Fabricating PFPE Membranes for Microfluidic Valves and Pumps

A process has been developed for fabricating membranes of a perfluoropolyether (PFPE) and integrating them into valves and pumps in laboratory-on-achip microfluidic devices. Membranes of poly(tetrafluoroethylene) [PTFE] and poly(dimethylsilane) [PDMS] have been considered for this purpose and found wanting. By making it possible to use PFPE instead of PTFE or PDMS, the present process expands the array of options for further development of microfluidic devices for diverse applications that could include detection of biochemicals of interest, detection of toxins and biowarfare agents, synthesis and analysis of proteins, medical diagnosis, and synthesis of fuels.

Greer, Frank↗

Microfluidic Cell-based Assays in Stem Cell and Other Rare Cell Type Research

Microfluidics is a technology defined by the engineered precise manipulation of minute amount of liquids through channels with dimensions in the micron scale. Much of microfluidic devices used for biomedical purposes are produced in the form of so called “lab-on-a-chip” format, where multiple steps of conventional biochemical analyses such as staining, washing, and signal collection are miniaturized and integrated into chips fabricated from polymer or glass. Cell-based microfluidic lab-on-achip technology provides some obvious advantages: 1) drastically reduced sample and reagent requirement, and 2) separation and detection with improved sensitivity due to fluid properties at the microscale, i.e. laminar flow. Based on these two advantages, the obvious place where microfluidic cell assays will provide the most benefit is wherescientists must gather much information from precious little sample. Stem cells and other precious cell types such as circulating tumor cells (CTCs), and rare immune subsets are the perfect match for microfluidic multiplex assays. The recent demonstration that multiple cellular changes such as surface receptor activation, protein translocation, long and short RNA, and DNA changes can all be extracted from intact single cells paves the way to systems level understanding of cellular states during development or disease. Finally, with the ability to preserve cell integrity in a microfluidic device during multiplexed analysis, one also preserves the single cell resolution, where information regarding the cell-to-cell heterogeneity during differentiation or response to stimuli is vitally important.

59 BASIC BIOLOGICAL SCIENCES↗

Plumbing Fixture for a Microfluidic Cartridge

A fixture has been devised for making the plumbing connections between a microfluidic device in a replaceable cartridge and an external fluidic system. The fixture includes a 0.25-in. (6.35-mm) thick steel plate, to which the cartridge is fastened by two 10-32 thumb screws. The plate holds one plumbing fitting for the inlet and one for the outlet of the microfluidic device. Each fitting includes a fused-silica tube of 0.006-in. (approx.0.15-mm) inside diameter within a fluorinated ethylene-propylene (FEP) tube of 0.0155-in. (approx.0.39-mm) inside diameter and 0.062- in. (approx.1.57-mm) outside diameter. The FEP tube is press-fit through the steel plate so that its exposed end is flush with the surface of the plate, and the silica tube protrudes 0.03 in. (approx.0.76 mm) from the plate/FEP-tube-end surface. The cartridge includes a glass cover plate that contains 0.06-mm-wide access ports. When the cartridge is fastened to the steel plate, the silica tubes become inserted through the access ports and into the body of the cartridge, while the ends of the FEP tubes become butted against the glass cover plate. An extremely tight seal is thereby made.

Francis, Kevin↗

Ultrasensitive Nanoelectrospray Ionization-Mass Spectrometry using Poly(dimethylsiloxane) Microchips with Monolithically Integrated Emitters

Poly(dimethylsiloxane) (PDMS) is the most widely used substrate for microfluidic devices as it enables facile fabrication and has other distinctive properties. However, for applications involving highly sensitive nanoelectrospray ionization mass spectrometry (nanoESI-MS) detection, the use of PDMS microdevices has been hindered by the leaching of uncross-linked oligomers and other contaminants from the substrate that yields a large background of chemical noise in the mass spectra. A more general challenge is that microfluidic devices containing integrated electrospray emitters are frequently unable to operate stably in the nanoflow regime where the best sensitivity is achieved. In this report, we extracted the contaminants from PDMS substrates using a series of solvents, eliminating the background observed when untreated PDMS microchips are used for nanoESI-MS. Optimization of the integrated emitter geometry enabled stable operation at flow rates as low as 10 nL/min. Peptide concentrations of 1 nM were readily detected, representing ~170 zmol of consumed analyte, and an extrapolated detection limit of ~40 zmol; these are the lowest mass and concentration detection limits reported to date for a microchip having an integrated electrospray emitter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile. An additional benefit to integrating a high-surface-area template within the fluid channel of a medicine delivery device is that one can envision a number of different functional coatings that could facilitate the capture and analysis of either microbial contaminants or the medicine itself. For example, one could attach antibodies or some other binding agent with a specific affinity to the silicon nanotip template. Once a target molecule or microbe is bound to the high-surface- area template, one could use an optical analytical technique such as fluorescence or adsorption to determine the identity and potentially the concentration of the species of interest. By illuminating the bound species from the back, it may also be possible to probe only the molecules with an evanescent wave, making detection of the species from the front side of the device much simpler.

Shearn, Michael J.↗

The Gene Fitness Atlas: A Roadmap for Predicting Evolution

We developed a novel, high-throughput microfluidic device design containing “interaction zones” where progeny cell lines compete against each other allowing for accurate analysis of bacterial cell fitness. The goal of the project was to use the device for two applications: 1) gene knockout screening and 2) antibiotic resistance screening. The microfluidic platform was fabricated using photolithography and soft lithography in polydimethylsiloxane (PDMS). E.coli Keio mutants and fluorescent wildtype parent were chosen for the study. Cells were grown overnight and their loading into the devices and seeding in mother machines was optimized. For mutant screening, the least fit mutant and wildtype parent were cultured individually and then added to the microfluidic device. The mother machines which were seeded with mutant and wildtype were imaged through time lapse microscopy and the growth of cells was observed. For antibiotic screening, wildtype E.coli cells which were grown overnight were added to the device and washed with media containing the antibiotic ampicillin. The growth pattern in presence and absence of ampicillin was observed through time lapse microscopy. It was observed that over a period of four hours, both the mutant and the wildtype divided in the mother machine and pushed daughter cells out into the interaction zone. In case of the antibiotic screening experiment, the fluorescent wildtype divided both in the absence and presence of sublethal concentration of ampicillin. This study is a proof of concept demonstration of high- throughput single cell analysis of cells using a novel microfluidics device.

59 BASIC BIOLOGICAL SCIENCES↗

Hybrid immersed interface-immersed boundary methods for AC dielectrophoresis

Dielectrophoresis, a nonlinear electrokinetic transport mechanism, has become popular in many engineering applications including manipulation, characterization and actuation of biomaterials, particles and biological cells. In this paper, we present a hybrid immersed interface–immersed boundary method to study AC dielectrophoresis where an algorithm is developed to solve the complex Poisson equation using a real variable formulation. An immersed interface method is employed to obtain the AC electric field in a fluid media with suspended particles and an immersed boundary method is used for the fluid equations and particle transport. The convergence of the proposed algorithm as well as validation of the hybrid scheme with experimental results is presented. In this paper, the Maxwell stress tensor is used to calculate the dielectrophoretic force acting on particles by considering the physical effect of particles in the computational domain. Thus, this study eliminates the approximations used in point dipole methods for calculating dielectrophoretic force. A comparative study between Maxwell stress tensor and point dipole methods for computing dielectrophoretic forces are presented. The hybrid method is used to investigate the physics of dielectrophoresis in microfluidic devices using an AC electric field. The numerical results show that with proper design and appropriate selection of applied potential and frequency, global electric field minima can be obtained to facilitate multiple particle trapping by exploiting the mechanism of negative dielectrophoresis. Our numerical results also show that electrically neutral particles form a chain parallel to the applied electric field irrespective of their initial orientation when an AC electric field is applied. This proposed hybrid numerical scheme will help to better understand dielectrophoresis and to design and optimize microfluidic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microfabricated systems and assays for studying the cytoskeletal organization, micromechanics, and motility patterns of cancerous cells

Cell motions are driven by coordinated actions of the intracellular cytoskeleton – actin, microtubules (MTs) and substrate/focal adhesions (FAs). This coordination is altered in metastatic cancer cells resulting in deregulated and increased cellular motility. Microfabrication tools, including photolithography, micromolding, microcontact printing, wet stamping and microfluidic devices have emerged as a powerful set of experimental tools with which to probe and define the differences in cytoskeleton organization/dynamics and cell motility patterns in non-metastatic and metastatic cancer cells. In this paper, we discuss four categories of microfabricated systems: (i) micropatterned substrates for studying of cell motility sub-processes (for example, MT targeting of FAs or cell polarization); (ii) systems for studying cell mechanical properties, (iii) systems for probing overall cell motility patterns within challenging geometric confines relevant to metastasis (for example, linear and ratchet geometries), and (iv) microfluidic devices that incorporate co-cultures of multiple cell types and chemical gradients to mimic in vivo intravasation/extravasation steps of metastasis. Finally, together, these systems allow for creating controlled microenvironments that not only mimic complex soft tissues, but are also compatible with live cell high-resolution imaging and quantitative analysis of single cell behavior.

59 BASIC BIOLOGICAL SCIENCES↗

Enzyme entrapped nanoporous scaffolds formed through flow induced gelation in microfluidic filter device for sensitive biosensing of organophosphorus compounds

A novel and versatile processing method was developed for the formation of gel scaffolds with in-situ AChE-AuNPs immobilization for biosensing of organophosphorus compounds. The biosensor designed by our new approach shows high sensitivity, selectivity and reactivation efficiency. This flow induced immobilziation technique opens up new pathways for designing simple, fast, biocompatible, and cost-effective process for enhanced sensor performance and on-site testing of a variety of toxic organophosphorus compounds.

47 OTHER INSTRUMENTATION↗

Hybrid Encapsulated Ionic Liquids for Post-Combustion Carbon Dioxide (CO 2 ) Capture

It is increasingly clear that carbon dioxide (CO 2 ) capture and sequestration (CCS) must play a critical role in curbing worldwide CO 2 emissions to the atmosphere. Previously, we have developed ionic liquids (ILs) and phase change ionic liquids (PCILs) for post-combustion CO 2 capture. In this project, we synthesized and tested 19 ILs and PCILs and chose one of each for further development. The IL selected for further development was triethyl(octyl)phosphonium 2-cyanopyrrolide ([P 2228 ][2CNPyr]), which has the same anion but a different cation, than used in our previous work. The new cation imparts a lower viscosity than the prior cation. The PCIL selected for further development was tetraethylphosphonium benzimidazolide ([P 2222 ][BnIm]), which was developed in an Advanced Research Projects Agency-Energy (ARPA-E) project. Although we made numerous other candidates, none were better than this original PCIL. Here we showed that the CO 2 absorption by the IL and the PCIL was completely reversible, even when water was present. We determined and quantified the additional chemistry, involving the formation of bicarbonate, when water is present. The IL and PCIL were encapsulated in silicone shells using a microfluidic device. Compatibility between the IL/PCIL and the polymer, viscosity, and surface tension issues, getting sufficiently high IL/PCIL loading and leakage (likely from insufficient cross-linking), were serious challenges. Small quantities (~ 1 g) of microcapsules with good integrity of both the IL and the PCIL were produced. The CO 2 uptake by these capsules was the same as for the free IL and PCIL and the capacity of the capsules decreased only slightly even after five absorption and desorption cycles. As expected, the IL and PCIL (and subsequently the encapsulated IL and PCIL) reacted readily with SO 2 and NO, so, like aqueous amine absorbents, the CO 2 capture unit would have to be located downstream of the flue gas desulfurization and other gas treatment units. Large samples (~70 g and 100 g) of encapsulated PCIL were produced in a parallel microfluidic device and in an in-air device. These capsules were tested in a Laboratory Scale Unit (LSU) to demonstrate uptake capacity in a fluidized bed. We also used the LSU to determine recyclability and mass transfer coefficients. Unfortunately, equivalent experiments with the IL were not possible due to difficulties with producing large samples of the encapsulated IL. This IL encapsulation “scale-up” problem was not solved during the course of this project. Nonetheless, using the PCIL microcapsules we demonstrated that, as expected, the mass transfer is internally controlled. In concert with a new rate-based model of the fluidized bed, we determined that the productivity is increased by a factor of 4.75 in the microcapsule fluidized bed absorber compared to a conventional liquid-gas packed bed absorber. The initial technoeconomic model shows that the capital cost for the microcapsule IL continuous fluidized bed process is similar to that of an aqueous amine process (specifically, the Econamine FG Plus technology). However, the stripping heat requirements are about 35% less for the model IL microcapsule case compared to the monoethanolamine (MEA) case. Thus, encapsulated ILs/PCILs in a continuous fluidized bed absorber for post-combustion CO 2 capture are a significant improvement over the free IL/PCIL case and represent a major reduction in the parasitic energy requirements compared to aqueous amine process.

20 FOSSIL-FUELED POWER PLANTS↗

Method for a microfluidic weaklink device

The present invention relates to an electrokinetic (EK) pump capable of creating high pressures electroosmotically, and capable of retaining high pressures. Both pressure creation and retention are accomplished without the need for moving parts. The EK pump uses a polymerizable fluid that creates the pressure-retaining seal within the EK pump when polymerization is initiated, typically by exposure to UV radiation. Weaklink devices are advantageously constructed including such a pressure-retaining EK pump since, among other advantages, the response of the weaklink device relies on predictable and reliable chemical polymerization reactions.

47 OTHER INSTRUMENTATION↗

Mass and Momentum Transport in Microcavities for Diffusion-Dominant Cell Culture Applications

For the informed design of microfluidic devices, it is important to understand transport phenomena at the microscale. This letter outlines an analytically-driven approach to the design of rectangular microcavities extending perpendicular to a perfusion microchannel for microfluidic cell culture devices. We present equations to estimate the spatial transition from advection- to diffusion-dominant transport inside cavities as a function of the geometry and flow conditions. We also estimate the time required for molecules, such as nutrients or drugs to travel from the microchannel to a given depth into the cavity. These analytical predictions can facilitate the rational design of microfluidic devices to optimize and maintain long-term, physiologically-based culture conditions with low fluid shear stress.

Yew, Alvin G.↗

Design, fabrication and test of a pneumatically controlled, renewable, microfluidic bead trapping device for sequential injection analysis applications

This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upward against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.

beads trapping↗

Self-Assembly of MXene-Surfactants at Liquid–Liquid Interfaces: From Structured Liquids to 3D Aerogels

2D transition metal carbides and nitrides (MXenes), a class of emerging nanomaterials with intriguing properties, have attracted significant attention in recent years. However, owing to the highly hydrophilic nature of MXene nanosheets, assembly strategies of MXene at liquid-liquid interfaces have been very limited and challenging. Here in this paper, through the cooperative assembly of MXene and amine-functionalized polyhedral oligomeric silsesquioxane at the oil-water interface, we report the formation, assembly, and jamming of a new type MXene-based Janus-like nanoparticle surfactants, termed MXene-surfactants (MXSs), which can significantly enhance the interfacial activity of MXene nanosheets. More importantly, this simple assembly strategy opens a new platform for the fabrication of functional MXene assemblies from mesoscale (e.g., structured liquids) to macroscale (e.g., aerogels), that can be used for a range of applications, including nanocomposites, electronic devices, and all-liquid microfluidic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗