Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys

An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing.

Weigand, A. J.↗

Release of microorganisms from soil with respect to transmission electron microscopy viewing and plate counts

A study was conducted to obtain information concerning the fate of soil microorganisms during the procedures normally used in separating them from the soil in connection with various types of investigations. A silty clay loam (pH 6.0, moisture content 25%, organic content 3.5%) was used in the study. The results of the study indicate that many of the microbial cells naturally residing in soil remain attached to or, for some other reason, are not separated from the soil debris despite the use of various combinations of blending, sonication, and chemical dispersing agents. The method B used by Balkwill et al. (1975) provides a reasonable electron microscopy evaluation of the soil microflora.

Balkwill, D. L.↗

Characterization of defect growth structure in ion plated films by scanning electron microscopy

Copper and gold films (0.2 to 2 microns) were ion plated onto polished 304-stainless-steel surfaces. These coatings were examined by scanning electron microscopy for coating growth defects. Three types of defects were distinguished: nodular growth, abnormal or runaway growth, and spits. The cause and origin for each type of defect was traced. Nodular growth is primarily due to inherent substrate microdefects, abnormal or runaway growth is due to external surface inclusions, and spits are due to nonuniform evaporation. All these defects have adverse effects on the coatings. They induce stresses and produce porosity in the coatings and thus weaken their mechanical properties. Friction and wear characteristics are affected by coating defects, since the large nodules are pulled out and additional wear debris is generated.

Spalvins, T.↗

Scanning microscopy in microcircuit failure analysis

A three-phase microcircuit failure analysis procedure is presented. In the first phase, the device is nondestructively tested and the data obtained is correlated with the circumstances surrounding the failure event. The device is then subjected to a limited nondestructive analysis dominated by optical and scanning electron microscopy (SEM). Knowing that microcircuits usually fail from manufacturing defects or misuse, the analyst looks for one of the probable mechanisms. The SEM has two special operating modes that provide unique data for nondestructive analysis: voltage contrast and conductive current. These are used with other SEM modes and surface analysis techniques to analyze complicated microcircuits. The last phase includes the destructive procedures. The end product of these analyses is a corrective action that will yield a highly reliable system.

Nicolas, D. P.↗

High resolution transmission electron microscopy of two stony meteorites - Murchison and Kenna

Matrix material from the Murchison C2(M) carbonaceous chondrite and less than micrometer-size pyroxene inclusions in an olivine from the Kenna ureilite have been characterized using high resolution transmission electron microscopy. A diversity of textures and mineral associations, including serpentine-type and brucite-type mixed-layering, occur in the Murchison matrix. Such mixed layer structures are new types of layer silicate. Their presence in the matrix may prove to be genetically significant. The Kenna inclusions, formed at the olivine grain margins, are of two types: (1) a disordered orthopyroxene-clinopyroxene which may have inverted from protopyroxene and (2) a pigeonite with narrow anti-phase domains (80 A to 250 A) and boundaries parallel to (100).

Mackinnon, I. D. R.↗

Holographic Microscopy System

Holographic system originally developed for testing theories of two systems used for measurements of aerosols, particles in transparent medium or microscopic biological specimens. Holograms are recorded in 3 - to 5milli-second exposures on high-resolution holographic film. In-line holographic microscopy system includes construction or recording system and reconstruction or playback system.

Witherow, W. K.↗

Acoustic microscopy of silicon carbide materials

It is shown that scanning laser acoustic microscopy (SLAM) is able to detect such fracture-controlling flaws in dense silicon carbide materials as surface voids, whose diameter-by-depth size is a minimum of 75 by 17 microns in reaction-bonded SiC and 68 by 25 microns in alpha-SiC. Surface conditions such as pitting, which have been found to limit the discernibility of drilled holes, become important when pit and drilled hole sizes become comparable.

Khandelwal, P. K.↗

Evaluation of solar cell welds by scanning acoustic microscopy

Scanning laser acoustic microscopy was used to nondestructively evaluate solar cell interconnect bonds made by resistance welding. Both copper-silver and silver-silver welds were analyzed. The bonds were produced either by a conventional parallel-gap welding technique using rectangular electrodes or new annular gap design with a circular electrode cross section. With the scanning laser acoustic microscope, it was possible to produce a real time television image which reveales the weld configuration as it relates to electrode geometry. The effect of electrode misalinement with the surface of the cell was also determined. A preliminary metallographic analysis was performed on selected welds to establish the relationship between actual size and shape of the weld area and the information available from acoustic micrographs.

Klima, S. J.↗

Mudrocks examined by backscattered electron microscopy

A method of studying mudrocks is developed using backscattered electrons (BSE) in scanning electron microscopy. Commercially available detectors are utilized to mix the BSE and secondary electron signals in order to obtain the optimum image for a particular material. Thin sections or polished rock chip surfaces are examined with BSE which provides both the atomic number contrast and topographic contrast. This technique provides very detailed information about the form and composition of individual grains in the mudrock thin sections and can be used in studies of the source, mode of deposition, diagenesis, and tectonic deformational history of mudrocks.

Pye, K.↗

Transmission electron microscopy characterization of microstructural features of Al-Li-Cu alloys

A transmission electron microscopy (TEM) examination of aluminum-lithium-copper alloys was conducted. The principal purpose is to characterize the nature, size, and distribution of stringer particles which result from the powder metallurgy (P/M) processing of these alloys. Microstructural features associated with the stringer particles are reported that help explain the stress corrosion susceptibility of the powder metallurgy-processed Al-Li-Cu alloys. In addition, matrix precipitation events are documented for a variety of heat treatments and process variations. Hot rolling is observed to significant alter the nature of matrix precipitation, and the observations are correlated with concomitant mechanical property variations.

Avalos-Borja, M.↗

Transmission electron microscopy of the 'LOW-CA' hydrated interplanetary dust particle

Transmission electron microscopy of a hydrated interplanetary dust particle indicates that it consists largely of a poorly crystalline phyllosilicate containing Fe, Mg and Al with an interlayer spacing of 10 to 12 A and so is distinct from the major phyllosilicate in CI and CM carbonaceous chondrites. The silicate is probably an Fe- and Mg-rich smectite or mica. Submicron, spherical to euhedral pyrrhotite and pentlandite are prominent. Unusual, low-Ni pentlandite is also common and typically occurs as rectangular platelets. Unlike many chondritic interplanetary dust particles, olivine is rare and pyroxene was not observed. Other less abundant phases are magnetite, chromite, and an unidentified phase containing Fe, Mg, Si, Ca, and Mn. This particle differs from a hydrated micrometeorite described previously by Brownlee (1978), indicating there are mineralogically different subsets of hydrated interplanetary dust particles. Despite gross similarities in mineralogy between the particle and the carbonaceous chondrites, they show appreciable differences in detail.

Tomeoka, K.↗

Reliability of void detection in structural ceramics using scanning laser acoustic microscopy

The reliability of scanning laser acoustic microscopy (SLAM) for detecting surface voids in structural ceramic test specimens was statistically evaluated. Specimens of sintered silicon nitride and sintered silicon carbide, seeded with surface voids, were examined by SLAM at an ultrasonic frequency of 100 MHz in the as fired condition and after surface polishing. It was observed that polishing substantially increased void detectability. Voids as small as 100 micrometers in diameter were detected in polished specimens with 0.90 probability at a 0.95 confidence level. In addition, inspection times were reduced up to a factor of 10 after polishing. The applicability of the SLAM technique for detection of naturally occurring flaws of similar dimensions to the seeded voids is discussed. A FORTRAN program listing is given for calculating and plotting flaw detection statistics.

Roth, D. J.↗

Transmission electron microscopy characterization of microstructural features in aluminum-lithium-copper alloys

A transmission electron microscopy (TEM) examination of aluminum-lithium-copper alloys was conducted. The principal purpose is to characterize the nature, size, and distribution of stringer particles which result from the powder metallurgy (P/M) processing of these alloys. Microstructural features associated with the stringer particles are reported that help explain the stress corrosion susceptibility of the powder metallurgy-processed Al-Li-Cu alloys. In addition, matrix precipitaton events are documented for a variety of heat treatments and process variations. Hot rolling is observed to significantly alter the nature of matrix precipitation, and the observations are correlated with concomitant mechanical property variations.

Avalos-Borja, M.↗

Molecular beam epitaxial growth and transmission electron microscopy studies of thin GaAs/InAs(100) multiple quantum well structures

GaAs/InAs(100) multiple interface structures involving 7.4 percent lattice mismatch have been fabricated via molecular beam epitaxy and examined via transmission electron microscopy. It is found that high-quality, dislocation-free interfaces involving such high lattice mismatch can indeed be experimentally realized for very thin layers provided proper care is given to achieve a balance between the growth kinetics and the thermodynamics leading to the equilibrium ground state of the strained layer. The compressive strain is homogeneously accommodated and a tetragonal distortion is induced in the InAs layer with a perpendicular lattice constant in close agreement with that expected on the basis of the continuum theory and elastic constants of bulk InAs.

Grunthaner, F. J.↗

Photoacoustic microscopy of ceramic turbine blades

Scanning photoacoustic microscopy (SPAM) is evaluated as a nondestructive technique for the detection of both surface and subsurface flaws in polycrystalline ceramics, such as those currently under consideration for the high temperature components of small vehicular and industrial gas turbine engines; the fracture strength of these brittle materials is controlled by small, 25-200 micron flaws. Attention is given to the correlation of SPAM-detected flaws with actual, fracture-controlling flaws in ceramic turbine blades.

Khandelwal, P. K.↗

Study of the Reactive-element Effect in Oxidation of Fe-cr Alloys Using Transverse Section Analytical Electron Microscopy

The role of trace additions of reactive elements like Y, Ce, Th, or Hf to Cr bearing alloys was studied by applying a new developed technique of transverse section analytical electron microscopy. This reactive-element effect improves the high temperature oxidation resistance of alloys by strongly reducing the high temperature oxidation rate and enhancing the adhesion of the oxide scale, however, the mechanisms for this important effect remain largely unknown. It is indicated that the presence of yttrium affects the oxidation of Fe-Cr-Y alloys in at least two ways. The reactive element alters the growth mechanism of the oxide scale as evidenced by the marked influence of the reactive element on the oxide scale microstructure. The present results also suggest that reactive-element intermetallic compounds, which internally oxidize in the metal during oxidation, act as sinks for excess vacancies thus inhibiting vacancy condensation at the scale-metal interface and possibly enhancing scale adhesion.

King, W. E.↗