

Predictive-Maintenance Practices: For Operational Safety of Battery Energy Storage Systems

Changes in the Demand Profile and a growing role for renewable and distributed generation are leading to rapid evolution in the electric grid. These changes are beginning to considerably strain the transmission and distribution infrastructure. Utilities are increasingly recognizing that the integration of energy storage in the grid infrastructure will help manage intermittency and improve grid reliability. This recognition, coupled with the proliferation of state-level renewable portfolio standards and rapidly declining lithium-ion (Li-ion) battery costs, has led to a surge in the deployment of battery energy storage systems (BESSs). Additionally, although BESSs represented less than 1% of grid-scale energy storage in the United States in 2019, they are the preferred technology to meet growing demand because they are modular, scalable, and easy to deploy across diverse use cases and geographic locations.

25 ENERGY STORAGE↗

Reinforced AEM Separators Based on Triblock Copolymers for Electrode-decoupled RFBs

Washington University in St. Louis (WUSTL), in collaboration with The University of Texas at San Antonio (UTSA) and Giner Inc. developed highly selective anion exchange membranes (AEMs) and a novel electrode-decoupled redox flow battery (RFB) for grid scale energy storage as part of the ARPA-E IONICS program (with connections to the DAYS program in the later part of the project). RFBs exhibit the crucial characteristic of system-level decoupled scaling of energy and power which makes them cost effective for the multi-GWh scales envisioned for grid-scale energy storage solutions. This has led to extensive (and deserved) research interest and attention. This project aimed to enhance the design space available for redox-flow batteries (RFBs) by enabling the long-term separation of disparate cationic (elemental) actives using a highly selective membrane separator, while concurrently permitting the transport of anions to balance charge. The approach proposed was to design and develop a highly selective anion-exchange membrane (AEM), which would in turn permit the design and development of electrode-decoupled RFBs. Pairs of (different element) cationic species with redox reactions exhibiting a large difference in their standard electrode potentials were identified to develop high voltage, high power RFBs while disrupting the existing paradigm of using a single element which can ionize to more than two soluble oxidation states (e.g.: Vanadium).

25 ENERGY STORAGE↗

Comparative Investigation of System-Level Optimized Power Conversion System Architectures to Reduce LCOE for Large-Scale PV-Plus-Storage Farms

PV-plus-storage (PVS) has become a prevalent configuration for newly commissioned large-scale solar projects. However, the optimal power conversion system (PCS) architecture has not been investigated yet. This paper first validates the limited impact of inverter cost on LCOE and then explores a system-level optimized PCS architecture with extended LCOE reduction to proliferate large-scale dispatchable solar energy. Two state-of-the-art architectures including central inverters (CI), traditional 480/600 V string inverters (SI) are compared with newly proposed medium voltage string inverters (MVSI) and multiport DC transformer (MDCT). With verified layouts and single line diagrams (SLDs) of 20 MW PVS plants, the losses and costs breakdown of different architectures are extracted and the PCS related LCOEs are derived. In this analysis, all electrical bill of materials (EBOS) elements, inverters, battery storage and its associated components, are included, whose losses and costs are obtained from markets, manufacturers, and literature. Besides, the sensitivities of PCS-related LCOEs to Inverter-Loading-Ratio (ILR) are also investigated. Here, the results show that compared with CI and SI with 1.5 kV PV, 4 kV MVSI and 34 kV MDCT present an extended LCOE reduction across all ILR from 1.0 to 3.0, making them economically favorable candidates for PVS farms.

14 SOLAR ENERGY↗

Getting brighter: Impacts of improved day-ahead solar forecasts in high-solar, high-storage electricity systems

This paper analyzes the impacts of improved day-ahead solar forecasts on costs and dispatch in the solar-rich Southeast U.S. It uses an optimized high-solar, high-storage resource portfolio in which solar generation capacity accounts for 45 % of total installed capacity (34 %–36 % of generation) and energy storage capacity (43 GW) is equivalent to 33 % of peak demand. In a base scenario, improved day-ahead solar forecasts reduce production costs by $\$87$ million per year ($\$0.13$ per MWh load, $2023$$). This level of savings is within the range or lower than earlier studies of solar forecast improvements at lower levels of solar generation (<25 % of total generation). In this study, solar expansion was accompanied by two important sources of flexibility for managing solar forecast error: energy storage and day-ahead solar curtailment. Furthermore, the analysis finds that regional coordination complements day-ahead solar forecast improvements while natural gas commitment flexibility is a substitute for forecast improvements, as the improved solar forecast leads to sub-optimal commitment of thermal units. Day-ahead solar forecast improvements reduce reserves required to manage forecast error by 30 %. Fewer reserves to manage large, infrequent solar forecast errors could be an important benefit of improved solar forecasts.

14 SOLAR ENERGY↗

On the role of Battery Energy Storage Systems in the day-ahead Contingency-Constrained Unit Commitment problem under renewable penetration

The integration of variable Renewable Energy Sources (vRES) to alleviate greenhouse gas emissions has introduced significant challenges for power systems operations. These challenges include high levels of uncertainty due to the intermittence associated with vRES and therefore impose the need to devise a reliable and cost-effective day-ahead unit commitment and power and reserves scheduling for real-time operations. Also, this increasing penetration of vRES requires higher ramping capabilities from units originally designed for other purposes (e.g., base-load generation), which might be exacerbated during contingency states. Hence, in this work, we propose a methodology to address the day-ahead Contingency-Constrained Unit Commitment (CCUC) problem that leverages the participation of Battery Energy Storage Systems (BESSs) to address load-following and post-contingency management, therefore alleviating the ramping burden on conventional thermal generators. To do so, we formulate a three-level optimization problem that represents the decision-making process of obtaining the least-cost commitment, generation and reserves scheduling, while restricting the Conditional Value-at-Risk (CVaR) of the system imbalance at real-time operations to user-defined tolerance levels. In addition, we devise a computationally efficient solution approach for the proposed problem based on the Column-and Constraint Generation (CCG) algorithmic framework. Two numerical experiments are conducted to empirically illustrate the benefits of the proposed methodology. Key results indicate a reduction in real-time ramping needs and a better usage of the system resources, with a reduction in the overall system commitment levels and reserve scheduling costs when compared to a benchmark case in which storage is not available.

Moreira, Alexandre↗

Minnesota Solar Pathways: Illuminating Pathways to 10% Solar (Final Technical Report)

The Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, was a three-year project designed to explore least-risk, best-value strategies for meeting the State of Minnesota’s solar goals. As part of this aim, the Pathways Team modeled renewable generation costs, examined ways to streamline interconnection, and evaluated technologies that can increase solar hosting capacity on the distribution grid. Midway through the project period, the Pathways Team expanded the scope of study using the same modeling framework from the Minnesota Solar Potential Analysis to estimate and compare generation costs for high renewables penetration scenarios across the Midcontinent Independent System Operator (MISO) region. The analysis concludes that it can be cheaper to overbuild solar + wind and curtail surplus than to store all generation. In addition, the analysis of individual MISO subregions compared with the whole region highlights the opportunities of enabling market potential compared with impact of ongoing transmission constraints. Beyond the analysis of future scenarios, the partnerships initiated and supported through this project underscored the ongoing need for work with stakeholders to address key issues, particularly around siting, and leverage symbiotic strategies to meet state goals.

14 SOLAR ENERGY↗

Supply of reactants for Redox bulk energy storage systems

World resources, reserves, production, and costs of reactant materials, iron, chromium, titanium and bromine for proposed redox cell bulk energy storage systems are reviewed. Supplying required materials for multimegawatt hour systems appears to be feasible even at current production levels. Iron and chromium ores are the most abundant and lowest cost of four reactants. Chromium is not a domestic reserve, but redox system installations would represent a small fraction of U.S. imports. Vast quantities of bromine are available, but present production is low and therefore cost is high. Titanium is currently available at reasonable cost, with ample reserves available for the next fifty years.

Gahn, R. F.↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

The 2020 photovoltaic technologies roadmap

Over the past decade, the global cumulative installed photovoltaic (PV) capacity has grown exponentially, reaching 591 GW in 2019. Rapid progress was driven in large part by improvements in solar cell and module efficiencies, reduction in manufacturing costs and the realization of levelized costs of electricity that are now generally less than other energy sources and approaching similar costs with storage included. Given this success, it is a particularly fitting time to assess the state of the photovoltaics field and the technology milestones that must be achieved to maximize future impact and forward momentum. This roadmap outlines the critical areas of development in all of the major PV conversion technologies, advances needed to enable terawatt-scale PV installation, and cross-cutting topics on reliability, characterization, and applications. Each perspective provides a status update, summarizes the limiting immediate and long-term technical challenges and highlights breakthroughs that are needed to address them. In total, this roadmap is intended to guide researchers, funding agencies and industry in identifying the areas of development that will have the most impact on PV technology in the upcoming years.

14 SOLAR ENERGY↗

A Reliable, Cost-Effective Transformerless Medium-Voltage Inverter for Grid Integration of Combined Solar and Energy Storage

The goal of this project is to utilize an innovative holistic power electronic inverter design approach, which can leverage best-in-class silicon carbide (SiC) power modules, novel multi-level power electronic circuits, high frequency transformers, switching sequence based control and co-designed electro-thermal management methods, to realize a 300 kW transformerless medium-voltage (MV) inverter system. The system cost of the inverter is considered as a primary design objective alongside high power density, efficiency, low electromagnetic interference (EMI) and long lifespan. This design-oriented research activity, especially the proposed multi-objective optimization approach, will have broad impacts in holistic power electronic system design methods and in technologies that can be commercialized into a wide variety of wide bandgap power electronic applications.

14 SOLAR ENERGY↗