Search NASA⌕ Search

SEARCH · Search NASA

Results for “load estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Estimating the Impacts of Direct Load Control Programs Using GridPIQ, a Web-Based Screening Tool

In direct load control (DLC) programs, utilities can curtail the demand of participating loads to contractually agreed-upon levels during periods of critical peak load, thereby reducing stress on the system, generation cost, and required transmission and generation capacity. Participating customers receive financial incentives. The impacts of implementing DLC programs extend well beyond peak shaving. There may be a shift of load proportional to the interrupted load to the times before or after a DLC event, and different load shifts have different consequences. Tools that can quantify the impacts of such programs on load curves, peak demand, emissions, and fossil fuel costs are currently lacking. The Grid Project Impact Quantification (GridPIQ) screening tool includes a Direct Load Control module, which takes into account project-specific inputs as well as the larger system context in order to quantify the impacts of a given DLC program. This allows users (utilities, researchers, etc.) to test and compare different program specifications and their impacts.

Demand Reponse↗

Design Update of the SSR1 Cryomodule for PIP-II Project

This paper reports the design update of the Single Spoke Resonator 1 (SSR1) cryomodule developed in the framework of PIP-II project at Fermilab. The most re-cent design changes and results of calculations per-formed to optimize the vacuum vessel, current leads, piping system and thermal shield are described. Then the estimated heat loads of the cryomodule leading to the sizing of the cryogenic valves will be presented.

43 PARTICLE ACCELERATORS↗

Summary of FY 2010 Iodine Capture Studies at the INL

Three breakthrough runs using silver mordenite sorbents were conducted and a dynamic sorption capacity estimated based on MeI analysis from a 2" bed. However, it is now believed the data for the first 2 runs is incomplete because the contributions from elemental iodine were not included. Although the only source of iodine was MeI, elemental iodine was generated within the sorbent bed, presumably from a recombination reaction likely catalyzed by silver mordenite. On-line effluent analysis with a GC was only capable of analyzing MeI, not I2. Scrub samples drawn during Run #3, which are specific for I2, show significant levels of I2 being emitted from a partially spent Ag-mordenite bed. By combining MeI and I2 analyses, a well defined total iodine breakthrough curve can be generated for Run #3. At the conclusion of Run #3 (IONEX Ag-900 was the sorbent) the effluent level from Bed 2 was approaching 70% of the feed concentration. The leading bed (Bed 1) had an estimated average loading of 66 mg I/g sorbent, Bed 2's was 52 mg I/g. The corresponding silver utilizations (assuming formation of AgI) were about 59% and 46%, respectively. The spent sorbents are being sent to Sandia National Laboratories for confirmatory analysis of iodine and silver utilization as well as source material for waste form development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Capacity Value of PV and Wind Generation in the NV Energy System

Calculation of photovoltaic (PV) and wind power capacity values is important for estimating additional load that can be served by new PV or wind installations in the electrical power system. It also is the basis for assigning capacity credit payments in systems with markets. Because of variability in solar and wind resources, PV and wind generation contribute to power system resource adequacy differently from conventional generation. Many different approaches to calculating PV and wind generation capacity values have been used by utilities and transmission operators. Using the NV Energy system as a study case, this report applies peak-period capacity factor (PPCF) and effective load carrying capability (ELCC) methods to calculate capacity values for renewable energy sources. We show the connection between the PPCF and ELCC methods in the process of deriving a simplified approach that approximates the ELCC method. This simplified approach does not require generation fleet data and provides the theoretical basis for a quick check on capacity value results of PV and wind generation. The diminishing return of capacity benefit as renewable generation increases is conveniently explained using the simplified capacity value approach.

capacity value↗

2012 Market Report on U.S. Wind Technologies in Distributed Applications

At the end of 2012, U.S. wind turbines in distributed applications reached a 10-year cumulative installed capacity of more than 812 MW from more than 69,000 units across all 50 states. In 2012 alone, nearly 3,800 wind turbines totaling 175 MW of distributed wind capacity were documented in 40 states and in the U.S. Virgin Islands, with 138 MW using utility-scale turbines (i.e., greater than 1 MW in size), 19 MW using mid-size turbines (i.e., 101 kW to 1 MW in size), and 18.4 MW using small turbines (i.e., up to 100 kW in size). Distributed wind is defined in terms of technology application based on a wind project’s location relative to end-use and power-distribution infrastructure, rather than on technology size or project size. Distributed wind systems are either connected on the customer side of the meter (to meet the onsite load) or directly to distribution or micro grids (to support grid operations or offset large loads nearby). Estimated capacity-weighted average costs for 2012 U.S. distributed wind installations was $\$$2,540/kW for utility-scale wind turbines, $\$$2,810/kW for mid-sized wind turbines, and $\$$6,960/kW for newly manufactured (domestic and imported) small wind turbines. An emerging trend observed in 2012 was an increased use of refurbished turbines. The estimated capacity-weighted average cost of refurbished small wind turbines installed in 2012 was $\$$4,080/kW. As a result of multiple projects using utility-scale turbines, Iowa deployed the most new overall distributed wind capacity, 37 MW, in 2012. Nevada deployed the most small wind capacity in 2012, with nearly 8 MW of small wind turbines installed in distributed applications. In the case of mid-size turbines, Ohio led all states in 2012 with 4.9 MW installed in distributed applications. State and federal policies and incentives continued to play a substantial role in the development of distributed wind projects. In 2012, U.S. Treasury Section 1603 payments and grants and loans from the U.S. Department of Agriculture’s Rural Energy for America Program were the main sources of federal funding for distributed wind projects. State and local funding varied across the country, from rebates to loans, tax credits, and other incentives. Reducing utility bills and hedging against potentially rising electricity rates remain drivers of distributed wind installations. In 2012, other drivers included taking advantage of the expiring U.S. Treasury Section 1603 program and a prosperous year for farmers. While 2012 saw a large addition of distributed wind capacity, considerable barriers and challenges remain, such as a weak domestic economy, inconsistent state incentives, and very competitive solar photovoltaic and natural gas prices. The industry remains committed to improving the distributed wind marketplace by advancing the third-party certification process and introducing alternative financing models, such as third-party power purchase agreements and lease-to-own agreements more typical in the solar photovoltaic market. Continued growth is expected in 2013.

distributed wind↗

Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar radiation on the stringing section, transmits the data to the Transmission Energy Management System, validates its integrity and passes it on to Oncor and ERCOT (Electric Reliability Council of Texas) respective system operations. The iDLR system is automatic and transparent to ERCOT System Operations, i.e., it operates in parallel with all other system status telemetry collected through Supervisory Control and Data Acquisition (SCADA) employed across the company.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure Learning and Statistical Estimation in Distribution Networks - Part II

Limited placement of real-time monitoring devices in the distribution grid, recent trends notwithstanding, has prevented the easy implementation of demand-response and other smart grid applications. Part I of this paper discusses the problem of learning the operational structure of the grid from nodal voltage measurements. In this work (Part II), the learning of the operational radial structure is coupled with the problem of estimating nodal consumption statistics and inferring the line parameters in the grid. Based on a Linear-Coupled(LC) approximation of AC power flows equations, polynomial time algorithms are designed to identify the structure and estimate nodal load characteristics and/or line parameters in the grid using the available nodal voltage measurements. Then the structure learning algorithm is extended to cases with missing data, where available observations are limited to a fraction of the grid nodes. The efficacy of the presented algorithms are demonstrated through simulations on several distribution test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

California GAMA Special Study: Excess Nitrogen and Methane in Noble Gas Samples

The most prominent constituent causing concern for drinking water resources in California is nitrate. Denitrification in the unsaturated zone and in groundwater naturally reduces nitrate concentrations, controls the fate of groundwater nitrate and determines the time scale over which changes in management practice will result in improvements in water quality. Quantifying denitrification is also important in estimating nutrient loading to groundwater through time. Measurements of dissolved nitrogen gas can detect and quantify saturated zone denitrification; and LLNL with GAMA funding has developed benchtop instrumentation to measure dissolved nitrogen in groundwater. This technique, membrane-inlet mass spectrometry (MIMS) requires the collection of an additional sample and is not routinely included in current GAMA water quality monitoring surveys. Incorporating dissolved nitrogen analysis into current water quality monitoring protocols without requiring an additional sample or separate analysis is the most cost-effective way to expand the database of dissolved nitrogen concentrations and document the prevalence of saturated-zone denitrification in California groundwater. The GAMA Priority Basin, Shallow Aquifer Assessment, and Special Study water quality monitoring programs routinely use dissolved noble gas and tritium analyses to constrain groundwater travel times and recharge. Noble gases are collected as a 10-mL water sample in a crimped copper tube and are analyzed by noble gas mass spectrometry (NGMS). Nitrogen, methane and carbon dioxide, can now also be measured in copper tubes and analyzed by the same LLNL NGMS system, which has been upgraded to allow such analyses. In the case of the GAMA Shallow Aquifer Assessment project, this will automatically provide dissolved nitrogen analyses at little or no incremental cost. A significant advantage of this technique is that archival copper tube noble gas samples can be analyzed using the technique. The dissolved nitrogen analyses – combined with nitrate analyses and the NGMS age information – will provide unique insight into nitrate sources, inputs, transport, and reaction rates.

54 ENVIRONMENTAL SCIENCES↗

Spatially Resolved Domicile Charging Demands for Light-, Medium-, and Heavy-Duty Electric Vehicles in Virginia

The use of plug-in electric vehicles (PEVs) and resulting grid impacts are likely to grow rapidly, and evaluation of optimal smart charge management and grid integration strategies is warranted now. Evaluating distribution grid impacts requires fine-grained models of PEV operations to estimate charging loads across diverse vehicles at high spatial resolution. We propose such a model and consider a high-electrification scenario in Richmond and Newport News, Virginia. Our framework considers four categories of vehicle that are amenable to early aggressive electrification: light-duty passenger vehicles (LDV), trucks and vans with a focus on delivery or other local operations, school buses, and transit buses. These vehicles have a relatively consistent domicile, reducing the need for public charging infrastructure rollout to electrify. We apply a recent LDV model and propose new models for each vocation of medium- and heavy-duty vehicle, leveraging telematics data. We demonstrate our framework in Virginia and find energy demands in the region may total 15 GWh day, with most consumed by LDV. However, considering power demand at high spatial resolution reveals a different trend: LDVs have relatively small peak loads at specific sites (peak site demand around 800 kW) compared to average and high demand medium- and heavy-duty vehicle charging sites (peak site demand around 6,000 kW at a transit bus depot, 1,500 kW at a local freight hub, and 1,000 kW at a school). Our framework yields insights on the relative impacts of each vocation and enables future work to tailor grid integration strategies to each vehicle category.

33 ADVANCED PROPULSION SYSTEMS↗

GEOMETRY, HEAT REMOVAL AND KINETICS SCOPING MODELS FOR HYDROGEN STORAGE SYSTEMS

It is recognized that detailed models of proposed hydrogen storage systems are essential to gain insight into the complex processes occurring during the charging and discharging processes. Such insight is an invaluable asset for both assessing the viability of a particular system and/or for improving its design. The detailed models, however, require time to develop and run. Clearly, it is much more efficient to begin a modeling effort with a good system design and to progress from that point. To facilitate this approach, it is useful to have simplified models that can quickly estimate optimal loading and discharge kinetics, effective hydrogen capacities, system dimensions and heat removal requirements. Parameters obtained from these models can then be input to the detailed models to obtain an accurate assessment of system performance that includes more complete integration of the physical processes. This report describes three scoping models that assess preliminary system design prior to invoking a more detailed finite element analysis. The three models address the kinetics, the scaling and heat removal parameters of the system, respectively. The kinetics model is used to evaluate the effect of temperature and hydrogen pressure on the loading and discharge kinetics. As part of the kinetics calculations, the model also determines the mass of stored hydrogen per mass of hydride (in a particular reference form). As such, the model can determine the optimal loading and discharge rates for a particular hydride and the maximum achievable loading (over an infinite period of time). The kinetics model developed with the Mathcad{reg_sign} solver, runs in a mater of seconds and can quickly be used to identify the optimal temperature and pressure for either the loading or discharge processes. The geometry scoping model is used to calculate the size of the system, the optimal placement of heat transfer elements, and the gravimetric and volumetric capacities for a particular geometric configuration and hydride. This scoping model is developed in Microsoft Excel{reg_sign} and inputs the mass of hydrogen to be stored, mass of stored hydrogen to mass of hydride (from the kinetics model), component densities, etc. The heat removal scoping model is used to calculate coolant flowrates, pressure drops and temperature increases over the length of the cooling channels. The model also calculates the convection heat transfer coefficient required to remove the heat of reaction associated with hydrogen uptake. The heat removal model inputs dimensions and the mass of hydrogen to be stored directly from the geometry scoping model. Additionally, the model inputs the heats of reaction, the thermal properties of the coolant and the time required to charge the bed.

08 HYDROGEN↗

Insecticide Exposures on Commercial Aircraft: A Literature Review and Screening Level Assessment

The objective of this project was to provide initial estimates of the relationship between insecticide use on passenger aircraft and exposure levels present in the cabin environment. The work was initially divided into three tasks including 1) a review of insecticide application practices in commercial aircraft, 2) exploratory measurements of insecticide concentrations in treated aircraft and 3) screening level exposure modeling. Task 1 gathered information that is needed to assess the time-concentration history of insecticides in the airline cabin. The literature review focused on application practices, information about the cabin environment and existing measurements of exposure concentrations following treatment. Information from the airlines was not available for estimating insecticide application rates in the U.S. domestic fleet or for understanding how frequently equipment rotate into domestic routes following insecticide treatment. However, the World Health Organization (WHO) recommends several methods for treating aircraft with insecticide. Although there is evidence that these WHO guidelines may not always be followed, and that practices vary by airline, destination, and/or applicator company, the guidelines in combination with information related to other indoor environments provides a plausible basis for estimating insecticide loading rates on aircraft. The review also found that while measurements of exposure concentrations following simulated aerosol applications are available, measurements following residual treatment of aircraft or applications in domestic aircraft are lacking. Task 2 focused on developing an approach to monitor exposure concentrations in aircraft using a combination of active and passive sampling methods. An existing active sampling approach was intended to provide data immediately following treatment while a passive sampler was developed to provide wider coverage of the fleet over longer sampling periods. The passive sampler, based on a thin-film polymer-coated glass design, was developed specifically for deployment in the airliner ventilation system for long-term unattended monitoring of insecticide loading in the aircraft. Because access was not available for either treated aircraft or treatment records during the course of this study, the development and calibration of the passive samplers was halted prior to completion. Continued development of a field ready passive sampler for insecticides in aircraft would require collaboration with the airline industry to finalize the method for deployment and calibration conditions for the sampler. The Task 3 screening level modeling assessment used a dynamic two-box mass balance model that includes treated surfaces and air to explore the time-concentration history of insecticides in the cabin. The model was parameterized using information gathered during the literature review and run for several different insecticide use scenarios. Chemical degradation or sequestration in the surface compartment and mass transfer from the surface to the air limit the rate at which insecticides are removed from the system. This rate limiting process can result in an accumulation of insecticide in the airliner cabin following repeated applications. The extent of accumulation is a function of the overall persistence of the chemical in the system and the amount of chemical applied during each treatment.

54 ENVIRONMENTAL SCIENCES↗

Northwest Open Automated Demand Response Technology Demonstration Project

Lawrence Berkeley National Laboratory (LBNL) and the Demand Response Research Center (DRRC) performed a technology demonstration and evaluation for Bonneville Power Administration (BPA) in Seattle City Light's (SCL) service territory. This report summarizes the process and results of deploying open automated demand response (OpenADR) in Seattle area with winter morning peaking commercial buildings. The field tests were designed to evaluate the feasibility of deploying fully automated demand response (DR) in four to six sites in the winter and the savings from various building systems. The project started in November of 2008 and lasted 6 months. The methodology for the study included site recruitment, control strategy development, automation system deployment and enhancements, and evaluation of sites participation in DR test events. LBNL subcontracted McKinstry and Akuacom for this project. McKinstry assisted with recruitment, site survey collection, strategy development and overall participant and control vendor management. Akuacom established a new server and enhanced its operations to allow for scheduling winter morning day-of and day-ahead events. Each site signed a Memorandum of Agreement with SCL. SCL offered each site $3,000 for agreeing to participate in the study and an additional $1,000 for each event they participated. Each facility and their control vendor worked with LBNL and McKinstry to select and implement control strategies for DR and developed their automation based on the existing Internet connectivity and building control system. Once the DR strategies were programmed, McKinstry commissioned them before actual test events. McKinstry worked with LBNL to identify control points that can be archived at each facility. For each site LBNL collected meter data and trend logs from the energy management and control system. The communication system allowed the sites to receive day-ahead as well as day-of DR test event signals. Measurement of DR was conducted using three different baseline models for estimation peak load reductions. One was three-in-ten baseline, which is based on the site electricity consumption from 7 am to 10 am for the three days with the highest consumption of the previous ten business days. The second model, the LBNL outside air temperature (OAT) regression baseline model, is based on OAT data and site electricity consumption from the previous ten days, adjusted using weather regressions from the fifteen-minute electric load data during each DR test event for each site. A third baseline that simply averages the available load data was used for sites less with less than 10 days of historical meter data. The evaluation also included surveying sites regarding any problems or issues that arose during the DR test events. Question covered occupant comfort, control issues and other potential problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Probability Distribution of Wind Turbine Planetary Bearing Loads (Poster)

Among the various causes of bearing damage and failure, metal fatigue of the rolling contact surface is the dominant failure mechanism. The fatigue life is associated with the load conditions under which wind turbines operate in the field. Therefore, it is important to understand the long-term distribution of the bearing loads under various environmental conditions. The National Renewable Energy Laboratory's 750-kW Gearbox Reliability Collaborative wind turbine is studied in this work. A decoupled analysis using several computer codes is carried out. The global aero-elastic simulations are performed using HAWC2. The time series of the drivetrain loads and motions from the global dynamic analysis are fed to a drivetrain model in SIMPACK. The time-varying internal pressure distribution along the raceway is obtained analytically. A series of probability distribution functions are then used to fit the long-term statistical distribution at different locations along raceways. The long-term distribution of the bearing raceway loads are estimated under different environmental conditions. Finally, the bearing fatigue lives are calculated.

17 WIND ENERGY↗

Paper #50 Preliminary Sizing of Active Magnetic Bearings for sCO2 Waste-Heat Recovery Application

The team of Southwest Research Institute (SwRI) and GE Vernova (GE) is executing a project developing conceptual designs of high-temperature active magnetic bearings (AMBs) for sCO2 machinery applications. The goals of the project are to develop conceptual designs for radial and thrust AMBs capable of operating in sCO2 environments up to 1000°F. A waste-heat recovery (WHR) application with hermetic machinery is used as a reference case to apply AMBs. This application was previously investigated to compare hermetic machinery enabled by process-lubricated bearings and high-speed motors/generators with traditional machinery configurations using oil-lubricated bearings, gearboxes, and grid-frequency electric machines. In this paper, AMBs are sized for the WHR application machinery. Load capacity estimates are made using first-principle-derived formulas that consider operation at elevated temperatures. Estimates of linearized AMB system coefficients are also made to aid future controller development. Rotor models are developed that account for AMB rotor geometry and housing space requirements. Rotordynamics studies are performed to identify reasonable target values for closed-loop AMB stiffness and closed-loop AMB damping. These target values will be used in future control studies.

Lipham, Robert↗

The Use of Statistically Based Rolling Supply Curves for Electricity Market Analysis: A Preliminary Look

In light of the changing electricity resource mixes across the United States, an important question in electricity modeling is how additions and retirements of generation, including additions in variable renewable energy (VRE) generation could impact markets by changing hourly wholesale energy prices. Instead of using resource-intensive production cost models (PCMs) or building and using simple generator supply curves, this analysis uses a 'top-down' approach based on regression analysis of hourly historical energy and load data to estimate the impact of supply changes on wholesale electricity prices, provided the changes are not so substantial that they fundamentally alter the market and dispatch-order driven behavior of non-retiring units. The rolling supply curve (RSC) method used in this report estimates the shape of the supply curve that fits historical hourly price and load data for given time intervals, such as two-weeks, and then repeats this on a rolling basis through the year. These supply curves can then be modified on an hourly basis to reflect the impact of generation retirements or additions, including VRE and then reapplied to the same load data to estimate the change in hourly electricity price. The choice of duration over which these RSCs are estimated has a significant impact on goodness of fit. For example, in PJM in 2015, moving from fitting one curve per year to 26 rolling two-week supply curves improves the standard error of the regression from 16 dollars/MWh to 6 dollars/MWh and the R-squared of the estimate from 0.48 to 0.76. We illustrate the potential use and value of the RSC method by estimating wholesale price effects under various generator retirement and addition scenarios, and we discuss potential limits of the technique, some of which are inherent. The ability to do this type of analysis is important to a wide range of market participants and other stakeholders, and it may have a role in complementing use of or providing calibrating insights to PCMs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimation of average burnup of damaged fuels loaded in Fukushima Dai-ichi reactors by using the {sup 134}Cs/{sup 137}Cs ratio method

Average burnup of damaged fuels loaded in Fukushima Dai-ichi reactors is estimated, using the {sup 134}Cs/{sup 137}Cs ratio method for measured radioactivities of {sup 134}Cs and {sup 137}Cs in contaminated soils within the range of 100 km from the Fukushima Dai-ichi nuclear power plants. As a result, the measured {sup 134}Cs/{sup 137}Cs ratio from the contaminated soil is 0.996{+-}0.07 as of March 11, 2011. Based on the {sup 134}Cs/{sup 137}Cs ratio method, the estimated burnup of damaged fuels is approximately 17.2{+-}1.5 [GWd/tHM]. It is noted that the numerical results of various calculation codes (SRAC2006/PIJ, SCALE6.0/TRITON, and MVP-BURN) are almost the same evaluation values of {sup 134}Cs/ {sup 137}Cs ratio with same evaluated nuclear data library (ENDF-B/VII.0). The void fraction effect in depletion calculation has a major impact on {sup 134}Cs/{sup 137}Cs ratio compared with the differences between JENDL-4.0 and ENDF-B/VII.0. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗