Evidence of Free-Bound Transitions in Warm Dense Matter and Their Impact on Equation-of-State Measurements

Warm dense matter (WDM) is now routinely created and probed in laboratories around the world, providing unprecedented insights into conditions achieved in stellar atmospheres, planetary interiors, and inertial confinement fusion experiments. However, the interpretation of these experiments is often filtered through models with systematic errors that are difficult to quantify. Due to the simultaneous presence of quantum degeneracy and thermal excitation, transitions in which free electrons are de-excited into thermally unoccupied bound states transferring momentum and energy to a scattered x-ray photon become viable. Here we show that such free-bound transitions are a particular feature of WDM and vanish in the limits of cold and hot temperatures. The inclusion of these transitions into the analysis of recent X-ray Thomson Scattering experiments on WDM at the National Ignition Facility and the Linac Coherent Light Source is required to obtain a physically consistent temperature from the Chihara decomposition. This interpretation is corroborated by agreement with a recently developed model-free thermometry technique and presents an important step for precisely characterizing and understanding the complex WDM state of matter.

Boehme, M [HZDR Dresden]↗

Pseudoatom molecular dynamics plasma microfields

Spectral lines are powerful diagnostic tools for both laboratory and astrophysical plasmas, as their shape is sensitive to the plasma environment. The low-frequency component of the electric microfield is an important input for semi-analytic line broadening codes. Here, in this paper, we detail a new method of calculating plasma microfields using configuration-resolved pseudoatom molecular dynamics. This approach accounts for both quantum atomic structure and N-body effects, similar to density functional theory molecular dynamics, but with less computational cost. We present pseudoatom microfields at plasma conditions relevant for recent high energy density laboratory astrophysics experiments conducted at the Sandia Z-Machine, National Ignition Facility, and Linac Coherent Light Source. Compared to established microfield codes we find moderate deviations at solid density conditions and strong agreement at lower plasma densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applied radiation tags for warhead dismantlement transparency

Here, this study explores the feasibility of applying radiation tags as a Chain of Custody tool to confirm the dismantlement of individual warheads by investigating time dependent emissions from special nuclear material. Precedents of photon and neutron sources that have been used to irradiate warhead components are presented. Measurements of irradiated Highly Enriched Uranium (HEU) are used to benchmark simulations with the CINDER90 library for MCNP. Delayed gamma emissions are simulated as a function of time since irradiation of moderated HEU and Weapons Grade Plutonium with photon and neutron sources. Models of commercial 9 MV and 15 MV linacs were found to induce ~10 9 fissions/g and ~10 11 fissions/g, respectively, creating 3 to 4 orders of magnitude more delayed gammas than neutron sources, modeled at 10 10 n/s. However, a DT neutron source was found to induce sufficient fissions, ~10 7 fissions/g, to create quantifiable signatures relative to intrinsic emissions. Applied radiation tagging is determined to be technically feasible, but its operational context and practical implementation requires significant development.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Phase-Imaging Ion-Cyclotron-Resonance mass spectrometry with the Canadian Penning Trap at CARIBU

The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique for over half a decade. Here, in this study, we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.

Penning trap mass spectrometry↗

Cyclotron resonance accelerators for industrial applications

Here, this paper describes novel configurations for cyclotron resonance acceleration of electrons and ions that have several attractive features including: a compact robust room-temperature single-cell RF cavity as the accelerator structure; and continuous high current accelerated un-bunched beam output with self-scanning, obviating need for a separate beam scanner. An electron accelerator version, the electron Cyclotron Resonance Accelerator (eCRA), is under development to be an efficient source for high power electron and x-ray beams for medical, research, sterilization, and National Security applications, so as to replace radioactive materials. An ion accelerator version, the ion Cyclotron Auto-Resonance Accelerator (iCARA) is described here, suggesting its potential to produce, as an example, a high-current multi-MeV beam of deuterons which could be highly competitive with that produced either with linacs or cyclotrons. Such a deuteron beam could produce a high flux of fast neutrons via deuteron stripping, for applications including the transmutation of used nuclear fuel, material studies relevant for a fusion reactor inner wall, tritium breeding and medical isotope production. For the high-current, high efficiency simulated performance for eCRA and iCARA as described in this paper, the particle beams produced may not exhibit the low emittance values that are important for most discovery research. Rather, the beams could be useful for industrial applications where higher emittance and some energy spread can be tolerated, in favor of high beam power.

43 PARTICLE ACCELERATORS↗

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES↗

Recent progress in high-temperature superconducting undulators

Considerable effort has been devoted to the development of superconducting undulators (SCUs) intended for particle accelerator-based light sources, including synchrotrons and free electron laser (FEL) facilities. Recently, a high-temperature superconducting (HTS) undulator prototype, consisting of staggered-array Re-Ba-Cu-O bulks, achieved an on-axis sinusoidal magnetic field profile with a peak amplitude B$_0$ of 2.1 T and a period length of 10 mm, resulting in a deflection parameter K = 1.96. Such a short period HTS undulator not only enables the generation of higher-energy photons, but also supports the construction of economically feasible and compact FELs with shorter linear accelerators (LINACs). This article provides a comprehensive review of recent advances in the staggered-array bulk HTS undulator as well as other types of HTS undulators. Furthermore, it offers insights into the development of engineering HTS undulator prototypes designed for deployment in synchrotron and free electron laser (FEL) facilities. We conclude by discussing opportunities for and the challenges facing the use of HTS undulators in practical applications.

43 PARTICLE ACCELERATORS↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Structural evolution of liquid silicates under conditions in Super-Earth interiors

Molten silicates at depth are crucial for planetary evolution, yet their local structure and physical properties under extreme conditions remain elusive due to experimental challenges. In this study, we utilize in situ X-ray diffraction (XRD) at the Matter in Extreme Conditions (MEC) end-station of the Linear Coherent Linac Source (LCLS) at SLAC National Accelerator Laboratory to investigate liquid silicates. Using an ultrabright X-ray source and a high-power optical laser, we probed the local atomic arrangement of shock-compressed liquid (Mg,Fe)SiO 3 with varying Fe content, at pressures from 81(9) to 385(40) GPa. We compared these findings to ab initio molecular dynamics simulations under similar conditions. Results indicate continuous densification of theO-O and Mg-Si networks beyond Earth’s interior pressure range, potentially altering melt properties at extreme conditions. This could have significant implications for early planetary evolution, leading to notable differences in differentiation processes between smaller rocky planets, such as Earth and Venus, and super-Earths, which are exoplanets withmasses nearly three times that of Earth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray diffraction of metastable structures from supercooled liquid hydrogen

We report time resolved observations of the crystallization from liquid hydrogen, supercooled to temperatures below the melting point, using 11.2 keV X-ray diffraction from the Linac Coherent Light Source (LCLS). Changes to the metastable solid and liquid structure factors have been dynamically measured. This allows for a direct determination of the lowest energy crystal polymorphs, the stacking probabilities, as well as the liquid and solid densities and temperatures. Such measurements provide experimental evidence of an Arrhenius-like growth kinetics along the stacking direction during supercooling.

36 MATERIALS SCIENCE↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Production and performance of a 172 Hf/ 172 Lu generator

A 172 Hf/ 172 Lu radionuclide generator system to produce 172 Lu for laboratory scale applications in lutetium-based radiochemistry development was established and evaluated. The parent 172 Hf radionuclide was produced through 35.2 MeV proton irradiation of natural lutetium metal foil at the Brookhaven Linac Isotope Producer. Four resins were investigated for 172 Hf separation from bulk Lu target material: LN resin, ZR resin, in-house synthesized hydroxamate, and methyl-substituted hydroxamate resins, all with comparable performance. Separated 172 Hf was consolidated and used to create a ZR resin-based 4.9(3) MBq 172 Hf/ 172 Lu generator which was eluted 49 times over two years with no observed breakthrough of 172 Hf, and an average elution efficiency of 98(1)%. The eluted 172 Lu was used to radiolabel the macrocyclic chelator DOTA with an apparent molar activity of 8(2)x10 2 kBq/nmol.

172Hf/172Lu radionuclide generator↗

Study of ablation and shock generation across three orders of magnitude of laser intensity with 100 ps laser pulses

The laser ablation and subsequent shock generation in solid targets plays an important role in a variety of research topics from equation of state models for materials to inertial confinement fusion. One of the long-standing issues is the knowledge of ablation depth in the picosecond time regime. Here, we report on a direct technique for determining the ablation depth in aluminum using x-ray diffraction data from Linac Coherent Light Source at the Stanford Linear Accelerator Center. This technique gives a direct measurement of the shock wave propagation in the bulk target, enabling an ability to discern early timescale physics from late timescale effects not available in postmortem analysis. We find that the ablation depths only vary by 0.2 μm across three orders of magnitude of laser intensity, while the pressure increased by a factor of 10 following a square root dependence on laser pulse energy. We further observe that the ablation depth in this intensity range (10 11 –10 13 W/cm 2 in intensity, corresponding to 0.8–80 J/cm 2 in fluence) cannot be modeled by a universal scaling law, given the complexity of the mechanisms governing laser ablation in this intensity regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of closed shell breeding of cesium ions with an electron beam ion source

An electron beam ion source serves as a charge breeder for the Californium Rare Isotope Breeder Upgrade (CARIBU) at the Argonne Tandem Linac Accelerator System (ATLAS). The source accepts radioactive beams of 1+ or 2+ ions and raises their charge state for post-acceleration by ATLAS. The efficiency of this process impacts the length of each experiment and, hence, the type and number of experiments that can be run in each program cycle. Recent efforts to improve the charge breeding efficiency for the 80 < A < 160 species typical of CARIBU have focused on utilizing the closed shell breeding technique. Here, with this technique, the electron beam energy is manipulated to take advantage of the large gap in ionization energies at shell closures and selectively populate a single charge state. Charge breeding studies with stable cesium ions have demonstrated an absolute efficiency of 72% for Cs 27+ and a total efficiency of 93%. The Cs 27+ efficiency result represents a factor of 3 improvement over the previous best charge breeding result of 23% for Cs 27+ .

Vondrasek, R. [Argonne National Laboratory (ANL), ↗

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state↗

Characterizing laser-heated polymer foams with simultaneous x-ray fluorescence spectroscopy and Thomson scattering at the Matter in Extreme Conditions Endstation at LCLS

Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗