Search NASA⌕ Search

SEARCH · Search NASA

Results for “microsphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Spatial distribution of venous gas emboli in the lungs

The distribution of gaseous pulmonary emboli is presumed to be determined by their buoyancy. We hypothesized that regional pulmonary blood flow may also influence their distribution. Therefore, pulmonary blood flow was measured in supine, anesthetized dogs with use of 15-microm fluorescent microspheres at baseline and during N(2) embolism. The animals were killed, and the lungs were excised, air-dried, and diced into approximately 2-cm(3) pieces with weights and spatial coordinates recorded. Embolism was defined as a >10% flow decrease relative to baseline. Vertically, the incidence of embolism increased substantially by 6 +/- 1% per additional centimeter in height compared with baseline (P = 0.0003). Embolism also increased radially by 3 +/- 1%/cm from the hilum (P = 0.002). There was a weaker but statistically significant increase in embolism to pieces with greater baseline flow, 9 +/- 2% for every 1. 0 increase in relative baseline flow (P = 0.008). We conclude that the distribution of gaseous emboli is influenced by buoyancy and flow dynamics within the pulmonary vasculature.

NASA Discipline Cardiopulmonary↗

Contribution of the vertebral artery to cerebral circulation in the rat snake Elaphe obsoleta

Blood supplying the brain in vertebrates is carried primarily by the carotid vasculature. In most mammals, cerebral blood flow is supplemented by the vertebral arteries, which anastomose with the carotids at the base of the brain. In other tetrapods, cerebral blood is generally believed to be supplied exclusively by the carotid vasculature, and the vertebral arteries are usually described as disappearing into the dorsal musculature between the heart and head. There have been several reports of a vertebral artery connection with the cephalic vasculature in snakes. We measured regional blood flows using fluorescently labeled microspheres and demonstrated that the vertebral artery contributes a small but significant fraction of cerebral blood flow (approximately 13% of total) in the rat snake Elaphe obsoleta. Vascular casts of the anterior vessels revealed that the vertebral artery connection is indirect, through multiple anastomoses with the inferior spinal artery, which connects with the carotid vasculature near the base of the skull. Using digital subtraction angiography, fluoroscopy, and direct observations of flow in isolated vessels, we confirmed that blood in the inferior spinal artery flows craniad from a point anterior to the vertebral artery connections. Such collateral blood supply could potentially contribute to the maintenance of cerebral circulation during circumstances when craniad blood flow is compromised, e.g., during the gravitational stress of climbing.

NASA Center ARC↗

Redistribution of pulmonary blood flow during unilateral hypoxia in prone and supine dogs

We used fluorescent-labeled microspheres in pentobarbital-anesthetized dogs to study the effects of unilateral alveolar hypoxia on the pulmonary blood flow distribution. The left lung was ventilated with inspired O2 fraction of 1.0, 0.09, or 0.03 in random order; the right lung was ventilated with inspired O2 fraction of 1.0. The lungs were removed, cleared of blood, dried at total lung capacity, then cubed to obtain approximately 1,500 small pieces of lung ( approximately 1.7 cm3). The coefficient of variation of flow increased (P < 0.001) in the hypoxic lung but was unchanged in the hyperoxic lung. Most (70-80%) variance in flow in the hyperoxic lung was attributable to structure, in contrast to only 30-40% of the variance in flow in the hypoxic lung (P < 0.001). When adjusted for the change in total flow to each lung, 90-95% of the variance in the hyperoxic lung was attributable to structure compared with 70-80% in the hypoxic lung (P < 0.001). The hilar-to-peripheral gradient, adjusted for change in total flow, decreased in the hypoxic lung (P = 0.005) but did not change in the hyperoxic lung. We conclude that hypoxic vasoconstriction alters the regional distribution of flow in the hypoxic, but not in the hyperoxic, lung.

NASA Discipline Cardiopulmonary↗

Pulmonary blood flow redistribution by increased gravitational force

This study was undertaken to assess the influence of gravity on the distribution of pulmonary blood flow (PBF) using increased inertial force as a perturbation. PBF was studied in unanesthetized swine exposed to -Gx (dorsal-to-ventral direction, prone position), where G is the magnitude of the force of gravity at the surface of the Earth, on the Armstrong Laboratory Centrifuge at Brooks Air Force Base. PBF was measured using 15-micron fluorescent microspheres, a method with markedly enhanced spatial resolution. Each animal was exposed randomly to -1, -2, and -3 Gx. Pulmonary vascular pressures, cardiac output, heart rate, arterial blood gases, and PBF distribution were measured at each G level. Heterogeneity of PBF distribution as measured by the coefficient of variation of PBF distribution increased from 0.38 +/- 0.05 to 0.55 +/- 0.11 to 0.72 +/- 0.16 at -1, -2, and -3 Gx, respectively. At -1 Gx, PBF was greatest in the ventral and cranial and lowest in the dorsal and caudal regions of the lung. With increased -Gx, this gradient was augmented in both directions. Extrapolation of these values to 0 G predicts a slight dorsal (nondependent) region dominance of PBF and a coefficient of variation of 0.22 in microgravity. Analysis of variance revealed that a fixed component (vascular structure) accounted for 81% and nonstructure components (including gravity) accounted for the remaining 19% of the PBF variance across the entire experiment (all 3 gravitational levels). The results are inconsistent with the predictions of the zone model.

NASA Discipline Cardiopulmonary↗

Granular two-phase insulation systems

Easily prepared system, consisting of matrix of hollow zirconia microspheres containing dispersed tungsten powder, produces minimum-cost, prototype test specimen. Combination represents basic concept of highly reflective dispersed phase in low density insulative matrix and is stable at 2200 K. Other combinations of materials are suggested.

Carpenter, H. W.↗

Test and evaluation of Apollo 14 composite casting demonstration specimens 6, 9, and 12, phase 1

Flight and control specimens 6, 9, and 12 from the Apollo 14 composite casting demonstration were evaluated with respect to the degree of dispersion achieved for mixtures of immiscible materials under one-gravity and low gravity environments. The flight and control capsules 6, 9, and 12 contained paraffin and sodium acetate; paraffin, sodium acetate and argon; and paraffin, sodium acetate and 100 micrometer diameter tungsten microspheres, respectively. The evaluation and documentation utilized photographic and microstructure examinations, density measurements, and droplet size and distribution determinations. In addition, theoretical analyses were performed in order to aid in the understanding of the fluid behavior of the specimens during processing and subsequent solidification. A comparison of evaluated data with the theoretical analyses reveals that although the immiscible materials were uniquely dispersed in a low gravity environment, nonuniform dispersions were obtained primarily due to insufficient initial mixing and an essentially unidirectional thermal gradient during cooldown.

Reger, J. L.↗

Flight-and ground-test evaluation of pyrrone foams

Two Pyrrone materials, pure Pyrrone foam with a density of 481 kg/cu m and hollow glass microsphere-Pyrrone composite with a density of 962 kg/cu m, were tested in the Langley 20-inch hypersonic arc heated tunnel at pressure levels from 0.06 to 0.27 atm and heating rates from 1.14 to 11.4 MW/sq m. The 481-kg/cu m Pyrrone foam was also flight tested as an experiment aboard a Pacemaker test vehicle. The results of the ground tests indicated that the thermal effectiveness of the 481-kg/cu m Pyrrone foam was superior to the 962-kg/cu m glass sphere-Pyrrone composite. The 481-kg/cu m Pyrrone foam had approximately one-half the thermal effectiveness of low density phenolic nylon. The 481-kg/cu m Pyrrone foam experienced random mechanical char removal over the entire range of test conditions. Char thermal property inputs for an ablation computer program were developed from the ground test data of the 481-kg/cu m Pyrrone foam. The computer program using these developed char thermal properties, as well as the measured uncharred material properties, adequately predicted the in-depth temperature histories measured during the Pacemaker flight.

Mclain, A. G.↗

Development of Pyrrone structural forms for honeycomb filler

The development of techniques for the preparation of Pyrrone structural foams for use as honeycomb filler is described. The feasibility of preparing foams from polymers formed by the condensation of 3,3'-diaminobenzidine (DAB), or 3,3',4,4'-tetraaminobenzophenone (TABP), with 3,3',4,4'-benzophenone tetracarboxylic dianhydride (BTDA) was investigated. Initially, most of the effort was devoted to preparing Pyrrone prepolymers with improved and more reproducible foaming properties for making chemically blown foams. When it became apparent that very high curing shrinkages would not allow the use of unfilled Pyrrone prepolymers in a foam-in-place process, emphasis was shifted from chemically blown foams to syntactic foams. Syntactic foam formulations containing hollow carbon microspheres were developed. Syntactic foams made from selected formulations were found to have very low coefficients of thermal expansion. A technique was developed for the emplacement of Pyrrone syntactic foam formulations in honeycomb core structures.

Kimmel, B. G.↗

Organic inclusions within hydrothermal minerals from S.W. Africa and elsewhere.

It was observed that quartz crystals from veins within a diabase dike of precambrian age from S.W. Africa contain organic particles which closely resemble, in detailed morphology, coacervates, proteinoid microspheres or fossil and recent microorganisms. The microphotospectrographs in visible and near-ultraviolet light of these minute particles revealed a strong absorption peak at the vicinity of 4000 A, which is indicative of lipids. Hydrothermal mineral from veins from a number of other localities proved to contain the biomorphic organic particles. The theoretical significance of these organic particles is discussed with reference to problems of origin of life.

Mueller, G.↗

Cushion module for stowing electronic equipment

To provide vibration-resistance composition adjust processing techniques, which produces essentially void-free materials and provides for clean removal of finished material from mold. Microsphere filler imparts strength to polymer and sodium carbonate imparts flame-resistance.

Rogers, J. R.↗

Soft, thermally conductive material

Silicon rubber filled with high percentage of silver-plated copper microspheres provides soft, thermally conductive seat for thermal switch. Material also could be used in thin sheet form to prevent corrosion between dissimilar metals while maintaining good thermal communication. It could be used as thermal gasketing.

Anderson, A. J.↗

Cryogenic thermal control technology summaries

A summarization and categorization is presented of the pertinent literature associated with cryogenic thermal control technology having potential application to in-orbit fluid transfer systems and/or associated space storage. Initially, a literature search was conducted to obtain pertinent documents for review. Reports determined to be of primary significance were summarized in detail. Each summary, where applicable, consists of; (1) report identification, (2) objective(s) of the work, (3) description of pertinent work performed, (4)major results, and (5) comments of the reviewer (GD/C). Specific areas covered are; (1) multilayer insulation of storage tanks with and without vacuum jacketing, (2) other insulation such as foams, shadow shields, microspheres, honeycomb, vent cooling and composites, (3) vacuum jacketed and composite fluid lines, and (4) low conductive tank supports and insulation penetrations. Reports which were reviewed and not summarized, along with reasons for not summarizing, are also listed.

Stark, J. A.↗