Search NASA⌕ Search

SEARCH · Search NASA

Results for “missing values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Cleaning Images with Gaussian Process Regression

Many approaches to astronomical data reduction and analysis cannot tolerate missing data: corrupted pixels must first have their values imputed. This paper presents astrofix, a robust and flexible image imputation algorithm based on Gaussian process regression. Through an optimization process, astrofix chooses and applies a different interpolation kernel to each image, using a training set extracted automatically from that image. It naturally handles clusters of bad pixels and image edges and adapts to various instruments and image types. For bright pixels, the mean absolute error of astrofix is several times smaller than that of median replacement and interpolation by a Gaussian kernel. We demonstrate good performance on both imaging and spectroscopic data, including the SBIG 6303 0.4 m telescope and the FLOYDS spectrograph of Las Cumbres Observatory and the CHARIS integral-field spectrograph on the Subaru Telescope.

42 ENGINEERING↗

Effect of interfacial lattice mismatch on bulk carrier concentration and band gap of InN

The issue of ambiguous values of the band gap (0.6 to 2 eV) of InN thin film in literature has been addressed by a careful experiment. We have grown wurtzite InN films by PA-MBE simultaneously on differently modified c-plane sapphire substrates and characterized by complementary structural and chemical probes. Our studies discount Mie resonances caused by metallic In segregation at grain boundaries as the reason for low band gap values ( Almost-Equal-To 0.6 eV) and also the formation of Indium oxides and oxynitrides as the cause for high band gap value ( Almost-Equal-To 2.0 eV). It is observed that polycrystallinity arising from azimuthal miss-orientation of c-oriented wurtzite InN crystals increases the carrier concentration and the band gap values. We have reviewed the band gap, carrier concentration, and effective mass of InN in literature and our own measurements, which show that the Moss-Burstein relation with a non-parabolic conduction band accounts for the observed variation of band gap with carrier concentration.

36 MATERIALS SCIENCE↗

Indications for Pelvic Nodal Treatment in Prostate Cancer Should Change. Validation of the Roach Formula in a Large Extended Nodal Dissection Series

Purpose: Previous studies have criticized the predicting ability of the Roach formula in assessing the risk of lymph node invasion (LNI) in contemporary patients with prostate cancer (PCa) due to a significant overestimation of LNI rates. However, all those studies included patients treated with limited pelvic lymph node dissection (PLND), which is associated with high rates of false negative findings. We hypothesized that the Roach formula is still an accurate tool for LNI predictions if an extended PLND (ePLND) is performed. Methods and Materials: We included 3,115 consecutive patients treated with radical prostatectomy and ePLND between 2000 and 2010 at a single tertiary referral center. Extended PLND consisted of removal of obturator, external iliac, and hypogastric lymph nodes. We externally validated the Roach formula by using the area under the receiver operating characteristics curve and calibration plot method. Moreover, we tested the performance characteristics of different formula-generated cutoff values ranging from 1% to 20%. Results: The accuracy of the Roach formula was 80.3%. The calibration showed only a minor underestimation of the LNI risk in high-risk patients (6.7%). According to the Roach formula, the use of 15% cut off would have allowed 74.2% (2,311/3,115) of patients to avoid nodal irradiation, while up to 32.7% (111/336) of all patients with LNI would have been missed. When the cut off was lowered to 6%, nodal treatment would have been spared in 1,541 (49.5%) patients while missing 41 LNI patients. The sensitivity, specificity, and negative predictive values associated with the 6% cut off were 87.9%, 54%, and 97.3%, respectively. Conclusions: The Roach formula is still accurate and does not overestimate the rate of LNI in contemporary prostate cancer patients if they are treated with ePLND. However, the recommended cut off of 15% would miss approximately one-third of patients with LNI. Based on our results, the cut off should be lowered to 6%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Looking For Value in All The Wrong Places. Toward Expanded Consideration of Green and High Performance Attributes in Non-residential Property Appraisals in the United States

Large numbers of commercial buildings have sought to improve their energy and environmental performance, with half of all leasable U.S. offices now designated at some level of “green”. All proper/es fall somewhere on the green/high-­performance spectrum (above and below average) whether or not they bear a formal label or ra/ng.1 Variations in the level of performance can either positively or negatively influence value. This component of value can be shaped by many factors, from utility costs to tenant/owner preferences that translate into income (rent levels, vacancy rates, lease-­up /mes, etc.). Occupant perceptions of indoor environmental quality are another potential influence on value. While there has been little uptake of this thinking by practicing appraisers, the increased prevalence of green/HP practices combined with concerns about appraiser competency are compelling the industry to adapt their traditional techniques to this new driver of value. However, the overly narrow focus of policymakers on appraisal of labeled or rated exemplary buildings (e.g., LEED or ENERGY STAR Certified) represents a significant missed opportunity. Any level of green or energy performance can in fact influence value, including below-­average performance (a.k.a. “brown discount”), irrespec/ve of whether or not the building has been formally rated. Another surmountable challenge is the limitations to non-­appraisers’ understanding of the appraisal process (and constraints therein). A crucial byproduct of this is unrealistic expectations of what appraisers can and will do in the marketplace. This report identifies opportunities for catalyzing improvement of the green/HP appraisal process, which apply to all involved actors—from owner, report-­ordering client, the appraiser, and the appraisal reviewer—and fostering more demand for appraisals that recognize green/HP property attributes. The intended audience is primarily the public policy community and other stakeholders outside the formal appraisal community who can contribute to the broader effort to advance professional practces. The discussion begins with a descripton of the appraisal process and the points at which green/HP consideratons can enter the analysis. A series of major barriers to better practces are identfied along with approaches to reducing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AIS-based characterization of navigation conflicts along the US Atlantic Coast prior to development of wind energy

This study characterizes navigation conflicts in a region with a large traffic volume along the US Atlantic Coast, utilizing Automated Identification System (AIS) data for 2010. The region includes areas proposed for wind energy development. The characterization could be useful in evaluating the effect of offshore wind areas on navigation conflicts. The study processes the AIS data to provide pairwise comparisons of vessel interactions (encounters and near-misses) as they occurred. Using the vessel encounter data, analyses are made using a ‘blind’ vessel assumption to evaluate the potential for both near-misses and collisions. Then statistical analyses are made to estimate the point values and uncertainty for each type of encounter (crossing, head-on, overtaking). Examination of the frequency/number of collisions from actual observations is made. The examination of actual near-misses, potential near-misses, and potential collisions provides comparable results in the number of near-misses and collisions. The potential near-miss analyses include an examination of the timing of responses made by vessels to prevent near-misses. This informed the statistical analysis but may also have utility in the simulation of navigation conflicts.

99 GENERAL AND MISCELLANEOUS↗

Assessment of BSRN radiation records for the computation of monthly means

The accuracy of the Baseline Surface Radiation Network (BSRN) radiation monthly averages are assessed by investigating data gap frequency due to missing or discarded high time resolution data. The monthly statistics, especially means are considered to be important and useful values for climate research, model performance evaluations and for assessing the quality of satellite computations. The study investigates the spread in different algorithms that have been applied for the computation of monthly means from minute values. We found that a substantial fraction of the radiation fluxes observed at BSRN sites is either missing or flagged as questionable. The percentage of missing data is 4.4%, 13.0%, and 6.5% for global radiation, direct shortwave radiation, and downwelling longwave radiation, respectively. Most flagged data in the shortwave are due to nighttime instrumental noise and can reasonably be set to zero after correcting for thermal offsets in the daytime data. The paper reveals that the computation of monthly means from 1-minute observations distinctly depends on the selected method. The intra-method difference generally increases with an increasing fraction of missing data. The study demonstrates that the handling of flagged data clearly impacts on monthly mean estimates obtained with different methods. We showed that the spread of monthly shortwave fluxes are generally clearly higher than for downwelling longwave radiation. Overall, BSRN observation provide sufficient accuracy and completeness for reliable estimates of monthly mean values. However, we should aim at further increasing the data quality by reducing the data gap frequency and the number of outliers. The authors suggest using a standardized method for the computation of monthly means in order to avoid a mismatch of published monthly mean radiation fluxes from BSRN.

54 ENVIRONMENTAL SCIENCES↗

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype detector for the Deep Underground Neutrino Experiment (DUNE)'s Near Detector. Both the 2x2 Demonstrator and the Near Detector itself will have inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are positioned in-between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional (3D) grid for each track. Inactive regions within the tracks are replaced with a dense, rectangular 3D grid of voxels, ensuring consistent step sizes in X, Y, and Z directions. Voxels in these dense regions are initialized with an energy value of -1, indicating nonphysical energy or charge. The model is trained to predict which voxels should activate as part of the track and which should not, with the goal of eventually inferring the missing charge or energy values in these voxels. Results indicate that the model accurately predicts track voxels within ±1 unit in X, Y, or Z directions and effectively identifies non-track voxels, despite some overprediction. The approach shows promise in prediction of missing track regions with some accuracy.

43 PARTICLE ACCELERATORS↗

Predicting Missing Regions in Charged Particle Tracks Using a Sparse 3D Convolutional Neural Network

The 2x2 Demonstrator is a prototype detector for the Deep Underground Neutrino Experiment (DUNE)'s Near Detector. Both the 2x2 Demonstrator and the Near Detector itself will have inactive regions wherein there is no sensitivity to charge deposition and light signals that arise from charged particle interactions with liquid argon. In the 2x2, these inactive regions are positioned in-between the active detector modules, which introduces the challenge of inferring what charge signals ought to look like in these regions. This study explores the use of a Sparse 3D Convolutional Neural Network (ConvNet) to infer missing regions in charged particle tracks. Hits corresponding to energy depositions are voxelized into a three-dimensional (3D) grid for each track. Inactive regions within the tracks are replaced with a dense, rectangular 3D grid of voxels, ensuring consistent step sizes in X, Y, and Z directions. Voxels in these dense regions are initialized with an energy value of -1, indicating nonphysical energy or charge. The model is trained to predict which voxels should activate as part of the track and which should not, with the goal of eventually inferring the missing charge or energy values in these voxels. Results indicate that the model accurately predicts track voxels within 1 unit in X, Y, or Z directions and effectively identifies non-track voxels, despite some overprediction. The approach shows promise in prediction of missing track regions with some accuracy.

Utaegbulam, Hilary↗

From Layered Antiferromagnet to 3D Ferromagnet: LiMnBi-to-MnBi Magneto-Structural Transformation

Here, the intermetallic compound LiMnBi was synthesized by the two-step solid-state reaction from the elements. The synthesis temperature of 850 K was selected based on in-situ high-temperature powder X-ray diffraction data. LiMnBi crystalizes in the layered-like PbClF structure type (a = 4.3131(7) Å, c = 7.096(1) Å at 100 K, P4/nmm space group, Z = 2). LiMnBi structure is built of the alternating [MnBi] and Li layers, as determined from single-crystal X-ray diffraction data. Magnetic properties measurements and solid-state 7 Li Nuclear Magnetic Resonance data collected for polycrystalline LiMnBi samples indicate the long-range antiferromagnetic ordering of Mn sublattice at ~340 K, with no superconductivity down to 5 K detected. LiMnBi is air- and water-sensitive. In aerobic conditions, Li can be extracted from LiMnBi structure to form Li 2 O/LiOH and MnBi (NiAs structure type, P6 3 /mmc). The obtained MnBi polymorph was previously reported to be one of the strongest rare-earth-free ferromagnets, yet its bulk synthesis in powder form is cumbersome. The proposed magneto-structural transformation from ternary LiMnBi to ferromagnetic MnBi involves condensation of the MnBi4 tetrahedra upon Li deintercalation and is exclusive to LiMnBi. In contrast, ferromagnetic MnBi cannot be obtained from either isostructural NaMnBi and KMnBi, or from the structurally related CaMn 2 Bi 2 . Such a distinctive transformation in the case of LiMnBi is presumed to be due to its fitting reactivity to yield MnBi and favorable interlayer distance between [MnBi] layers, while the interlayer distance in NaMnBi and KMnBi structural analogs is unfavorably long. The studies of delithiation from the layered-like LiMnBi under different chemical environments indicate that the yield of the MnBi depends on the type of solvent used and the kinetics of the reaction. A slow rate and mild reaction media lead to a high fraction of the MnBi product. The saturation magnetization of the “as-prepared” MnBi is ~50 % of the expected value of 81.3 emu/g. Overall, this study adds a missing member to the family of ternary pnictides and illustrates how soft-chemistry methods can be used to obtain “difficult-to-synthesize” compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel adaptive discrete cosine transform-domain filter for gap-inpainting of high resolution PET scanners

Purpose: Several positron emission tomography (PET) scanners with special detector block arrangements have been developed in recent years to improve the resolution of PET images. However, the discontinuous detector blocks cause gaps in the sinogram. This study proposes an adaptive discrete cosine transform-based (aDCT) filter for gap-inpainting. Methods: The gap-corrupted sinogram was morphologically closed and subsequently converted to the DCT domain. A certain number of the largest coefficients in the DCT spectrum were identified to determine the low-frequency preservation region. The weighting factors for the remaining coefficients were determined by an exponential weighting function. The aDCT filter was constructed and applied to two digital phantoms and a simulated phantom introduced with various levels of noise. Results: For the Shepp-Logan head phantom, the aDCT filter filled the gaps effectively. For the Jaszczak phantom, no secondary artifacts were induced after aDCT filtering. The percent mean square error and mean structure similarity of the aDCT filter were superior to those of the DCT2 filter at all noise levels. For the simulated striatal dopamine innervation study, the aDCT filter recovered the shape of the striatum and restored the striatum to reference activity ratios to the ideal value. Conclusions: The proposed aDCT filter can recover the missing gap data in the sinogram and improve the image quality and quantitative accuracy of PET images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for supersymmetry with jets, missing transverse momentum and at least one hadronically decaying τ lepton in proton-proton collisions at s = 7 TeV with the ATLAS detector

Data from a search for the production of SUSY particles in proton-proton interactions at a centre of mass of 7 TeV using final states contianing jets, missing transverse momentum and at least one hadronically decaying tau lepton. The data, collected between March and April 2011, has a total integrated luminosity of 2.05 +- 0.08 fb-1. The trigger required at least one jet with PT > 75 GeV and missing PT > 45 GeV. As well as the numerical values of the plots in the paper, this record lists the acceptances, efficiences, and other signal data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Value of Faster Computation for Power Grid Operation

As a result of the grid evolution meeting the information revolution, the power grid is becoming far more complex than it used to be. How to feed data in, perform analysis, and extract information in a real-time manner is a fundamental challenge in today’s power grid operation, not to mention the significantly increased complexity in the smart grid environment. Therefore, high performance computing (HPC) becomes one of the advanced technologies used to meet the requirement of real-time operation. This paper presents benefit case studies to show the value of fast computation for operation. Two fundamental operation functions, state estimation (SE) and contingency analysis (CA), are used as examples. In contrast with today’s tools, fast SE can estimate system status in a few seconds—comparable to measurement cycles. Fast CA can solve more contingencies in a shorter period, reducing the possibility of missing critical contingencies. The benefit case study results clearly show the value of faster computation for increasing the reliability and efficiency of power system operation.

high performance computing↗

MO-G-BRE-05: Clinical Process Improvement and Billing in Radiation Oncology: A Case Study of Applying FMEA for CPT Code 77336 (continuing Medical Physics Consultation)

Purpose: The improvement of quality in healthcare can be assessed by Failure Mode and Effects Analysis (FMEA). In radiation oncology, FMEA, as applied to the billing CPT code 77336, can improve both charge capture and, most importantly, quality of the performed services. Methods: We created an FMEA table for the process performed under CPT code 77336. For a given process step, each member of the assembled team (physicist, dosimetrist, and therapist) independently assigned numerical values for: probability of occurrence (O, 1–10), severity (S, 1–10), and probability of detection (D, 1–10) for every failure mode cause and effect combination. The risk priority number, RPN, was then calculated as a product of O, S and D from which an average RPN was calculated for each combination mentioned above. A fault tree diagram, with each process sorted into 6 categories, was created with linked RPN. For processes with high RPN recommended actions were assigned. 2 separate R and V systems (Lantis and EMR-based ARIA) were considered. Results: We identified 9 potential failure modes and corresponding 19 potential causes of these failure modes all resulting in unjustified 77336 charge and compromised quality of care. In Lantis, the range of RPN was 24.5–110.8, and of S values – 2–10. The highest ranking RPN of 110.8 came from the failure mode described as “end-of-treatment check not done before the completion of treatment”, and the highest S value of 10 (RPN=105) from “overrides not checked”. For the same failure modes, within ARIA electronic environment with its additional controls, RPN values were significantly lower (44.3 for end-of-treatment missing check and 20.0 for overrides not checked). Conclusion: Our work has shown that when charge capture was missed that also resulted in some services not being performed. Absence of such necessary services may result in sub-optimal quality of care rendered to patients.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Daily, 30 m Resolution NDSI Data for the East River Watershed, CO for 2000-2020

This dataset contains daily Normalized Difference Snow Index (NDSI) values at 30 m spatial resolution for the East River watershed in Colorado, USA. The temporal range of these data includes water years 2001-2020. These data were created using the Spatial and Temporal Adaptive Reflectance Fusion Model (STARFM). This model fuses low spatial and high temporal resolution data from MODIS (500 m, daily) with high spatial and low temporal resolution data from Landsat (30 m, 16 days) to create a 30m synthetic daily snow product. This product allows for the analysis of historical snow covered area trends in the East River Watershed at fine spatiotemporal resolutions where it was not available previously. This research was performed as a part of the Department of Energy’s Subsurface Biogeochemical Research Program with the primary intent of better understanding the timing and spatial patterns of water delivery to the Critical Zone in mountain watersheds. Each .zip file contains one "water year" of data (October 1 - September 30; i.e., water year 2010 starts October 1, 2010 and ends September 30, 2011). Each zip file contains the following: STARFM daily Normalized Difference Snow Index (NDSI) fusion data files in GeoTiff format with one layer for each day between Landsat data acquisition dates (i.e., for dates of Landsat acquisition, the Landsat image is included for that date). The study area is located in an area of Landsat path overlap, so Landsat dates acquisitions are every 7-9 days. Landsat NDSI files containing the high spatial (30m), low temporal (7-9 days due to Landsat path overlap) resolution data used as input to STARFM in GeoTiff format with one layer for each day. Dates for which no Landsat data were obtained are included as NoData layers. MODIS NDSI files containing the high temporal (daily), low spatial (500m) resolution data used as input to STARFM in GeoTiff format with one layer for each day. Please note the MODIS data were resampled to 30m pixels for input into the STARFM model. The data have a scale factor of 10,000 and a no data value of -32767. The projection of all datasets is WGS 84 (EPSG: 4326), which has a latitude/longitude based degree resolution of 0.0002694946 X 0.0002694946, and approximates to the 30 m spatial resolution mentioned above. The Layer Index files in .csv format. They contain information for each layer in the above GeoTiff files regarding the corresponding date for each layer, the fraction of pixels in the image that contain valid data (missing data is due to either cloud cover or poor data quality; these values are not percent snow cover). Dates of Landsat overpass are indicated in these files. If no Landsat data were able to be obtained due to cloud cover or lack of Landsat Tier 1 data available on Google Earth Engine, this is also noted.

EARTH SCIENCE > CRYOSPHERE > SNOW/ICE↗

Low temperature magneto-dielectric measurements on BiFeO{sub 3} lightly substituted by cobalt

Dielectric and magnetodielectric measurements are done on BiFe{sub 1−x}Co{sub x}O{sub 3}: x = 0, 0.01, and 0.02 in the temperature range 70–300 K and up to magnetic field 1.3 T. The dielectric data are well described by Haverliak–Negami expression plus an additional term for the Maxwell Wagner (MW) type relaxations, whose contribution is dominant near room temperature. The parameters obtained from the fitting of data using the above mentioned expression, suggest slowing down of relaxation and approach towards ideal Debye type relaxations, as the temperature is lowered. The dielectric relaxations obey polaronic variable range hopping model with distinct activation energies (E{sub a}) in the extrinsic (6.67T{sup 3/4 }meV) and intrinsic (2.88T{sup 3/4 }meV) regions for the parent sample (x = 0), and thus a distinct transition from extrinsic to intrinsic behavior is seen at 215 K while lowering the temperature. This distinct transition is missing for Co substituted samples probably due to the extrinsic region values of E{sub a} (3.42T{sup 3/4 }meV and 2.42T{sup 3/4 }meV for x = 0.01 and 0.02, respectively) comparable to that of the intrinsic region (see x = 0). The magnetodielectric measurement shows positive magnetodielectricity (MD) in the intrinsic region (T < 215 K for x = 0) and negative MD in the extrinsic region (T > 215 K for x = 0). The extrinsic region is found to be dominated by MW and magnetoresistance effects, whereas MD in intrinsic regions is due to the spin reorientation transitions. The Co substitution is found to increase the extrinsic and non-Debye contributions to dielectricity, which becomes so large that no spin reorientation transitions are seen in x = 0.02 sample. The pyroelectric active region in x = 0 is found to be dominated by the diffusive behavior having contribution of the form ω{sup −0.5}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of new excited ${B} ^0_{s}$ states

A structure is observed in the ${B} ^{\pm }{K} ^{\mp }$ mass spectrum in a sample of proton–proton collisions at centre-of-mass energies of 7, 8, and 13 TeV, collected with the LHCb detector and corresponding to a total integrated luminosity of 9$\,\text {fb} ^{-1}$. The structure is interpreted as the result of overlapping excited ${B} ^0_{s}$ states. With high significance, a two-peak hypothesis provides a better description of the data than a single resonance. Under this hypothesis the masses and widths of the two states, assuming they decay directly to ${B} ^{\pm }{K} ^{\mp }$, are determined to be $\begin{aligned} m_1&= 6063.5 \pm 1.2 \text { (stat)} \pm 0.8\text { (syst)}\,\text {Me}\text {V}, \\ \Gamma _1&= 26 \pm 4 \text { (stat)} \pm 4\text { (syst)}\,\text {Me}\text {V}, \\ m_2&= 6114 \pm 3 \text { (stat)} \pm 5\text { (syst)}\,\text {Me}\text {V}, \\ \Gamma _2&= 66 \pm 18 \text { (stat)} \pm 21\text { (syst)}\,\text {Me}\text {V}. \end{aligned}$ Alternative values assuming a decay through ${B} ^{*\pm }{K} ^{\mp }$, with a missing photon from the $B^{*\pm } \rightarrow B^{\pm }\gamma $ decay, which are shifted by approximately 45 $\,\text {Me}$V, are also determined. The possibility of a single state decaying in both channels is also considered. The ratio of the total production cross-section times branching fraction of the new states relative to the previously observed $B_{s2}^{*0}$ state is determined to be $0.87 \pm 0.15 \text { (stat)} \pm 0.19 \text { (syst)}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Top-mass measurements from D0

We present three recent analyses (Abstracts 169, 170 and 174) of the mass of the top quark (M{sub t}) using top-antitop candidate events collected by the D0 experiment at the Fermilab Tevatron Collider: (i) a 3.6 events/fb sample of data in the lepton+jets channel analyzed to extract a precision value of M{sub t} using the 'Matrix-Element' (ME) method, wherein each event probability is calculated from the differential production cross section as a function of M{sub t} and the overall jet energy scale, with the latter constrained by the two jets from W decay into q{prime}{bar q}, (ii) a first measurement of the mass difference between top and antitop quarks as a check of CPT invariance in the quark sector, also based on the ME method in lepton+jets channels, and corresponding to a 1 event/fb data sample, and (iii) measurements of M{sub t} in dilepton final states (updated to 3.6 events/fb), based on 'matrix' weighting, 'neutrino' weighting and the ME method, which rely, respectively, on the likelihood of observing the events in data for a range of assumed M{sub t} values, distributions generated from event weights that compare calculated and reconstructed missing transverse energies, and event probabilities based on the leading-order differential cross section as a function of assumed M{sub t}. In addition, we provide a combination of recent top-mass measurements from D0.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NUBASE2016 evaluation of nuclear properties

This paper presents the NUBASE2016 evaluation that contains the recommended values for nuclear and decay properties of 3437 nuclides in their ground and excited isomeric (T1/2≥100 ns) states. All nuclides for which any experimental information is known were considered. NUBASE2016 covers all data published by October 2016 in primary (journal articles) and secondary (mainly laboratory reports and conference proceedings) references, together with the corresponding bibliographical information. During the development of NUBASE2016, the data available in the “Evaluated Nuclear Structure Data File” (ENSDF) database were consulted and critically assessed for their validity and completeness. Furthermore, a large amount of new data and some older experimental results that were missing from ENSDF were compiled, evaluated and included in NUBASE2016. The atomic mass values were taken from the “Atomic Mass Evaluation” (AME2016, second and third parts of the present issue). In cases where no experimental data were available for a particular nuclide, trends in the behavior of specific properties in neighboring nuclides (TNN) were examined. This approach allowed to estimate values for a range of properties that are labeled in NUBASE2016 as “non-experimental” (flagged “#”). Evaluation procedures and policies used during the development of this database are presented, together with a detailed table of recommended values and their uncertainties. AMDC: http://amdc.impcas.ac.cn/

Atomic Mass Evaluation (AME)↗