Search NASA⌕ Search

SEARCH · Search NASA

Results for “light shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Long, accurate time series measurements of radial velocities of solar-type stars

We have been measuring changes in the radial velocities (RV's) of solar-type stars to search for gravitational perturbations by planets. We transmit violet starlight through a Fabry-Perot etalon interferometer and sense changes in Doppler shift from changes in the fluxes of light on the slopes of stellar absorption lines. Our data now span 6 years. Our observations of the Sun showed earlier that both our technique and the profiles of solar photospheric violet absorption lines can be stable enough to reveal planetary perturbations. We now carry this validation to the spectra of other near-solar-type to reveal planetary perturbations. We now carry this validation to the spectra of other near-solar-type stars. Annual averages of our RV's of sigma Draconis and beta Virginis are stable to plus or minus 6 m/s. The slope of our five-year series of RV's of xi Bootis A is consistent with the star's well-determined visual astrometric orbit about xi Bootis B. The Fabry-Perot technique of Doppler shift measurement is fully capable of detecting perturbations due to planets with masses and orbits similar to those of Jupiter

Mcmillan, R. S.↗

Fatigue in U.S. Astronauts Onboard the International Space Station: Environmental Factors, Operational Impacts, and Implementation of Countermeasures

Since 2000, US astronauts have been supporting missions up to a six month duration on the International Space Station (ISS). Crewmembers have experienced fatigue for reasons similar to military deployments. Astronauts experience psychological stressors such as heavy workloads, extended duty periods, circadian misalignment, inadequate/ineffective sleep, and loss of the environmental cues of a gravity environment. Complicating the psychological stressors are environmental factors; distracting background noise, unexpected and variable mission schedules, unfavorable thermal control, elevated CO2 levels, and an unusual sleep environment with schedules that impinge on pre‐sleep periods. Physiological contributors to poor sleep and fatigue include a cephalad fluid shift and back pain. Restful sleep is further challenged due to a lack of gravity‐related proprioceptive cues and need for restraints. The term "space fog" has been used by astronauts to describe a phenomenon of forgetfulness, slowed reaction time and transient confusion while trying to complete tasks. There is a distinct temporal correlation with arrival on the Space Station and the onset of slowed cognitive skills and a spontaneous resolution that may take up to 6 weeks. The Genesis of this phenomenon may be chronic fatigue secondary to transitioning from a planar environment to a 360deg microgravity perspective. Recently, countermeasures to improve sleep duration and quality in astronauts on the ISS have been instituted with moderate degrees of success as measured by self‐reaction time (psychomotor vigilance task testing), actigraphy, and subjective reports. Judicious use of stimulants and hypnotics, light therapy, controlled sleep periods and sleep shifting and reducing ambient CO2 levels are a few of the most promising countermeasures being used in space to improve sleep and reduce fatigue.

Scheuring, R. A.↗

Dose-response relationships for resetting of human circadian clock by light

Since the first report in unicells, studies across diverse species have demonstrated that light is a powerful synchronizer which resets, in an intensity-dependent manner, endogenous circadian pacemakers. Although it is recognized that bright light (approximately 7,000 to 13,000 lux) is an effective circadian synchronizer in humans, it is widely believed that the human circadian pacemaker is insensitive to ordinary indoor illumination (approximately 50-300 lux). It has been proposed that the relationship between the resetting effect of light and its intensity follows a compressive nonlinear function, such that exposure to lower illuminances still exerts a robust effect. We therefore undertook a series of experiments which support this hypothesis and report here that light of even relatively low intensity (approximately 180 lux) significantly phase-shifts the human circadian pacemaker. Our results clearly demonstrate that humans are much more sensitive to light than initially suspected and support the conclusion that they are not qualitatively different from other mammals in their mechanism of circadian entrainment.

NASA Discipline Regulatory Physiology↗

Equal path, phase shifting, sample point interferometer for monitoring the configuration of surfaces

A system for monitoring the configuration of a surface (e.g., a segmented parabolic surface) using orthogonally placed retroreflectors at sets of points 1, 2, and 3 dispersed throughout the surface with a stationary halfwave plate (HWP) in the front of the one retroreflector at a corner point 3 and a rotating halfwave plate (RHWP) over a source of linearly polarized coherent light, thereby causing the direction of linear polarization to continuously rotate through 360 deg and causing light returned by the retroreflector at point 3 to be continuously phase shifted through 360 deg relative to light returned by retroreflectors at points 1 and 2. The returned light from each set of points 1, 2, and 3 is focused onto a bed-of-nails (BON) phase grating diagonally oriented with respect to the orthogonal orientation of the incident beams from retroreflectors 1, 2, and 3, thereby causing overlap in the light from points 1 and 3 to produce interferometric signals 1,3 and 2,3. Any change in phase of the interferometric signals 1,3 and 2,3 indicates both the magnitude and direction of any change in the position of the retroreflector at point 3 relative to retroreflectors at points 1 and 2.

Manhart, Paul K.↗

Photochromism of dihydroquinolines

Reversible photochromic reactions, in which absorption spectrum of chemical compound may be shifted by application of visible or ultraviolet light, and then returned to original state by heating, are observed for certain members of 1,2-dihydroquinoline family. Structural formulas for colorless and colored states are given.

Becker, R. S.↗

Laser Doppler velocity simulator

A method and apparatus for inducing a Doppler frequency shift in a reference beam laser velocimeter light beam to simulate target velocity are described. The light beam is passed through a rotating refractive transparent block positioned between two reference points along the beam which results in a continuous change in the light beam optical path length between the reference points according to a known function. The velocity indicated by the laser velocimeter is compared to the known simulated velocity function for velocimeter testing and calibration.

Franke, J. M.↗

Studies of the ultraviolet spectra of astronomical sources

An intensive program of observations of the Comet Halley during the week of the Vega 2 and Giotto encounters was carried out by the International Ultraviolet Explorer (IUE) satellite observatory. The IUE Fine Error Sensor, normally used for target acquisition and tracking, was used in a photometer mode to provide nealy continuous light curves over an 8 hour observing shift, a unique capability relative to ground-bases observers. The ultraviolet data can be used to derive an estimate of the total gas production rate even though the models generally used for this purpose assume a steady-state gas production which is clearly not the case for Halley. Additionally, the IUE data provide column abundances of carbon, oxygen, sulfur, OH, CO, CS, C2, and CO2 to compare with the in-situ measurements of these species by Vega 2 and Giotto.

Source record↗

VUV-visible measurements on different samples of amorphous carbon

Among various candidate materials for interstellar dust, amorphous carbon (AC) is playing an increasingly important role (Greenstein, 1981; Hecht et al., 1984; Jura, 1983, 1986). Furthermore, recent in situ measurements have clearly shown the presence of carbonaceous grains in the coma of comet Halley (Kissel et al., 1986). Laboratory investigations on AC grains may be very useful to better interpret observations and to support theoretical elaborations. Recently, the authors started an international research program which also includes UV extinction analyses on AC samples, by using synchrotron light. Preliminary results obtained in a first shift of measurements, last June, are given. At the present stage of the data analysis, the authors can only draw some preliminary considerations. A wide band falling at around 240 nm is detected in all the analyzed samples. It intensity seems to decrease with increasing the dust collecting distance. A peak at 150 nm decreases in intensity with increasing the collecting distance. The band seems absent in the samples characterized by a larger amount of dust. A feature at about 200 nm is detected in some samples. At the moment the authors tend to attribute it to the transmission properties of the LiF substrates at the wavelength and/or to some problems in the experimental setup. It is unclear if a hump at 120 nm is real or due to instrumental effects. The profile of the spectra does not show substantial changes when the samples are cooled down to about 100 K. The present results appear to be in general agreement with previous findings, but their analysis is in progress and the interpretation is still on the way.

Blanco, A.↗

Optoelectronic Control Of Phased-Array Antenna

Radiation patterns switched within microseconds. According to concept, digital beam-steering information destined for number of phased antenna elements transmitted in serial multiplex along optical fiber to optoelectronic integrated circuit (OEIC), demultiplexing information into parallel electronic channels to phase shifters associated with various elements. Because of small distances between elements of such arrays, compactness of optical fibers makes them attractive for distribution of beam-steering (phase-shifting) control signals. Also offers advantages of light weight, low attenuation, mechanical flexibility, large bandwidth, and immunity to both crosstalk and electromagnetic interference.

Bhasin, K. B.↗

A Determination of the Intergalactic Redshift Dependent UV-Optical-NIR Photon Density Using Deep Galaxy Survey Data and the Gamma-Ray Opacity of the Universe

We calculate the intensity and photon spectrum of the intergalactic background light (IBL) as a function of red shift using an approach based on observational data obtained at in different wavelength bands from local to deep galaxy surveys. Our empirically based approach allows us, for the firs.t time, to obtain a completely model independent determination of the IBL and to quantify its uncertainties. Using our results on the IBL, we then place upper and lower limits on the opacity of the universe to gamma-rays, independent of previous constraints.

Stecker, Floyd W.↗

Simple Refractometers for Index Measurements by Minimum Deviation Method from Far-ultraviolet to Near Infrared

The focal shift of an optical filter used in non-collimated light depends directly on substrate thickness and index of refraction. The HST Advanced Camera for Surveys (ACS) requires a set of filters whose focal shifts are tightly matched. Knowing the index of refraction for substrate glasses allows precise substrate thicknesses to be specified. Two refractometers have been developed at the Goddard Space Flight Center (GSFC) to determine the indices of refraction of materials from which ACS filters are made. Modem imaging detectors for the near infrared, visible, and far ultraviolet spectral regions make these simple yet sophisticated refractometers possible. A new technology, high accuracy, angular encoder also developed at GSFC makes high precision index measurement possible in the vacuum ultraviolet.

Leviton, Douglas B.↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

Degroot, Wilhelmus A.↗

Clear air turbulence detector

A system to be employed by an aircraft for the detection of clear air turbulence is described. The system employs a laser light beam which is directed ahead of the aircraft along the flight path. The portion of the light reflected back to the aircraft by atmospheric aerosol is detected and analyzed for Doppler shift. The velocity and intensity of the turbulence is determined by the type and amount of the light reflected.

Dahm, W. K.↗

Method and apparatus for Doppler frequency modulation of radiation

A method and apparatus are described for frequency modulating radiation, such as from a laser, for optoacoustic detectors, interferometers, heterodyne spectrometers, and similar devices. Two oppositely reciprocating cats-eye retroreflectors are used to Doppler modulate the radiation. By reciprocally moving both retroreflectors, the center of mass is maintained constant to permit smooth operation at many Hertz. By slightly offsetting the axis of one retroreflector relative to the other, multiple passes of a light beam may be achieved for greater Doppler shifts with the same reciprocating motion of the retroreflectors.

Margolis, J. S.↗

Nonlinear optical processing with Fabry-Perot interferometers containing phase recording media

New techniques in nonlinear optical processing are explored, based on the operation of intensity level selection as performed by a Fabry-Perot interferometer containing a phase object. The image being processed is recorded on a medium between the mirrors as a spatially varying phase shift less than pi. The interferometer only transmits light through those portions of the object that corresponds to a single value of the phase and hence to a single intensity level in the input. More complicated operations such as thresholding and analog-to-digital conversion are performed by modulating the light source as the different levels are selected. Photoresist and lithium niobate have been used as phase objects, and experimental data for both are presented. Three kinds of Fabry-Perot interferometers have been used to demonstrate nonlinear processing using coherent and incoherent light. Color images have been produced with black and white inputs and white light illumination.

Bartholomew, B. J.↗

Analysis of localized fringes in the holographic optical Schlieren system

The relation between localization of interference fringes in classical and holographic interferometry is reviewed and an application of holographic interferometry is considered for which the object is a transparent medium with nonhomogeneous refractive index. The technique is based on the analysis of the optical path length change of the object wave as it propagates through a transparent medium. Phase shifts due to variations of the speed of light within the medium give rise to an interference pattern. The resulting interferogram can be used to determine the physical properties of the medium or transparent object. Such properties include the mass density of fluids, electron densities of plasmas, the temperature of fluids, the chemical species concentration of fluids, and the state of stress in solids. The optical wave used can be either a simple plane or spherical wave, or it may be a complicated spatial wave scattered by a diffusing screen. The mathematical theory on the formation and analysis of localized fringes, the general theoretical concepts used, and a computer code for analysis are included along with the inversion of fringe order data.

Kurtz, R. L.↗

Virtual Instrumentation for a Fiber-Optics-Based Artificial Nerve

A LabView-based computer interface for fiber-optic artificial nerves has been devised as a Masters thesis project. This project involves the use of outputs from wavelength multiplexed optical fiber sensors (artificial nerves), which are capable of producing dense optical data outputs for physical measurements. The potential advantages of using optical fiber sensors for sensory function restoration is the fact that well defined WDM-modulated signals can be transmitted to and from the sensing region allowing networked units to replace low-level nerve functions for persons desirous of "intelligent artificial limbs." Various FO sensors can be designed with high sensitivity and the ability to be interfaced with a wide range of devices including miniature shielded electrical conversion units. Our Virtual Instrument (VI) interface software package was developed using LabView's "Laboratory Virtual Instrument Engineering Workbench" package. The virtual instrument has been configured to arrange and encode the data to develop an intelligent response in the form of encoded digitized signal outputs. The architectural layout of our nervous system is such that different touch stimuli from different artificial fiber-optic nerve points correspond to gratings of a distinct resonant wavelength and physical location along the optical fiber. Thus, when an automated, tunable diode laser sends scans, the wavelength spectrum of the artificial nerve, it triggers responses that are encoded with different touch stimuli by way wavelength shifts in the reflected Bragg resonances. The reflected light is detected and a resulting analog signal is fed into ADC1 board and DAQ card. Finally, the software has been written such that the experimenter is able to set the response range during data acquisition.

Lyons, Donald R.↗