Search NASA⌕ Search

SEARCH · Search NASA

Results for “microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Scanning Miniature Microscopes without Lenses

The figure schematically depicts some alternative designs of proposed compact, lightweight optoelectronic microscopes that would contain no lenses and would generate magnified video images of specimens. Microscopes of this type were described previously in Miniature Microscope Without Lenses (NPO - 20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43 and Reflective Variants of Miniature Microscope Without Lenses (NPO 20610), NASA Tech Briefs, Vol. 26, No. 9 (September 1999), page 6a. To recapitulate: In the design and construction of a microscope of this type, the focusing optics of a conventional microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. Elimination of focusing optics reduces the size and weight of the instrument and eliminates the need for the time-consuming focusing operation. The microscopes described in the cited prior articles contained two-dimensional CCDs registered with two-dimensional arrays of microchannels and, as such, were designed to produce full two-dimensional images, without need for scanning. The microscopes of the present proposal would contain one-dimensional (line image) CCDs registered with linear arrays of microchannels. In the operation of such a microscope, one would scan a specimen along a line perpendicular to the array axis (in other words, one would scan in pushbroom fashion). One could then synthesize a full two-dimensional image of the specimen from the line-image data acquired at one-pixel increments of position along the scan. In one of the proposed microscopes, a beam of unpolarized light for illuminating the specimen would enter from the side. This light would be reflected down onto the specimen by a nonpolarizing beam splitter attached to the microchannels at their lower ends. A portion of the light incident on the specimen would be reflected upward, through the beam splitter and along the microchannels, to form an image on the CCD. If the nonpolarizing beam splitter were replaced by a polarizing one, then the specimen would be illuminated by s-polarized light. Upon reflection from the specimen, some of the s-polarized light would become p-polarized. Only the p-polarized light would contribute to the image on the CCD; in other words, the image would contain information on the polarization rotating characteristic of the specimen.

Wang, Yu↗

Streamline-based microfluidic device

The present invention provides a streamline-based device and a method for using the device for continuous separation of particles including cells in biological fluids. The device includes a main microchannel and an array of side microchannels disposed on a substrate. The main microchannel has a plurality of stagnation points with a predetermined geometric design, for example, each of the stagnation points has a predetermined distance from the upstream edge of each of the side microchannels. The particles are separated and collected in the side microchannels.

Tai, Yu-Chong↗

Forming Limits of Thin Ferritic Stainless Steel for Fuel Cell Application

To lower the cost of fuel cell bipolar plate (BPP), less expensive ferritic stainless steel (FSS) BPP substrate materials are investigated. A series of tensile tests and multistage microchannel-forming tests were conducted on 85-µm-thick ferritic stainless steel foils, 439L, 444, and Chromeshield® 22, to understand the effect of the forming temperatures, tooling geometry, and processes on their formability. Three microchannel-forming processes were conducted, which are 1-Hit (single-stage forming), 2-Hit (two-stage forming) with 50% preform, and 2-Hit with 80% preform. FLC o s at various microchannel-forming conditions were obtained to address the formability of the ferritic stainless steel foils under plane strain conditions. It has been found that the larger the microchannel radius, the better the formability, two-stage forming is superior to the single-stage process, and a larger draw percentage in preform (stage I) leads to a higher FLC o or better formability. It has also been found from tensile tests that the thermal effect (higher temperature) has a negative impact on the failure strains. A similar phenomenon was also observed through channel-forming tests conducted at room temperature, 100 °C, and 200 °C.

08 HYDROGEN↗

On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids

The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.

Zheng, Yun↗

High-resolution imaging with a two-dimensional resistive anode photon counter

A method to achieve high spatial resolution readout of individual photoelectron events using microchannel plates and a resistive anode is presented. A clamped pair of microchannel plates is used, followed by a gap and a clamped triplet of microchannel plates in cascade to achieve a high stable electron gain of 3 x 10 to the 7th. The gain allows the position determination of each photoelectron event with a very high signal-to-noise ratio. A model consisting of a windowless vacuum-ultraviolet image sensor is presented to demonstrate 500 x 500 pixel images of 50 micron FWHM over a 25-mm circular field of view. The detector offers sufficient speed, sensitivity and resolution for a variety of applications, and the mount design is compatible with planar, remotely-processed, proximity-focused photocathodes.

Firmani, C.↗

Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS

A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.

Burton, William D., Jr.↗

Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers

A design of an Active Magnetic Regenerative Refrigeration (AMRR) system has been developed for space applications. It uses an innovative 3He cryogenic circulator to provide continuous remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. A critical component technology for this cooling system is a highly efficient active magnetic regenerator, which is a regenerative heat exchanger with its matrix material made of magnetic refrigerant gadolinium gallium garnet (GGG). Creare Inc. is developing a microchannel GGG regenerator with an anisotropic structured bed for high system thermal efficiency. The regenerator core consists of a stack of thin, single-crystal GGG disks alternating with thin polymer insulating layers. The insulating layers help minimize the axial conduction heat leak, since GGG has a very high thermal conductivity in the regenerator s operating temperature range. The GGG disks contain micro channels with width near 100 micrometers, which enhance the heat transfer between the circulating flow and the refrigerant bed. The unique flow configuration of the GGG plates ensures a uniform flow distribution across the plates. The main fabrication challenges for the regenerator are the machining of high-aspect-ratio microchannels in fragile, single-crystal GGG disks and fabrication and assembly of the GGG insulation layers. Feasibility demonstrations to date include use of an ultrashort- pulse laser to machine microchannels without producing unacceptable microcracking or deposition of recast material, as shown in the figure, and attachment of a thin insulation layer to a GGG disk without obstructing the flow paths. At the time of this reporting, efforts were focused on improving the laser machining process to increase machining speed and further reduce microcracking.

Chen, Weibo↗

Thin-wall Internal Channel Geometry and Surface Enhancements for Heat Exchangers using Laser Powder Directed Energy Deposition

Additive Manufacturing (AM) has offered many new design and manufacturing opportunities for components across various industries. As AM evolves there is a need to better understand outputs of the process including geometric limitations, surface texture, and post-processing surface enhancements for specific application requirements. One possible application area of AM are components using thin-wall (~1 mm) microchannel heat exchangers for subsystems across aerospace and industrial applications. Laser Powder Bed Fusion (L-PBF) is a common process for complex internal channels but the build diameter is limited to approximately 600 mm. Laser Powder Directed Energy Deposition (LP-DED) is being evaluated to produce thin-wall microchannel heat exchangers at scales beyond the L-PBF process. Successful deployment of the LP-DED technology requires characterization of geometric features from the process and potential improvements to the surface using post-processing. Surface texture, inclusive of roughness and waviness, is one of the critical attributes of AM that effects the friction factor and pressure drop within a heat exchanger and lacks data for the LP-DED process. This presentation will provide an overview of the characterization work completed of the LP-DED process for thin-walls and small channel geometry representative of various high performance alloys including NASA HR-1 and GRCop-42. An overview of the experiments conducted with varying LP-DED parameters, evaluation of various internal channel geometry, geometric build features, and resulting surface texture will be provided along with a summary of conclusions from these experiments. This study presents characterization of 2.5 mm microchannels using LP-DED, mechanisms that cause the surface texture which include powder adherence and material droop, and angled walls have a significant impact on the thickness and surface texture. Results will also be presented on various surface enhancement processes that allow for tuning of the wetting surface for friction factor, heat transfer, or fatigue life performance requirements.

Additive Manufacturing↗

Designing slippery rough surfaces to enhance dropwise condensation of low surface tension fluid

Enhancing low surface tension liquid condensation is critical for achieving high energy efficiency and reducing the size of thermal energy systems. Extensive research has focused on promoting dropwise condensation of these liquids using state-of-the-art coatings on plain surfaces. However, maintaining dropwise condensation with low surface tension fluids is challenging due to rivulet formation, resulting in wetted tails that transition to filmwise condensation at elevated heat fluxes. Here, to address this issue, we uncover the role of surface structures and surface chemistry in the dropwise condensation of low surface tension ethanol on slippery rough surfaces (SRS). High-performance dropwise condensation has been achieved on slippery microchannels grafted with perfluoropolyether. The SRS uniquely facilitates rapid lateral droplet removal, enabling faster directional droplet shedding without rivulet formation. The resulting higher droplet removal frequency on SRS leads to heat transfer coefficients 100 % and 500 % higher than conventional dropwise and filmwise condensation on plain surfaces, respectively. Our findings uncover the pivotal role of rapid droplet removal through slippery microchannels in sustaining dropwise condensation of low surface tension liquids. This study introduces a new paradigm for promoting dropwise condensation using engineered SRS that incorporates surface structure and surface chemistry. The work will provide fundamental design guidelines to design efficient and compact condensers that use costly or flammable low global warming potential refrigerants in future refrigeration systems.

Dropwise condensation↗

High Frequency Design Considerations for the Large Detector Number and Small Form Factor Dual Electron Spectrometer of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

Each half of the Dual Electron Spectrometer (DES) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission utilizes a microchannel plate Chevron stack feeding 16 separate detection channels each with a dedicated anode and amplifier/discriminator chip. The desire to detect events on a single channel with a temporal spacing of 100 ns and a fixed dead-time drove our decision to use an amplifier/discriminator with a very fast (GHz class) front end. Since the inherent frequency response of each pulse in the output of the DES microchannel plate system also has frequency components above a GHz, this produced a number of design constraints not normally expected in electronic systems operating at peak speeds of 10 MHz. Additional constraints are imposed by the geometry of the instrument requiring all 16 channels along with each anode and amplifier/discriminator to be packaged in a relatively small space. We developed an electrical model for board level interactions between the detector channels to allow us to design a board topology which gave us the best detection sensitivity and lowest channel to channel crosstalk. The amplifier/discriminator output was designed to prevent the outputs from one channel from producing triggers on the inputs of other channels. A number of Radio Frequency design techniques were then applied to prevent signals from other subsystems (e.g. the high voltage power supply, command and data handling board, and Ultraviolet stimulation for the MCP) from generating false events. These techniques enabled us to operate the board at its highest sensitivity when operated in isolation and at very high sensitivity when placed into the overall system.

Microchannel plates high frequency performance↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Monitoring the impact of confinement on hyphal penetration and fungal behavior

Through their expansive mycelium network, soil fungi alter the physical arrangement and chemical composition of their local environment. This can significantly impact bacterial distribution and nutrient transport and can play a dramatic role in shaping the rhizosphere around a developing plant. However, direct observation and quantitation of such behaviors is extremely difficult due to the opacity and complex porosity of the soil microenvironment. In this study, we demonstrate the development and use of an engineered microhabitat to visualize fungal growth in response to varied levels of confinement. Microfluidics were fabricated using photolithography and conventional soft lithography, assembled onto glass slides, and prepared to accommodate fungal cultures. Selected fungal strains across three phyla (Ascomycota: Morchella sextalata , Fusarium falciforme ; Mucoromycota: Linnemannia elongata , Podila minutissima , Benniella ; Basidiomycota: Laccaria bicolor , and Serendipita sp.) were cultured within microhabitats and imaged using time-lapse microscopy to visualize development at the mycelial level. Fungal hyphae of each strain were imaged as they penetrated through microchannels with well-defined pore dimensions. The hyphal penetration rates through the microchannels were quantified via image analysis. Other behaviors, including differences in the degree of branching, peer movement, and tip strength were also recorded for each strain. Our results provide a repeatable and easy-to-use approach for culturing fungi within a microfluidics platform and for visualizing the impact of confinement on hyphal growth and other fungal behaviors pertinent to their remodeling of the underground environment.

Guo, Yi-Syuan (ORCID:0000000340142225)↗

Uncertainty-Based Design: Finite Element and Explainable Machine Learning Modeling of Carbon–Carbon Composites for Ultra-High Temperature Solar Receivers

Design under uncertainty has significantly grown in research developments during the past decade. Additionally, machine learning (ML) and explainable ML (XML) have offered various opportunities to provide reliable predictable models. The current article investigates the use of finite element modeling (FEM), ML and XML predictions, and uncertain-based design of carbon-carbon (C-C) composites for use in ultra-high temperatures. A C-C composite concentrating solar power (CSP) as a microvascular receiver is considered as a case study. These C-C composites are fiber composites with directly integrated carbonized microchannels to form a lightweight, high-absorptivity material that includes an embedded microvascular network of channels. The topology of these microchannels is engineered to optimize heat transfer to a supercritical carbon dioxide (sCO2) heat transfer fluid. The mechanical characterization of C-C composites is highly challenging. Thus, designing every component made of C-C composites for ultra-high temperature applications needs an uncertainty-based analysis. As a part of a comprehensive project on the development of a novel carbonized microvascular C-C composite, this paper explores C-C composite sensitivity analysis, FEM, ML prediction, and XML analysis. The resulting composite can then be carbonized and coated with an oxidation-resistant coating to form a thermally efficient and mechanically robust C-C composite. An ANSYS 3-D-FE model was used to analyze the CSP’s stress/strain. To consider the variability in the mechanical and thermal properties of C-C composites, various mechanical properties are considered as the ANSYS FEM’s input. A synthetic dataset from 730 ANSYS runs was produced to feed into the ML and XML algorithms for uncertainty analysis and prediction. The ML and XML algorithms could accurately predict the CSP stresses/strains.

Daghigh, Vahid (ORCID:0000000298941620)↗

Research study on stellar X-ray imaging experiment, volume 1

The use of microchannel plates as focal plane readout devices and the evaluation of mirrors for X-ray telescopes applied to stellar X-ray imaging is discussed. The microchannel plate outputs were either imaged on a phosphor screen which was viewed by a low light level vidicon or on a wire array which was read out by digitally processing the output of a charge division network attached to the wires. A service life test which was conducted on two image intensifiers is described.

Wilson, H. H.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

Quadrant anode image sensor

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.

Lampton, M.↗

High resolution imaging X-ray detector for astronomical measurements

The article describes the X-ray detector which will provide second-of-arc images for the HEAO-B X-ray observatory. The instrument uses microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. Position determination is accomplished by electronic interpolation between the coarse grid wires. The detector provides the arrival time and position of each event which occurs within its field of view. Measurements of the spatial resolution (15 microns), temporal resolution (7.8 microsec), image distortion (less than 10 microns), uniformity of efficiency (less than plus or minus 10%), dark counting rate (0.2 cts/sq cm/s), and quantum efficiency (10% at 1.54 keV) of this detector are described. A summary of the procedure which was found useful during the initial turn-on of microchannel plates is given.

Henry, J. P.↗