Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ensemble Kalman filters for dynamical systems with unresolved turbulence

Ensemble Kalman filters are developed for turbulent dynamical systems where the forecast model does not resolve all the active scales of motion. Coarse-resolution models are intended to predict the large-scale part of the true dynamics, but observations invariably include contributions from both the resolved large scales and the unresolved small scales. The error due to the contribution of unresolved scales to the observations, called ‘representation’ or ‘representativeness’ error, is often included as part of the observation error, in addition to the raw measurement error, when estimating the large-scale part of the system. It is here shown how stochastic superparameterization (a multiscale method for subgridscale parameterization) can be used to provide estimates of the statistics of the unresolved scales. In addition, a new framework is developed wherein small-scale statistics can be used to estimate both the resolved and unresolved components of the solution. The one-dimensional test problem from dispersive wave turbulence used here is computationally tractable yet is particularly difficult for filtering because of the non-Gaussian extreme event statistics and substantial small scale turbulence: a shallow energy spectrum proportional to k{sup −5/6} (where k is the wavenumber) results in two-thirds of the climatological variance being carried by the unresolved small scales. Because the unresolved scales contain so much energy, filters that ignore the representation error fail utterly to provide meaningful estimates of the system state. Inclusion of a time-independent climatological estimate of the representation error in a standard framework leads to inaccurate estimates of the large-scale part of the signal; accurate estimates of the large scales are only achieved by using stochastic superparameterization to provide evolving, large-scale dependent predictions of the small-scale statistics. Again, because the unresolved scales contain so much energy, even an accurate estimate of the large-scale part of the system does not provide an accurate estimate of the true state. By providing simultaneous estimates of both the large- and small-scale parts of the solution, the new framework is able to provide accurate estimates of the true system state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Hierarchical Multi-Agent Based Anomaly Detection for Wide-Area Protection in Smart Grid

Future smart grid capabilities provide assurance to expand the advanced information and communication technologies to evolve into densely interconnected cyber physical system. Remedial Action Scheme (RAS), widely used for wide-area protection, relies on the interconnected networks and data sharing devices, which are exposed to the multitude of vulnerabilities. This paper presents our proposed approach to developing multi-agent based RAS scheme against the system-aware stealthy cyber-attacks. Specifically, we propose the two-level hierarchical architecture which consists of distributed local RAS controllers (RAScs) as local agents, operating at different zones/ areas, which are constantly monitored by an overseer, the central agent. The local controllers receive local and randomly changing outside zonal measurements and cyclically forwards to the overseer. The overseer identifies the corrupted controller using the anomaly detection algorithm which processes the measurements coming from the local controllers, compute measurement errors using local and outside zonal measurements, perform validation checks, and finally detect anomalies based on the two-step verification. Next, as a proof of concept, we have implemented and validated the proposed methodology in cyber physical environment at Iowa State’s PowerCyber testbed. We have also implemented the coordinated attack vectors which involve corrupting the local controller and later performing stealthy attacks on the system’s generator. We have evaluated its performance during the online testing in terms of detection rate and Iatency. The experimental results show that it is efficient in detecting different classes of attacks, including ramp and pulse attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Technique for Estimating Liquid Droplet Diameter and Liquid Water Content in Stratocumulus Clouds Using Radar and Lidar Measurements

This paper describes a technique for estimating the liquid water content (LWC) and a characteristic particle diameter in stratocumulus clouds using radar and lidar observations. The uncertainty in LWC estimate from radar and lidar measurements is significantly reduced once the characteristic particle diameter is known. The technique is independent of the drop size distribution. It is applicable for a broad range of W-band reflectivity Z between -30 and 0 dBZ and all values of lidar backscatter β observations. No partitioning of cloud or drizzle is required on the basis of an arbitrary threshold of Z as in prior studies. A method for estimating droplet diameter and LWC was derived from the electromagnetic simulations of radar and lidar observations. In situ stratocumulus cloud and drizzle probe spectra were input to the electromagnetic simulation. The retrieved droplet diameter and LWC were validated using in situ measurements from the southeastern Pacific Ocean. The retrieval method was applied to radar and lidar measurements from the northeastern Pacific. Uncertainty in the retrieved droplet diameter and LWC that are due to the measurement errors in radar and lidar backscatter measurements are 7% and 14%, respectively. The retrieved LWC was validated using the concurrent G-band radiometer estimates of the liquid water path.

54 ENVIRONMENTAL SCIENCES↗

POD-based constrained sensor placement and field reconstruction from noisy wind measurements: A perturbation study

Sensor placement at the extrema of Proper Orthogonal Decomposition (POD) is efficient and leads to accurate reconstruction of the wind field from a limited number of measure- ments. In this paper we extend this approach of sensor placement and take into account measurement errors and detect possible malfunctioning sensors. We use the 48 hourly spa- tial wind field simulation data sets simulated using the Weather Research an Forecasting (WRF) model applied to the Maine Bay to evaluate the performances of our methods. Specifically, we use an exclusion disk strategy to distribute sensors when the extrema of POD modes are close. It turns out that this strategy can also reduce the error of recon- struction from noise measurements. Also, by a cross-validation technique, we successfully locate the malfunctioning sensors.

54 ENVIRONMENTAL SCIENCES↗

Transactive Electric Water Heater Agent: Design and Performance Evaluation

Electric water heaters (EWHs) are usually equipped with inbuilt thermostats to measure water temperature near the installed positions. Most of the existing EWHs have only two thermostats and often do not have water flow sensor installed. Estimation of state of heat energy (SOHE) inside the hot water tank, which is crucial for efficient control and operation of the EWH, under such imperfect system conditions is very challenging. This paper, therefore, designs a transactive EWH agent (TEWHA) to better estimate SOHE in presence of measurement errors and imperfect system knowledge. The TEWHA, built-in Python, approximates the EWH physics using limited measurements obtained from the ground truth GridLABD model. The performance of the TEWHA is validated against ground truth system for three scenarios: a) ideal condition where TEWHA has complete knowledge of the system, b) imperfect condition where TEWHA has incomplete system information, and c) noised condition where TEWHA measurements contain random errors. Finally, an optimization problem is formulated and solved to demonstrate how TEWHA could use the estimated and measured parameters for a transactive control of EWH. Index Terms—Demand flexibility

demand flexibility, distribution system, electric ↗

Robust two-colour pyrometry uncertainty analysis to acquire spatially-resolved measurements

Two-colour pyrometry (2CP) has been used over several decades to study engine-relevant combustion processes, but results are generally regarded as qualitative or semi-quantitative. In many current 2CP systems, large measurement errors are introduced by parallax because the two measured wavelengths are not from the same line of sight. Here this work presents a spatially-resolved 2CP system with the objective of quantifying and reducing measurement uncertainty. An optical setup that eliminates parallax in 2CP is used together with pixel-by-pixel calibration of the camera sensor to increase measurement accuracy. Primary uncertainty terms are identified, and an error propagation analysis is performed to compute uncertainties in the final results of soot temperature, soot concentration parameter, KL, and soot mass. These methodologies are applied to investigate an auto-igniting fuel spray in a constant pressure flow rig at diesel-like conditions of high ambient pressure and temperature. Results show bias uncertainty of around 200 K (≈10%) for temperature and about 40%–60% for KL. High uncertainty was found to occur on the diffusion flame front where both optical thickness and soot concentrations are small. However, these uncertain measurement zones with relatively low soot concentrations contribute minimally to the total soot mass present in the reacting jet during the temporal evolution of the flame.

42 ENGINEERING↗

Current status and prospects for development of thermometry

The paper deals with results of an analysis carried out at the VNIIM with the purpose to ascertain the current status of thermometry as well as to make an attempt to determine a line of development of this field of measurements in future. The analysis was based on a survey of 150 industrial enterprises and scientific organizations. The results of the survey showed that during two last decades the accuracy of measuring instruments used in science and industry was increased almost tenfold. However, advances in the improvement of temperature measuring instruments were achieved not owing to new principles of designing thermometers, but due to rapid development of electronics, which allowed to solve the problem of accurate measurements of resistance and electromotive force and automatize measurement information processing. In most cases the contemporary measuring instruments perfectly meet the requirements to the measurement accuracy claimed by the enterprises surveyed and are provided with a necessary metrological assurance. Although there is a general understanding of the necessity to use the thermodynamic scale rather than the conditional one, we have no objective evidence with regard to how close we have to bring the international scale used in our everyday practice to the thermodynamic scale and what will be a benefit for development of science and industry. Increasing the accuracy of national standards does not affect, as a rule, the accuracy of temperature measurements in industry and scientific research since the main contribution to a total measurement error is made by components caused by an improper measurement procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-frequency (Ka-band and G-band) radar estimates of liquid water content profiles in shallow clouds

The profile of the liquid water content (LWC) in clouds provides fundamental information for understanding the internal structure of clouds, their radiative effects, propensity to precipitate, and degree of entrainment and mixing with the surrounding environment. In principle, differential absorption techniques based on coincident dual-frequency radar reflectivity observations have the potential to provide the LWC profile. Previous differential frequency radar reflectivity (DFR) efforts were challenged by the fact that the measurable differential attenuation for small quantities of LWC is usually comparable to the system measurement error. This typically renders the retrieval impractical, as the uncertainty can become many times greater than the retrieved value itself. Theoretically, this drawback can be mitigated following two interconnected approaches: (1) increasing the frequency separation between the dual-frequency radar system to measure greater differential attenuation and (2) increasing the radar operating frequency to reduce the instrument measurement random error. Our recently developed 239 GHz radar was deployed during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) along with a variety of collocated remote sensing and in situ instruments. We have combined Ka-band (35 GHz) and G-band (239 GHz) observations to retrieve the LWC from more than 100 vertical profiles of shallow clouds with typical amounts of LWC smaller than 1 g m -3 . We theoretically and experimentally demonstrate that the Ka-band and G-band pair of frequencies offers at least a 65 % relative improvement in the LWC retrieval sensitivity compared to previous works reported in the literature using lower-frequency radars. This new technique provides a missing capability to determine the LWC in the challenging low liquid water path (LWP) range (< 200 g m -2 ) and suggests a way forward to characterize microphysical and dynamical processes more precisely in shallow clouds.

54 ENVIRONMENTAL SCIENCES↗

Enhancement of flow measurements using fluid-dynamic constraints

Novel experimental modalities acquire spatially resolved velocity measurements for steady state and transient flows which are of interest for engineering and biological applications. One of the drawbacks of such high resolution velocity data is their susceptibility to measurement errors. In this paper, we propose a novel filtering strategy that allows enhancement of the noisy measurements to obtain reconstruction of smooth divergence free velocity and corresponding pressure fields which together approximately comply to a prescribed flow model. The main step in our approach consists of the appropriate use of the velocity measurements in the design of a linearized flow model which can be shown to be well-posed and consistent with the true velocity and pressure fields up to measurement and modeling errors. The reconstruction procedure is then formulated as an optimal control problem for this linearized flow model. The resulting filter has analyzable smoothing and approximation properties. We briefly discuss the discretization of the approach by finite element methods and comment on the efficient solution by iterative methods. The capability of the proposed filter to significantly reduce data noise is demonstrated by numerical tests including the application to experimental data. In addition, we compare with other methods like smoothing and solenoidal filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction for dynamic bias error in transmission measurements of void fraction

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multidimensional sum-up rounding for integer programming in optimal experimental design

Here we present a numerical method for approximating the solution of convex integer programs stemming from optimal experimental design. The statistical setup consists of a Bayesian framework for linear inverse problems for which the direct relationship is described by a discretized integral equation. Specifically, we aim to find the optimal sensor placement from a set of candidate locations where data are collected with measurement error. The convex objective function is a measure of the uncertainty, described here by the trace or log-determinant of the posterior covariance matrix, for the discretized linear inverse problem solution. The resulting convex integer program is relaxed, producing a lower bound. An upper bound is obtained by extending the sum-up rounding approach to multiple dimensions. For this extension, we analyze its accuracy as a function of the discretization mesh size for a rectangular domain. We show asymptotic optimality of the integer solution defining the upper bound for different experimental design criteria (A- and D-optimal), by proving the convergence to zero of the gap between the upper and lower bounds as the mesh size goes to zero. The technique is illustrated on a two-dimensional gravity surveying problem for both A-optimal and D-optimal sensor placement where our designs yield better results compared with a thresholding rounding approach.

97 MATHEMATICS AND COMPUTING↗

The RHIC p-Carbon CNI Polarimeter Upgrade For The Beam Polarization And Intensity Measurements

Proton polarization measurements in the AGS and RHIC (Relativistic Heavy Ion Collider at the beam energies 24-250 GeV) are based on proton-carbon and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. Polarimeter operation in the scanning mode also gives polarization profile and beam intensity profile (beam emittance) measurements. Bunch by bunch emittance measurement is a very powerful tool for machine setup. Presently, the polarization and beam intensity profile measurements (in both vertical and horizontal planes) are restricted by the long target switching time and possible target destruction during this complicated motion. The RHIC polarimeters were operated near the limit of the counting rate for present silicon strip detectors. The ongoing polarimeter upgrade for the 2009 run will address all these problems. The upgrade should allow significant reduction of the polarization measurement errors by making feasible the complete polarization measurements, which includes polarization profiles in both the horizontal and vertical planes.

43 PARTICLE ACCELERATORS↗

Soil carbon stocks from soil organic carbon at the Teller 47, Teller 27, and Kougarok 86 field sites, Seward Peninsula, Alaska, 2021 – 2023

Carbon stored in permafrost soils represents the largest terrestrial storage and hence has key significance for the global carbon cycle, yet the site-specific estimates of permafrost soil carbon are limited. To better understand permafrost carbon storage, soil organic content (SOC) was measured from soils collected at the Teller 27, Teller 47, and Kougarok 86 field sites on the Seward Peninsula, Alaska in the summers of 2019 and 2021-2023. Soil samples were collected from locations with and without near-surface permafrost to varied depths within the permafrost, where present. In addition to sample collection for soil organic carbon analysis, bulk density samples were also collected within each soil profile to allow for calculation of carbon stocks. Carbon to nitrogen ratios are also reported. Location data were collected at each observation point using a handheld GPS unit with waypoint averaging to reduce location measurement error to within 3 m. SOC was measured using elemental analysis in the laboratory. This dataset contains a *.csv file of soil carbon stocks, a *.kml file of measurement locations, a *.pdf user guide, a *.csv data dictionary, and a *.csv file level metadata.

EARTH SCIENCE > CRYOSPHERE > FROZEN GROUND↗

Minimizing User Burden in Building Energy Analysis

Infrared (IR) imagery can provide valuable data to building energy auditors and the developers of Building Energy Models (BEM). IR by itself is not a panacea to the challenges facing energy auditors and modelers, but when combined with other techniques and Open Studio software, IR can play an important role in the minimization of the burden of creating building energy models and the diagnosing of building energy problems. While IR can be used to detect and quantify many aspects of a building’s thermal and energy performance, in Phase I we focused on a single capability: determining the R value of exterior walls. Two key attributes of using IR methods for R value determination is that IR methods measure the actual, installed performance in-situ – as opposed to relying on manufacturer or handbook values – and they can integrate performance over a wide area and thus can accurately account for thermal bridging and spatial anomalies such as “spotty” insulation installation. There is a trade between user burden and accuracy when using IR to determine a wall’s R value. The least burdensome approach is computing R values from a single IR snapshot. The most burdensome method we considered was to combine IR images with thermocouple and heat flux sensor (HFS) measurements made over the course of several days. The more effort users expend in making the measurements, the more accurate and robust the method becomes. Through a series of field tests at the ThermoAnalytics Inc. (TAI) HQ at Calumet, MI and a simulation of a 1980s era office building in Flagstaff, AZ we investigated methods to compute the R value of exterior walls using data from IR cameras, thermocouples and heat flux sensors. To compute R values the heat flux through the wall, along with temperatures on either side of the wall, must be known, modeled, or estimated – and the temperature difference through the wall should be at least 10 C. If only outdoor IR images are used in the method, the inside ambient air temperature must be estimated, and a simulation model created to predict heat fluxes and the indoor wall temperature. The accuracy of the resulting R value depends on the accuracy of the simulation and the assumptions it employs. Applying thermocouple sensors, either as iButtons or as part of a wireless sensor network, to the walls allows for the acquisition of temperatures over time. The longer the duration of the measurements, the more accurate and robust the method will be. Even with this level of measurement effort, modeling is still required to calculate the heat flux through the wall. The addition of a heat flux sensor alleviates the need for any modeling, and that results in improved accuracy. Driving the accuracy of the methods are several factors that can be quantified. How well are the wall surface temperatures known? Modeling the heat flux through walls requires knowing the details of the surrounding radiant environment and the heat transfer due to convection. How well are these boundary conditions known? Even when the heat flux is measured, error can arise when some of the measured heat is not conducted through the wall but rather goes into the thermal mass of the wall. Thermal mass effects occur when conditions and the heat flux values are fluctuating. A technique that is not robust will suffer in accuracy when these fluctuations occur. The R value determination method must be incorporated into the Open Studio process. In our proposed process, IR images and other measured sensor data are input into a module that would send R value estimates to a building library developed by team member Skidmore, Owings, & Merrill (SOM). This library of parameterized building models would use these R values along with information about the building’s age, type, and location to query the Open Studio BCL to identify the most likely constructions for walls, roof, and windows. Being based on the IMF feature of Energyplus, the SOM building library can quickly produce Energyplus models of buildings based on a limited number of user inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty quantification and error analysis

UQ studies all sources of error and uncertainty, including: systematic and stochastic measurement error; ignorance; limitations of theoretical models; limitations of numerical representations of those models; limitations on the accuracy and reliability of computations, approximations, and algorithms; and human error. A more precise definition for UQ is suggested below.

99 GENERAL AND MISCELLANEOUS↗

Contextual subspace variational quantum eigensolver calculation of the dissociation curve of molecular nitrogen on a superconducting quantum computer

Abstract We present an experimental demonstration of the Contextual Subspace Variational Quantum Eigensolver on superconducting hardware. Calculating the potential energy curve of molecular nitrogen proves challenging for many conventional quantum chemistry techniques, since static correlation dominates in the dissociation limit. Our quantum simulations retain good agreement with the Full Configuration Interaction energy, outperforming all benchmarked single-reference wavefunction techniques in capturing the bond-breaking appropriately. Moreover, our methodology is competitive with multiconfigurational approaches but at a saving of quantum resource, meaning larger active spaces can be treated for a fixed qubit allowance. To achieve this result, we deploy an error mitigation/suppression strategy comprised of Dynamical Decoupling, Measurement-Error Mitigation and Zero-Noise Extrapolation. Circuit parallelization also provides passive noise-averaging and improves the effective shot yield to reduce the measurement overhead. Furthermore, we introduce a modified adaptive ansatz construction algorithm that incorporates hardware awareness into our variational circuits, minimizing the transpilation cost for the target qubit topology.

Physics↗

Dual-axis hole-drilling ESPI residual stress measurements

A novel dual-axis ESPI hole-drilling residual stress measurement method is presented. The method enables the evaluation of all the in-plane normal stress components with similar response to measurement errors, significantly lower than with single-axis measurements. A numerical method is described that takes advantage of, and compactly handles, the additional optical data that are available from the second measurement axis. Experimental tests were conducted on a calibrated specimen to demonstrate the proposed method, and the results supported theoretical expectations.

42 ENGINEERING↗

A curved edge diffraction-utilized displacement sensor for spindle metrology

This paper presents a new dimensional metrological sensing principle for a curved surface based on curved edge diffraction. Spindle error measurement technology utilizes a cylindrical or spherical target artifact attached to the spindle with non-contact sensors, typically a capacitive sensor (CS) or an eddy current sensor, pointed at the artifact. However, these sensors are designed for flat surface measurement. Therefore, measuring a target with a curved surface causes error. This is due to electric fields behaving differently between a flat and curved surface than between two flat surfaces. In this study, a laser is positioned incident to the cylindrical surface of the spindle, and a photodetector collects the total field produced by the diffraction around the target surface. The proposed sensor was compared with a CS within a range of 500 μm. The discrepancy between the proposed sensor and CS was 0.017% of the full range. Its sensing performance showed a resolution of 14 nm and a drift of less than 10 nm for 7 min of operation. This sensor was also used to measure dynamic characteristics of the spindle system (natural frequency 181.8 Hz, damping ratio 0.042) and spindle runout (22.0 μm at 2000 rpm). The combined standard uncertainty was estimated as 85.9 nm under current experiment conditions. It is anticipated that this measurement technique allows for in situ health monitoring of a precision spindle system in an accurate, convenient, and low cost manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗