Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

JPL Contamination Control Engineering

JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/.

Molecular Contamination Spectral Effects (MCSE) Ch↗

To-date spacecraft applications and demonstration testing results, and future product development for new molecular adsorber technologies

The use of molecular adsorbers, in order to aid in the reduction of the spacecraft contamination levels, is discussed. Molecular adsorbers are characterized by an extremely large surface area, molecularly-porous substructure, and processing charged sites capable of retaining molecular contaminant species. Molecular adsorbers were applied on two Hubble Space Telescope servicing missions, as well as on the tropical rainfall measuring mission. The use of molecular adsorbers carries the potential for low cost, easy fabrication and integration of reliable means for reducing the contamination level around spacecraft.

Thomson, Shaun↗

The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

molecular contamination↗

Photolysis of spacecraft contaminants

A molecular beam facility, which was designed to measure photochemical cross-sections, has been constructed at the Athens College science facility. The integration of this vacuum system into an operational photochemical instrument was performed with signal processing consisting of both dc and ac techniques. Of the experiments performed to date on the vacuum ultraviolet photolysis of water vapor, it is apparent that a larger pumping capacity (preferably with differential pumping) is required to improve upon the background signal. Both phase-sensitive detection and ion-counting techniques are recommended for future studies.

Workman, G. L.↗

Applying Contamination Modelling to Spacecraft Propulsion Systems Designs and Operations

Molecular and particulate contaminants generated from the operations of a propulsion system may impinge on spacecraft critical surfaces. Plume depositions or clouds may hinder the spacecraft and instruments from performing normal operations. Firing thrusters will generate both molecular and particulate contaminants. How to minimize the contamination impact from the plume becomes very critical for a successful mission. The resulting effect from either molecular or particulate contamination of the thruster firing is very distinct. This paper will discuss the interconnection between the functions of spacecraft contamination modeling and propulsion system implementation. The paper will address an innovative contamination engineering approach implemented from the spacecraft concept design, manufacturing, integration and test (I&T), launch, to on- orbit operations. This paper will also summarize the implementation on several successful missions. Despite other contamination sources, only molecular contamination will be considered here.

Chen, Philip T.↗

Genesis Solar Wind Sample Curation: A Progress Report

In the year since the Genesis solar wind collector fragments were returned, early science samples, specimens for cleaning experiments, and science allocations have been distributed. Solar wind samples are stored under nitrogen and handled in an ISO Class 4 (Class 10) laboratory. For array collector fragments, a basic characterization process has been established. This characterization consists of identification of solar wind regime, whole fragment image for identification and surface quality, higher magnification images for contaminant particle density, and assessment of molecular film contaminant thickness via ellipsometry modeling. Compilations of this characterization data for AuOS (gold film on sapphire), and sapphire from the bulk solar wind for fragments greater than 2 cm are available. Removal of contaminant particles using flowing ultrapure water (UPW) energized megasonically is provided as requested.

Allton, Judith H.↗

Molecular Identification of Microbial Contaminants

Microorganisms can have significant impacts on the success of NASA’s missions, including the integrity of materials, the reliability of scientific results, and maintenance of crew health. Robust cleaning and sterilization protocols are currently in place in NASA facilities, but agency experts agree that microbial contamination is unavoidable and its impact on NASA’s missions and science must be minimized. Therefore, it is critical to understand: 1) what specific microorganisms are present, 2) how they may impact scientific objectives, and 3) how to select appropriate mitigation strategies. The Marshall Space Flight Center (MSFC) Planetary Protection (PP) microbiology lab historically relied solely upon enumeration of culturable microbial contamination associated with spacecraft materials or cleanrooms. However, this process is time consuming, many microbes cannot be cultured, and very few can be identified with any fidelity using NASA standard microbiological methods. The work described in this white paper includes the establishment of molecular identification capabilities at MSFC, including DNA isolation, amplification, purification, and Sanger sequencing. This capability will not only improve planetary protection efforts at MSFC (i.e. by identifying contaminating microorganisms in cleanrooms or on spacecraft) but also offers a service center-wide for the identification of contaminants that arise in other projects, processing locations, or during set up and roll out of spacecraft. This work also lays the foundation for higher throughput efforts to identify large populations of microbes across the lifetime of a project and serves as the starting point for future work into whole genome sequencing, non-culture based methods, or additional characterization studies. Ultimately, accurate identification informs appropriate mitigation strategies, increasing the chances of success for NASA’s missions and objectives.

C. D. Cassilly↗

Capabilities of the Materials Contamination Team at Marshall Space Flight Center

The Materials Contamination Team at the Marshall Space Flight Center (MSFC) has been recognized for its contributions supporting the National Aeronautics and Space Administration (NASA) spacecraft development programs. These programs include the Reusable Solid Rocket Motor (RSRM), Chandra X-Ray Observatory, and the International Space Station (ISS). The Environmental Effects Group, with the Materials Contamination Team and the Space Environmental Effects Team has been an integral part of NASA's success by the testing, evaluation, and qualification of materials, hardware, and processes. This paper focuses on the capabilities of the Materials Contamination Team. The Materials Contamination Team's realm of responsibility includes establishing contamination control during all phases of hardware development, including design, manufacturing, assembly, test, transportation, launch site processing, on-orbit exposure, return, and refurbishment. The team continues its mission of reducing the risk of equipment failure due to molecular or particulate contamination. Contamination is a concern in the Space Shuttle with sensitive bond-lines and reactive fluid (liquid oxygen) compatibility as well as for spacecraft with sensitive optics, such as Hubble Space Telescope and Chandra X-ray Observatory. The Materials Contamination Team has a variety of facilities and instrumentation capable of contaminant detection, identification, and monitoring. The team addresses material applications dealing with environments, including production facilities, clean rooms, and on-orbit exposure. The optically stimulated electron emission (OSEE) system, the Ultraviolet (UV) fluorescence (UVF) surface contamination detection, and the Surface Optics Corporation 400 (SOC 400) portable hand-held Fourier Transform Infrared (FTIR) spectrometer are state-of-the-art tools for in-process molecular contamination detection. The team of engineers and technicians also develop contamination calibration standards and evaluate new surface cleanliness inspection technologies. The team utilizes facilities for on-orbit simulation testing of materials for outgassing and molecular film deposition characteristics in the presence of space environmental effects, such as Atomic Oxygen (AO) and UV radiation exposure. The Materials Contamination Team maintains databases for process materials as well as outgassing and optical compatibility test results for specific environments.

Burns, Howard↗

Cleaning Surface Particle Contamination with Ultrapure Water (UPW) Megasonic Flow on Genesis Array Collectors

The hard landing experienced by the Genesis sample return capsule breached the science canister containing the solar wind collectors. This impact into the damp lakebed contaminated collector surfaces with pulverized collector and spacecraft materials and Utah sediment and brine residue. The gold foil, polished aluminum, and bulk metallic glass remained intact, but the solar wind bulk and regime-specific array collectors were jarred loose from their frames and fractured into greater than 10,000 specimens. After a year of investigation and cleaning experimentation, the Genesis Science Team determined that array collectors had 4 classes of contaminants: particles, molecular film, submicron inorganic particulate ("aerosol"), and pre-launch surface contamination. We discuss here use of megasonically energized ultrapure water (UPW) for removing particulate debris from array collector fragments.

Allton, J. H.↗

Evaluating the Adsorptive Capabilites of Chemsorb 1000 and Chemsorb 1425

The removal of trace contaminants from spacecraft cabin air is necessary for crew health and comfort during long duration space exploration missions. The air revitalization technologies used in these future exploration missions will evolve from current ISS ISS State-of-Art (SOA) and is being designed and tested by the Advanced Exploration Systems (AES) Program's Atmosphere Resource Recovery and Environmental Monitoring (ARREM) project. The ARREM project is working to mature optimum atmosphere revitalization and environmental monitoring system architectures to enable exploration beyond Lower Earth Orbit (LEO). The Air Revitalization Lab at KSC is one of six NASA field centers participating in the ARREM that specializes in adsorbent and catalyst characterization with simulated spacecraft gas streams using combinations of pressure, O2 partial pressure, CO2 partial pressure, and humidity that are representative of a range of anticipated cabin atmospheric conditions and loads. On board ISS, the Trace Contaminant Control Subassembly (TCCS) provides active control of trace contaminants from the cabin atmosphere utilizing physical adsorption, thermal catalytic oxidation, and chemical adsorption processes. High molecular weight contaminants and ammonia (NH3) are removed a granular activated carbon treated with approx. 10% by weight phosphoric acid (H3PO4) (B-S Type 3032 4×6 mesh), which is expendable and is periodically refurbished. The Type 3032 granular activated carbon bed is no longer commercially available and therefore it is important to characterize the efficiency and capacity of commercially available NH3 sorbents. This paper describes the characterization of two Molecular Products LTD activated carbons: Chemsorb 1000 and Chemsorb 1425. Untreated activated carbons (e.g. Chemsorb 1000) remove contaminants by physisorption, which concentrates the contaminant within the pores of the carbon while letting air to pass through the sorbent4. Low molecular weight or polar gases (e.g. HCl, SO2, formaldehyde, and NH3) are not removed by physisorption and typically require chemisorption for removal. Treated activated carbons (e.g. Chemsorb 1425) are impregnated with a a chemical agent (e.g. phosphoric acid) that reacts with those gases, converting them to solids or salts within the carbon and removes them from the air stream. This process occurs via neutralization or catalysis reactions and adsorption capacity is exhaustedwhen the available impregnated chemicals are consumed. Moisture affects removal performance since adsorption sites within the pores are filled with water. The performance of impregnated carbons may be enhanced by moisture content because the mechanisms of contaminant removal are chemical reactions that occur in reagents contained within the pores. The adsorptive capacity data (mol/kg) of Chemsorb 1000 and 1425 for gas mixtures (ethanol, acetone, toluene, acetaldehyde, dichloromethane, and xylene) was measured with 40% relative humidity at 23 deg C air temperature. The adsorptive capacity data (mol/kg) of Chemsorb 1425 was measured using NH3 gas streams.

adsorptive capacities↗

Organic contamination problems in the Viking molecular analysis experiment

A principal problem in interpreting the results of an organic analysis of an extraterrestrial sample is that of distinguishing contaminating material from indigenous material when unknown types and amounts of contaminants make their way into the sample being analyzed. An approach to control of sample integrity in the Viking molecular analysis experiment has been devised which it is believed, will eliminate such problems. Basically this involves (1) placing an upper limit on the amount of terrestrial contamination that can be tolerated and still allow scientifically meaningful analysis, (2) identifying the potential sources of contamination and analyzing their relative significance, (3) establishing methods to control these sources, and (4) obtaining complete information on the chemical composition of potential contaminants. Previous experience in the Apollo mission has been of great value in developing the Viking program, perhaps the most important carryover being the recognition of the importance of establishing a comprehensive contamination control program in the early stages of mission planning and hardware design.

Flory, D. A.↗

Transient Molecular Transfer During Vacuum Testing

A common question in contamination budgeting involves the loss of collected volatiles during ambient I&T activity under vacuum and the resultant cross-contamination from outgassing. (1) How much of the material collected under ambient conditions evaporates under vacuum? (2) Why do pristine surfaces sometimes show increased molecular contamination after vacuum bakeout? (3) How much of the collected molecular contamination is transient (i.e. migratory) and how much is permanent? Measuring the transient deposition may be accomplished using a thermally passive QCM

Perry, Radford L.↗

Space Shuttle contamination measurements from flights STS-1 through STS-4

Results of contamination measurements performed on the initial four flights of the Space Shuttle Orbiter are summarized and compared with requirements contained in the Space Shuttle Flight and Ground System Specifications and those formulated by the Contamination Requirements Definition Group. In general, the results of measurements carried out with the induced environment contamination monitor indicate that molecular fluxes, deposition rates, and average counts of particulates are within the requirements and close to predicted values. Among the exceptions, were such special circumstances as water dumps, payload bay door closures, and RCS engine, APU, and flash evaporator operations which led to molecular and particulate contamination levels exceeding the limits. In cases where these circumstances would interfere with sensitive payload operations, careful mission planning to preclude a contamination source by operational limitation should be done to avoid losses.

Ehlers, H. K. F.↗

Analytical Methods and Testbeds for Characterizing Adsorbents and Catalysts for Atmosphere Revitalization of Crewed Spacecraft

Spacecraft environmental control and life support systems (ECLSS) include a number of air revitalization (AR) technologies to provide breathable air and a comfortable living environment to the crew. Crew health and comfort is ensured by controlling human produced CO2 (1 kg person-1 day-1) and water vapor (~2 kg person-1 day-1), and by removing trace contaminants (TCs) from cabin air. These life support functions on-board the International Space Station (ISS) are carried out by the Carbon Dioxide Removal Assembly (CDRA), the Water Processor Assembly (WPA), and the trace contaminant control system (TCCS). During the development of the TCCS, new analytical and theoretical methods were developed in the 1970s for characterizing adsorption and desorption characteristics of activated carbons for the purpose of designing suitable AR technologies required for controlling airborne trace contaminants within spacecraft cabins during long exploration missions. The TCCS removes harmful volatile organic compounds and other trace contaminants from the circulating air. It consists of a granular activated carbon (GAC) bed for the removal of high molecular weight contaminants and ammonia followed by a heated catalytic bed for low molecular weight hydrocarbons. The high temperature catalytic oxidizer (HTCO) of the TCCS, which operates at 400°C and requires 120W average power, removes low molecular weight compounds such as carbon monoxide (CO), formaldehyde (CH2O), and methane (CH4), that pass through the GAC bed. The Air Revitalization Laboratory at the Kennedy Space Center (KSC) was established to develop new analytical methods for evaluating emerging ECLSS technologies for use in future AR architectures. General properties of adsorbents and catalysts are required for trace contaminant control system design calculations and vendor-supplied data are seldom available at relevant process conditions of interest to spacecraft cabin applications. To address this shortcoming, appropriate testbeds were developed to measure the desired properties of AR technologies being considered for use in ECLS architectures. Generally, the testbeds developed at KSC challenge the test media (activated carbon, impregnated activated carbon, catalysts, zeolites, solid amines, or pleated filters) with simulated spacecraft gas streams containing representative mixtures of trace contaminants (volatile organic compounds, ammonia, CO, CO2, or siloxanes) at the flow rates, temperatures, and relative humidity that will be encountered within manned spacecraft. Work performed at KSC funded by NASA’s Advanced Exploration (AES) Program has included: Identifying candidate sorbents to replace commercially obsolete impregnated carbons for NH3 control within the TCCS, characterizing their adsorptive capacities using simulated spacecraft gas streams, and ranking their appropriateness in various AR applications; evaluating novel low temperature catalysts for controlling CO and formaldehyde by traditional and photocatalytic methods for trace contaminant control; development of analytical methods to assess regenerable solid amine performance for CO2 control via pressure swing adsorption. The Air Revitalization lab was also funded to study trace contaminant control by other NASA programs. These include: screening of candidate sorbents for the design of new Charcoal HEPA Integrated Particle Scrubber (CHIPS) filters for removing siloxanes from cabin air; characterizing the performance of an impregnated activated carbon at low humidity for use in ORION ECLS; screening of sorbents for protecting the Sabatier 2.0 catalyst from DMSO2, siloxanes, NH3, and solid amine byproducts.

Monje, Oscar↗

Organic Contamination Baseline Study: In NASA JSC Astromaterials Curation Laboratories. Summary Report

In preparation for OSIRIS-REx and other future sample return missions concerned with analyzing organics, we conducted an Organic Contamination Baseline Study for JSC Curation Labsoratories in FY12. For FY12 testing, organic baseline study focused only on molecular organic contamination in JSC curation gloveboxes: presumably future collections (i.e. Lunar, Mars, asteroid missions) would use isolation containment systems over only cleanrooms for primary sample storage. This decision was made due to limit historical data on curation gloveboxes, limited IR&D funds and Genesis routinely monitors organics in their ISO class 4 cleanrooms.

Calaway, Michael J.↗

Contamination Effects Due to Space Environmental Interactions

Molecular and particulate contaminants are commonly generated from the orbital spacecraft operations that are under the influence of the space environment. Once generated, these contaminants may attach to the surfaces of the spacecraft or may remain in the vicinity of the spacecraft. In the event these contaminants come to rest on the surfaces of the spacecraft or situated in the line-of-sight of the observation path, they will create various degrees of contamination effect which may cause undesirable effects for normal spacecraft operations, There will be circumstances in which the spacecraft may be subjected to special space environment due to operational conditions. Interactions between contaminants and special space environment may alter or greatly increase the contamination effect due to the synergistic effect. This paper will address the various types of contamination generation on orbit, the general effects of the contamination on spacecraft systems, and the typical impacts on the spacecraft operations due to the contamination effect. In addition, this paper will explain the contamination effect induced by the space environment and will discuss the intensified contamination effect resulting from the synergistic effect with the special space environment.

Chen, Philip T.↗

Overview of the Lunar Gateway External Contamination Environment

As a part of the Artemis mission, Gateway will be a long duration space station in a near rectilinear halo orbit around the Moon. Gateway will be exposed to a variety of external contamination sources, which can degrade external hardware / surfaces and impact science utilization objectives. Requirements and methodologies addressing material outgassing, chemical and electric thruster plumes, vacuum venting, and visiting vehicle interactions have been developed by the Gateway Induced Environments team to ensure vehicle performance and mission success. The external contamination requirements and integration process are described along with required data deliverables. Integrated external contamination analyses are conducted by the Gateway Environments Team to assess compliance with external contamination requirements. This paper provides a current status of integration activities and analysis results, as well as future plans to improve external contamination characterization.

thruster plumes↗