A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comments on Zihang Zhu, Shanghong Zhao, Xuan Li, and Kun Qu, Tao Lin, “Photonic generation of frequency-octupled microwave signal with reduced electrical local oscillator power and improved spectrum purity” Opt. Quant. Electron (2017)

In the title paper, Zhu et al. presented a technique for generating filter less frequency octo-tupling signal based on a cascade of two dual-polarization modulators. Firstly, the harmonics of order 4l (l in an integer) are generated in the x-polarization by driving the x-modulators with an RF signal with a 90° phase difference between the two stages. Then the carrier is suppressed using unmodulated y-polarization by means of polarization multiplexing. Accordingly, the demerit of their design is the requirement to reset a precise polarizer angle to suppress the optical carrier every time there is a change in the RF drive amplitude or the modulation index. Nevertheless, the authors claim superior performance to a similar architecture in which the y-branch is modulated with the proper RF drive phases to suppress the carrier for all drive levels with no need to adjust a splitting ratio. The aim of this comment is to show that by modulating the y-polarization with adjusted RF drive phases, same architecture can be used to perform frequency octo-tupling whose performance is neither limited by precise settings of the polarizer angle nor by the proper settings of the modulation index. The carrier is suppressed for a unique value of the polarizer angle for all modulation index. If the modulation index is adjusted to suppress the 4th harmonics, same circuit can be used to perform frequency 24-tupling generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of OMT-Coupled Kinetic Inductance Detector for CMB Detection

Future cosmic microwave background (CMB) experiments, including the large scale ground-based Stage Four CMB Experiment (CMB-S4), satellites, and balloons, aim to map the CMB to an unprecedented precision in order to answer several key questions in cosmology. However, to reach the target noise sensitivity, more than 100,000 detectors will be needed. Arrays of kinetic inductance detectors (KIDs) are a promising alternative for experiments that require large number of detectors due to the intrinsic multiplexing capabilities. We present the fabrication procedure for a prototype planar orthomode transducer (OMT)-coupled multi-color KID array optimized for 220/270 GHz frequency bands. These devices are made from silicon-on-insulator wafers to provide a low-loss substrate for the KIDs. The OMT couples the two polarizations of light from a wide-band feedhorn to separate Nb/SiN/Nb microstrip lines, which are then coupled to Al/Nb lumped-element KIDs (LEKIDs). The silicon on the backside of the OMT is etched away using deep reactive ion etch to release the OMT membrane to enable operation over a wide bandwidth. Finally, the buried oxide is removed underneath the KID capacitors in order to minimize two-level system noise and loss mitigation. We achieved a good yield (> 80%) on our prototype devices.

47 OTHER INSTRUMENTATION↗

A Search for Low-Mass Dark Matter with the Cryogenic Dark Matter Search and the Development of Highly Multiplexed Phonon-Mediated Particle Detectors

A wide variety of astrophysical observations indicate that approximately 85% of the matter in the universe is nonbaryonic and nonluminous. Understanding the nature of this "dark matter" is one of the most important outstanding questions in cosmology. Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter since they would be thermally produced in the early universe in the correct abundance to account for the observed relic density of dark matter. If WIMPs account for the dark matter, then rare interactions from relic WIMPs should be observable in terrestrial detectors. Recently, unexplained excess events in the DAMA/LIBRA, CoGeNT, and CRESST-II experiments have been interpreted as evidence of scattering from WIMPs with masses ~10 GeV and spin-independent scattering cross sections of 10-41-10-40 cm2. The Cryogenic Dark Matter Search (CDMS II) attempts to identify WIMP interactions using an array of cryogenic germanium and silicon particle detectors located at the Soudan Underground Laboratory in northern Minnesota. In this dissertation, data taken by CDMS II are reanalyzed using a 2 keV recoil energy threshold to increase the sensitivity to WIMPs with masses ~10 GeV. These data disfavor an explanation for the DAMA/LIBRA, CoGeNT, and CRESST-II results in terms of spin-independent elastic scattering of WIMPs with masses ≲12 GeV, under standard assumptions. At the time of publication, they provided the strongest constraints on spin-independent elastic scattering from 5-9 GeV, ruling out previously unexplored parameter space. To detect WIMPs or exclude the remaining parameter space favored by the most popular models will ultimately require detectors with target masses ≳1 ton, requiring an increase in mass by more than two orders of magnitude over CDMS II. For cryogenic detectors such as CDMS, scaling to such large target masses will require individual detector elements to be fabricated more quickly and cheaply, while maintaining the nearly background-free operation of the existing experiment. We describe the development of athermal phonon mediated particle detectors using Microwave Kinetic Inductance Detectors (MKIDs), which could provide a simpler path to extending the CDMS detector technology to the ton scale. Results from prototype devices have demonstrated energy resolutions as good as σ = 0.55 keV at 30 keV, comparable to existing CDMS II detectors. Such designs can be scaled to kg-scale detector elements, while reducing the complexity of the detector fabrication and cryogenic readout electronics relative to existing designs. Since MKIDs are naturally multiplexed in the frequency domain, MKID-based designs also allow much finer pixelization of the phonon sensor, which is expected to enhance background rejection for large detectors while simultaneously reducing the number of wires needed to read out the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developments of Highly Multiplexed, Multi-chroic Pixels for Balloon-Borne Platforms

We present our work to develop and characterize low thermal conductance bolometers that are part of sinuous antenna multi-chroic pixels (SAMP). We use longer, thinner and meandered bolometer legs to achieve 9 pW/K thermal conductance bolometers. We also discuss the development of inductor–capacitor chips operated at 4 K to extend the multiplexing factor of the frequency domain multiplexing to 105, an increase of 60% compared to the factor currently demonstrated for this readout system. This technology development is motivated by EBEX-IDS, a balloon-borne polarimeter designed to characterize the polarization of foregrounds and to detect the primordial gravity waves through their B-mode signature on the polarization of the cosmic microwave background. EBEX-IDS will operate 20,562 transition edge sensor bolometers spread over 7 frequency bands between 150 and 360 GHz. Balloon and satellite platforms enable observations at frequencies inaccessible from the ground and with higher instantaneous sensitivity. This development improves the readiness of the SAMP and frequency domain readout technologies for future satellite applications.

42 ENGINEERING↗

Horn-coupled, commercially-fabricated aluminum lumped-element kinetic inductance detectors for millimeter wavelengths

We discuss the design, fabrication, and testing of prototype horn-coupled, lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic microwave background studies. The LEKIDs are made from a thin aluminum film deposited on a silicon wafer and patterned using standard photolithographic techniques at STAR Cryoelectronics, a commercial device foundry. We fabricated 20-element arrays, optimized for a spectral band centered on 150 GHz, to test the sensitivity and yield of the devices as well as the multiplexing scheme. We characterized the detectors in two configurations. First, the detectors were tested in a dark environment with the horn apertures covered, and second, the horn apertures were pointed towards a beam-filling cryogenic blackbody load. These tests show that the multiplexing scheme is robust and scalable, the yield across multiple LEKID arrays is 91%, and the measured noise-equivalent temperatures for a 4 K optical load are in the range 26±6 μK√(s)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toric offset three-reflector antenna for the advanced microwave limb sounder

An advanced Microwave Limb Sounder (MLS), now in concept development for a potential future mission, is a space-borne heterodyne instrument to measure pressure, temperature, and atmospheric constituents from thermal emission between 120 and 2400 GHz. Previous MLS instruments used pencil-beam antennas sized to resolve N 1 vertical scale height. Current atmospheric models need better horizontal resolution than orbit spacing provides. To meet these needs, a new antenna concept combines the wide scan range of the parabolic torus with unblocked offset Cassegrain optics. The resulting system is diffraction-limited in the vertical plane but extremely astigmatic, with beamwidths 0.13~2.5. Nadir axis symmetry ensures that this Beam AspectRatio (BAR) is invariant over f33' of azimuth. The antenna can feed either an array of receivers or multiplexed low-noise receivers whose FOVs are swept by a small scanning mirror. We describe 3 stages of antenna design: First, using a paraxial-optics method, we choose conic profiles given vertical resolution orbit geometry, then develop the surfaces by nadir axis rotation, matching axisymmetric feeds to the BAR. A ray-trace program validates the design and generates alignment and deformation tolerances. Finally, a physical optics analysis verifies reflector surface currents and radiation patterns.

microwave↗

Atomic Layer Deposition Niobium Nitride Films for High-Q Resonators

Niobium nitride (NbN) is a useful material for fabricating detectors because of its high critical temperature and relatively high kinetic inductance. In particular, NbN can be used to fabricate nanowire detectors and mm-wave transmission lines. When deposited, NbN is usually sputtered, leaving room for concern about uniformity at small thicknesses. In this work, we present atomic layer deposition niobium nitride (ALD NbN) as an alternative technique that allows for precision control of deposition parameters such as film thickness, stage temperature, and nitrogen composition. Atomic-scale control over film thickness admits a high degree of uniformity for films 4–30 nm thick; control over deposition temperature gives rise to growth rate changes, which can be used to optimize film thickness and critical temperature. In order to charac- terize ALD NbN in the radio-frequency regime, we construct single-layer micro- wave resonators and test their performance as a function of stage temperature and input power. ALD processes can admit high resonator quality factors, with ≥ 43% of resonators above Q i = 10 6 , which in turn increase detector multiplexing capabilities. i Furthermore, we find critical temperatures in the range of 7.5–10.9 K that vary as a function of cycle count and deposition temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Transmon qubit readout fidelity at the threshold for quantum error correction without a quantum-limited amplifier

Abstract High-fidelity and rapid readout of a qubit state is key to quantum computing and communication, and it is a prerequisite for quantum error correction. We present a readout scheme for superconducting qubits that combines two microwave techniques: applying a shelving technique to the qubit that reduces the contribution of decay error during readout, and a two-tone excitation of the readout resonator to distinguish among qubit populations in higher energy levels. Using a machine-learning algorithm to post-process the two-tone measurement results further improves the qubit-state assignment fidelity. We perform single-shot frequency-multiplexed qubit readout, with a 140 ns readout time, and demonstrate 99.5% assignment fidelity for two-state readout and 96.9% for three-state readout–without using a quantum-limited amplifier.

Chen, Liangyu (ORCID:0000000250722445)↗

Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister

Many atmospheric research aircraft use a standard canister design to mount instruments, as this significantly facilitates their electrical and mechanical integration and thereby reduces cost. Based on more than 30 years of airborne science experience with the Microwave Temperature Profiler (MTP), the MTP has been repackaged with state-of-the-art electronics and other design improvements to fly in one of these standard canisters. All of the controlling electronics are integrated on a single 4 ~5-in. (.10 ~13- cm) multi-layer PCB (printed circuit board) with surface-mount hardware. Improved circuit design, including a self-calibrating RTD (resistive temperature detector) multiplexer, was implemented in order to reduce the size and mass of the electronics while providing increased capability. A new microcontroller-based temperature controller board was designed, providing better control with fewer components. Five such boards are used to provide local control of the temperature in various areas of the instrument, improving radiometric performance. The new stepper motor has an embedded controller eliminating the need for a separate controller board. The reference target is heated to avoid possible emissivity (and hence calibration) changes due to moisture contamination in humid environments, as well as avoiding issues with ambient targets during ascent and descent. The radiometer is a double-sideband heterodyne receiver tuned sequentially to individual oxygen emission lines near 60 GHz, with the line selection and intermediate frequency bandwidths chosen to accommodate the altitude range of the aircraft and mission.

Mahoney, Michael J.↗

Coherent lightwave communications; Proceedings of the Meeting, Boston, MA, Sept. 7, 8, 1989

Various papers on coherent lightwave communications are presented. Individual topics addressed include: overview of coherent light wave communications, frequency stabilization techniques for coherent lightwave systems, characterization of laser diode intensity noise at microwave frequencies with high sensitivity, FP and DFB semiconductor lasers with arbitrary external optical feedback, birefringence-controlled phase-shifter, polarization diversity and scrambling techniques for coherent systems, polarization control scheme for coherent optical systems, simulation of IF filtering effects on the performance of coherent optical receivers. Also discussed are: performance of optical DPSK receivers in the presence of optical channel noise, optical heterodyne communications with polarization modulation, coherent fiber optical subcarrier multiplexed system, engineered rack-mounted coherent transmission system, technology aspects of a coherent optical MAN, broadband exchange by coherent multicarrier switching, generalized temporal CDMA for optical communications. Overviews are given of recent progress at individual companies.

Sunak, Harish R. D.↗

Microwave Readout Techniques for Very Large Arrays of Nuclear Sensors

During this project, we transformed the use of microwave readout techniques for nuclear sensors from a speculative idea to reality. The core of the project consisted of the development of a set of microwave electronics able to generate and process large numbers of microwave tones. The tones can be used to probe a circuit containing a series of electrical resonances whose frequency locations and widths depend on the state of a network of sensors, with one sensor per resonance. The amplitude and phase of the tones emerging from the circuit are processed by the same electronics and are reduced to the sensor signals after two demodulation steps. This approach allows a large number of sensors to be interrogated using a single pair of coaxial cables. We successfully developed hardware, firmware, and software to complete a scalable implementation of these microwave control electronics and demonstrated their use in two areas. First, we showed that the electronics can be used at room temperature to read out a network of diverse sensor types relevant to safeguards or process monitoring. Second, we showed that the electronics can be used to measure large numbers of ultrasensitive cryogenic sensors such as gamma-ray microcalorimeters. In particular, we demonstrated the undegraded readout of up to 128 channels and established a path to even higher multiplexing factors. These results have transformed the prospects for gamma-ray spectrometers based on cryogenic microcalorimeter arrays by enabling spectrometers whose collecting areas and count rates can be competitive with high purity germanium but with 10x better spectral resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Polarbear-2 and the Simons Array experiments

Here, we present an overview of the design and status of the POLARBEAR-2 and the Simons Array experiments. POLARBEAR- 2 is a Cosmic Microwave Background polarimetry experiment which aims to characterize the arc-minute angular scale B-mode signal from weak gravitational lensing and search for the degree angular scale B-mode signal from inflationary gravitational waves. The receiver has a 365 mm diameter focal plane cooled to 270 milli-Kelvin. The focal plane is filled with 7,588 dichroic lenslet-antenna coupled polarization sensitive Transition Edge Sensor (TES) bolometric pixels that are sensitive to 95 GHz and 150 GHz bands simultaneously. The TES bolometers are read-out by SQUIDs with 40 channel frequency domain multiplexing. Refractive optical elements are made with high purity alumina to achieve high optical throughput. The receiver is designed to achieve noise equivalent temperature of 5.8 µK CMB √s in each frequency band. POLARBEAR-2 will deploy in 2016 in the Atacama desert in Chile. The Simons Array is a project to further increase sensitivity by deploying three POLARBEAR-2 type receivers. The Simons Array will cover 95 GHz, 150 GHz and 220 GHz frequency bands for foreground control. The Simons Array will be able to constrain tensor-to-scalar ratio and sum of neutrino masses to σ(r) = 6×10 $-$3 at r = 0.1 and Σm ν (σ = 1) to 40 meV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

Focal Plane Arrays of Voltage-Biased Superconducting Bolometers

The 200-micrometer to 3-mm wavelength range has great astronomical and cosmological significance. Science goals include characterization of the cosmic microwave background, measurement of the Sunyaev-Zel'dovich effect in galaxy clusters, and observations of forming galaxies. Cryogenic bolometers are the most sensitive broadband detectors in this frequency range. Because single bolometer pixels are reaching the photon noise limit for many observations, the development of large arrays will be critical for future science progress. Voltage-biased superconducting bolometers (VSBs) have several advantages compared to other cryogenic bolometers. Their strong negative electrothermal feedback enhances their linearity, speed, and stability. The large noise margin of the SQUID readout enables multiplexed readout schemes, which are necessary for developing large arrays. In this paper, we discuss the development of a large absorber-coupled array, a frequency-domain SQUID readout multiplexer, and an antenna-coupled VSB design.

Myers, Michael J.↗

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

Wollack, Edward↗

The Primordial Inflation Polarization Explorer (PIPER)

The Primordial Inflation Polarization ExploreR (Piper) is a balloon-borne cosmic microwave background (CMB) polarimeter designed to search for evidence of inflation by measuring the large-angular scale CMB polarization signal. Bicep2 recently reported a detection of B-mode power corresponding to the tensor-to-scalar ratio r = 0.2 on approximately 2 degree scales. If the Bicep2 signal is caused by inflationary gravitational waves (IGWs), then there should be a corresponding increase in B-mode power on angular scales larger than 18 degrees. Piper is currently the only suborbital instrument capable of fully testing and extending the Bicep2 results by measuring the B-mode power spectrum on angular scales theta θ = approximately 0.6 deg to 90 deg, covering both the reionization bump and recombination peak, with sensitivity to measure the tensor-to-scalar ratio down to r = 0.007, and four frequency bands to distinguish foregrounds. Piper will accomplish this by mapping 85% of the sky in four frequency bands (200, 270, 350, 600 GHz) over a series of 8 conventional balloon flights from the northern and southern hemispheres. The instrument has background-limited sensitivity provided by fully cryogenic (1.5 K) optics focusing the sky signal onto four 32×40-pixel arrays of time-domain multiplexed Transition-Edge Sensor (TES) bolometers held at 140 milli-Kelvin. Polarization sensitivity and systematic control are provided by front-end Variabledelay Polarization Modulators (VPMs), which rapidly modulate only the polarized sky signal at 3 Hz and allow Piper to instantaneously measure the full Stokes vector (I,Q,U,0V) for each pointing. We describe the Piper instrument and progress towards its first flight.

polarimeter↗

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗