Search NASA⌕ Search

SEARCH · Search NASA

Results for “monitored quantum systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quantum state specific reactant preparation in a molecular beam by rapid adiabatic passage

Highly efficient preparation of molecules in a specific rovibrationally excited state for gas/surface reactivity measurements is achieved in a molecular beam using tunable infrared (IR) radiation from a single mode continuous wave optical parametric oscillator (cw-OPO). We demonstrate that with appropriate focusing of the IR radiation, molecules in the molecular beam crossing the fixed frequency IR field experience a Doppler tuning that can be adjusted to achieve complete population inversion of a two-level system by rapid adiabatic passage (RAP). A room temperature pyroelectric detector is used to monitor the excited fraction in the molecular beam and the population inversion is detected and quantified using IR bleaching by a second IR-OPO. The second OPO is also used for complete population transfer to an overtone or combination vibration via double resonance excitation using two spatially separated RAP processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Limits on the UV Photodecomposition of Carbonates on Mars

The effect of UV (ultraviolet) light on the stability of calcium carbonate in a simulated martian atmosphere was experimentally investigated. Sample cells containing C-13 labeled calcite were irradiated with a Xe arc lamp in 10 mbar of simulated martian atmosphere and a quadrupole mass spectrometer was used to monitor the headspace gases for the production of (13)CO2. We found no experimental evidence of the UV photodecomposition of calcium carbonate in a simulated martian atmosphere. Extrapolating the lower limit of detection of our experimental system to an upper limit of carbonate decomposition on Mars yields a quantum efficiency of 3.5 x 10(exp -8) molecules/photon over the wavelength interval of 190-390 nm and a maximum UV photodecomposition rate of 1.2 x 10(exp -13) kg m(exp -2) s(exp -1) from a calcite surface. The maximum loss of bulk calcite due to this process would be 2.5 nm yr(exp -1). However, calcite is expected to be thermodynamically stable on the surface of Mars and potential UV photodecomposition reaction mechanisms indicate that while calcium carbonate may decompose under vacuum, it would be stable in a CO2 atmosphere. Given the expected stability of carbonate on Mars and our inability to detect carbonate decomposition, we conclude that it is unlikely that the apparent absence of carbonate on the martian surface is due to UV photo decomposition of calcite in the current environment.

Quinn, Richard↗

Low Cost, High Efficiency, High Pressure Hydrogen Storage

A technical and design evaluation was carried out to meet DOE hydrogen fuel targets for 2010. These targets consisted of a system gravimetric capacity of 2.0 kWh/kg, a system volumetric capacity of 1.5 kWh/L and a system cost of $4/kWh. In compressed hydrogen storage systems, the vast majority of the weight and volume is associated with the hydrogen storage tank. In order to meet gravimetric targets for compressed hydrogen tanks, 10,000 psi carbon resin composites were used to provide the high strength required as well as low weight. For the 10,000 psi tanks, carbon fiber is the largest portion of their cost. Quantum Technologies is a tier one hydrogen system supplier for automotive companies around the world. Over the course of the program Quantum focused on development of technology to allow the compressed hydrogen storage tank to meet DOE goals. At the start of the program in 2004 Quantum was supplying systems with a specific energy of 1.1-1.6 kWh/kg, a volumetric capacity of 1.3 kWh/L and a cost of $73/kWh. Based on the inequities between DOE targets and Quantum’s then current capabilities, focus was placed first on cost reduction and second on weight reduction. Both of these were to be accomplished without reduction of the fuel system’s performance or reliability. Three distinct areas were investigated; optimization of composite structures, development of “smart tanks” that could monitor health of tank thus allowing for lower design safety factor, and the development of “Cool Fuel” technology to allow higher density gas to be stored, thus allowing smaller/lower pressure tanks that would hold the required fuel supply. The second phase of the project deals with three additional distinct tasks focusing on composite structure optimization, liner optimization, and metal.

08 HYDROGEN↗

Downhole laser system with an improved laser output production and data collection

One or more embodiments relates to a method of growing ultrasmooth and high quantum efficiency CsTe photocathodes. The method includes exposing a substrate of Cs using an alkali source such as an effusion cell; and controlling co-evaporating growth and co-deposition forming a CsTe growth. The method further includes monitoring a stoichiometry of the CsTe growth.

Mcintyre, Dustin↗

Downhole laser system with an improved laser output production and data collection

One or more embodiments relates to a method of growing ultrasmooth and high quantum efficiency CsTe photocathodes. The method includes exposing a substrate of Cs using an alkali source such as an effusion cell; and controlling co-evaporating growth and co-deposition forming a CsTe growth. The method further includes monitoring a stoichiometry of the CsTe growth.

McIntyre, Dustin↗

Single heterostructure lasers of PbS/1-x/Se/x/ and Pb/1-x/Sn/x/Se with wide tunability

Single-heterostructure diode lasers formed by compositional interdiffusion (CID) and liquid-phase epitaxy (LPE) of lead salts are discussed. The CID technique, which involves creation of a single heterostructure in a pseudobinary compound having binary constituents with different vapor pressures, is reviewed; growth of lead-salt crystals of various compositions is described. Some electrical and optical characteristics, including properties indicative of high internal quantum efficiencies, are given for lasers which employ the CID and LPE diodes. High operating temperatures (i.e., liquid nitrogen levels and above), together with wide tuning ranges (a diode wavelength of 12.7 microns is reported), make the lasers useful in high-resolution spectrometry and advanced trace-gas monitoring systems.

Linden, K. J.↗

Theoretical Studies of Spectroscopic Line Mixing in Remote Sensing Applications

The phenomenon of collisional transfer of intensity due to line mixing has an increasing importance for atmospheric monitoring. From a theoretical point of view, all relevant information about the collisional processes is contained in the relaxation matrix where the diagonal elements give half-widths and shifts, and the off-diagonal elements correspond to line interferences. For simple systems such as those consisting of diatom-atom or diatom-diatom, accurate fully quantum calculations based on interaction potentials are feasible. However, fully quantum calculations become unrealistic for more complex systems. On the other hand, the semi-classical Robert-Bonamy (RB) formalism, which has been widely used to calculate half-widths and shifts for decades, fails in calculating the off-diagonal matrix elements. As a result, in order to simulate atmospheric spectra where the effects from line mixing are important, semi-empirical fitting or scaling laws such as the ECS (Energy-Corrected Sudden) and IOS (Infinite-Order Sudden) models are commonly used. Recently, while scrutinizing the development of the RB formalism, we have found that these authors applied the isolated line approximation in their evaluating matrix elements of the Liouville scattering operator given in exponential form. Since the criterion of this assumption is so stringent, it is not valid for many systems of interest in atmospheric applications. Furthermore, it is this assumption that blocks the possibility to calculate the whole relaxation matrix at all. By eliminating this unjustified application, and accurately evaluating matrix elements of the exponential operators, we have developed a more capable formalism. With this new formalism, we are now able not only to reduce uncertainties for calculated half-widths and shifts, but also to remove a once insurmountable obstacle to calculate the whole relaxation matrix. This implies that we can address the line mixing with the semi-classical theory based on interaction potentials between molecular absorber and molecular perturber. We have applied this formalism to address the line mixing for Raman and infrared spectra of molecules such as N2, C2H2, CO2, NH3, and H2O. By carrying out rigorous calculations, our calculated relaxation matrices are in good agreement with both experimental data and results derived from the ECS model.

Formalism↗

Quantum emitters dynamically coupled to a quantum field

We study theoretically the dynamical response of a set of solid-state quantum emitters arbitrarily coupled to a single-mode microcavity system. Ramping the matter-field coupling strength in round trips, we quantify the hysteresis or irreversible quantum dynamics. The matter-field system is modeled as a finite-size Dicke model which has previously been used to describe equilibrium (including quantum phase transition) properties of systems such as quantum dots in a microcavity. Here we extend this model to address non-equilibrium situations. Analyzing the system’s quantum fidelity, we find that the near-adiabatic regime exhibits the richest phenomena, with a strong asymmetry in the internal collective dynamics depending on which phase is chosen as the starting point. We also explore signatures of the crossing of the critical points on the radiation subsystem by monitoring its Wigner function; then, the subsystem can exhibit the emergence of non-classicality and complexity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of Thermoacoustic Power Sensor

The goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-cooled Fast Reactor (SFR), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactor (LFR), Molten Salt Reactor (MSR), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the detector network placed outside of the reactor vessel. These detectors require a very small amount of power which, during loss of power events, can be provided for example by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron radiation based beam diagnostics at the Fermilab Tevatron

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. Therefore, if one utilizes the radiation originating near the edge of a bending magnet, or from a short magnet, the rapidly changing magnetic field serves to enhance the wavelengths shorter than the cutoff wavelength, which for more recent high energy proton accelerators such as Fermilab's Tevatron, tends to be visible light. This paper discusses the implementation at the Tevatron of two devices. A transverse beam profile monitor images the synchrotron radiation coming from the proton and antiproton beams separately and provides profile data for each bunch. A second monitor measures the low-level intensity of beam in the abort gaps which poses a danger to both the accelerator's superconducting magnets and the silicon detectors of the high energy physics experiments. Comparisons of measurements from the profile monitor to measurements from the flying wire profile systems are presented as are a number of examples of the application of the profile and abort gap intensity measurements to the modelling of Tevatron beam dynamics.

43 PARTICLE ACCELERATORS↗

Effect of enhanced Renilla luciferase and fluorescent protein variants on the Foerster distance of Bioluminescence resonance energy transfer (BRET)

Highlights: Black-Right-Pointing-Pointer First experimental determination of Foerster distance (R{sub 0}) for enhanced BRET systems. Black-Right-Pointing-Pointer Effect of brighter BRET components RLuc2, RLuc8 and Venus was assessed. Black-Right-Pointing-Pointer Using brighter BRET components substantially increased (25%) R{sub 0} of the BRET{sup 1} system. Black-Right-Pointing-Pointer Using brighter BRET components marginally increased (2-9%) R{sub 0} of the BRET{sup 2} system. Black-Right-Pointing-Pointer Brighter BRET components improve the different weaknesses of BRET{sup 1} and BRET{sup 2} systems. -- Abstract: Bioluminescence resonance energy transfer (BRET) is an important tool for monitoring macromolecular interactions and is useful as a transduction technique for biosensor development. Foerster distance (R{sub 0}), the intermolecular separation characterized by 50% of the maximum possible energy transfer, is a critical BRET parameter. R{sub 0} provides a means of linking measured changes in BRET ratio to a physical dimension scale and allows estimation of the range of distances that can be measured by any donor-acceptor pair. The sensitivity of BRET assays has recently been improved by introduction of new BRET components, RLuc2, RLuc8 and Venus with improved quantum yields, stability and brightness. We determined R{sub 0} for BRET{sup 1} systems incorporating novel RLuc variants RLuc2 or RLuc8, in combination with Venus, as 5.68 or 5.55 nm respectively. These values were approximately 25% higher than the R{sub 0} of the original BRET{sup 1} system. R{sub 0} for BRET{sup 2} systems combining green fluorescent proteins (GFP{sup 2}) with RLuc2 or RLuc8 variants was 7.67 or 8.15 nm, i.e. only 2-9% greater than the original BRET{sup 2} system despite being {approx}30-fold brighter.

60 APPLIED LIFE SCIENCES↗

A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Natural time analysis of critical phenomena: The case of pre-fracture electromagnetic emissions

Criticality of complex systems reveals itself in various ways. One way to monitor a system at critical state is to analyze its observable manifestations using the recently introduced method of natural time. Pre-fracture electromagnetic (EM) emissions, in agreement to laboratory experiments, have been consistently detected in the MHz band prior to significant earthquakes. It has been proposed that these emissions stem from the fracture of the heterogeneous materials surrounding the strong entities (asperities) distributed along the fault, preventing the relative slipping. It has also been proposed that the fracture of heterogeneous material could be described in analogy to the critical phase transitions in statistical physics. In this work, the natural time analysis is for the first time applied to the pre-fracture MHz EM signals revealing their critical nature. Seismicity and pre-fracture EM emissions should be two sides of the same coin concerning the earthquake generation process. Therefore, we also examine the corresponding foreshock seismic activity, as another manifestation of the same complex system at critical state. We conclude that the foreshock seismicity data present criticality features as well.

58 GEOSCIENCES↗

Photonic methods and technologies for monitoring the ocean and atmosphere

In this paper, we review photonic methods and technologies that are promising for monitoring the ocean and atmosphere and have been implemented mainly in recent years at the Institute of Automation and Control Processes, Far Eastern Branch, Russian Academy of Sciences. We present results of lidar studies that have made it possible to understand key features of ocean – atmosphere interaction processes under continent – ocean transition conditions, which determine specific features of the atmospheric aerosol distribution, small gaseous components of the atmosphere and its optical characteristics. We consider methods and tools for combined optical and laser fluorescence monitoring of the ocean surface. Particular attention is paid to results of research on remote methods and tools for real-time laser-induced and laser fluorescence environmental monitoring of the ocean, including specialised fibre-optic probes and mobile underwater robotic systems. We present results of the development and investigation of highly sensitive, noise-proof fibre-optic hydro- and seismic/acoustic sensors for remote monitoring of the ocean and robotic systems for underwater laser protection of marine vessels, hydraulic structures and oceanographic instruments against the negative impact of biofouling. (invited paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of oxygenation in the surface layers of biological tissues based on diffuse optical spectroscopy with automated calibration of measurements

To assess the oxygen saturation (oxygenation) in the surface layers of biological tissues (at a depth of 4 mm), a compact system based on diffuse optical spectroscopy (DOS) with reflective measurement geometry in the wavelength range of 520 – 590 nm is proposed. The experimental DOS device is based on a broadband LED source of probe radiation and a spectrometer using a fibre-optic radiation delivery system. To calculate the oxygenation, an original method is proposed based on measuring the intensity of scattered light at four different locations of the source and receiver on the surface of the object under study (four-measurement method). The developed method allows for the device hardware parameters (optical contact with the tissue, transient characteristics of the radiation delivery system) and does not require any additional calibration measurements. The results of testing the DOS system using the four-measurement method for monitoring the oxygen saturation of tissues during the artificial occlusion of the blood vessels agree with the published data of other research teams. (paper)

60 APPLIED LIFE SCIENCES↗

Compression as a Tool to Detect Bose Glass in a Cold Atomic Gas

We suggest that measuring the variation of the radius of an atomic cloud when the harmonic trap confinement is varied makes it possible to monitor the disappearance of the insulating Mott phase of an ultracold atomic gas trapped in a disordered optical lattice. This paves the way for an unambiguous identification of a Bose glass phase in the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards real time diagnostics of Hybrid Welding Laser/GMAW

Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

42 ENGINEERING↗