At least 163 records · Page 9

Improving Satellite Compatible Microdevices to Study Biology in Space

The technology for biology in space lags far behind the gold standard for biological experiments on Earth. To remedy this disparity, the Rothschild lab works on proof of concept, prototyping, and developing of new sensors and devices to further the capabilities of biology research on satellites. One such device is the PowerCell Payload System. One goal for synthetic biology in aiding space travel and colonization is to genetically engineer living cells to produce biochemicals in space. However, such farming in space presupposes bacteria retain their functionality post-launch, bombarded by radiation, and without the 1G of Earth. Our questions is, does a co-culture of cyanobacteria and protein-synthesizing bacteria produce Earth-like yields of target proteins? Is the yield sensitive to variable gravitational forces? To answer these questions, a PowerCell Payload System will spend 1 year aboard the German Aerospace Center's Euglena and Combined Regenerative Organic-food Production In Space (Eu:CROPIS) mission satellite. The PowerCell system is a pair of two 48-well microfluidic cards, each well seeded with bacteria. The system integrates fluidic, thermal, optical, electronic, and control systems to germinate bacteria spores, then measure the protein synthesized for comparison to parallel experiments conducted on the Earth. In developing the PowerCell Payload, we gained insight into the shortcomings of biology experiments on satellites. To address these issues, we have started three new prototyping projects: 1) The development of an extremely stable and radiation resistant cell-free system, allowing for the construction of proteins utilizing only cell components instead of living cells. This can be lyophilized on a substrate, like paper. (2) Using paper as a microfluidic platform that is flexible, stable, cheap, and wicking. The capillary action eliminates the need for pumps, reducing volume, mass, and potential failing points. Electrodes can be printed on the paper to sense for biochemicals. (3) Developing a modular, semi-autonomous microfluidic device that can be easily adapted for a variety of common biological experiments. This versatility will allow for quicker and cheaper experimentation. These improvements to satellite experiment platforms have the potential to radically increase the return from NASA's biological and field studies with reduced development time, mass, and cost with increased robustness data and interpretation.

biology in spac↗

Developing Fluorescence-Based Sensors to Support Rare Earth Element Separation

Rare earth elements (REEs) are essential to most renewable energy technologies. Unfortunately, as we transition to sustainable energy production, the demand for REEs is rapidly growing well beyond current rates of production. As a result, novel means of efficient, scalable, and easily adaptable methods for processing primary and recycle feedstocks are needed. Development and integration of sensors for highly selective in-line monitoring can support more efficient design and testing of such novel separation processes, as well as more cost-effective deployment of those separation flowsheets. Work here will explore the application of fluorescence spectroscopy, a highly sensitive and selective technique, to quantify multiple lanthanides in complex mixtures including known interferents or quenching agents. Results include identification of the optimal excitation wavelength and the limit of detection of various rare earth elements as well as the performance of data-science-based quantification approaches in streams where “unknowns” are present. Overall, the data science tools in conjunction with optical sensor data were able to quantify analytes in the presence of other lanthanides which can be anticipated in the actual industrial stream. Here we include characterization of lanthanides in a microfluidic device similar to those used in new process development. This study demonstrates the capability of utilizing fluorescence spectroscopy to quantify analytes in a complicated solution matrix, suggesting this is a successful approach for in-line monitoring to optimize the separation efficiency in an industrial stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic, Adaptive, Systems and Materials: Complex, Simple and Emergent Behaviors

This program has been funded by DoE/BES for twenty years. It has moved into and out of various subjects as it has developed, but it has retained its focus on complexity and complex systems. The project has evolved in the following way: Self-Assembly and Biomimetic Self-Assembly: All self-assembling systems depend upon a minimum of two types of interaction: a repulsion and an attraction. For the familiar molecular systems, attractive interactions are typically hydrogen bonds and electrostatic interactions. Repulsive interactions include steric effects, hydrophobic effects (in biological systems), and charge-charge repulsion. We have expanded this repertoire to include surface interactions, magnetic interactions, and others. I list these systems in the order in which we have explored them: i) A key emphasis in current work is in understanding how the movement of ions in a magnetic field (the Lorentz effect) interacts with catalytic systems. We have demonstrated that an acceleration in rate of reduction of CO 2 to CO can be accomplished by applying an external magnetic field. This acceleration is largely due to the application of the Lorentz effect on mass transport at the catalyst’s surface. ii) We have also extensively explored the influence of electrostatics, as exhibited in self-assembling systems, by tribocharging. iii) Another key system involves surface tension effects; examples include interactions between heavy particles floating at a liquid-air interface, and interacting by changes in surface area; interactions of bubbles and bubble rafts, behaviors of bubble trains in microfluidic networks, and behaviors of microorganisms in constraining environments. iv) This work has intentionally de-emphasized biological systems; but it does include some work on protein-ligand interactions and interactions among microorganisms. v) We have also explored applications of some of these effects, these explorations include bubble rafts as diffraction gratings, exploration of the structures that can be obtained by tribocharging and uses of these structures in exploring nucleation and melting of crystals. vi) Although not a major focus of this work, several other topics have emerged and offer opportunities for future work. These include the behavior of bubble trains and bubble rafts in microfluidic systems. A particularly interesting example is the formation of bubble trains that repeat in the alteration of large and small bubbles according to rules we do not presently understand, but are uniquely large-period oscillating systems. These systems offer a new route into understanding the instabilities of the type represented by oscillations. vii) We have also begun exploratory projects on magnetic levitation (especially to determine molecular density), and information storage (in molecules). Magnetic Levitation: Self-assembling and biomimetic systems require both attraction and repulsion. We have used electrostatics (tribocharging), interfacial free-energies (surface tension and related forces) and others. Potential uses include reconfigurable diffraction gratings and liquid lenses; exploration of mechanisms in tribocharging; tunneling in EGaIn junctions; and bubble trains (especially in micro-fluidic systems). Examples of systems representing these topics is included in the following papers: Complexity: Disks rotating at a water-air interface; Benard-Marangoni effects; Vortex-Crystals from spinning magnetic disks (Marangoni effects); EGaIn Electrode to study quantum tunneling; Self-Assembly of electrostatically-charged metallic spheres (electrets); Dynamically reconfigurable lens; Using computational designs of ligands for enzymes; Electrostatic self-assembly by tribocharging; Monodisperse bubble trains in microchannel systems; Inverted dripping faucet; Flames; Printing of micro-organisms to regenerate the “ink” of printing device; Using micro-organisms to move loads (“microoxen”); Motion of bacterial swarms near surfaces; Making monodisperse particles in microfluidic systems; Coding/decoding of information stored in droplet trains in microfluidic networks; Magnetic levitation; and Information storage. i) Tribocharging. The change in focus of this work on electrets from the fundamentals of charging to applications of these materials in studying self-assembly using electrostatic interactions. ii) Bubbles in Microchannels. The realization that systems of bubbles in microchannels represented a major opportunity to study complexity in a very tractable system, and the development of a semi-quantitative theory of this subject. iii) Flames. The growth of “flames” remains an exploratory subject for the research, although their currently relatively little active work involving it ongoing. iv) Systems with Microorganisms. The removal of work in biological systems from this project. Based on work supported in this program, we now have a significant project on the development of microfluidic tools for studying C. elegans (a nematode), but this work was not appropriate for a program focused on complexity, and we developed separate support for it. (It is, however, an example of successful seeding of a new area by BES.) The work on electrets has gone through a period in which a part of the program was the subject of a MURI; the focus of this work was to develop materials that did not charge electrostatically on friction or contact. The MURI is now over, and the work on dynamic self-assembly (supported by BES) is the major focus. “Flames” has also enjoyed synergistic support, in terms of a project supported by DARPA on flame suppression (in the absence of extinguishing agents, using acoustic and electrostatic interactions). This work was helpful in understanding some of the basics of flames, but is entirely distinct from the BES focus in complexity. A growing interest is in the Lorentz effect. The Lorentz effect is the force exerted on charged particles (electrons, ions, charged molecules) when they move through a perpendicular magnetic field. The Lorentz effect is almost ubiquitous in modern technology: examples of applications include electric motors, dynamos, cathode ray tubes, many batteries, and most systems that control electrical currents with magnetic forces. We have begun to explore the Lorentz effect in electrochemical systems and heterogeneous catalytic systems involving charged organic species and inorganic ions. This work is still at an early stage, but initial studies that Lorentz effects can be large when ions move through magnetic fields, or magnetic fields move in the presence of ions.

36 MATERIALS SCIENCE↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

Analysis of heat transfer and AuNPs-mediated photo-thermal inactivation of E. coli at varying laser powers using single-phase CFD modeling

In the wake of the COVID-19 pandemics, the demand for innovative and effective methods of bacterial inactivation has become a critical area of research, providing the impetus for this study. The purpose of this research is to analyze the AuNPs-mediated photothermal inactivation of E. coli. Gold nanoparticles irradiated by laser represent a promising technique for combating bacterial infection that combines high-tech and scientific progress. The intermediate aim of the work was to present the calibration of the model with respect to the gold nanorods experiment. The purpose of this work is to study the effect of initial concentration of E. coli bacteria, the design of the chamber and the laser power on heat transfer and inactivation of E. coli bacteria. Using the CFD simulation, the work combines three main concepts. 1. The conversion of laser light to heat has been described by a combination of three distinctive approximations: a- Discrete particle integration to take into account every nanoparticle within the system, b- Rayleigh-Drude approximation to determine the scattering and extinction coefficients and c- Lambert–Beer–Bourger law to describe the decrease in laser intensity across the AuNPs. 2. The contribution of the presence of E. coli bacteria to the thermal and fluid-dynamic fields in the microdevice was modeled by single-phase approach by determining the effective thermophysical properties of the water-bacteria mixture. 3. An approach based on a temperature threshold attained at which bacteria will be inactivated, has been used to predict bacterial response to temperature increases. The comparison of the thermal fields and temporal temperature changes obtained by the CFD simulation with those obtained experimentally confirms the accuracy of the light-heat conversion model derived from the aforementioned approximations. The results show a linear relationship between maximum temperature and variation in laser power over the range studied, which is in line with previous experimental results. It was also found that the temperature inside the microchamber can exceed 55 °C only when a laser power higher than 0.8 W is used, so bacterial inactivation begins. The experimental data allows to determinate the concentration of nanoparticles. This parameter is introduced into the mathematical model obtaining the same number of AuNPs. However, this assumption introduces a certain simplification, as in the mathematical model the distribution of nanoparticles is uniform. This work is directly connected to the use of gold nanoparticles for energy conversion, as well as the field of bacterial inactivation in microfluidic systems such as lab-on-a-chip. Presented mathematical and numerical models can be extended to the entire spectrum of wavelengths with particular use of white light in the inactivation of bacteria. This work represents a significant advancement in the field, as to the best of the authors’ knowledge, it is the first to employ a single-phase computational fluid dynamics (CFD) approach specifically combined with the thermal inactivation of bacteria. Moreover, this research pioneers the use of a numerical simulation to analyze the temperature threshold of photothermal inactivation of E. coli mediated by gold nanorods (AuNRs). The integration of these methodologies offers a new perspective on optimizing bacterial inactivation techniques, making this study a valuable contribution to both computational modeling and biomedical applications.

36 MATERIALS SCIENCE↗

Capillary electrophoresis-electrochemistry microfluidic system for the determination of organic peroxides

A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.

NASA Discipline Life Sciences Technologies↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Journal Pre-proof3D printed polylactic acid and acrylonitrile butadiene styrene fluidicstructures for biological applications: tailoring bio-material interfaceviasurface modification

Three-dimensional (3D) printing is a rapidly growing technology that best fits for cell culture and other biological applications due to its potential to build immensely complex structures from customized designs. However, use of 3D printed structures for cell adhesion, proliferation, and activation requires tailoring of surface characteristics. In this context, this work investigates the use of two biocompatible 3D printable polymer materials, Poly-L-lactic Acid (PLA) and Acrylonitrile Butadiene Styrene (ABS) for bio applications, and the effect of their post-printing surface modification processes to achieve desired bio functionality. Three post-printing surface modification techniques, alkaline hydrolysis, ultraviolet ozone plasma irradiation and gold thin film deposition are performed with the objective of introducing useful levels of surface functionalities. Poly-L-lysine (PLL) labelled with FITC chromophore is immobilized on the surface modified samples following standard protocols. The effect of surface roughness and porosity of the 3D printed structures on the polypeptide immobilization is compared on as-printed versus mechanically polished surfaces. Different characterization methods, viz., Fluorescence microscopy, Raman Spectroscopy and UV–vis spectroscopy, are used to study the efficacy of the surface modification and PLL immobilization techniques. Our results demonstrated denser PLL attachment on polished hydrolyzed PLA and ABS surfaces which enables the use of these printable polymers for a range of applications such as tissue scaffolds and microfluidics.

3D Printing, PLA, ABS, Biodegradable Polymer, Surf↗

Dynamic separation of gases using microsieves

Separation of light weight molecules, such as nitrogen, argon, and oxygen, from heavier compounds can have significant impacts on energy capture, environmental monitoring, or isotopic applications. Large-scale gas separation techniques, like gas centrifugation and membrane mitigation, can be problematic as they impart tremendous energy and induce high mechanical stress onto the instrumentation. Microsieves, also known as micronozzles or microfunnels, are developed to create physical barriers to separate specific isotopes and gases. Separation is achieved using a converging and diverging micronozzle to impose supersonic gas flow around a curved wall, and it has been used for the separation of heavy actinide isotopes in low weight gas as well as separation of low weight gas compositions of nitrogen and argon back in 1900s. However, systematic reviews of this unique technology are lacking. The application of the Laval style nozzle, which has a converging/diverging entrance fundamental to the micronozzle, is included in this review due to its importance in industrial applications in uranium (U) isotope refinement. Using advanced computational fluid dynamic (CFD) simulations, the extent of gas separation can be modelled. Herein, we first examine the literature and survey recent advances on fabrication techniques for creating curved micronozzles, methods and separation principles used to design devices. Furthermore, we then follow with highlights of CFD simulations applied to evaluate the separation effects using microsieves. Finally, identification of the gap and recommendation for future development and applications are suggested for using intrinsic molecular features and fluidic dynamics in formulating separation strategies.

30 Microfluidics↗

Impact of crowding on the diversity of expanding populations

Crowding effects critically impact the self-organization of densely packed cellular assemblies, such as biofilms, solid tumors, and developing tissues. When cells grow and divide, they push each other apart, remodeling the structure and extent of the population’s range. Recent work has shown that crowding has a strong impact on the strength of natural selection. However, the impact of crowding on neutral processes, which controls the fate of new variants as long as they are rare, remains unclear. Here, we quantify the genetic diversity of expanding microbial colonies and uncover signatures of crowding in the site frequency spectrum. By combining Luria–Delbrück fluctuation tests, lineage tracing in a novel microfluidic incubator, cell-based simulations, and theoretical modeling, we find that the majority of mutations arise behind the expanding frontier, giving rise to clones that are mechanically “pushed out” of the growing region by the proliferating cells in front. These excluded-volume interactions result in a clone-size distribution that solely depends on where the mutation first arose relative to the front and is characterized by a simple power law for low-frequency clones. Our model predicts that the distribution depends on a single parameter—the characteristic growth layer thickness—and hence allows estimation of the mutation rate in a variety of crowded cellular populations. Combined with previous studies on high-frequency mutations, our finding provides a unified picture of the genetic diversity in expanding populations over the whole frequency range and suggests a practical method to assess growth dynamics by sequencing populations across spatial scales.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid crystal torons in Poiseuille-like flows

Three-dimensional (3D) simulations of the structure of liquid crystal (LC) torons, topologically protected distortions of the LC director field, under material flows are rare but essential in microfluidic applications. Here, we show that torons adopt a steady-state configuration at low flow velocity before disintegrating at higher velocities, in line with experimental results. Furthermore, we show that under partial slip conditions at the boundaries, the flow induces a reversible elongation of the torons, also consistent with the experimental observations. These results are in contrast with previous simulation results for 2D skyrmions under similar flow conditions, highlighting the need for a 3D description of this LC soliton in relation to its coupling to the material flow. These findings pave the way for future studies of other topological solitons, like hopfions and heliknotons, in flowing soft matter systems.

Science & Technology - Other Topics↗

Fluid inertia controls mineral precipitation and clogging in pore to network-scale flows

Mineral precipitation caused by fluid mixing presents complex control and predictability challenges in a variety of natural and engineering processes, including carbon mineralization, geothermal energy, and microfluidics. Precipitation dynamics, particularly under the influence of fluid flow, remain poorly understood. Combining microfluidic experiments and three-dimensional reactive transport simulations, we demonstrate that fluid inertia controls mineral precipitation and clogging at flow intersections, even in laminar flows. We observe distinct precipitation regimes as a function of Reynolds number (Re). At low Reynolds numbers (Re < 10), precipitates form a thin, dense layer along the mixing interface, which shuts precipitation off, while at high Reynolds numbers (Re > 50), strong three-dimensional flows significantly enhance precipitation over the entire intersection, resulting in rapid clogging. When injection rates from two inlets are uneven, flow symmetry-breaking leads to unexpected flow bifurcation phenomena, which result in enhanced concurrent precipitation in both downstream channels. Finally, we extend our findings to rough channel networks and demonstrate that the identified inertial effects on precipitation at the intersection scale are also present and even more dramatic at the network scale. This study sheds light on the fundamental mechanisms underlying mixing-induced mineral precipitation and provides a framework for designing and optimizing processes involving mineral precipitation.

Science & Technology - Other Topics↗

Genomic and Phenotypic Characterization of Yeast Biosensor for Deep-space Radiation

The BioSentinel mission was selected to launch as a secondary payload onboard NASA Exploration Mission 1 (EM-1) in 2018. In BioSentinel, the budding yeast Saccharomyces cerevisiae will be used as a biosensor to measure the long-term impact of deep-space radiation to living organisms. In the 4U-payload, desiccated yeast cells from different strains will be stored inside microfluidic cards equipped with 3-color LED optical detection system to monitor cell growth and metabolic activity. At different times throughout the 12-month mission, these cards will be filled with liquid yeast growth media to rehydrate and grow the desiccated cells. The growth and metabolic rates of wild-type and radiation-sensitive strains in deep-space radiation environment will be compared to the rates measured in the ground- and microgravity-control units. These rates will also be correlated with measurements obtained from onboard physical dosimeters. In our preliminary long-term desiccation study, we found that air-drying yeast cells in 10% trehalose is the best method of cell preservation in order to survive the entire 18-month mission duration (6-month pre-launch plus 12-month full-mission periods). However, our study also revealed that desiccated yeast cells have decreasing viability over time when stored in payload-like environment. This suggests that the yeast biosensor will have different population of cells at different time points during the long-term mission. In this study, we are characterizing genomic and phenotypic changes in our yeast biosensor due to long-term storage and desiccation. For each yeast strain that will be part of the biosensor, several clones were reisolated after long-term storage by desiccation. These clones were compared to their respective original isolate in terms of genomic composition, desiccation tolerance and radiation sensitivity. Interestingly, clones from a radiation-sensitive mutant have better desiccation tolerance compared to their original isolate without losing radiation sensitivity. We employed Next-Generation Sequencing technology to better understand this phenotypic variation. Current effort is focusing on the analysis of high-throughput sequencing data to look for genomic changes in these reisolated clones compared to their original isolate.

yeast↗

High-throughput single-cell sorting by stimulated Raman-activated cell ejection

Raman-activated cell sorting isolates single cells in a nondestructive and label-free manner, but its throughput is limited by small spontaneous Raman scattering cross section. Coherent Raman scattering integrated with microfluidics enables high-throughput cell analysis, but faces challenges with small cells (<3 μm) and tissue sections. Here, we report stimulated Raman-activated cell ejection (S-RACE) that enables high-throughput single-cell sorting by integrating stimulated Raman imaging, in situ image decomposition, and laser-induced cell ejection. S-RACE allows ejection of live bacteria or fungi guided by their Raman signatures. Furthermore, S-RACE successfully sorted lipid-richRhodotorula glutiniscells from a cell mixture with a throughput of ~13 cells per second, and the sorting results were confirmed by downstream quantitative polymerase chain reaction. Beyond single cells, S-RACE shows high compatibility with tissue sections. Incorporating a closed-loop feedback control circuit further enables real-time SRS imaging-identification-ejection. In summary, S-RACE opens exciting opportunities for diverse single-cell sorting applications.

Science & Technology - Other Topics↗

Miniaturized multiplex label-free electronic chip for rapid nucleic acid analysis based on carbon nanotube nanoelectrode arrays

BACKGROUND: Reducing cost and time is the major concern in clinical diagnostics, particularly in molecular diagnostics. Miniaturization technologies have been recognized as promising solutions to provide low-cost microchips for diagnostics. With the recent advancement in nanotechnologies, it is possible to further improve detection sensitivity and simplify sample preparation by incorporating nanoscale elements in diagnostics devices. A fusion of micro- and nanotechnologies with biology has great potential for the development of low-cost disposable chips for rapid molecular analysis that can be carried out with simple handheld devices. APPROACH: Vertically aligned multiwalled carbon nanotubes (MWNTs) are fabricated on predeposited microelectrode pads and encapsulated in SiO2 dielectrics with only the very end exposed at the surface to form an inlaid nanoelectrode array (NEA). The NEA is used to collect the electrochemical signal associated with the target molecules binding to the probe molecules, which are covalently attached to the end of the MWNTs. CONTENT: A 3 x 3 microelectrode array is presented to demonstrate the miniaturization and multiplexing capability. A randomly distributed MWNT NEA is fabricated on each microelectrode pad. Selective functionalization of the MWNT end with a specific oligonucleotide probe and passivation of the SiO2 surface with ethylene glycol moieties are discussed. Ru(bpy)2+ -mediator-amplified guanine oxidation is used to directly measure the electrochemical signal associated with target molecules. SUMMARY: The discussed MWNT NEAs have ultrahigh sensitivity in direct electrochemical detection of guanine bases in the nucleic acid target. Fewer than approximately 1000 target nucleic acid molecules can be measured with a single microelectrode pad of approximately 20 x 20 microm2, which approaches the detection limit of laser scanners in fluorescence-based DNA microarray techniques. MWNT NEAs can be easily integrated with microelectronic circuitry and microfluidics for development of a fully automated system for rapid molecular analysis with minimum cost.

Carbon↗

Label-free characterization of organic nanocarriers reveals persistent single molecule cores for hydrocarbon sequestration

Self-assembled molecular nanostructures embody an enormous potential for new technologies, therapeutics, and understanding of molecular biofunctions. Their structure and function are dependent on local environments, necessitating in-situ/operando investigations for the biggest leaps in discovery and design. However, the most advanced of such investigations involve laborious labeling methods that can disrupt behavior or are not fast enough to capture stimuli-responsive phenomena. We utilize X-rays resonant with molecular bonds to demonstrate an in-situ nanoprobe that eliminates the need for labels and enables data collection times within seconds. Our analytical spectral model quantifies the structure, molecular composition, and dynamics of a copolymer micelle drug delivery platform using resonant soft X-rays. We additionally apply this technique to a hydrocarbon sequestrating polysoap micelle and discover that the critical organic-capturing domain does not coalesce upon aggregation but retains distinct single-molecule cores. This characteristic promotes its efficiency of hydrocarbon sequestration for applications like oil spill remediation and drug delivery. Such a technique enables operando, chemically sensitive investigations of any aqueous molecular nanostructure, label-free.

36 MATERIALS SCIENCE↗

Atmospheric pressure plasmas interacting with wet and dry microchannels: reverse surface ionization waves

Atmospheric pressure plasma jets (APPJs) are increasingly being used to functionalize polymers and dielectric materials for biomedical and biotechnology applications. Once such application is microfluidic labs-on-a-chip consisting of dielectric slabs with microchannel grooves hundreds of microns in width and depth. The periodic channels, an example of a complex surface, present challenges in terms of directly and uniformly exposing the surface to the plasma. In this paper, we discuss results from computational and experimental investigations of negative APPJs sustained in Ar/N 2 mixtures flowing into ambient air and incident onto a series of microchannels. Results from two-dimensional plasma hydrodynamics modeling are compared to experimental measurements of electric field and fast-camera imaging. The propagation of the plasma across dry microchannels largely consists of a sequence of surface ionization waves (SIWs) on the top ridges of the channels and bulk ionization waves (IWs) crossing over the channels. The IWs are directed into electric field enhanced vertices of the next ridge. The charging of these ridges produce reverse IWs responsible for the majority of the ionization. The propagation of the plasma across water filled microchannels evolve into hopping SIWs between the leading edges of the water channels, regions of electric enhancement due to polarization of the water. Positive, reverse IWs follow the pre-ionized path of the initial negative waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗