Search NASA⌕ Search

SEARCH · Search NASA

Results for “light penetration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

148 records · Page 9

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adoption of Plug-in Electric Vehicles: Local Fuel Use and Greenhouse Gas Emissions Reductions Across the U.S.

The dependence on gasoline-powered light-duty automobiles has made U.S. households vulnerable to the burden of fuel costs. Tailpipe emissions from these vehicles constitute 58% of greenhouse gas (GHG) emissions in the U.S., which are damaging to the environment (EPA, 2023). The adoption of plug-in electric vehicles (PEVs) has been shown to effectively reduce fuel costs and GHG emissions. However, local effects on these benefits are not well understood by American consumers, potentially limiting adoption and therefore the realization of PEV benefits at scale (MacInnis & Krosnick, 2020; EY Americas, 2023). To fill this research gap, this study estimates the fuel cost savings and GHG emission reductions at the state and ZIP code levels by considering local fuel prices, vehicle class preference, average vehicle model year, fuel efficiencies, and driving intensities. The study's findings reveal that the adoption of PEVs can yield substantial benefits in terms of fuel cost savings and GHG emission reductions nationwide. Specifically, driving a battery electric vehicle (BEV) is estimated to result in annual savings of up to $\$2,200$, while driving a plug-in hybrid electric vehicle (PHEV) can lead to savings up to $\$1,500$, when compared to an internal combustion engine vehicle (ICEV) of equivalent size. Moreover, using population-weighted averages by ZIP code, BEVs and PHEVs show the potential to save 400 and 200 grams of carbon dioxide equivalent per mile, respectively, compared to a representative ICEV of the same class. The magnitude of fuel cost savings and emissions reduction vary by region due to various factors. Generally, regions with high gasoline prices, low electricity prices, preferences for larger vehicles, and high driving intensities tend to see relatively large fuel savings. The emissions reductions are more pronounced in areas with clean grids where consumer preferences lie with large vehicles. This regional variability underscores the importance of considering local contextual factors when assessing the potential benefits of PEV adoption. In more than 99% of U.S. ZIP codes, PEVs result in overall savings in fuel use (and subsequent costs) and GHG emissions. While not a central focus of this analysis, reductions in GHG tailpipe emissions from PEV adoption would also come with reductions in criteria pollutant emissions, contributing to improved local air quality depending on the PEV penetration, population density, and electricity generation infrastructure in the locality.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗