Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear induction accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Diagnostic and Power Feed Upgrades to the MAIZE Facility

The Michigan Accelerator for Inductive Z-pinch experiments (MAIZE) is a one stage, 1 MA, Linear Transformer Driver (LTD) at the University of Michigan. The MAIZE facility has been the site of various experimental studies, including wire array z-pinches for x-ray source development and cylindrical foil loads for implosion stability analysis. Here, in order to better understand and investigate these and other experiments, a 4- frame extreme ultraviolet (EUV) camera was implemented, the optical stability of a 12-frame laser shadowgraphy system was improved, B-dot probes were upgraded, and a Rogowski coil was constructed. New conical load hardware was also developed to reduce the inductance of the transmission line and thus improve the current delivered to the loads.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAIZE: a 1 MA LTD-Driven Z-Pinch at The University of Michigan

Researchers at The University of Michigan have constructed and tested a 1-MA Linear Transformer Driver (LTD), the first of its type to reach the USA. The Michigan Accelerator for Inductive Z-pinch Experiments, (MAIZE), is based on the LTD developed at the Institute of High Current Electronics in collaboration with Sandia National Labs and UM. This LTD utilizes 80 capacitors and 40 spark gap switches, arranged in 40 'bricks,' to deliver a 1 MA, 100 kV pulse with 100 ns risetime into a matched resistive load. Preliminary resistive-load test results are presented for the LTD facility.Planned experimental research programs at UM include: a) Studies of Magneto-Raleigh-Taylor instability of planar foils, and b) Vacuum convolute studies including cathode and anode plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Megavoltage cone beam CT near surface dose measurements: potential implications for breast radiotherapy

Purpose: Cone beam computed tomography (CBCT) is fast becoming standard on modern linear accelerators. CBCT increases the dose to regions within and outside the treatment field, potentially increasing secondary cancer induction and toxicity. This study quantified megavoltage (MV) CBCT skin dose and compared it to skin dose delivered during standard tangential breast radiotherapy.Method: Dosimetry was performed both in- and out-of-field using thermoluminescent dosimeters (TLDs) and a metal-oxide-semiconductor-field-effect-transistor (MOSFET) detector specifically designed for skin dosimetry; these were placed superficially on a female anthropomorphic phantom. Results: The skin dose from a single treatment fraction ranged from 0.5 to 1.4 Gy on the ipsilateral breast, 0.031-0.18 Gy on the contralateral breast, and 0-0.02 Gy in the head and pelvic region. An 8 MU MV CBCT delivered a skin dose that ranged from 0.02 to 0.05 Gy in the chest region and was less than 0.01 Gy in the head and pelvis regions. One MV CBCT per fraction was found to increase the out-of-field skin dose from both the CBCT and the treatment fields by approximately 20%. The imaging dose as a percentage of treatment doses in the ipsilateral breast region was 3% for both dosimeters.Conclusion: Imaging increases the skin dose to regions outside the treatment field particularly regions immediately adjacent the target volume. This small extra dose to the breasts should be considered when developing clinical protocols and assessing dose for clinical trials.

61 RADIATION PROTECTION AND DOSIMETRY↗

NDCX-II, an Induction Linac for HEDP and IFE Research

The Heavy Ion Fusion Science Virtual National Laboratory in the USA is constructing a new Neutralized Drift Compression eXperiment (NDCX-II) at LBNL. This facility is being developed for high energy density physics and inertial fusion energy research. The 12 m long induction linac in NDCX-II will produce a Li{sup +} beam pulse, at energies of 1.2-3 MeV, to heat target material to the warm dense matter regime ({approx} 1 eV). By making use of special acceleration voltage waveforms, 2.5T solenoid focusing, and neutralized drift compression, 20 - 50 nC of beam charge from the ion source will be compressed longitudinally and radially to achieve a subnanosecond pulse length and mm-scale target spot size. The original Neutralized Drift Compression Experiment (NDCX-I) has successfully demonstrated simultaneous radial and longitudinal compression by imparting a velocity ramp to the ion beam, which then drifts in a neutralizing plasma to and through the final focussing solenoid and onto the target. At higher kinetic energy and current, NDCX-II will offer more than 100 times the peak energy fluence on target of NDCX-I. NDCX-II makes use of many parts from the decommissioned Advanced Test Accelerator (ATA) at LLNL. It includes 27 lattice periods between the injector and the neutralized drift compression section (Figure 1). There are 12 energized induction cells, 9 inactive cells which provide drift space, and 6 diagnostic cells which provide beam diagnostics and pumping. Custom pulsed power systems generate ramped waveforms for the first 7 induction cells, so as to quickly compress the beam from 600 ns at the injector down to 70 ns. After this compression, the high voltages of the ATA Blumleins are then used to rapidly add energy to the beam. The Blumleins were designed to match the ferrite core volt-seconds with pulses up to 250 kV and a fixed FWHM of 70 ns. The machine is limited to a pulse repetition rate of once every 20 seconds due to cooling requirements. The NDCX-II beam is highly space-charge dominated. The 1-D ASP code was used to synthesize high voltage waveform for acceleration, while the 3-D Warp particle-in-cell code was used for detailed design of the lattice. The Li{sup +} ion was chosen because its Bragg Peak energy (at {approx} 2 MeV) coincides with the NDCX-II beam energy. The 130 keV injector will have a 10.9 cm diameter ion source. Testing of small (0.64 cm diameter) lithium doped alumino-silicate ion sources has demonstrated the current density ({approx} 1 mA/cm{sup 2}) used in the design, with acceptable lifetime. A 7.6 cm diameter source has been successfully produced to verify that the coating method can be applied to such a large emitting area. The ion source will operate at {approx} 1275 C; thus a significant effort was made in the design to manage the 4 kW heating power and the associated cooling requirements. In modifying the ATA induction cells for NDCX-II, the low-field DC solenoids were replaced with 2.5 T pulsed solenoids. The beam pipe diameter was decreased in order to reduce the axial extent of the solenoid fringe fields and to make room for water cooling. In addition, an outer copper cylinder (water-cooled) was used to exclude the solenoid magnetic flux from the ferrite cores. Precise alignment is essential because the beam has a large energy spread due to the rapid pulse compression, such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. A novel pulsed-wire measurement method is used to align the pulsed solenoid magnets. Alignment accuracy has been demonstrated to within 100 {micro}m of the induction cell axis. The neutralized drift compression region after the last induction cell is approximately 1.2 m long and includes ferroelectric plasma sources (FEPS) fabricated by PPPL similar to those successfully operating in NDCX-I. The 8-T final focus pulsed solenoid, filtered cathodic arc plasma sources (FCAPS), and target chamber from NDCX-I are to be relocated to NDCX-II. The NDCX-II project started in July 2009 and is expected to complete in fall of 2011. As future funds become available, additional induction cells and pulsed power systems will be added to increase the beam energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mutagenic effect of accelerated heavy ions on bacterial cells

The heavy ion accelerators of the Joint Institute for Nuclear Research were used to study the regularities and mechanisms of formation of different types of mutations in prokaryote cells. The induction of direct (lac{sup −}, ton B{sup −}, col B) mutations for Esherichia coli cells and reverse his{sup −} → His{sup +} mutations of Salmonella typhimurium, Bacillus subtilis cells under the action of radiation in a wide range of linear energy transfer (LET) was studied. The regularities of formation of gene and structural (tonB trp-) mutations for Esherichia coli bacteria under the action of accelerated heavy ions were studied. It was demonstrated that the rate of gene mutations as a function of the dose under the action of Γ rays and accelerated heavy ions is described by linear-quadratic functions. For structural mutations, linear “dose-effect” dependences are typical. The quadratic character of mutagenesis dose curves is determined by the “interaction” of two independent “hitting” events in the course of SOS repair of genetic structures. The conclusion made was that gene mutations under the action of accelerated heavy ions are induced by δ electron regions of charged particle tracks. The methods of SOS chromotest, SOS lux test, and λ prophage induction were used to study the regularities of SOS response of cells under the action of radiations in a wide LET range. The following proposition was substantiated: the molecular basis for formation of gene mutations are cluster single-strand DNA breaks, and that for structural mutations, double-strand DNA breaks. It was found out that the LET dependence of the relative biological efficiency of accelerated ions is described by curves with a local maximum. It was demonstrated that the biological efficiency of ionizing radiations with different physical characteristics on cells with different genotype, estimated by the lethal action, induction of gene and deletion mutations, precision excision of transposons, is determined by the specific features of energy transfer of the radiations that affect the character of induced DNA damage, and the efficiency inducible and constitutive cell repair systems. The growth of relative biological efficiency of heavy charged particles is determined by the growth of the damage yield of the DNA participating in the formation of radiation-induced effects, and higher efficiency of inducible repair systems. It was established that the LET value (L{sub max}) for which the maximum (according to the applied irradiation criteria) coefficients of relative biological efficiency are observed varies depending on the character of the registered radiation induced effect. It was demonstrated that for gene mutations and induction of precision excision of mobile elements the values of L{sub max} are realized in a LET range of ≈20 keV/μm. For lethal effects of irradiation and induction of deletion mutations the value of L{sub max} is ≈ 100 and 50 keV/μm, respectively. The differences in the L{sub max} for the studied radiation gene effectis are determined by the different type of DNA damage participating in the mutation process. A molecular model of the formation of gene mutations in Escherichia coli cells under the action of ionizing radiation was proposed. Basic DNA radiation damage and main repair ways were considered in the framework of this model. The basis is the idea of the decisive role of mutagenic, error-prone, branch of SOS repair in fixing premutation DNA damage into point mutations. It was demonstrated that the central mechanism in this process is the formation of an inducible multi-enzymatic complex including the DNA polymerase V (Umu C), RecA-protease, SSB proteins, subunits of DNA polymerase III, performing erroneous DNA synthesis on the damaged matrix. A mathematical model of induction of gene mutations under ultraviolet cell irradiation was developed based on the molecular model.

60 APPLIED LIFE SCIENCES↗

Recent Upgrade of the Klystron Modulator at SLAC

The SLAC National Accelerator Laboratory employs 244 klystron modulators on its two-mile-long linear accelerator that has been operational since the early days of the SLAC establishment in the sixties. Each of these original modulators was designed to provide 250 kV, 262 A and 3.5 {mu}S at up to 360 pps using an inductance-capacitance resonant charging system, a modified type-E pulse-forming network (PFN), and a pulse transformer. The modulator internal control comprised of large step-start resistor-contactors, vacuum-tube amplifiers, and 120 Vac relays for logical signals. A major, power-component-only upgrade, which began in 1983 to accommodate the required beam energy of the SLAC Linear Collider (SLC) project, raised the modulator peak output capacity to 360 kV, 420 A and 5.0 {mu}S at a reduced pulse repetition rate of 120 pps. In an effort to improve safety, performance, reliability and maintainability of the modulator, this recent upgrade focuses on the remaining three-phase AC power input and modulator controls. The upgrade includes the utilization of primary SCR phase control rectifiers, integrated fault protection and voltage regulation circuitries, and programmable logic controllers (PLC) -- with an emphasis on component physical layouts for safety and maintainability concerns. In this paper, we will describe the design and implementation of each upgraded component in the modulator control system. We will also report the testing and present status of the modified modulators.

43 PARTICLE ACCELERATORS↗

On the electric activity of superfluid helium at the excitation of first and second sound waves

We show that the electric activity of superfluid helium (HeII) observed in the experiments [3] during the excitation of standing second sound waves in an acoustic resonator can be described in terms of the phenomenological mechanism of the inertial polarization of atoms in a dielectric, in particular, in HeII, when the polarization field induced in the medium is proportional to the mechanical acceleration, by analogy with the Stewart-Tolman effect. The variable relative velocity w = v{sub n} - v{sub s} of the normal and superfluid HeII components that emerges in the second sound wave determines the mean group velocity of rotons, V{sub g} Almost-Equal-To w, with the density of the normal component related to their equilibrium number density in the temperature range 1.3 K {<=} T {<=} 2 K. Therefore, the acceleration of the 4He atoms involved in the formation of a roton excitation is proportional to the time derivative of the relative velocity.w. In this case, the linear local relations between the variable values of the electric induction, electric field strength, and polarization vector should be taken into account. As a result, the variable displacement current induced in the bulk of HeII and the corresponding potential difference do not depend on the anomalously low polarizability of liquid helium. This allows the ratio of the amplitudes of the temperature and potential oscillations in the second sound wave, which is almost independent of T in the above temperature range, consistent with experimental data to be obtained. At the same time, the absence of an electric response during the excitation of first sound waves in the linear regime is related to an insufficient power of the sound oscillations. Based on the experimental data on the excitation of first and second sounds, we have obtained estimates for the phenomenological coefficient of proportionality between the polarization vector and acceleration and for the drag coefficient of helium atoms by rotons in the second sound wave. We also show that the presence of a steady heat flow in HeII with nonzero longitudinal velocity and temperature gradients due to finite viscosity and thermal conductivity of the normal component leads to a change in the phase velocities of the first and second sound waves and to an exponential growth of their amplitudes with time, which should cause the amplitudes of the electric signals at the first and second sound frequencies to grow. This instability is analogous to the growth of the amplitude of long gravity waves on a shallow-water surface that propagate in the direction of decreasing basin depth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Loss current minimization during ion extraction from an inductively coupled plasma

In ion sources with a grid-type acceleration system, the output current often decreases with increasing power at a constant extraction voltage despite the fact that the carrier density inside the source increases linearly. At this point, the loss and output currents have the same magnitude. This paper proposes a mechanism for loss current minimization when restrictions are placed on the beam focusing efficiency with increasing rf power. The influence of the plasma potential on the magnitude of the loss current was examined. The beam intensity was found to increase considerably when the plasma potential was sufficiently high to suppress sheath curvature growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient algorithm for locating and sizing series compensation devices in large power transmission grids: I. Model implementation

We explore optimization methods for planning the placement, sizing and operations of Flexible Alternating Current Transmission System (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to Series Compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l 1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of Linear Programs (LP) which are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPower Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed up that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically-sized networks that suffer congestion from a range of causes including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically-sized network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient Algorithm for Locating and Sizing Series Compensation Devices in Large Transmission Grids: Model Implementation (PART 1)

We explore optimization methods for planning the placement, sizing and operations of Flexible Alternating Current Transmission System (FACTS) devices installed to relieve transmission grid congestion. We limit our selection of FACTS devices to Series Compensation (SC) devices that can be represented by modification of the inductance of transmission lines. Our master optimization problem minimizes the l 1 norm of the inductance modification subject to the usual line thermal-limit constraints. We develop heuristics that reduce this non-convex optimization to a succession of Linear Programs (LP) which are accelerated further using cutting plane methods. The algorithm solves an instance of the MatPower Polish Grid model (3299 lines and 2746 nodes) in 40 seconds per iteration on a standard laptop—a speed up that allows the sizing and placement of a family of SC devices to correct a large set of anticipated congestions. We observe that our algorithm finds feasible solutions that are always sparse, i.e., SC devices are placed on only a few lines. In a companion manuscript, we demonstrate our approach on realistically-sized networks that suffer congestion from a range of causes including generator retirement. In this manuscript, we focus on the development of our approach, investigate its structure on a small test system subject to congestion from uniform load growth, and demonstrate computational efficiency on a realistically-sized network.

25 ENERGY STORAGE↗

Plasma characterization of the superconducting proton linear accelerator plasma generator using a 2 MHz compensated Langmuir probe

The CERN study for a superconducting proton Linac (SPL) investigates the design of a pulsed 5 GeV Linac operating at 50 Hz. As a first step towards a future SPL H{sup -} volume ion source, a plasma generator capable of operating at Linac4 or nominal SPL settings has been developed and operated at a dedicated test stand. The hydrogen plasma is heated by an inductively coupled RF discharge e{sup -} and ions are confined by a magnetic multipole cusp field similar to the currently commissioned Linac4 H{sup -} ion source. Time-resolved measurements of the plasma potential, temperature, and electron energy distribution function obtained by means of a RF compensated Langmuir probe along the axis of the plasma generator are presented. The influence of the main tuning parameters, such as RF power and frequency and the timing scheme is discussed with the aim to correlate them to optimum H{sup -} ion beam parameters measured on an ion source test stand. The effects of hydrogen injection settings which allow operation at 50 Hz repetition rate are discussed.

43 PARTICLE ACCELERATORS↗

Constituent Components of Out-of-Field Scatter Dose for 18-MV Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy: A Comparison With 6-MV and Implications for Carcinogenesis

Purpose: To characterize and compare the components of out-of-field dose for 18-MV intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) and their 6-MV counterparts and consider implications for second cancer induction. Methods and Materials: Comparable plans for each technique/energy were delivered to a water phantom with a sloping wall; under full scatter conditions; with field edge abutting but outside the bath to prevent internal/phantom scatter; and with shielding below the linear accelerator head to attenuate head leakage. Neutron measurements were obtained from published studies. Results: Eighteen-megavolt IMRT produces 1.7 times more out-of-field scatter than 18-MV 3D-CRT. In absolute terms, however, differences are just approximately 0.1% of central axis dose. Eighteen-megavolt IMRT reduces internal/patient scatter by 13%, but collimator scatter (C) is 2.6 times greater than 18-MV 3D-CRT. Head leakage (L) is minimal. Increased out-of-field photon scatter from 18-MV IMRT carries out-of-field second cancer risks of approximately 0.2% over and above the 0.4% from 18-MV 3D-CRT. Greater photoneutron dose from 18-MV IMRT may result in further maximal, absolute increased risk to peripheral tissue of approximately 1.2% over 18-MV 3D-CRT. Out-of-field photon scatter remains comparable for the same modality irrespective of beam energy. Machine scatter (C+L) from 18 versus 6 MV is 1.2 times higher for IMRT and 1.8 times for 3D-CRT. It is 4 times higher for 6-MV IMRT versus 3D-CRT. Reduction in internal scatter with 18 MV versus 6 MV is 27% for 3D-CRT and 29% for IMRT. Compared with 6-MV 3D-CRT, 18-MV IMRT increases out-of-field second cancer risk by 0.2% from photons and adds 0.28-2.2% from neutrons. Conclusions: Out-of-field photon dose seems to be independent of beam energy for both techniques. Eighteen-megavolt IMRT increases out-of-field scatter 1.7-fold over 3D-CRT because of greater collimator scatter despite reducing internal/patient scatter. Out-of-field carcinogenic risk is thus increased (but improved in-field dose conformity may offset this). Potentially increased carcinogenic risk should be weighed against any benefit 18-MV IMRT may provide.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-beam linear accelerator EVT

A novel electron multi-beam accelerator is presented. The accelerator, short-named EVT (Electron Voltage Transformer) belongs to the class of two-beam accelerators. It combines an RF generator and essentially an accelerator within the same vacuum envelope. Drive beam-lets and an accelerated beam are modulated in RF modulators and then bunches pass into an accelerating structure, comprising uncoupled with each other and inductive tuned cavities, where the energy transfer from the drive beams to the accelerated beam occurs. A phasing of bunches is solved by choice correspond distances between gaps of the adjacent cavities. Preliminary results of numerical simulations and the initial specification of EVT operating in S-band, with a 60 kV gun and generating a 2.7 A, 1.1 MV beam at its output is presented. Furthermore, a relatively high efficiency of 67% and high design average power suggest that EVT can find its use in industrial applications.

43 PARTICLE ACCELERATORS↗

Combined experimental and numerical kinetic characterization of NR vulcanized with sulphur, N terbutyl, 2 benzothiazylsulphenamide and N,N diphenyl guanidine

The paper presents the final results of a comprehensive experimental and numerical analysis aimed at deeply investigating the behavior of Natural Rubber (NR) vulcanized with sulphur in presence of different accelerators during standard rheometer tests. NR in presence of sulphur and two different accelerators (DPG and TBBS) in various concentrations is investigated, changing the curing temperature in the range 150-180°C and obtaining rheometer curves with a step of 10°C. Sulphur-TBBS concentrations considered are 1-1, 1-3, 3-3 and 3-1, with DPG at 1-4 phr respectively. A total of 48 experimental rheometer curves is so obtained. To fit experimental data, the general reaction scheme proposed by Han and co-workers for vulcanized sulphur NR is re-adapted and suitably modified taking into account the single contributions of the different accelerators. Chain reactions initiated by the formation of macro-compounds responsible for the formation of the unmatured crosslinked polymer are accounted for. In presence of two accelerators, reactions are assumed to proceed in parallel, making the practically effective hypothesis that there is no interaction between the two accelerators. From the simplified kinetic scheme adopted, a closed form solution is found for the crosslink density, with the only limitation that the induction period is excluded from computations. For each experimented case on the same blend, reaction kinetic constants provided by the model are utilized to deduce their trend in the Arrhenius space, also outside the temperature range inspected. Rather close linearity is found in the majority of the cases. A comparative analysis is carefully conducted among the constants at the different concentrations of S, TBBS and DPG investigated, allowing a prediction of curing behavior at any vulcanization temperature and with concentrations not experimentally tested, without the need of addition costly experimentation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lowering Whole-Body Radiation Doses in Pediatric Intensity-Modulated Radiotherapy Through the Use of Unflattened Photon Beams;Flattening filter; Pediatric; Intensity-modulated radiotherapy; Second cancers; Radiation-induced malignancies

Purpose: Intensity modulated radiotherapy (IMRT) has been linked with an increased risk of secondary cancer induction due to the extra leakage radiation associated with delivery of these techniques. Removal of the flattening filter offers a simple way of reducing head leakage, and it may be possible to generate equivalent IMRT plans and to deliver these on a standard linear accelerator operating in unflattened mode. Methods and Materials: An Elekta Precise linear accelerator has been commissioned to operate in both conventional and unflattened modes (energy matched at 6 MV) and a direct comparison made between the treatment planning and delivery of pediatric intracranial treatments using both approaches. These plans have been evaluated and delivered to an anthropomorphic phantom. Results: Plans generated in unflattened mode are clinically identical to those for conventional IMRT but can be delivered with greatly reduced leakage radiation. Measurements in an anthropomorphic phantom at clinically relevant positions including the thyroid, lung, ovaries, and testes show an average reduction in peripheral doses of 23.7%, 29.9%, 64.9%, and 70.0%, respectively, for identical plan delivery compared to conventional IMRT. Conclusions: IMRT delivery in unflattened mode removes an unwanted and unnecessary source of scatter from the treatment head and lowers leakage doses by up to 70%, thereby reducing the risk of radiation-induced second cancers. Removal of the flattening filter is recommended for IMRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intercellular Adhesion Molecule-1 and Vascular Cell Adhesion Molecule Are Induced by Ionizing Radiation on Lymphatic Endothelium

Purpose/Objectives: The goal of this study was to assess the effects of ionizing radiation on the expression of the integrin ligands ICAM-1 and VCAM that control leucocyte transit by lymphatic endothelial cells. Materials/Methods: Confluent monolayers of primary human lymphatic endothelial cells (LEC) were irradiated with single dose of 2, 5, 10 or 20 Gy, with 6 MeV-x-rays using a Linear-Accelerator. ICAM-1 and VCAM expression was determined by flow cytometry. Human tissue specimens received a single dose of 20 Gy with 15 MeV-x-rays. MC38, B16-OVA or B16-VEGF-C tumors grown in C57BL/6 mice were irradiated with single dose of 20Gy using a Linear-Accelerator fitted with a 10mm Radiosurgery collimator. Clinical samples were obtained from patients previous and 4 weeks after complete standard radiotherapy. ICAM-1 and VCAM expression was detected in all tissue specimens by confocal microscopy. To understand the role of TGFβ in this process anti-TGFβ blocking mAb were injected i.p. 30min before radiotherapy. Cell adhesion to irradiated LEC was analyzed in adhesion experiments performed in the presence or in the absence of anti- TGFβ and /or anti-ICAM1 blocking mAb. Results: We demonstrate that lymphatic endothelial cells in tumor samples experience induction of surface ICAM-1 and VCAM when exposed to ionizing radiation in a dose- and time-dependent manner. These effects can be recapitulated in cultured LEC, and are in part mediated by TGFβ. These data are consistent with increases in ICAM-1 and VCAM expression on LYVE-1+ endothelial cells in freshly explanted human tumor tissue and in mouse transplanted tumors after radiotherapy. Finally, ICAM-1 and VCAM expression accounts for enhanced adherence of human T lymphocytes to irradiated LEC. Conclusion: Our results show induction of ICAM-1 and VCAM on LVs in irradiated lesions and offer a starting point for elucidating the biological and therapeutic implications of targeting leukocyte traffic in combination to immunotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of normoxic polymer gel using monomer 2-hydroxyethyl methacrylate (HEMA)

The aim of this study is to determine the sensitivity of HEMA-polymer gel mixture consist of monomer 2-hydroxyethyl methacrylate (HEMA) with different types of composition. Several composition of HEMA-polymer gel were fabricated and the gels were irradiated with radiation dose between 10 cGy to 100cGy by using x-ray machine and 100 cGy to 1400 cGy by using 6 MV photon beam energy of linear accelerator. The degree of polymerization was evaluated by using magnetic resonance imaging (MRI) with dependence of R2-dose response. Polymer gel consists of cross-linker, anti-oxidant Tetrakis(Hydroxymethyl)phosphonium chloride solution (THPC) and oxygen scavenger hydroquinone shows a stable sensitivity with highest dose dependency. Besides, the results shows the stage polymerization consist of induction, propagation, termination, and chain transfer were dependence with type of chemical mixture and radiation dose. Thus, normoxic HEMA-polymer gel with the different gel formulations can have a better dose resolution and an appropriate recipe must be selected to increase of the sensitivity required and the stability of the dosimeter.

36 MATERIALS SCIENCE↗