Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developments of Highly Multiplexed, Multi-chroic Pixels for Balloon-Borne Platforms

We present our work to develop and characterize low thermal conductance bolometers that are part of sinuous antenna multi-chroic pixels (SAMP). We use longer, thinner and meandered bolometer legs to achieve 9 pW/K thermal conductance bolometers. We also discuss the development of inductor–capacitor chips operated at 4 K to extend the multiplexing factor of the frequency domain multiplexing to 105, an increase of 60% compared to the factor currently demonstrated for this readout system. This technology development is motivated by EBEX-IDS, a balloon-borne polarimeter designed to characterize the polarization of foregrounds and to detect the primordial gravity waves through their B-mode signature on the polarization of the cosmic microwave background. EBEX-IDS will operate 20,562 transition edge sensor bolometers spread over 7 frequency bands between 150 and 360 GHz. Balloon and satellite platforms enable observations at frequencies inaccessible from the ground and with higher instantaneous sensitivity. This development improves the readiness of the SAMP and frequency domain readout technologies for future satellite applications.

42 ENGINEERING↗

Josephson Effects in Frequency-Domain Multiplexed TES Microcalorimeters and Bolometers

Frequency-division multiplexing is the baseline read-out system for large arrays of superconducting transition-edge sensors (TES’s) under development for the X-ray and infrared instruments like X-IFU (Athena) and SAFARI, respectively. In this multiplexing scheme, the sensors are ac-biased at different frequencies from 1 to 5 MHz and operate as amplitude modulators. Weak superconductivity is responsible for the complex TES resistive transition, experimentally explored in great detail so far, both with dc- and ac-biased read-out schemes. In this paper, we will review the current status of our understanding of the physics of the TES’s and their interaction with the ac bias circuit. In particular, we will compare the behaviour of the TES nonlinear impedance, across the superconducting transition, for several detector families, namely: high-normal-resistance TiAu TES bolometers, low-normal-resistance MoAu TES microcalorimeters and high-normal-resistance TiAu TES microcalorimeters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

100 Gbps multiplexed inter-satellite optical wireless communication system

In this paper, the performance analysis of the inter-satellite optical wireless communication system (IsOWC) is carried out in presence of optical space channel. Here the proposed model is a 16×100 Gbps dense multiplexed IsOWC. The dual polarized quadrature phase shift keying (DP-QPSK) modulation is used for improving the optical signal to noise ratio tolerance of the system. Further, the spectral efficiency and the receiver sensitivity is improved by incorporating the coherent orthogonal frequency division multiplexing (CO-OFDM) technique in the proposed IsOWC system. The performance of the system is evaluated by bit error rate (BER), error vector magnitude percentage, received signal power, constellation diagram. A comparative study has been carried out between different modulation techniques such as quadrature phase shift keying and DP-QPSK used in IsOWC system. It is observed that, an inter-satellite distance of 15,600 km is obtained with the proposed model at 100 Gbps for a targeted forward error correction log of BER value of − 2.42 or BER of 3.8×10{sup −3}. The maximum possible data rate for different inter and intra orbit satellite has been calculated. Also, the maximum possible transceiver distance has been calculated for different data rates. The integration of two advanced technologies such as DP-QPSK modulation with CO-OFDM technique in the proposed model may impel the market demands for high bandwidth intensive and high data rate applications.

42 ENGINEERING↗

Quantitative multiplex quantum dot in-situ hybridisation based gene expression profiling in tissue microarrays identifies prognostic genes in acute myeloid leukaemia

Highlights: Black-Right-Pointing-Pointer Development of a quantitative high throughput in situ expression profiling method. Black-Right-Pointing-Pointer Application to a tissue microarray of 242 AML bone marrow samples. Black-Right-Pointing-Pointer Identification of HOXA4, HOXA9, Meis1 and DNMT3A as prognostic markers in AML. -- Abstract: Measurement and validation of microarray gene signatures in routine clinical samples is problematic and a rate limiting step in translational research. In order to facilitate measurement of microarray identified gene signatures in routine clinical tissue a novel method combining quantum dot based oligonucleotide in situ hybridisation (QD-ISH) and post-hybridisation spectral image analysis was used for multiplex in-situ transcript detection in archival bone marrow trephine samples from patients with acute myeloid leukaemia (AML). Tissue-microarrays were prepared into which white cell pellets were spiked as a standard. Tissue microarrays were made using routinely processed bone marrow trephines from 242 patients with AML. QD-ISH was performed for six candidate prognostic genes using triplex QD-ISH for DNMT1, DNMT3A, DNMT3B, and for HOXA4, HOXA9, Meis1. Scrambled oligonucleotides were used to correct for background staining followed by normalisation of expression against the expression values for the white cell pellet standard. Survival analysis demonstrated that low expression of HOXA4 was associated with poorer overall survival (p = 0.009), whilst high expression of HOXA9 (p < 0.0001), Meis1 (p = 0.005) and DNMT3A (p = 0.04) were associated with early treatment failure. These results demonstrate application of a standardised, quantitative multiplex QD-ISH method for identification of prognostic markers in formalin-fixed paraffin-embedded clinical samples, facilitating measurement of gene expression signatures in routine clinical samples.

60 APPLIED LIFE SCIENCES↗

Analysis of sensitivity and rapid hybridization of a multiplexed Microbial Detection Microarray

Microarrays have proven to be useful in rapid detection of many viruses and bacteria. Pathogen detection microarrays have been used to diagnose viral and bacterial infections in clinical samples and to evaluate the safety of biological drug materials. A multiplexed version of the Lawrence Livermore Microbial Detection Array (LLMDA) was developed and evaluated with minimum detectable concentrations for pure unamplified DNA viruses, along with mixtures of viral and bacterial DNA subjected to different whole genome amplification protocols. In addition the performance of the array was tested when hybridization time was reduced from 17 h to 1 h. The LLMDA was able to detect unamplified vaccinia virus DNA at a concentration of 14 fM, or 100,000 genome copies in 12 μL of sample. With amplification, positive identification was made with only 100 genome copies of input material. When tested against human stool samples from patients with acute gastroenteritis, the microarray detected common gastroenteritis viral and bacterial infections such as rotavirus and E. coli. Accurate detection was found but with a 4-fold drop in sensitivity for a 1 h compared to a 17 h hybridization. The array detected 2 ng (equivalent concentration of 15.6 fM) of labeled DNA from a virus with 1 h hybridization without any amplification, and was able to identify the components of a mixture of viruses and bacteria at species and in some cases strain level resolution. Sensitivity improved by three orders of magnitude with random whole genome amplification prior to hybridization; for instance, the array detected a DNA virus with only 20 fg or 100 genome copies as input. This multiplexed microarray is an efficient tool to analyze clinical and environmental samples for the presence of multiple viral and bacterial pathogens rapidly.

59 BASIC BIOLOGICAL SCIENCES↗

Algorithm for extracting multiple object waves without Fourier transform from a single image recorded by spatial frequency-division multiplexing and its application to digital holography

Here, we propose a novel algorithm that does not require any Fourier transform to extract multiple object waves in a single image recorded with spatial frequency-division multiplexing. Smoothing is utilized to extract the desired object-wave information from a spatially multiplexed image. Numerical and experimental results show its validity and applicability for image and Fresnel digital holography. Our investigations clarify the speeding up of both the object-wave extractions and multiple object–image reconstructions quantitatively.

42 ENGINEERING↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Additively manufactured multiplexed inertial coalescence filters

Multiphase flows often pose a significant challenge to the efficient and reliable design of thermofluidic systems. This paper describes multiplexed inertial coalescence filters composed of parallel helical pathways, designed to capture fine droplets (<40 µm) through inertial separation while maintaining a low pressure drop (<400 Pa). Filtration efficiencies for 7 µm and 30 µm droplets were characterized for varying flow conditions, with complete capture observed above a threshold flow rate. Models for filtration efficiency and pressure drop were developed and validated against experimental results to allow system design and optimization, enabled by the tunable additive manufacturing approach used to fabricate the filters. Filter quality factor was computed for varying droplet sizes, showcasing exceptional quality factor when compared to state-of-the-art filters documented in the literature. In conclusion, this multiplexed inertial coalescence filtration approach could find use in dehumidification systems, fog harvesting, chemical reactors, and microgravity droplet capture.

3D Printing↗

Multiplexable intrinsic Fabry-Pérot interferometers inscribed by femtosecond laser for vibration measurement in high temperature environments

This article reports fabrication technique and demodulation algorithm developments to use multiplexable intrinsic Fabry-Pérot interferometer (IFPI) fiber sensor array for distributed vibration measurements at high temperatures. Using femtosecond laser direct writing scheme, IFPI array were fabricated through laser-induced Type II scattering points in single mode fiber cores. Reflection spectra of IFPI array were demodulated in real-time using modified Bunemen frequency analysis. The demodulation algorithm, which was implemented using a photodetector-array spectrometer, achieves 64-nε dynamic strain resolution at 1-kHz spectral acquisition rate and 2-kHz maximum vibration bandwidth. Performance and stabilities of IFPI sensor array were characterized from room temperatures to 800 °C. The static strain resolution was 0.6 με and the minimum detectable dynamic strain amplitude was 23 nε/√Hz at 800 °C. The multiplex performance was also tested by measuring dynamic strain in time domain through six IFPI sensor array fabricated in one fiber. This paper presents an integrated and low-cost sensing solution to perform distributed vibration measurements in harsh environments.

42 ENGINEERING↗

Evaluating Linear Ion Trap for MS3-Based Multiplexed Single-Cell Proteomics

There is a growing demand to develop high-throughput and high-sensitivity mass spectrometry methods for single-cell proteomics. The commonly used isobaric labeling-based multiplexed single-cell proteomics approach suffers from distorted protein quantification due to co-isolated interfering ions during MS/MS fragmentation, also known as ratio compression. We reasoned that the use of MS3-based quantification could mitigate ratio compression and provide better quantification. However, previous studies indicated reduced proteome coverages in the MS3 method, likely due to long duty cycle time and ion losses during multilevel ion selection and fragmentation. Here, in this paper, we described an improved MS acquisition method for MS3-based single-cell proteomics by employing a linear ion trap to measure reporter ions. We demonstrated that linear ion trap can increase the proteome coverages for single-cell-level peptides with even higher gain obtained via the MS3 method. The optimized real-time search MS3 method was further applied to study the immune activation of single macrophages. Among a total of 126 single cells studied, over 1200 and 1000 proteins were quantifiable when at least 50 and 75% nonmissing data were required, respectively. Our evaluation also revealed several limitations of the low-resolution ion trap detector for multiplexed single-cell proteomics and suggested experimental solutions to minimize their impacts on single-cell analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplex Detection of Multiple-Quantum/Single-Quantum NMR Correlation Spectra

High-ordered multiple-quantum coherences have been used to gauge the size of coupled networks of nuclear spins but are seldom used in modern high-resolution solid-state NMR spectroscopy due to the low resolution of earlier techniques. Herein, we extend this work to the third dimension by designing an MQ spin counting experiment with full chemical resolution of the nuclei involved in the coherences. The technique uses multiplex processing to simultaneously acquire MQ/1Q correlation 2D spectra, with all even-ordered values of M, in the same amount of time it would take to acquire the 2Q/1Q spectrum alone. Further, we apply this multiplexed MQ/1Q correlation method to probe site clustering on functionalized silica surfaces and find the first evidence of clusters involving three or more functionalities. When applied to a supported zirconium metallocene, the observation of a 6Q coherence between six cyclopentadienyl proton nuclei confirms the colocation of two cyclopentadienyl ligands on a single metal center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extending the Near-Infrared Emission Range of Indium Phosphide Quantum Dots for Multiplexed In Vivo Imaging

This report of the reddest emitting indium phosphide quantum dots (InP QDs) to date demonstrates tunable, near-infrared (NIR) photoluminescence (PL) as well as PL multiplexing in the first optical tissue window while avoiding toxic constituents. This synthesis overcomes the InP “growth bottleneck” and extends the emission peak of InP QDs deeper into the first optical tissue window using an inverted QD heterostructure, specifically ZnSe/InP/ZnS core/shell/shell nanoparticles. The QDs exhibit InP shell thickness-dependent tunable emission with peaks ranging from 515–845 nm. The high absorptivity of InP yields effective photoexcitation of the QDs with UV, visible, and NIR wavelengths. These nanoparticles extend the range of tunable direct-bandgap emission from InP-based nanostructures, effectively overcoming a synthetic barrier that has prevented InPbased QDs from reaching their full potential as NIR imaging agents. Further, multiplexed lymph node imaging in a mouse model demonstrates the potential of the NIR-emitting InP particles for in vivo imaging.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

DNA-Mediated Size-Selective Nanoparticle Assembly for Multiplexed Surface Encoding

Multiplexed surface encoding is achieved by positioning two different sizes of gold nanocubes on gold surfaces with precisely defined locations for each particle via template-confined, DNA-mediated nanoparticle assembly. As a proof-of-concept demonstration, cubes with 86 and 63 nm edge lengths are assembled into arrangements that physically and spectrally encrypt two sets of patterns in the same location. These patterns can be decrypted by mapping the absorption intensity of the substrate at $λ$ = 773 and 687 nm, respectively. This multiplexed encoding platform dramatically increases the sophistication and density of codes that can be written using colloidal nanoparticles, which may enable high-security, high-resolution encoding applications.

36 MATERIALS SCIENCE↗

Dynamic Multiplexed Control and Modeling of Optogenetic Systems Using the High-Throughput Optogenetic Platform, Lustro

The ability to control cellular processes using optogenetics is inducer-limited, with most optogenetic systems responding to blue light. To address this limitation, we leverage an integrated framework combining Lustro, a powerful high-throughput optogenetics platform, and machine learning tools to enable multiplexed control over blue light-sensitive optogenetic systems. Specifically, we identify light induction conditions for sequential activation as well as preferential activation and switching between pairs of light-sensitive split transcription factors in the budding yeast, Saccharomyces cerevisiae. We use the high-throughput data generated from Lustro to build a Bayesian optimization framework that incorporates data-driven learning, uncertainty quantification, and experimental design to enable the prediction of system behavior and the identification of optimal conditions for multiplexed control. This work lays the foundation for designing more advanced synthetic biological circuits incorporating optogenetics, where multiple circuit components can be controlled using designer light induction programs, with broad implications for biotechnology and bioengineering.

59 BASIC BIOLOGICAL SCIENCES↗

Redirecting Metabolic Flux via Combinatorial Multiplex CRISPRi-Mediated Repression for Isopentenol Production in Escherichia coli

CRISPR interference (CRISPRi) via target guide RNA (gRNA) arrays and a deactivated Cas9 (dCas9) protein has been shown to simultaneously repress expression of multiple genomic DNA loci. By knocking down endogenous genes in competing pathways, CRISPRi technology can be utilized to redirect metabolic flux toward target metabolite. In this study, we constructed a CRISPRi-mediated multiplex repression system to silence transcription of several endogenous genes to increase precursor availability in a heterologous isopentenol biosynthesis pathway. To identify genomic knockdown targets in competing pathways, we first designed a single-gRNA library with 15 individual targets, where 3 gRNA cassettes targeting gene asnA, prpE, and gldA increased isopentenol titer by 18-24%. We then combined the 3 single-gRNA cassettes into a two- or three-gRNA array and observed up to 98% enhancement in production by fine-tuning the repression level through titrating dCas9 expression. Our strategy shows that multiplex combinatorial knockdown of competing genes using CRISPRi can increase production of the target metabolite, while the repression level needs to be adjusted to balance the metabolic network and achieve the maximum titer improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.

47 OTHER INSTRUMENTATION↗

Flexible organic integrated electronics for self-powered multiplexed ocular monitoring

Smart contact lens has drawn extensive research interests due to the noninvasive real-time detection of the human body to provide biomedical information for health management. However, it has been difficult to accurately measure the physiological signals in tears, and the use of external power source has also hindered the future applications. Here, we demonstrated an organic electrochemical transistor based multiplexed sensors self-powered by the organic solar cells (OSCs). The integrated device was fabricated via simple process including solution blade-coating and thermal evaporation. OSCs were optimized to provide optimal operation voltage for the sensors that exhibit semilog-linear response to the glucose and calcium ions in tear fluids without any peripheral circuits. The sensing signals can be transmitted to the laptop wirelessly through a near filed communication unit. This integrated self-powered multiplexed sensing device will provide real-time monitoring of the biomarkers in tears, prospected to be installed on the smart contact lens for the early detection and diagnosis of diabetes.

36 MATERIALS SCIENCE↗