Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Pluto’s Sputnik Planitia: Composition of geological units from infrared spectroscopy

We have compared spectroscopic data of Sputnik Planitia on Pluto, as acquired by New Horizons’ Linear Etalon Imaging Spectral Array (LEISA) instrument, to the geomorphology as mapped by White et al. (2017) using visible and panchromatic imaging acquired by the LOng-Range Reconnaissance Imager (LORRI) and the Multi-spectral Visible Imaging Camera (MVIC). We have focused on 13 of the geologic units identified by White et al. (2017), which include the plains and mountain units contained within the Sputnik basin. We divided the map of Sputnik Planitia into 15 provinces, each containing one or more geologic units, and we use LEISA to calculate the average spectra of the units inside the 15 provinces. Hapke-based modeling was then applied to the average spectra of the units to infer their surface composition, and to determine if the composition resulting from the modeling of LEISA spectra reflects the geomorphologic analyses of LORRI data, and if areas classified as being the same geologically, but which are geographically separated, share a similar composition. We investigated the spatial distribution of the most abundant ices on Pluto’s surface - CH4, N2, CO, H2O, and a non-ice component presumed to be a macromolecular carbon-rich material, termed a tholin, that imparts a positive spectral slope in the visible spectral region and a negative spectral slope longward of ~1.1 μm. Because the exact nature of the non-ice component is still debated and because the negative spectral slope of the available tholins in the near infrared does not perfectly match the Pluto data, for spectral modeling purposes we reference it generically as the negative spectral slope endmember (NSS endmember). We created maps of variations in the integrated band depth (from LEISA data) and areal mass fraction (from the modeling) of the components. The analysis of correlations between the occurrences of the endmembers in the geologic units led to the observation of an anomalous suppression of the strong CH4 absorption bands in units with compositions that are dominated by H2O ice and the NSS endmember. Exploring the mutual variation of the CH4 and N2 integrated band depths with the abundance of crystalline H2O and NSS endmember revealed that the NSS endmember is primarily responsible for the suppression of CH4 absorptions in mountainous units located along the western edge of Sputnik Planitia. Our spectroscopic analyses have provided additional insight into the geological processes that have shaped Sputnik Planitia. A general increase in volatile abundance from the north to the south of Sputnik Planitia is observed. Such an increase first observed and interpreted by Protopapa et al., 2017 and later confirmed by climate modeling (Bertrand et al., 2018) is expressed geomorphologically in the form of preferential deposition of N2 ice in the upland and mountainous regions bordering the plains of southern Sputnik Planitia. Relatively high amounts of pure CH4 are seen at the southern Tenzing Montes, which are a natural site for CH4 deposition owing to their great elevation and the lower insolation they are presently receiving. The NSS endmember correlates the existence of tholins within certain units, mostly those coating the low-latitude mountain ranges that are co-latitudinal with the tholin-covered Cthulhu Macula. The spectral analysis has also revealed compositional differences between the handful of occurrences of northern non-cellular plains and the surrounding cellular plains, all of which are located within the portion of Sputnik Planitia that is presently experiencing net sublimation of volatiles, and which do not therefore exhibit a surface layer of bright, freshly-deposited N2 ice. The compositional differences between the cellular and non-cellular plains here hint at the effectiveness of convection in entraining and trapping tholins within the body of the cellular plains, while preventing the spread of such tholins to abutting non-cellular plains.

Pluto's Sputnik Planitia↗

Effectiveness of basic display augmentation in vehicular control by visual field cues

The paper investigates the effectiveness of different basic display augmentation concepts - fixed reticle, velocity vector, and predicted future vehicle path - for RPVs controlled by a vehicle-mounted TV camera. The task is lateral manual control of a low flying RPV along a straight reference line in the presence of random side gusts. The man-machine system and the visual interface are modeled as a linear time-invariant system. Minimization of a quadratic performance criterion is assumed to underlie the control strategy of a well-trained human operator. The solution for the optimal feedback matrix enables the explicit computation of the variances of lateral deviation and directional error of the vehicle and of the control force that are used as performance measures.

Grunwald, A. J.↗

Telerobotic truss assembly

The ACCESS truss was telerobotically assembled in order to gain experience with robotic assembly of hardware designed for astronaut extravehicular (EVA) assembly. Tight alignment constraints of the ACCESS hardware made telerobotic assembly difficult. A wider alignment envelope and a compliant end effector would have reduced the problem. The manipulator had no linear motion capability, but many of the assembly operations required straight line motion. The manipulator was attached to a motion table in order to provide the X, Y, and Z translations needed. A programmable robot with linear translation capability would have eliminated the need for the motion table and streamlined the assembly. Poor depth perception was a major problem. Shaded paint schemes and alignment lines were helpful in reducing this problem. The four cameras used worked well for only some operations. It was not possible to identify camera locations that worked well for all assembly steps. More cameras or movable cameras would have simplified some operations. The audio feedback system was useful.

Sheridan, Philip L.↗

The Fringe-Imaging Skin Friction Technique PC Application User's Manual

A personal computer application (CXWIN4G) has been written which greatly simplifies the task of extracting skin friction measurements from interferograms of oil flows on the surface of wind tunnel models. Images are first calibrated, using a novel approach to one-camera photogrammetry, to obtain accurate spatial information on surfaces with curvature. As part of the image calibration process, an auxiliary file containing the wind tunnel model geometry is used in conjunction with a two-dimensional direct linear transformation to relate the image plane to the physical (model) coordinates. The application then applies a nonlinear regression model to accurately determine the fringe spacing from interferometric intensity records as required by the Fringe Imaging Skin Friction (FISF) technique. The skin friction is found through application of a simple expression that makes use of lubrication theory to relate fringe spacing to skin friction.

Zilliac, Gregory G.↗

ON THE ACCURACY OF MEASUREMENTS MADE UPON FILMS PHOTOGRAPHED BY BAKER-NUNN SATELLITE TRACKING CAMERAS

The photographs taken by the Baker-Nunn cameras of the Smithsonian Astrophysical Observatory were formerly measured with Van Biesbroeck goniometers, but are now measured exclusively with Mann two-screw comparators. Instead of measuring point images, we usually have to measure oblong images, either trails or breaks (the latter produced by interruption of the exposure). We can therefore expect that the accuracy of the determination of their positions is more influenced by the personal errors than it is in conventional astrometry. Approximately 800 measurements were made on 34 images of different length, and, from these, the frequency distribution of settings was determined. Then the relationship between this distribution and the length of the image (trail or break) was examined, and the relationship between the "magnitude error" and the length of image was determined. Measurements were made at different angles formed by the trails and the reticle lines, and it was found that the accuracy was not affected by the angle of the setting. Position determinations have been made using reference stars at different distances. On the basis of these results, we can conclude that the accuracy is neither influenced by the distortion of the emulsion nor by the optical distortion within an area of a diameter of S cm (5°.8). We believe that we are justified in using the linear plate constant method, at least within this area. From numerous double and multiple measurements, the following standard errors were determined for a single position.

ASTROMETRY↗

High-Speed Linear Raman Spectroscopy for Instability Analysis of a Bluff Body Flame

We report a high-speed laser diagnostics technique based on point-wise linear Raman spectroscopy for measuring the frequency content of a CH4-air premixed flame stabilized behind a circular bluff body. The technique, which primarily employs a Nd:YLF pulsed laser and a fast image-intensified CCD camera, successfully measures the time evolution of scalar parameters (N2, O2, CH4, and H2O) in the vortex-induced flame instability at a data rate of 1 kHz. Oscillation of the V-shaped flame front is quantified through frequency analysis of the combustion species data and their correlations. This technique promises to be a useful diagnostics tool for combustion instability studies.

Kojima, Jun↗

More About Video-Feedback Docking System

Two documents provide additional information on system described in "Docking System With Video Feedback" (MFS-28421). First document, "Standard Remote Manipulator System Docking Target Augmentation For Automated Docking", emphasizes use of retroreflectors in target. Second document, "Development Of A Video-Based Automatic Rendezvous And Docking System", describes hardware and software of system. System is video-sensor/electronic-feedback control system. Video camera on active or chasing vehicle views target on passive or chased vehicle. Target illuminated by light-emitting diodes on active vehicle. Image-data-processing subsystem converts video image of target into data on relative position, orientation, linear velocity, and angular velocity of two vehicles. Data then used by maneuver-control subsystem to control approach of active vehicle to passive vehicle.

Howard, Richard↗

Using Enviro-Pod low altitude imagery to inventory building surface materials for an acid rain study - A Baltimore example

Low altitude, oblique and vertical color photography taken from EPA's Enviro-Pod Ka 85 camera system has provided the data for taking an inventory of building surface materials in a test area of downtown Baltimore. Photography was acquired from a gridded flight plan to provide views of all sides of buildings. Color, texture, and linear detail are employed in the photo interpretation aided by contextual reference to a classification of building construction type developed in an earlier study. The work could potentially support a materials inventory initiated by the National Acid Precipitation Assessment Program (NAPAP) by scientists from EPA, Geological Survey, and the Department of Energy. Initial results show the method to be viable. Discrete surface materials such as brick, both bare and painted, stone, and metal are identified.

Ellefsen, Richard↗

Ice Growth Measurements from Image Data to Support Ice-Crystal and Mixed-Phase Accretion Testing

This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.

Struk, Peter, M↗

Ice Growth Measurements from Image Data to Support Ice Crystal and Mixed-Phase Accretion Testing

This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.

Struk, Peter M.↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Quantitative measurements of Jupiter, Saturn, their rings and satellites made from Voyager imaging data

The Voyager spacecraft cameras use selenium-sulfur slow scan vidicons to convert focused optical images into sensible electrical signals. The vidicon-generated data thus obtained are the basis of measurements of much greater precision than was previously possible, in virtue of their superior linearity, geometric fidelity, and the use of in-flight calibration. Attention is given to positional, radiometric, and dynamical measurements conducted on the basis of vidicon data for the Saturn rings, the Saturn satellites, and the Jupiter atmosphere.

Collins, S. A.↗

A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope

In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.

Benford, Dominic↗

A technique for constructing spectral reflectance curves from Viking lander camera multispectral data

A technique for evaluating the construction of spectral reflectance curves from multispectral data obtained with the Viking lander cameras is presented. The multispectral data is limited to 6 channels in the wave-length range 0.4 to 1.1 microns, and several of the channels suffer from appreciable out-of-band response. The technique represents the estimated reflectance curves as a linear combination of known basic functions with coefficients determined to minimize the error in the representation, and it permits all channels, with and without out-of-band response, to contribute equally valid information. The technique is evaluated for known spectral reflectance curves of 8 materials felt likely to be present on the Martian surface. The technique provides an essentially exact fit if the the reflectance curve has no pronounced maxima and minima. Even if the curve has pronounced maxima and minima, the fit is good and reveals the most dominant features. Since only 6 samples are available some short period features are lost. This loss is almost certainly due to undersampling rather than out-of-band channel response.

Park, S. K.↗

A quasi-static method for determining the characteristics of a motion capture camera system in a "split-volume" configuration

The purpose of this study was to determine the accuracy, repeatability and resolution of a six-camera Motion Analysis system in a vertical split-volume configuration using a unique quasi-static methodology. The position of a reflective marker was recorded while it was moved quasi-statically over a range of 2.54 mm (0.100 inches) via a linearly-translating table. The table was placed at five different heights to cover both sub-volumes and the overlapping region. Data analysis showed that accuracy, repeatability and resolution values were consistent across all regions of the split-volume, including the overlapping section.

NASA Center JSC↗

Linear Covariance Analysis For Proximity Operations Around Asteroid 2008 EV5

The NASA initiative to collect an asteroid the Asteroid Robotic Redirect Mission (ARRM) is currently investigating the option of retrieving a boulder off an asteroid, demonstrating planetary defense with an enhanced gravity tractor technique and returning it to a lunar orbit. Techniques for accomplishing this are being investigated by the Satellite Servicing Capabilities Office (SSOO) and NASA GSFC in colloboration with JPL, NASA, JSC, LaRC, and Draper Laboratories Inc. Two critical phases of the mission are the descent to the boulder and the Enhanced Gravity Tractor-enhanced gravity tractor demonstration. A linear covariance analysis was done for these phases to assess the feasibility of these concepts with the proposed design of the sensor and actuaor suite of the Asteroid Redirect Vehicle (ARV). The sensor suite for this analysis will include a wide field of view camera, Lidar, and a MMU. The proposed asteroid of interest is currently the C-type asteroid 2008 EV5, a carbonaceous chondrite that is of high interest to the scientific community. This paper will present an overview of the analysis discuss sensor and actuator models and address the feasibility of descending to the boulder within the requirements as the feasibility of maintaining the halo orbit in order to demonstrate the Enhanced Gravity Tractor-enhanced gravity tractory technique.

Guidance↗

Mariner 9 photometric observations of Mars from November 1971 through March 1972

The large quantity of Mariner 9 television pictures taken at phase angles ranging up to twice those accessible from earth has been used to describe integrated photometric properties of Mars. Although frame-to-frame variations emphasize the shortcomings of vidicon cameras when used in a photometric mode, statistical trends have yielded data comparable with earth-based observations. Analysis of atmospheric parameters over a period of changing opacity - November 1971 through March 1972 - has provided time-varying optical depths and light-scattering information. Linear function characterization of the Mars reflectance is clearly discrepant at large incidence or emission angles and at phase angles greater than 40 deg.

Thorpe, T. E.↗

Morphological Evolution of Directional Solidification Interfaces in Microgravity: An Analysis of Model Experiments Performed on the International Space Station

A series of experiments performed using the Pore Formation and Mobility Investigation (PFMI) apparatus within the glovebox facility (GBX) on board the International Space Station (ISS) has provided video images of the morphological evolution of a three-dimensional interface in a diffusion controlled regime. The experimental samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with "alloys" of succinonitrile (SCN) and water in an atmosphere of nitrogen at 450 millibar pressure. The compositions of the samples processed and analyzed are 0.25,0.5 and 1.0 wt% water. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall !3pace Flight Center. During the experiments, the sample was first subjected to a unidirectional melt back, generally at 10 microns per second, with a constant temperature gradient ahead of the melting interface. Following the melt back, the interface was allowed to stabilize before translation is initiated. The temperatures in the sample were monitored by six in situ thermocouples and the position is monitored by an optical linear encoder. For the experiments performed and analyzed, the gradients ranged from 2.5 - 3.3 K/mm and the initial pulling velocities ranged from 0.7 micron per second to 1 micron per second with subsequent transition velocities of up to 100 microns per second. The data provided by the PFMI for analysis includes near-real-time (NRT) video captured on the ground during the experiment runs, ISS Video Tape Recorder (VTR) data dumped from the VTR at the end of the experiment run and recorded on the ground, telemetry data including temperature and position measurements, and limited flight HI-8 tapes in 2 camera views of experiment runs for which tapes have been returned to the investigators from ISS. Because of limited down mass from the ISS, the majority of the initial analysis has been performed using the NRT and VTR video data but will be supplemented with the HI-8 video as it becomes available. hardware and procedures required to prepare samples for correlation to flight samples is described. Using this ground-based system, a series of experiments have been performed for direct comparison with the flight data. The results of these comparisons as well as implications to future microgravity experiments are presented and discussed. A ground-based thin-sample directional solidification system as well as all associated

Strutzenberg, Louise L.↗