HST Super Lightweight Interchangeable Carrier (SLIC) Static Test

The HST Super Light Weight Interchangeable Carrier Static Test program calls for a total of 15 load cases with an average of 9 simultaneous push/pull locations per load case. This testing program represents the most complex static test ever attempted at Goddard Space Flight Center. Many unique multi-pull fixtures were designed to apply the simultaneous loading. Additionally, a total of 600 channels of data required processing for each loadcase. A total of 1100 separate strain gages were installed on SLIC. A team of 15 trained technicians were needed to apply test loads via mechanical hand pumps for several load cases. All 15 load cases were successfully conducted within 15 weeks. The ManTech team successfully tested all SLIC 1200 interface clips to the required testing loads. Several unique designs were needed to address testing challenges as loadline interference, Payload Safety, payload flexibility and opposing load applications.

Chambers, William V.↗

Dynamic Analysis of Geared Rotors by Finite Elements

A finite element model of a geared rotor system on flexible bearings has been developed. The model includes the rotary inertia of on shaft elements, the axial loading on shafts, flexibility and damping of bearings, material damping of shafts and the stiffness and the damping of gear mesh. The coupling between the torsional and transverse vibrations of gears were considered in the model. A constant mesh stiffness was assumed. The analysis procedure can be used for forced vibration analysis geared rotors by calculating the critical speeds and determining the response of any point on the shafts to mass unbalances, geometric eccentricities of gears, and displacement transmission error excitation at the mesh point. The dynamic mesh forces due to these excitations can also be calculated. The model has been applied to several systems for the demonstration of its accuracy and for studying the effect of bearing compliances on system dynamics.

Kahraman, A.↗

Attitude control systems for load relief of Saturn-class launch vehicles

The effectiveness of attitude control laws that are designed to reduce bending moment loads and improve the controllability of large Saturn class boosters is discussed. These laws are referred to as load relief control systems. The two factors are assessed by simulations of varying degrees of complexity, from 2-D rigid body to 6-D with flexible body. A load relief control system, nicknamed AGE, is selected as the most effective of the various proposed schemes. This system is compared with other load relief laws and with simple attitude control. Most nominal vehicles use attitude control laws since their goal is to stay on the flight path without regard to the induced loads.

Sharp, J.↗

Progress on Gust Load Alleviation Wind Tunnel Experiment and Aeroservoelastic Model Validation for a Flexible Wing with Variable Camber Continuous Trailing Edge Flap System

This paper discusses a wind tunnel experiment of active gust load alleviation of a flexible wing which took place at University of Washington (UW) in 2019. The experiment performed under a NASA SBIR contract with Scientific Systems Company, Inc (SSCI). The objective of the experiment is to demonstrate active controls of the Variable Camber Continuous Trailing Edge Flap (VCCTEF) system for gust load alleviation and real-time drag optimization. The wind tunnel model is a 8.2% sub-scale Common Research Model (CRM) wing. The wing structure is designed to provide a substantial degree of flexibility to represent that of a modern high-aspect ratio wing. Eight active control surfaces are employed in the VCCTEF. A new gust generator system was designed and installed by UW under a sub-contract with SSCI. The first test entry started in July 2019 and ended in September 2019. During this test entry, many significant issues were found with the hardware and software. The significant issues with the servos prevented the test objective from being completed. A follow-up second test entry in 2020 is being planned. The wing system is being repaired by SSCI. This paper reports on the progress of this experimental effort and the aeroservoelastic (ASE) model validation which was conducted during the test entry.

Nguyen, Nhan↗

Flexible operation of nuclear hybrid energy systems for load following and water desalination

Nuclear hybrid energy systems (NHES) have the potential to provide dependable and emission-free electricity to the grid while also increasing the flexibility and reliability of the electrical grid. Molten salt reactor (MSR) technology can provide consistent, carbon-free electricity while also increasing efficiency, security, and sustainability and reducing nuclear waste. This study investigates the integration of Molten Salt Reactors (MSR) and conventional Pressurized Water Reactors (PWR) with desalination technologies: Direct Contact Membrane Distillation (DCMD), Multi-Stage Flash Distillation (MSFD), and Reverse Osmosis (RO). Dynamic first-principles models were developed and tested using real grid data from the New York Independent System Operator. The results demonstrate that nuclear power is capable of flexibly responding to changing grid demand while simultaneously producing clean water, particularly during periods of low electricity demand. The MSR-RO system was found to be the most efficient in electricity generation and water production, and all hybrid systems reduced CO2 emissions by 356,000 to 682,000 tons annually. Economic analysis reveals that nuclear desalination technologies are cost-competitive with conventional systems, especially when paired with RO. Finally, these findings confirm the technical feasibility and environmental benefits of nuclear hybrid systems for sustainable electricity and water production.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limiting vibration in systems with constant amplitude actuators through command preshaping

The basic concepts of command preshaping were taken and adapted to the framework of systems with constant amplitude (on-off) actuators. In this context, pulse sequences were developed which help to attenuate vibration in flexible systems with high robustness to errors in frequency identification. Sequences containing impulses of different magnitudes were approximated by sequences containing pulses of different durations. The effects of variation in pulse width on this approximation were examined. Sequences capable of minimizing loads induced in flexible systems during execution of commands were also investigated. The usefulness of these techniques in real-world situations was verified by application to a high fidelity simulation of the space shuttle. Results showed that constant amplitude preshaping techniques offer a substantial improvement in vibration reduction over both the standard and upgraded shuttle control methods and may be mission enabling for use of the shuttle with extremely massive payloads.

Rogers, Keith Eric↗

Phase Synchronization and Desynchronization of Structural Response Induced by Turbulent and External Sound

Acoustic and turbulent boundary layer flow loadings over a flexible structure are used to study the spatial-temporal dynamics of the response of the structure. The stability of the spatial synchronization and desynchronization by an active external force is investigated with an array of coupled transducers on the structure. In the synchronous state, the structural phase is locked, which leads to the formation of spatial patterns while the amplitude peaks exhibit chaotic behaviors. Large amplitude, spatially symmetric loading is superimposed on broadband, but in the desynchronized state, the spectrum broadens and the phase space is lost. The resulting pattern bears a striking resemblance to phase turbulence. The transition is achieved by using a low power external actuator to trigger broadband behaviors from the knowledge of the external acoustic load inducing synchronization. The changes are made favorably and efficiently to alter the frequency distribution of power, not the total power level. Before synchronization effects are seen, the panel response to the turbulent boundary layer loading is discontinuously spatio-temporally correlated. The stability develops from different competing wavelengths; the spatial scale is significantly shorter than when forced with the superimposed external sound. When the external sound level decreases and the synchronized phases are lost, changes in the character of the spectra can be linked to the occurrence of spatial phase transition. These changes can develop broadband response. Synchronized responses of fuselage structure panels have been observed in subsonic and supersonic aircraft; results from two flights tests are discussed.

Maestrello, Lucio↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.

03 NATURAL GAS↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

Soltis, James V.↗

Flexible Nuclear-Based Integrated Energy System

Presentation on a conceptual study of combining a small modular nuclear reactor (SMR) with a solid oxide fuel cell, solid oxide electrolysis cell, and a gas turbine as an integrated energy system with high operational flexibility and rapid load following. Virtually presented at the MILLENNIUM CLEAN and SUSTAINABLE POWER workshop 2025, University of Genoa, Italy.

flexibility↗

An Integrated Paradigm for the Management of Delivery Risk in Electricity Markets: From Batteries to Insurance and Beyond

If power systems transition to integrate higher amounts of variable renewable energy sources, storage technologies, and distributed energy resources (DERs), new risk management frameworks are necessary to ensure cost-effective and reliable power system operations. Projects funded by the Advanced Research Projects Agency-Energy (ARPA-E) Performance-based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) program aim to contribute new risk management frameworks by developing methods to quantify and manage risk at grid asset and system levels. The National Renewable Energy Laboratory (NREL) led a PERFORM project in collaboration with the Johns Hopkins University, the Electric Power Research Institute (EPRI), kWh Analytics, Packetized Energy, and Imperial Consultants (ICON). The project addressed two challenges related to risk management in electricity markets: managing net load imbalances and flexibility from DERs. This final technical report presents a list of project accomplishments, activities, and outputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The ATS-6 power system - An optimized design for maximum power source utilization

The modified power system design adopted for the ATS-6 satellite is described. This design featured a shunt-boost configuration to provide direct power from the solar array to the loads for maximum efficiency. In addition, shunt power dissipators were used, not only as a means of power system regulation, but also for thermal control. A brief description of the spacecraft and of the initial series regulator power system design (which was unable to meet mission requirements) precede the discussion. The shunt boost system provides excellent utilization of array power with an 8 to 10% increase in efficiency over the original configuration; good array-battery static and dynamic load sharing; excellent flexibility in accommodating mission requirements; and low electromagnetic interference.

Lavigna, T. A.↗

Qualitative comparison of calculated turbulence responses with wind-tunnel measurements for a DC-10 derivative wing with an active control system

Comparisons are presented analytically predicted and experimental turbulence responses of a wind tunnel model of a DC-10 derivative wing equipped with an active control system. The active control system was designed for the purpose of flutter suppression, but it had additional benefit of alleviating gust loads (wing bending moment) by about 25%. Comparisions of various wing responses are presented for variations in active control system parameters and tunnel speed. The analytical turbulence responses were obtained using DYLOFLEX, a computer program for dynamic loads analyses of flexible airplanes with active controls. In general, the analytical predictions agreed reasonably well with the experimental data.

Perry, B., III↗

Qualitative comparison of calculated turbulence responses with wind-tunnel measurements for a DC-10 derivative wing with an active control system

This paper presents comparisons of analytically-predicted and experimental turbulence responses of a wind-tunnel model of a DC-10 derivative wing equipped with an active control system. The active control system was designed for the purpose of flutter suppression, but it had the additional benefit of alleviating gust loads (wing bending moment) by about 25 percent. Comparisons of various wing responses are presented for variations in active-control-system parameters and tunnel speed. The analytical turbulence responses were obtained using DYLOFLEX, a computer program for dynamic loads analyses of flexible airplanes with active controls. In general, the analytical predictions agreed reasonably well with the experimental data.

Perry, B., III↗

Quasi-static solution algorithms for kinematically/materially nonlinear thermomechanical problems

This paper develops an algorithmic solution strategy which allows the handling of positive/indefinite stiffness characteristics associated with the pre- and post-buckling of structures subject to complex thermomechanical loading fields. The flexibility of the procedure is such that it can be applied to both finite difference and element-type simulations. Due to the generality of the algorithmic approach developed, both kinematic and thermal/mechanical type material nonlinearity including inelastic effects can be treated. This includes the possibility of handling completely general thermomechanical boundary conditions. To demonstrate the scheme, the results of several benchmark problems is presented.

Padovan, J.↗