Search NASA⌕ Search

SEARCH · Search NASA

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An Experiment to Study Sporadic Sodium Layers in the Earth's Mesosphere and Lower Thermosphere

The Utah State University / Space Dynamics Lab was funded under a NASA Grant. This investigation has been part of Rockwell Universities Sudden Atom Layer Investigation (SAL). USU/SDL provided an electron density measurement instrument, the plasma frequency probe, which was launched on the vehicle 21.117 from Puerto-Rico in February of 1998. The instrument successfully measured electron density as designed and measurement techniques included in this version of the Plasma Frequency probe provided valuable insight into the electron density structures associated with sudden sodium layers in a collisional plasma. Electron density data was furnished to Rockwell University but no science meetings were held by Rockwell Data from the instrument was presented to the scientific community at the URSI General Session in 1999. A paper is in preparation for publication in Geophysical Research Letters. The following document provides a summary of the experiment and data obtained as a final report on this grant.

Swenson, Charles M.↗

Constant frequency pulsed phase-locked-loop instrument for measurement of ultrasonic velocity

A new instrument based on a constant-frequency pulsed phase-locked-loop (CFPPLL) concept has been developed to accurately measure the ultrasonic wave velocity in liquids and changes in ultrasonic wave velocity in solids and liquids. An analysis of the system shows that it is immune to many of the frequency-dependent effects that plague other techniques. Measurements of the sound velocity in ultrapure water are used to confirm the analysis. The results are in excellent agreement with values from the literature, and establish that the CFPPLL provides a reliable, accurate way to measure velocities, as well as for monitoring small changes in velocity without the sensitivity to frequency-dependent phase shifts common to other measurement systems. The estimated sensitivity to phase changes is better than a few parts in 10 to the 7th.

Yost, William T.↗

HOST instrumentation R and D program overview

The HOST Instrumentation R&D program is focused on two categories of instrumentation. One category is that required to characterize the environment imposed on the hot section components of turbine engines. This category includes instruments for measuring gas flow, gas temperature, and heat flux. The second category is that for measuring the effect of the environment on the hot section components. This category includes strain measuring instruments and an optical system for viewing the interior of an operating combustor to detect cracks, buckling, carbon buildup, etc.

Englund, D. R.↗

Measuring Room Area or Volume Electronically

Area- and volume-measuring instrument hand-held or mounted on tripod. Instrument rapidly measures distances to walls, ceiling, or floor at many viewing angles and automatically computes area or volume of room. Results obtained rapidly with minimal effort.

Kavaya, M. J.↗

HOST instrumentation R and D program overview

The HOST Instrumentation R and D program is focused on two categories of instrumentation. One category is that required to characterize the environment imposed on the hot section components of turbine engines. This category includes instruments for measuring gas flow, gas temperature, and heat flux. The second category is that for measuring the effect of the environment on the hot section components. This category includes strain measuring instruments and an optical system for viewing the interior of an operating combustor to detect cracks, buckling, carbon buildup, etc.

Englund, D. R.↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire Safety↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire↗

Apparatus and Methods for Photoacoustic Measurement of Light Absorption of Particulate and Gaseous Species

In one embodiment, a photoacoustic effect measurement instrument for measuring a species (e.g., a species of PM) in a gas employs a pair of differential acoustic cells including a sample cell that receives sample gas including the species, and a reference cell that receives a filtered version of the sample gas from which the species has been substantially removed. An excitation light source provides an amplitude modulated beam to each of the acoustic cells. An array of multiple microphones is mounted to each of the differential acoustic cells, and measures an acoustic wave generated in the respective acoustic cell by absorption of light by sample gas therein to produce a respective signal. The microphones are isolated from sample gas internal to the acoustic cell by a film. A preamplifier determines a differential signal and a controller calculates concentration of the species based on the differential signal.

Yu, Zhenhong↗

A rocket borne instrument to measure electric fields inside electrified clouds

The development of a rocket borne instrument to measure electric fields in thunderstorms is described. Corona currents from a sharp needle atop a small rocket are used to sense the electric field. A high ohm resistor in series with the corona needle linearizes the relationship between corona current and electric field. The corona current feeds a relaxation oscillator, whose pulses trigger a transmitter which operates in the 395 to 410 MHz meteorological band. The instrument senses fields between 5 kV/m and 100 kV/m.

Ruhnke, L. H.↗

Instrument accurately measures stress loads in threaded bolts

Interferometric instrument response is linearly related to axial tensile stresses, and, under idealized conditions, measurement errors are within approximately plus or minus 1 percent. Ultimate accuracy of instrument depends on a number of variables, such as bolt material, dimensions, and geometry and uniformity of stresses and temperature.

Rollins, F. R., Jr.↗

Instrument for measuring thin-film belt lengths

Instrument consists of base, vernier height gauge, sliding block, and balance-beam assembly with tension weight. Pulley bracket is provided with three pulley mounting holes, 4 inches apart, to accommodate widely different belt lengths. Instrument is accurate to within 0.001 inch and is suitable for commercial production.

Casad, T. A.↗

DESIGN AND TEST OF AN INSTRUMENT FOR MEASURING MICROTHERMAL SEEING ON THE MAGDALENA RIDGE

We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0.''3 of the seeing at some times and only 0.''02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing a remote sensing instrument to measure atmospheric surface pressure

Atmospheric surface pressure can be remotely sensed from a satellite by an active instrument which measures return echoes from the ocean at frequencies near the 60 GHz oxygen absorption band. The instrument is optimized by selecting its frequencies of operation, transmitter powers and antenna size through a new procedure baesd on numerical simulation which maximizes the retrieval accuracy. The predicted standard deviation error in the retrieved surface pressure is 1 mb. In addition the measurements can be used to retrieve water vapor, cloud liquid water and sea state, which is related to wind speed.

Peckham, G. E.↗

Steam Generators: Thermal Hydraulic Measurements and Instrumentation

Steam generators are integral components of both conventional and advanced reactors utilizing steam power cycles, as they influence the power conversion performance. Steam generator designs are highly influenced by the type of reactor coolant used, which mainly governs the different control, monitoring, and safety system actuation requirements. Therefore, the present work reviews the thermal hydraulics instrumentation within steam generators designed for pressurized water reactors (PWRs), high-temperature gas-cooled reactors (HTGRs), sodium fast reactors (SFRs), and molten salt cooled reactors (MSRs). Emphasis is given to measurement techniques that are either unique or particularly important to specific reactor types. Lastly, a discussion is provided on the instrumentation and measured parameters. The work identifies standard parameters of interest and is expected to aid the development of test beds and novel measurements techniques.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

NIGHTGLOW: An Instrument to Measure the Earth's Nighttime Ultraviolet Glow - Results from the First Engineering Flight

We have designed and built an instrument to measure and monitor the "nightglow" of the Earth's atmosphere in the near ultraviolet (NUV). In this paper we describe the design of this instrument, called NIGHTGLOW. NIGHTGLOW is designed to be flown-from a high altitude research balloon, and circumnavigate the globe. NIGHTGLOW is a NASA, University of Utah, and New Mexico State University project. A test flight took place from Palestine, Texas on July 5, 2000, lasting about 8 hours. The instrument performed well and landed safely in Stiles, Texas with little damage. The resulting measurements of the NUV nightglow are consistent with previous measurements from sounding rockets and balloons. The results will be presented and discussed.

Barbier, Louis M.↗