Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An Update on the Status of a Reduced Flow Test of a 10MW 700°C sCO2 Integrally Geared Compander

. In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 degrees Celsius. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale concentrated solar power (CSP) supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications. As part of the commercialization of this technology, it is necessary to reduce risk by validation testing of key components. In the current work, the focus is developing a test loop to enable safe testing of the main compressor stage across a wide range of operating conditions, and to validate the mechanical integrity of the turbine at full pressure, temperature, and speed. Developing a test loop for sCO2 requires balancing a number of design alternatives that impact cost, lead time, safety, and performance. The current work discusses the design process for the reduced flow test loop for the compander, and supporting documentation supporting the viability of the test loop

wilkes, jason↗

FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide

A small liquid fluoride salt test apparatus has been constructed and testing conducted to examine the compatibility of SiC, Inconel 600, and a spiral wound gasket material in FLiNaK salt. These tests were conducted to test materials and sealing systems that would be used in a FLiNaK salt test loop. Three months of testing at 700oC was used to assure that these materials and seals would be acceptable operating under expected test loop conditions. The SiC specimens showed little or no change over the test period while the spiral wound gasket material showed no degradation, except for the possibility of salt seeping into the outermost spirals of the gasket. The Inconel 600 specimens showed regions of voiding which penetrated the specimen surface to about 250 m in depth. Analysis indicated that the salt had leached chrome from the Inconel surface as was expected for this material. Because the test loop will have a limited working lifetime, it was concluded that these materials would be satisfactory for loop construction.

42 ENGINEERING↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Development of a Thin Film Primary Surface Heat Exchanger for Advanced Power Cycles

This project objective is to develop a high-temperature design upgrade for an existing primary surface heat exchanger so that the redesigned hardware is capable of operation in CO 2 at temperatures up to 1,510°F (821°C) and pressure differentials up to 130 psi (9 bar). The heat exchanger is proposed for use as a recuperator in an advanced low-pressure oxy-fuel Brayton cycle that is predicted to achieve over 50% thermodynamic efficiency, although the heat exchanger could also be used in other high-temperature, low-differential pressure cycles. This report describes the progress to date, which includes continuing work performed to select and test new candidate materials for the recuperator redesign, final mechanical and thermal performance analysis results of various redesign concepts, and the preliminary design of a test loop for the redesigned recuperator including a budgetary estimate for detailed test loop design, procurement, and test operation. A materials search was performed in order to investigate high-temperature properties of many candidate materials, including high-temperature strength and nickel content. These properties were used to rank the candidate materials, resulting in a reduced list of nine materials for corrosion testing. Multiple test rigs were considered and analyzed for short-term corrosion testing and Thermal Gravimetric Analysis (TGA) was selected as the most cost-effective option for evaluating corrosion resistance of the candidate materials. In addition, tantalum, niobium, and chromium coatings were identified as potential options for increased corrosion resistance. The test results show that many materials exhibit relatively low weight gain rates, and that niobium and tantalum coatings may improve corrosion resistance for many materials, while chromium coatings appear to oxidize and debond quickly. Metallurgical analysis of alloys was also performed, showing evidence of intergranular attack in 282 that may cause long-term reliability problems in CO 2 service at these temperatures. However, long-term testing in a flowing environment is recommended in order to understand accurately the severity of the attack. Detailed economic modeling of the existing air cycle recuperator and CO 2 cycle recuperator options was also completed, including costs for material, fabrication, fuel, maintenance, and operation. The analysis results show that the increased capital cost for high-temperature materials may be offset by higher cycle efficiencies, decreasing the overall lifetime cost of the system. The economic analysis also examines costs associated with increased pressure drop and material changes for two redesign options. These results show that, even with slightly reduced performance and/or higher material costs, the lifetime cost per energy production may still be reduced by over 12%. The existing recuperator design information was provided by Solar Turbines, Inc. via several models, drawings, and design handoff meetings. Multiple fluid/thermal and structural models were created in order to analyze critical recuperator performance and mechanical strength in critical areas throughout the redesign process. These models were analyzed for a baseline condition (consistent with current Mercury 50 operation) for validation purposes. Results are presented for heat transfer coefficients and pressure drops, matching well with the existing operational data. Simulation of higher-temperature CO 2 conditions was also performed, showing a slight expected increase in both heat transfer and pressure drop. Mechanical analysis results for critical areas on the cross-flow and counter-flow sheets have also been obtained for air and CO 2 cases. These results show similar stresses in both cases but significantly reduced safety factors for the CO 2 case due to reduced yield and creep rupture strengths of alloy 625 at the higher temperatures. A concept brainstorm session and initial down-selection were completed in order to identify promising redesign options for further analysis. Detailed analysis of all promising redesign options was performed via finite element and computational fluid dynamic simulations in order to characterize mechanical and thermal-fluid performance of each option. These options included material change, various sheet thickness configurations, pitch and phasing of cross-flow and counter-flow sheets, and separator sheets. The analysis results have identified two viable redesign options that maintain existing safety margins optimally through a material change to Haynes 282 and (A) sheet thickness increases of 40% on the counter-flow sheet and 75% on the hot side cross-flow corrugation sheet or (B) addition of a separator sheet in the counter-flow section while maintaining the original counter-flow sheet thickness and increasing the cross-flow corrugation sheet thickness by 90% to account for the increase in cell height. While both options satisfy mechanical stress constraints, the separator sheet design has a higher part count, slightly reduced heat transfer, and slightly higher pressure drop than the first option and is not preferred. Finally, several test loop concepts have been developed for different full-scale and reduced-scale recuperator testing options. For each option, various loop components, such as heat exchangers, valves, heaters, and compressors, were evaluated in an effort to maximize utilization of existing resources. All concepts utilize an existing 3-MW CO 2 compressor, heater, and loop coolers, but the concepts vary by incorporating different amounts of new equipment for achieving various flow rates (all concepts operate at design pressure and temperature). The third concept achieves a 1 kg/s test without purchasing any costly equipment (coolers, heaters, blowers, etc.). Since the stacked cell design of the recuperator results in the same flow conditions at each core cell (even for a reduced-scale test). Thus, test loop Concept #3 was selected for the preliminary design. This loop design is detailed within the report, culminating in a budgetary estimate of $1,013,000.00 for the detailed design, construction, commissioning, and operation of a high-temperature recuperator test loop.

03 NATURAL GAS↗

50-kWth methane/air chemical looping combustion tests with commercially prepared CuO-Fe 2 O 3 -alumina oxygen carrier with two different techniques

CuO-Fe 2 O 3 /alumina oxygen carriers were manufactured using two different techniques (i.e., spray drying and wet granulation). The spray drying method produced porous, spherical particles in the range of 100–200 µm. The wet granulation, or tumbling method, produced particles in the range of 200–600 µm. Both batches of material showed good gas conversion and particle durability during tests in NETL’s 50-kWth chemical looping circulating fluidized bed combustor unit at 700–900 °C. No agglomeration was observed, even though the oxygen carrier had a high CuO concentration (30%). The particle losses with 200–600 µm batch were significantly lower than that with the 100–200 µm batch. The oxygen carrier materials in the 200–600 µm range were circulated for approximately 3.1 days in the target temperature range (700–850 °C) and a total of approximately 40 h of chemical looping combustion testing was conducted during that time. The average fuel reactor temperatures ranged from 760 to 815 °C for the chemical looping combustion test periods, and the average air reactor temperature ranged from 840 to 915 °C. The fuel conversion from natural gas to CO 2 ranged from 50 to 80%. Approximately 1.6 h of continuous operation was achieved with no gas preheat and no natural gas augmented heating. During this test period, the average fuel reactor temperature ranged from 780 to 825 °C, the air reactor temperature ranged from 930 to 960 °C, and the natural gas to CO 2 conversion ranged from 50 to 65%. Finally, analysis of the oxygen carrier after the test indicated that there were no significant changes in the particle size or the surface morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A study of two-phase flow in a reduced gravity environment

A test loop was designed and fabricated for observing and measuring pressure drops of two-phase flow in reduced gravity. The portable flow test loop was then tested aboard the NASA-JSC KC135 reduced gravity aircraft. The test loop employed the Sundstrand Two-Phase Thermal Management System (TPTMS) concept which was specially fitted with a clear two-phase return line and condenser cover for flow observation. A two-phase (liquid/vapor) mixture was produced by pumping nearly saturated liquid through an evaporator and adding heat via electric heaters. The quality of the two-phase flow was varied by changing the evaporator heat load. The test loop was operated on the ground before and after the KC135 flight tests to create a one-gravity data base. The ground testing included all the test points run during the reduced gravity testing. Two days of reduced gravity tests aboard the KC135 were performed. During the flight tests, reduced-gravity, one-gravity, and nearly two-gravity accelerations were experienced. Data was taken during the entire flight which provided flow regime and pressure drop data for the three operating conditions. The test results show that two-phase pressure drops and flow regimes can be accurately predicted in zero-gravity.

Hill, D.↗

Development of nuclear fuels and materials for propulsion systems for SEI

A panel was organized by NASA/DOE/DOD to study nuclear fuels, materials, and related nuclear propulsion technologies for SEI, and the panel findings are discussed. The fuels/materials requirements for nuclear thermal propulsion and nuclear electric propulsions are reviewed, and the development items such as 'element' development and characterization, fabrication process development, nuclear capsule tests, nuclear loop tests, and nuclear furnace tests are examined for selected classes of fuels.

Bhattacharyya, S. K.↗

Space Suit Portable Life Support System (PLSS) 2.0 Human-in-the-Loop (HITL) Testing

The space suit Portable Life Support System (PLSS) 2.0 represents the second integrated prototype developed and tested to mature a design that uses advanced technologies to reduce consumables, improve robustness, and provide additional capabilities over the current state of the art. PLSS 2.0 was developed in 2012, with extensive functional evaluations and system performance testing through mid-2014. In late 2014, PLSS 2.0 was integrated with the Mark III space suit in an ambient laboratory environment to facilitate manned testing, designated PLSS 2.0 Human-in-the-Loop (HITL) testing, in which the PLSS prototype performed the primary life support functions, including suit pressure regulation, ventilation, carbon dioxide control, and cooling of the test subject and PLSS avionics. The intent of this testing was to obtain subjective test subject feedback regarding qualitative aspects of PLSS 2.0 performance such as thermal comfort, sounds, smells, and suit pressure fluctuations due to the cycling carbon dioxide removal system, as well as to collect PLSS performance data over a range of human metabolic rates from 500-3000 Btu/hr. Between October 27 and December 18, 2014, nineteen two-hour simulated EVA test points were conducted in which suited test subjects walked on a treadmill to achieve a target metabolic rate. Six test subjects simulated nominal and emergency EVA conditions with varied test parameters including metabolic rate profile, carbon dioxide removal control mode, cooling water temperature, and Liquid Cooling and Ventilation Garment (state of the art or prototype). The nineteen test points achieved more than 60 hours of test time, with 36 hours accounting for simulated EVA time. The PLSS 2.0 test article performed nominally throughout the test series, confirming design intentions for the advanced PLSS. Test subjects' subjective feedback provided valuable insight into thermal comfort and perceptions of suit pressure fluctuations that will influence future advanced PLSS design and testing strategies.

Watts, Carly↗

Space Suit Portable Life Support System (PLSS) 2.0 Human-in-the-Loop (HITL) Testing

The space suit Portable Life Support System (PLSS) 2.0 represents the second integrated prototype developed and tested to mature a design that uses advanced technologies to reduce consumables, improve robustness, and provide additional capabilities over the current state of the art. PLSS 2.0 was developed in 2012, with extensive functional evaluations and system performance testing through mid-2014. In late 2014, PLSS 2.0 was integrated with the Mark III space suit in an ambient laboratory environment to facilitate manned testing, designated PLSS 2.0 Human-in-the-Loop (HITL) testing, in which the PLSS prototype performed the primary life support functions, including suit pressure regulation, ventilation, carbon dioxide control, and cooling of the test subject and PLSS avionics. The intent of this testing was to obtain subjective test subject feedback regarding qualitative aspects of PLSS 2.0 performance such as thermal comfort, sounds, smells, and suit pressure fluctuations due to the cycling carbon dioxide removal system, as well as to collect PLSS performance data over a range of human metabolic rates from 500-3000 Btu/hr. Between October 27 and December 18, 2014, nineteen two-hour simulated EVA test points were conducted in which suited test subjects walked on a treadmill to achieve a target metabolic rate. Six test subjects simulated nominal and emergency EVA conditions with varied test parameters including metabolic rate profile, carbon dioxide removal control mode, cooling water temperature, and Liquid Cooling and Ventilation Garment (state of the art or prototype). The nineteen test points achieved more than 60 hours of test time, with 36 hours accounting for simulated EVA time. The PLSS 2.0 test article performed nominally throughout the test series, confirming design intentions for the advanced PLSS. Test subjects' subjective feedback provided valuable insight into thermal comfort and perceptions of suit pressure fluctuations that will influence future advanced PLSS design and testing strategies.

Watts, Carly↗

Testing and Modeling of Subscale Ice-on-Coil Module as Low Temperature Reservoir for sCO2 based Pumped Thermal Energy Storage Systems

Echogen tested approximately 10 kWthsubscale IOC system in their lab in Akron, OH for studying the feasibility, endurance and performance impact of the technology on PTES system. This paper discusses the test loop setup, testing and results from this sub-scale IOC testing. Along with testing, the project team also developed sub-scale IOC transient model. The paper discusses this transient model development and its validation against the test data.

Avadhanula, Vamshi Krishna [Echogen Power Systems ↗

Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication on the flow mode, and a visualization of the radial material distribution can be obtained. A benefit of this system is its potential to be mounted at any axial height of a two-phase test section without requirements for pre-fabricated entrances or windows. This could mean a significant increase in flexibility of the void distribution assessment capability at many existing two-phase test loops.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of Critical Heat Flux and Two-Phase Pressure Drop Under Reduced Gravity

The design of the two-phase flow systems which are anticipated to be utilized in future spacecraft thermal management systems requires a knowledge of two-phase flow and heat transfer phenomena in reduced gravities. This program was funded by NASA headquarters in response to NRA-91-OSSA-17 and was managed by Lewis Research Center. The main objective of this program was to design and construct a two-phase test loop, and perform a series of normal gravity and aircraft trajectory experiments to study the effect of gravity on the Critical Heat Flux (CHF) and onset of instability. The test loop was packaged on two aircraft racks and was also instrumented to generate data for two-phase pressure drop. The normal gravity tests were performed with vertical up and downflow configurations to bound the effect of gravity on the test parameters. One set of aircraft trajectory tests was performed aboard the NASA DC-9 aircraft. These tests were mainly intended to evaluate the test loop and its operational performance under actual reduced gravity conditions, and to produce preliminary data for the test parameters. The test results were used to demonstrate the applicability of the normal gravity models for prediction of the two-phase friction pressure drop. It was shown that the two-phase friction multipliers for vertical upflow and reduced gravity conditions can be successfully predicted by the appropriate normal gravity models. Limited critical heat flux data showed that the measured CHF under reduced gravities are of the same order of magnitude as the test results with vertical upflow configuration. A simplified correlation was only successful in predicting the measured CHF for low flow rates. Instability tests with vertical upflow showed that flow becomes unstable and critical heat flux occurs at smaller powers when a parallel flow path exists. However, downflow tests and a single reduced gravity instability experiment indicated that the system actually became more stable with a parallel single-phase flow path. Several design modifications have been identified which will improve the system performance for generating reduced gravity data. The modified test loop can provide two-phase flow data for a range of operating conditions and can serve as a test bed for component evaluation.

Abdollahian, Davood↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

Open-Loop Flight Testing of COBALT GN&C Technologies for Precise Soft Landing

A terrestrial, open-loop (OL) flight test campaign of the NASA COBALT (CoOperative Blending of Autonomous Landing Technologies) platform was conducted onboard the Masten Xodiac suborbital rocket testbed, with support through the NASA Advanced Exploration Systems (AES), Game Changing Development (GCD), and Flight Opportunities (FO) Programs. The COBALT platform integrates NASA Guidance, Navigation and Control (GN&C) sensing technologies for autonomous, precise soft landing, including the Navigation Doppler Lidar (NDL) velocity and range sensor and the Lander Vision System (LVS) Terrain Relative Navigation (TRN) system. A specialized navigation filter running onboard COBALT fuzes the NDL and LVS data in real time to produce a precise navigation solution that is independent of the Global Positioning System (GPS) and suitable for future, autonomous planetary landing systems. The OL campaign tested COBALT as a passive payload, with COBALT data collection and filter execution, but with the Xodiac vehicle Guidance and Control (G&C) loops closed on a Masten GPS-based navigation solution. The OL test was performed as a risk reduction activity in preparation for an upcoming 2017 closed-loop (CL) flight campaign in which Xodiac G&C will act on the COBALT navigation solution and the GPS-based navigation will serve only as a backup monitor.

Carson, John M., III↗