Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Electron emissions and hot spots in dual-phase LXe TPCs

Persistent photon and single-electron emissions - in the form of “electron trains” and localized “hot spots” - have been observed in multiple dual-phase liquid xenon (LXe) time projection chambers (TPCs), often persisting long after ionizing events. Here, we show that these phenomena are naturally explained by photon-triggered single-electron emission from resistive mixed-oxide films on stainless-steel (SS304 or s.s.) wires, which behave as leaky capacitors with long RC time constants at LXe temperature. Positive ions landing on these oxides can further enhance local fields and drive Malter-like electron emission. We outline the materials physics (Cr 2 O 3 /Cr 2 O 3-x /Cr(OH) 3 mosaics), quantify expected time scales (∼1 s under illumination), and demonstrate how small damaged regions with enhanced QE can produce persistent hot spots.

Va'vra, J. [SLAC National Accelerator Laboratory (↗

The CP-PAW Code Package for First-Principles Calculations from a User’s Perspective

CP-PAW is a combined electronic structure and ab initio molecular dynamics code to perform mixed quantum and classical simulations of atomistic condensed phase systems, such as solids, liquids, and molecular systems. As the name suggests, the CP-PAW code unifies the all-electron projector augmented-wave (PAW) method with the Car–Parrinello (CP) approach to determine not only the electronic and nuclear ground states of condensed matter but also to study their properties and dynamics. In addition to briefly outlining the underlying theory, the focus will be on the unique aspects of CP-PAW and how to correctly employ them as a user. How to install CP-PAW using the new build system will also be briefly mentioned.

Blöchl, Peter E [Institute for Theoretical Physic↗

Physical properties investigation of tetragonal Ba T 2 P 2 (T = Ru, Pd)

The structural, thermal, electrical transport, and magnetic properties of ternary compounds BaT 2 P 2 (T = Ru, Pd) are reported together with electronic structure calculations. Our results show that BaRu 2 P 2 crystallises in the layered tetragonal ThCr 2 Si 2 -type structure (space group I4/mmm) whereas BaPd 2 P 2 adopts the primitive tetragonal CeMg 2 Si 2 -type structure (space group P4/mmm). The combined experimental results and electronic structure calculations suggest metallic and diamagnetic ground states for both materials. Electrical transport measurements further indicate non-Fermi liquid behaviour at low temperatures. Notably, BaRu 2 P 2 exhibits an anomalous feature in the magnetic susceptibility at T ~ 260 K, similar to that observed in BaRu 2 As 2 . A comparison between the bare density of states obtained from electronic structure calculations and the experimentally estimated values suggests the presence of strong correlation effects in the material. Furthermore, the heat capacity of BaPd 2 P 2 , calculated using the full phonon dispersion relation, is in good agreement with the experimental data, particularly at low temperatures, highlighting the significant contribution of optical phonon branches to C P in this temperature range.

flat bands↗

Amino Acid Sequence Controls Enhanced Electron Transport in Heme-Binding Peptide Monolayers

Metal-binding proteins have the exceptional ability to facilitate long-range electron transport in nature. Despite recent progress, the sequence-structure–function relationships governing electron transport in heme-binding peptides and protein assemblies are not yet fully understood. In this work, the electronic properties of a series of heme-binding peptides inspired by cytochrome bc1 are studied using a combination of molecular electronics experiments, molecular modeling, and simulation. Self-assembled monolayers (SAMs) are prepared using sequence-defined heme-binding peptides capable of forming helical secondary structures. Following monolayer formation, the structural properties and chemical composition of assembled peptides are determined using atomic force microscopy and X-ray photoelectron spectroscopy, and the electronic properties (current density–voltage response) are characterized using a soft contact liquid metal electrode method based on eutectic gallium–indium alloys (EGaIn). Our results show a substantial 1000-fold increase in current density across SAM junctions upon addition of heme compared to identical peptide sequences in the absence of heme, while maintaining a constant junction thickness. These findings show that amino acid composition and sequence directly control enhancements in electron transport in heme-binding peptides. Overall, this study demonstrates the potential of using sequence-defined synthetic peptides inspired by nature as functional bioelectronic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of negative triangularity on microinstabilities in a low-recycling lithium-wall spherical tokamak

In this work, we present a linear gyrokinetic study of the impact of negative triangularity (NT) on microinstabilities in the Lithium Tokamak eXperiment-β (LTX-β), a low-recycling spherical tokamak with liquid lithium plasma-facing components that produce flat electron-temperature profiles [Elliott et al., IEEE Trans. Plasma Sci. 48, 1382 (2020)]. While NT is widely recognized as a stabilizing mechanism and often associated with improved confinement in conventional tokamaks, this study reveals that its effect is not universally stabilizing in the parameter regime of LTX-β and is shown to be highly sensitive to local equilibria. Using local linear simulations with the GS2 code [Kotschenreuther et al., Comput. Phys. Commun. 88, 128 (1995)] at ρ=0.3, 0.5, and 0.8 for two representative discharges (#103955 and #109355), and employing the Miller equilibrium model to isolate shaping effects, we find that NT can transition from stabilizing to destabilizing depending on magnetic shear, safety factor, and electron-temperature gradient. In shot #103955, NT reduces growth rates across radii, with strongest stabilization at the edge, whereas in shot #109355, it is stabilizing in the core but destabilizing at mid-radius and edge under experimental conditions. Parametric scans show that flattening the electron-temperature profile, increasing magnetic shear, and reducing the safety factor recover NT stabilization. These results demonstrate that NT stabilization is tunable rather than intrinsic and requires coordinated control of magnetic geometry and gradient drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

Large-scale real-time signal processing in physics experiments: the ALICE TPC FPGA pipeline

For LHC Run 3, the ALICE Time Projection Chamber was upgraded to operate in continuous readout mode. Interaction rates of up to 50 kHz in Pb-Pb collisions require real-time processing of more than 3 TB s -1 of raw detector data. This requirement is met by a custom FPGA-based processing pipeline that performs the complete front-end data treatment fully in-stream, including common-mode correction, pedestal subtraction, ion-tail filtering, zero suppression, and dense data packing. A central element of the design is a highly parallel common-mode correction algorithm operating directly on the streaming data. It robustly identifies signal-free readout channels on a time-bin basis and applies pad-dependent scaling to compensate for local variations in capacitive coupling in the GEM readout. In combination with pedestal subtraction and ion-tail filtering, this enables accurate baseline restoration under extreme high-occupancy conditions, preventing signal loss while efficiently suppressing noise prior to zero suppression. The pipeline operates continuously at the full detector bandwidth and reduces the raw input rate of approximately 3 TB s -1 to about 900 GBps for Pb-Pb collisions at the target interaction rate. Overall, it represents a large-scale FPGA-based real-time signal-processing implementation for high-energy physics detector readout.

Digital signal processing (DSP)↗

Speed of sound in methane under conditions of planetary interiors

We present direct observations of acoustic waves in warm dense matter. We analyze wave-number- and energy-resolved x-ray spectra taken from warm dense methane created by laser heating a cryogenic liquid jet. X-ray diffraction and inelastic free-electron scattering yield sample conditions of 0.3 ± 0.1 eV and 0.8 ± 0.1 g/ cm − 3 , corresponding to a pressure of ∼ 13 GPa. Inelastic x-ray scattering was used to observe the collective oscillations of the ions. With a highly improved energy resolution of ∼ 50 meV, we could clearly distinguish the Brillouin peaks from the quasielastic Rayleigh feature. Data at different wave numbers were utilized to derive a sound speed of 5.9 ± 0.5 km/s, marking a high-temperature data point for methane and demonstrating consistency with Birch's law in this parameter regime. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extending JuTrack’s capabilities to the FRIB accelerator to enhance online modeling

JuTrack is a Julia-based accelerator modeling and tracking package that utilizes compiler-level automatic differentiation (AD) to enable fast and accurate derivative calculations. While JuTrack provides a solid foundation for beam dynamics simulations, its capabilities must be extended to support the Facility for Rare Isotopes (FRIB) linac. This includes modeling heavy-ion linac accelerator components such as the liquid-lithium charge stripper, which facilitates efficient acceleration by remove electrons from heavy isotopes, and incorporating multi-charge state acceleration tracking, which allows for charge-dependent beam dynamics. These extensions address challenges such as the beam matching and optimization of multi charge state through various accelerating structures and beam-material interaction modeling while maintaining the auto differentiation capability. This work focuses on adapting JuTrack to incorporate these elements, enhancing its online modeling abilities. We present modifications to JuTrack’s framework and demonstrate their performance in FRIB simulations.

Accelerator Physics↗

Timing-Based Search for Magnetic Monopoles with the NOvA Detector on the Surface

We report a search for a magnetic monopole component of the cosmic-ray flux in a 2743-live-day exposure of the NOvA experiment's Far Detector, a 14 kt segmented liquid scintillator detector designed primarily to observe GeV-scale electron neutrinos. No events consistent with monopoles were observed, setting an upper limit on the flux of $8\times 10^{-16}~\mathrm{cm^{-2}s^{-1}sr^{-1}}$ at 90% C.L. for monopole speed $6\times 10^{-4} < β< 5\times 10^{-3}$ and mass greater than $10^{9}$ GeV. Because of NOvA's small overburden of 3 meters-water equivalent, this constraint covers a previously unexplored low-mass region.

Abubakar, S. [Erciyes U.]↗

Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD

DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.

Front-end electronics for detector readout↗

Atomic Structure, Dynamics, Changes in Chemical Bonding and Semiconductor-Metal Transition in Sb 2 Se 3 : A Remarkable Material for Quantum Networks and Energy Applications

Antimony sesquiselenide has become an outstanding functional material for photovoltaics, energy storage and transformation, memory and photonic applications. Sb 2 Se 3 is one of the most successful emerging solar light absorbers and has also been identified as a highly promising ultralow-loss phase-change material (PCM) for next-generation coherent nanophotonic processors, photonic tensor cores, quantum and neuromorphic networks. Unlike benchmark telluride PCMs, Sb 2 Se 3 features a quasi-one-dimensional (1D) crystalline structure consisting of (Sb 4 Se 6 ) ∞ ribbons, lacks the typical PCM chemical bonding, and undergoes an extended semiconductor-metal transition above the melting point. Consequently, the origin of high optical contrast between crystalline (SET) and amorphous (RESET) logic states remains elusive and presents a significant challenge. Using high-energy X-ray diffraction and Raman spectroscopy over a wide temperature range, supported by first-principles simulations and complemented by thermal, optical and electrical measurements, as well as by 121 Sb-Mossbauer spectroscopy, the quasi-1D network of orthorhombic antimony sesquiselenide was found to undergo significant evolution in amorphous and supercooled Sb 2 Se 3 , leading to lower coordination, shorter interatomic distances and a higher p-electron density on antimony, indicating changes in chemical bonding. The observed novel Sb 2 Se 3 nanocrystalline polymorph, characterized by trigonal antimony coordination and more isolated Sb-Se ribbons, could help reduce multiple trapping defect states in the bandgap, which are typical of orthorhombic Sb 2 Se 3 , thereby enhancing the power-conversion efficiency of photovoltaic devices. Semimetallic and metallic liquid Sb 2 Se 3 exhibit a gradual transformation into a denser 2D and/or 3D network with higher antimony coordination. Localized electron states in the pseudogap are becoming extended, leading to an increase in electronic conductivity σ following the relationship σ ∝ N(E F ) 2 . Liquid Sb 2 Se 3 also appears to be strongly fragile, with a nonmonotonic change in viscosity and higher atomic mobility in the metallic liquid. Furthermore, these results explain extraordinary functionalities of Sb 2 Se 3 for photonic and energy applications.

antimony↗

High power density compact drive integrated motor for electric transportation

This project, initially part of OPEN 2018, and subsequently the ASCEND effort, targeted demonstration of significant enhancements in internal permanent magnet (IPM) motor torque and power density for current and future ground and air electric transportation applications. These were achieved through: (1) embedded two-phase system thermal management, (2) coupled, multi-scale electrical-electromagnetic-thermal-mechanical co-design and optimization, (3) size and weight reduction of motor and drive electronics through elimination of redundant cooling and coupling hardware, and (4) higher efficiency operation of SiC wide bandgap power electronics packaging through high temperature operation (200 oC). The proposed approach utilizes a single dielectric coolant for closed loop two-phase thermal management, and a combined heat rejection unit for the IPM and drive. Wick assisted liquid delivery for evaporative thermal management is utilized for the motor, and the drive electronics utilize the same coolant in flow boiling within the cold plate structures. Through the use of three-dimensional packaging for SiC, and novel drive topologies with reduced switching losses, significant increases in power density and compactness were targeted.

33 ADVANCED PROPULSION SYSTEMS↗

MicroBooNE Electron-Neutrino Cross-Section Results

Measurement of the electron-neutrino cross-section with argon ($\nu$-Ar) is crucial for current and future neutrino experiments. Results from MicroBooNE detector, a liquid argon time projection chamber (LArTPC) based at Fermilab, provide the most extensive and precise determination of these electron-neutrino cross-sections. MicroBooNE is situated on both on-axis and off-axis beams: the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam, respectively. The background for both beams is dominated by showers from neutral pion decay, necessitating an electron-photon separation technique. In this proceeding, we review three recent electron-neutrino cross-section results from MicroBooNE using NuMI and BNB.

Guzzo, Marina [Edinburgh U.]↗

A search for Heavy Neutral Leptons with masses up to 150 MeV and studies on scintillation light detection in SBND

Introduction Neutrino physics is one of today’s most promising fields in particle physics. The discovery of neutrino oscillations is an evidence of their mass not being null. However, the Standard Model of elementary particles (SM) does not contain a mechanism that generates them, so we have to search beyond the SM to find answers. Other unknowns remain open, such as the amount of CP symmetry violated in the lepton sector that could help explain the differences between matter and antimatter that formed the present universe. Nor is it understood why these particles are so light, more than six orders of magnitude below the next fermion, the electron. A possible explana&#x2;tion is the existence of heavier neutrino mass states usually referred as heavy neutral leptons (HNLs). One of the most advanced technologies for detecting neutrino interactions is the liquid argon time projection chamber (LArTPC). LArTPC detectors form a 3D image of the ionized electrons in the interaction, producing a detailed description of each neutrino event. Argon is also a prolific scintillator (40k photons/MeV) with light signals indicat&#x2;ing the interaction time. The Short-Baseline Near Detector (SBND), a 112-active mass LArTPC at Fermilab, will measure millions of neutrino interactions from the Booster Neutrino Beam (BNB). As the near (L=110 m) detector of the Short-Baseline neutrino program, SBND will search for a fourth light neutrino (∼ eV) in the coming years. This hypothesis could explain the anomalous data observed in the LSND and MiniBooNE experiments.

Álvarez Garrote, Rodrigo [Madrid U.] (ORCID:000000↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗