Dynamic RASE: Semi-Empirical Simulation of In-Motion Sources
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
It is unlikely that we will ever have a deterministic predictive framework for the study of flows in urban scale scenarios purely based on computational fluid dynamics. This is due to the inherent difficulty in modeling and validating all relevant physical sub-processes and acquiring all the necessary and relevant boundary condition information. On the other hand, this case is representative of very fundamental ones for which whole-domain scalable laboratory (or field) studies are impossible or very difficult, but for which it is also crucial to develop predictability. In this paper, we discuss a framework for detailed dispersal predictions in urban and regional settings based on effective linkage of strong motion codes - capable of simulating detailed energetic and contaminant sources, and large-eddy simulation - capable of emulating contaminant transport due to wind and turbulence fields in built-up areas. Challenging technical aspects of the simulation approach are outlined and recent progress is reviewed in th is context.
The effect of an electric field E{sub ||} parallel to the magnetic field B on particle acceleration in shock waves is studied. With test particle calculations, for which the electromagnetic fields of shock waves are obtained from one-dimensional, fully kinetic, electromagnetic, particle simulations, the motions of relativistic ions, electrons, and positrons are analyzed. In these simulations, the shock speed v{sub sh} is taken to be close to c cos {theta}, where {theta} is the angle between the external magnetic field and wave normal, and thus strong particle acceleration takes place. Test particle motions calculated in two different methods are compared: In the first method the total electric field E is used in the equation of motion, while in the second method E{sub ||} is omitted. The comparison confirms that in the acceleration of relativistic ions E{sub ||} is unimportant for high-energy particles. For the acceleration of electrons and positrons, however, E{sub ||} is essential.
Purpose: To quantify respiratory-induced motion of liver segments using the positions of implanted fiducials during robotic radiosurgery. This study also compared fiducial motion derived from four-dimensional computed tomography (4D-CT) maximum intensity projections (MIP) with motion derived from imaging during treatment. Methods: Forty-two consecutive liver patients treated with liver ablative radiotherapy were accrued to an ethics approved retrospective study. The liver segment in which each fiducial resided was identified. Fiducial positions throughout each treatment fraction were determined using orthogonal kilovoltage images. Any data due to patient repositioning or motion was removed. Mean fiducial positions were calculated. Fiducial positions beyond two standard deviations of the mean were discarded and remaining positions were fit to a line segment using least squares minimization (LSM). For eight patients, fiducial motion was derived from 4D-CT MIPs by calculating the CT number weighted mean position of the fiducial on each slice and fitting a line segment to these points using LSM. Treatment derived fiducial trajectories were corrected for patient rotation and compared to MIP derived trajectories. Results: The mean total magnitude of fiducial motion across all liver segments in left-right, anteroposterior, and superoinferior (SI) directions were 3.0 ± 0.2 mm, 9.3 ± 0.4 mm, and 20.5 ± 0.5 mm, respectively. Differences in per-segment mean fiducial motion were found with SI motion ranging from 12.6 ± 0.8 mm to 22.6 ± 0.9 mm for segments 3 and 8, respectively. Large, varied differences between treatment and MIP derived motion at simulation were found with the mean difference for SI motion being 2.6 mm (10.8 mm standard deviation). Conclusion: The magnitude of liver fiducial motion was found to differ by liver segment. MIP derived liver fiducial motion differed from motion observed during treatment, implying that 4D-CTs may not accurately capture the range of liver motion across fractions and during treatment. Author V. Nair was funded by the Cushing estate for a SABR clinical research fellowship.
Laplace is a electric field driven flow simulation program for detailed device design support. Transport processes include electrokinesis, dielectrophoresis, and diffusion. Laplace solves for the electric field in a microfluidic system and the liquid and particle flow that is produced by the electric field for the primary purpose of microfluidic design development and simulation. Laplace allows you to visualize the flow by tracking tracer particles, viewing flow streamlines, etc. Laplace can make movies of simulated particle motion to allow you to test and share the behavior of microfuidic designs. The electric field is calculated using an iterative linear solver and particle motion is solved by finite difference, finite-displacement simulation of particle trajectories. Laplace uses a bitmapped picture or drawing of a microsystem to infer the geometry. The channel depth is everywhere proportional to the magnitude of the blue channel of the image: 0 (black) = zero depth, or no channel, 256 (saturated blue) = deepest channel, and intermediate values correspond to intermediate depths. Laplace automatically applies various boundary conditions (applied voltage or current) to ports, where channels cross the edge of the image.
The dynamics of cylindrically trapped electron plasma has been investigated using a newly developed 2D Electrostatic PIC code that uses unapproximated, mass-included equations of motion for simulation. Exhaustive simulations, covering the entire range of Brillouin ratio, were performed for uniformly filled circular profiles in rigid rotor equilibrium. The same profiles were then loaded away from equilibrium with an initial value of rigid rotation frequency different from that required for radial force balance. Both these sets of simulations were performed for an initial zero-temperature or cold load of the plasma with no spread in either angular velocity or radial velocity. The evolution of the off-equilibrium initial conditions to a steady state involve radial breathing of the profile that scales in amplitude and algebraic growth with Brillouin fraction. For higher Brillouin fractions, the growth of the breathing mode is followed by complex dynamics of spontaneous hollow density structures, excitation of poloidal modes, leading to a monotonically falling density profile.
This paper presents a comparison of parallel strong scaling performance of classical and aggregation algebraic multigrid (AMG) preconditioners in the context of wind turbine simulations. Fluid motion is governed by the incompressible Navier--Stokes equations, discretized in space with control-volume finite elements and in time with an inexact projection scheme using an implicit integrator. A discontinuous-Galerkin sliding-mesh algorithm captures rotor motion. The momentum equations are solved with iterative Krylov methods, preconditioned by symmetric Gauss--Seidel (SGS) in Trilinos and $\ell_1$ SGS in hypre. The mass-continuity equation is solved with GMRES preconditioned by AMG and can account for the majority of simulation time. Reducing this continuity solve time is crucial. Wind turbine simulations present two unique challenges for AMG preconditioned solvers: the computational meshes include strongly anisotropic elements, and mesh motion requires matrix reinitialization and computation of preconditioners at each time step. Detailed timing profiles are presented and analyzed, and best practices are discussed for both classical and aggregation-based AMG. Results are presented for simulations of two different wind turbines with up to 6 billion grid points on two different computer architectures. For moving mesh problems that require linear-system reinitialization, the well-established strategy of amortizing preconditioner setup costs over a large number of time steps to reduce the solve time is no longer valid. Instead, results show that faster time to solution is achieved by reducing preconditioner setup costs at the expense of linear-system solve costs. Standard smoothed aggregation with Chebyshev relaxation was found to perform poorly when compared with classical AMG in terms of solve time and robustness. However, plain aggregation was comparable to classical AMG.
Purpose: In this study, we investigate a technique of matching internal target volumes (ITVs) in four-dimensional (4D) simulation computed tomography (CT) to the composite target volume in free-breathing on-board cone-beam (CB) CT. The technique is illustrated by using both phantom and patient cases. Methods and Materials: A dynamic phantom with a target ball simulating respiratory motion with various amplitude and cycle times was used to verify localization accuracy. The dynamic phantom was scanned using simulation CT with a phase-based retrospective sorting technique. The ITV was then determined based on 10 sets of sorted images. The size and epicenter of the ITV identified from 4D simulation CT images and the composite target volume identified from on-board CBCT images were compared to assess localization accuracy. Similarly, for two clinical cases of patients with lung cancer, ITVs defined from 4D simulation CT images and CBCT images were compared. Results: For the phantom, localization accuracy between the ITV in 4D simulation CT and the composite target volume in CBCT was within 1 mm, and ITV was within 8.7%. For patient cases, ITVs on simulation CT and CBCT were within 8.0%. Conclusion: This study shows that CBCT is a useful tool to localize ITV for targets affected by respiratory motion. Verification of the ITV from 4D simulation CT using on-board free-breathing CBCT is feasible for the target localization of lung tumors.
Unique umbilical designs for wave energy converters (WECs), including the ability to handle significantly larger motions and loads over long deployments, are often required when conventional marine umbilical designs for offshore oil and gas and offshore wind may not meet the design and cost needs of wave energy technologies. This study details a fatigue analysis of a dynamic power umbilical attached to a two-body floating point absorber WEC system, using the sea states provided for the PacWave testing facilities. The 6 degrees of freedom motion time history for the WEC was simulated, and the motions of the attachment point for the umbilical on the WEC and respective sea states were used to analyze the dynamic motions and fatigue of the connected power umbilical to predict the fatigue life. The results show that the fatigue damage observed is more significant in shallow water, and extensive fatigue damage may occur because of the larger curvature response of the umbilical. The umbilical configurations departing at 90 deg off incoming waves were found to have the highest fatigue life attributed to less extension or compression of the umbilical. However, additional bend stiffener/limiter features may need to be incorporated into the buoyancy section and touchdown regions to minimize curvature-induced fatigue.
In this study we simulate and analyze strong ground motion waveform data recorded in the Humboldt Bay and Eureka areas during the M6.5 Ferndale earthquake of January 2010. The scope of the presented work was two-fold. First, we investigated the main aspects of seismic wave generation and propagation, including kinematic rupture process and 3D wave propagation scattering. Our goal is to analyze their potential effects on seismic motion recorded at free field stations across Humboldt Bay and Eureka, California, and test the performance of a standard broadband strong ground motion simulation technique. Second, we evaluated the implication of the non-linear response of shallow sediments on ground motion recorded at the Humboldt Bay geotechnical array. Using synthetic and recorded data we compared the performance of numerical and empirical techniques in simulating local non-linear site response. Our study provides insight into the composition of the wave field during the earthquake and an improved understanding of how the strong ground motion is affected by the 3D structure and non-linear response of shallow sedimentary layers in the Humboldt Bay.
Purpose: Intensity modulated proton therapy (IMPT) can improve dose conformality and better spare normal tissue over passive scattering techniques, but range uncertainties complicate its use, particularly for moving targets. We report our early experience with IMPT for thoracic malignancies in terms of motion analysis and management, plan optimization and robustness, and quality assurance. Methods and Materials: Thirty-four consecutive patients with lung/mediastinal cancers received IMPT to a median 66 Gy(relative biological equivalence [RBE]). All patients were able to undergo definitive radiation therapy. IMPT was used when the treating physician judged that IMPT conferred a dosimetric advantage; all patients had minimal tumor motion (<5 mm) and underwent individualized tumor-motion dose-uncertainty analysis and 4-dimensional (4D) computed tomographic (CT)-based treatment simulation and motion analysis. Plan robustness was optimized by using a worst-case scenario method. All patients had 4D CT repeated simulation during treatment. Results: IMPT produced lower mean lung dose (MLD), lung V{sub 5} and V{sub 20}, heart V{sub 40}, and esophageal V{sub 60} than did IMRT (P<.05) and lower MLD, lung V{sub 20}, and esophageal V{sub 60} than did passive scattering proton therapy (PSPT) (P<.05). D{sub 5} to the gross tumor volume and clinical target volume was higher with IMPT than with intensity modulated radiation therapy or PSPT (P<.05). All cases were analyzed for beam-angle-specific motion, water-equivalent thickness, and robustness. Beam angles were chosen to minimize the effect of respiratory motion and avoid previously treated regions, and the maximum deviation from the nominal dose-volume histogram values was kept at <5% for the target dose and met the normal tissue constraints under a worst-case scenario. Patient-specific quality assurance measurements showed that a median 99% (range, 95% to 100%) of the pixels met the 3% dose/3 mm distance criteria for the γ index. Adaptive replanning was used for 9 patients (26.5%). Conclusions: IMPT using 4D CT-based planning, motion management, and optimization was implemented successfully and met our quality assurance parameters for treating challenging thoracic cancers.
Purpose: To evaluate the geometric accuracy of beam targeting in external surrogate-based gated volumetric modulated arc therapy (VMAT) using kilovoltage (kV) x-ray images acquired during dose delivery. Methods: Gated VMAT treatments were delivered using a Varian TrueBeam STx Linac for both physical phantoms and patients. Multiple gold fiducial markers were implanted near the target. The reference position was created for each implanted marker, representing its correct position at the gating threshold. The gating signal was generated from the RPM system. During the treatment, kV images were acquired immediately before MV beam-on at every breathing cycle, using the on-board imaging system. All implanted markers were detected and their 3D positions were estimated using in-house developed software. The positioning error of a marker is defined as the distance of the marker from its reference position for each frame of the images. The overall error of the system is defined as the average over all markers. For the phantom study, both sinusoidal motion (1D and 3D) and real human respiratory motion was simulated for the target and surrogate. In the baseline case, the two motions were synchronized for the first treatment fraction. To assess the effects of surrogate-target correlation on the geometric accuracy, a phase shift of 5% and 10% between the two motions was introduced. For the patient study, intrafraction kV images of five stereotactic body radiotherapy (SBRT) patients were acquired for one or two fractions. Results: For the phantom study, a high geometric accuracy was achieved in the baseline case (average error: 0.8 mm in the superior-inferior or SI direction). However, the treatment delivery is prone to geometric errors if changes in the target-surrogate relation occur during the treatment: the average error was increased to 2.3 and 4.7 mm for the phase shift of 5% and 10%, respectively. Results obtained with real human respiratory curves show a similar trend. For a target with 3D motion, the technique is able to detect geometric errors in the left-right (LR) and anterior-posterior (AP) directions. For the patient study, the average intrafraction positioning errors are 0.8, 0.9, and 1.4 mm and 95th percentile errors are 1.7, 2.1, and 2.7 mm in the LR, AP, and SI directions, respectively. Conclusions: The correlation between external surrogate and internal target motion is crucial to ensure the geometric accuracy of surrogate-based gating. Real-time guidance based on kV x-ray images overcomes the potential issues in surrogate-based gating and can achieve accurate beam targeting in gated VMAT.
Significance A major challenge of protein crystallography is to accurately describe protein structure variations. Whereas Bragg peaks only yield a picture in which the variations are superimposed, diffuse X-ray scattering (diffraction between the peaks) reports on the way different atoms move together and can be used to increase the accuracy of models. We have performed a molecular-dynamics (MD) simulation of crystalline staphylococcal nuclease, yielding a rich picture of functionally important motions. This simulation is 100-fold longer than previous studies and yields reproducible calculations of diffuse intensity, overcoming a major challenge in the field. Experimental data support the MD models and indicate that diffuse scattering can be used both to validate and to improve MD simulations.
We have investigated a coupled motion of two vortex cores in ferromagnetic/nonmagnetic/ferromagnetic trilayer cynliders by means of micromagnetic simulation. Dynamic motion of two vortex with parallel and antiparallel relative chiralities of curling spins around the vortex cores have been examined after excitation by 1-ns pulsed external field. With systematic variation in non-magnetic spacer layer thickness from 0 to 20 nm, the coupling between two cores becomes significant as the spacer becomes thinner. Significant coupling leads to a nonlinear chaotic coupled motion of two vortex cores for the parallel chiralities and a faster coupled gyrotropic oscillation for the antiparallel chiralities.
Here, the devastating 24 August 2016 M w 6.2 earthquake that struck Amatrice, Italy, marked the beginning of a prolonged seismic sequence dominated by three subsequent M w ≥6.0 events in the central Apennines region. The earthquake destroyed Amatrice’s historic center, claiming the lives of 299 individuals and causing widespread damage in the neighboring villages. The severity of the ground shaking, with a recorded maximum acceleration of 850 cm/s 2 on the east–west component at the Amatrice station, was far greater than the predicted acceleration based on the Italian ground-motion model (GMM). As pointed out by several investigations, the observed ground-motion amplitude and its spatial variability during the earthquake can be linked to specific rupture characteristics, including slip distribution and rupture directivity effects revealed by the observed data (Tinti et al., 2016; Pischiutta et al., 2021). In this study, we conducted physics-based 3D numerical simulations of ground motion for the Amatrice earthquake for frequencies up to 3 Hz. We employed a series of kinematic rupture models and a well-constrained local 3D velocity model incorporating surface topography. The kinematic rupture realizations were generated using multiscale hybrid and fully stochastic models, following the technique proposed by Graves and Pitarka (2016). We focused on assessing the sensitivity of near-fault ground-motion amplitudes to earthquake rupture characteristics, in particular, the spatial slip pattern. To evaluate the quality of our simulations, we employed goodness-of-fit measurements performed in comparisons of simulated and recorded ground motions. The simulated ground motions compare well with the recorded data and predictions from GMMs for Italy, ITA18 (Lanzano et al., 2019). However, we found that the simulated interevent ground-motion variability (randomness in the source process) of peak ground velocity, σ (PGV) is higher than the constant σ (PGV) predicted by conventional GMMs. Our simulations using several rupture scenarios demonstrate that the near-fault ground-motion amplification pattern is directly related to the slip distribution pattern.
Purpose: Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D{sub vol}) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). Methods: 4D{sub vol} CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological ''tumor'' objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Results: Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D{sub vol} CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D{sub vol} CT. Under irregular breathing, the 4D{sub vol} CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D{sub vol} CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. Conclusions: 4D{sub vol} CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach.
Modeling of Fourier amplitude spectra (FAS) of seismic motions has gained much attention in engineering seismology. In the past few years, several ground motion prediction equations (GMPEs) and inter-frequency correlation structure of FAS have been established. Due to many preferable characteristics of FAS, probabilistic seismic hazard/risk analysis is rapidly changing from ergodic, spectrum acceleration Sa(T 0 )-based approach to non-ergodic, site-specific, FAS-based approach. This paper presents time domain intrusive framework for probabilistic seismic risk analysis using GMPE of FAS. Herein, methodology for time domain stochastic ground motion modeling based on GMPEs of FAS is presented in some detail. The simulated uncertain motions are modeled as a random process and represented by polynomial chaos Karhunen-Loève expansion. The random process excitations are further propagated into the uncertain structural system using Galerkin stochastic finite element method (SFEM). Probabilistic evolution of structural response is solved, and such solution is used to develop seismic risk for any damage state. The presented framework is illustrated through seismic risk analysis of a four-story building subjected to possible earthquakes from two strike slip faults. The influences of the epistemic uncertainties in source stress drop Δσ and site attenuation κ0 on seismic risk are investigated. The need for non-ergodic seismic risk analysis with source-specific and site specific characterizations is emphasized.
The effect of the plasma electrode bias voltage in the negative ion sources is modeled and investigated with one-dimensional plasma simulation. A particle-in-cell (PIC) method is applied to simulate the motion of charged particles in their self-consistent electric field. In the simulation, the electron current density is fixed to produce the bias voltage. The tendency of current-voltage characteristics obtained in the simulation show agreement with the one obtained from a simple probe theory. In addition, the H{sup -} ion density peak appears at the bias voltage close to the plasma potential as observed in the experiment. The physical mechanism of this peak H{sup -} ion density is discussed.