Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron shield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Shielding Analyses for SNS Accelerator Power Upgrade

The Proton Power Upgrade (PPU) project [1] at Spallation Neutron Source (SNS) is aiming at increasing the neutron beam intensities at the First Target Station (FTS) and advancing accelerator capability to additionally power a future Second Target Station (STS) [2]. PPU will involve upgrading the SNS accelerator complex to double the currently available proton beam power from 1.4 to 2.8 MW, by increasing the proton beam energy from 1 GeV to 1.3 GeV and by increasing the proton beam current.PPU will enable new science capabilities enhancing the experiment throughput of the 19 existing FTS instruments, which are heavily oversubscribed. STS will include 22 additional neutron scattering instruments. Numerous neutronics analyses are performed to support PPU evaluating the FTS systems for higher beam power and for system upgrades. Part of the PPU scope is an extension of the Ring to Target Beam Transport (RTBT) line, a stub out of the accelerator tunnel for the future Ring to STS Transport (RTST) line[3]. As the RTST tunnel will not be built within the PPU project, the stub will be shielded by a plug, which is planned to be made from regular concrete.In order to provide radiation protection safety, analyses are required to design adequate plug thickness for the stub. The thickness of the stub is driven by the criterion that the area downstream of the plug is “unrestricted access area”, demanding the dose rate downstream the stub be below 0.25 mrem/h at 30 cm from the surface at normal operation and below 20 Rem/hr for accident cases. Additionally, analyses verifying the amount of soil for shielding the accelerator tunnel to the above stated requirements are performed.

Popova, Irina I.↗

Implementation of the D1S Methodology for Shutdown Dose Rate Calculations in the OpenMC Monte Carlo Particle Transport Code

We present an implementation of the direct one-step (D1S) methodology for shutdown dose rate (SDR) calculations in the OpenMC Monte Carlo particle transport code. In addition to being the first fully open-source D1S implementation, it is also the first to require no ad hoc source code or nuclear data library modifications. The code can seamlessly switch between production of prompt and decay photons based on a user input parameter, and the decay data needed for decay photon generation are made available through a depletion chain file, which is already used for OpenMC’s built-in depletion/activation solver. A set of Python functions significantly eases the burden of computing and applying time correction factors needed to properly account for the time dependence of radionuclide activity. To assess the accuracy of the D1S implementation, SDR calculations have been carried out for three problems: a prism of iron irradiated by 14-MeV neutrons, the ITER port plug computational benchmark, and the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For each of these problems, comparisons were made to calculations using the rigorous two-step (R2S) method. The results on the iron prism problem illustrate how the D1S method achieves superior spatial resolution compared to the R2S method without the need for spatial discretization of the activation regions. The D1S and R2S results for the ITER port plug benchmark agree well with previously reported results in the literature. While the D1S results are 10% to 15% lower than the R2S results, this may be due to stochastic uncertainty and/or spatial discretization in the R2S calculations. On the FNG dose rate benchmark problem, the D1S method produces dose rate estimates that are within 4% of the dose rates predicted using a cell-based R2S workflow. The D1S estimates of the SDR are also in reasonable agreement with the experimental measurements and show the same basic trends that have been observed in previous works. A qualitative analysis of the execution time and uncertainty for the R2S and D1S workflows suggests that the D1S method would attain a higher figure of merit.

D1S method↗

An NCrystal extension for thermal neutron scattering in MCNP

A new extension for MCNP has been developed that incorporates the NCrystal thermal scattering package in the form of a Fortran to C++ wrapper, which adds the capability to describe thermal neutron scattering in the NCrystal formalism instead of the ACE tabular format. This can be used to described poly- or single-crystalline materials as well as liquids. In conclusion, the functionality of this extension to MCNP is illustrated using a layered crystal monochromator, leakage of neutrons from a moderating sphere of material, and by simulating criticality benchmarks.

MCNP↗

Alternative Source Verification for the NB5 Beamline

This report details the calculation and comparison of secondary neutron sources for the purpose of performing NB5 velocity selector shielding calculations without relying on the primary HB4 source and the use of a modified MCNP code to run the full model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System, algorithm, and method using short pulse interrogation with neutrons to detect and identify matter

A system, method, and algorithm for detecting and identifying special nuclear material (SNM) (including fissionable material), explosives, or drugs is disclosed. This material detection system relies on active interrogation of material using a short, intense neutron pulse, and characterization of the resulting prompt gamma response in two short time windows, the first concurrent with and the second immediately following the end of the neutron pulse, optionally subject to a total transit delay time of the neutrons from the neutron source to the target and from the target to the gamma detector. A high data rate analysis system implements data stream analysis and statistical correlations of the two short time window gamma responses to rapidly detect or identify SNM, explosives, or drugs. The duration of the neutron pulse is so short that minimal dose results. Various shields help to minimize the background signal falling on the gamma detector to improve sensitivity.

Derzon, Mark S.↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing earth-bound dark matter with nuclear reactors

Strongly-interacting dark matter can be accumulated in large quantities inside the Earth, and for dark matter particles in a few GeV mass range, it can exist in large quantities near the Earth’s surface. We investigate the constraints imposed on such dark matter properties by its upscattering by fast neutrons in nuclear reactors with subsequent scattering in nearby well-shielded dark matter detectors, schemes which are already used for searches of the coherent reactor neutrino scattering. We find that the existing experiments cover new parameter space on the spin-dependent interaction between dark matter and the nucleon. Similar experiments performed with research reactors, and lesser amount of shielding, may provide additional sensitivity to strongly-interacting dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Irradiation performance of nonfertile (Pu-MA-Zr) fast reactor metal fuels

This work was part of a program begun in 2001 to develop advanced nuclear fuels, originally as carriers for plutonium and minor actinides (neptunium, curium, and americium) taken from spent commercial light-water reactors (LWR) so that the plutonium and minor actinides could be ‘burned’ or transmuted in an accelerator or a fast nuclear reactor. A central part of these experiment programs has been the development of advanced fast reactor fuels, because a fast reactor was considered the most efficient vehicle to transmute the actinide waste products, and metallic fuels is a central focus of these tests. An experiment design was developed in which a thermal test reactor, the Advanced Test Reactor (ATR), was used to test small fuel pin prototypes, by creating areas in the core shielded by cadmium filters to produce a largely epithermal and fast neutron spectrum environment in which the pins could be irradiated. The results of non-fertile metallic fuel (no uranium) tests are presented here. Pu-Am-Np-Zr fuels were irradiated to fission densities up to 33 × 10 20 fission/cm 3 and Pu-239 depletions of up to 39%. The depletions were created by roughly 2/3 by fission and 1/3 by transmutation neutron capture. Up to five fuel ‘rodlets’ were irradiated in three sealed capsules stacked axially in the core, and the peak cladding temperatures ranged from 300°C to 500°C, depending on axial location as those near the core centerline are operating hotter and to higher fission densities. Several post-irradiation examinations (precision gamma scanning and fission gas release) were similar to other historical metal fuel experiments in fast reactors. However, optical metallography indicated that two of the rodlets had breached. The exact reasons are unclear. Due to the design of this irradiation experiment a rodlet breach could have increased the temperature in others in the same capsule by contaminating the thermal gap helium with heavier and less conductive fission product gases. Finally, some of those rodlets showed high amounts of fuel/cladding chemical interaction (FCCI).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutronics Evaluation of the Preliminary Design of the Service Cell Door for the Second Target Station

The service cell door needs to provide sufficient shielding to achieve 0.25 mrem/h dose rates in the adjacent room while remote handling operations of waste materials are going on within the service cell for the Second Target Station (STS). This analysis provides a neutronics evaluation of the preliminary design of the service cell door to evaluate the required thickness and the effect of streaming gaps around the door. As radiation source, we use the decay gamma source of the moderator reflector assembly (MRA) of the STS with a decay time of either two days or six months. As the MRA contains a significant amount of beryllium, photonuclear reactions induce a neutron source, which dictates the required door thickness in certain situations. Four scenarios with different MRA positions and decay times have been analyzed. The required thickness differs drastically depending on the chosen scenario and on the material of the door. The streaming through the gaps around the door is relatively small with high dose rates limited to small sections of the geometry.

43 PARTICLE ACCELERATORS↗

Shielding development for the VENUS imaging instrument

VENUS is an imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold, will include enhanced contrast mechanisms, and will offer novel energy-selective imaging techniques that directly connect the structures, properties, and function of complex engineering materials and systems to reveal practical and fundamental answers about their real-world performance. The instrument is to be built at SNS beam line 10 and will face the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beam line and instrument cave shielding. Initial scoping analyses were performed to estimate thickness and composition of shielding materials for the instrument cave and beam line. In light of the upcoming Proton Power Upgrade (PPU) project, these transport analyses were performed for proton beam on target at 1.3 GeV and 2 MW.

Popova, Irina I.↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Target Station Project (STS) Steerable Optic Design & Testing Report

Multiple neutron scattering instrument concepts for the Spallation Neutron Source's Second Target Station (STS) incorporate advanced neutron optic designs which incorporate discrete mirrors rather than continuous neutron guides that were the standard for instruments in the First Target Station. These mirrors can be a few to several meters in length and must be stably supported and aligned as a single optic. In addition, due to the length of the STS instruments and the small size of the STS neutron beams, installation and alignment at the micron level of precision will be required, which is beyond the ability of today's survey & alignment technology. Thus, a means of remotely adjusting these mirrors with single digit micron resolution is needed. A Steerable Optic System was designed to provide the precision and resolution required to support and manipulate these large, heavy optics under beamline shielding. A mockup was developed to demonstrate and validate this system for use in neutron optic applications, and this document describes the design and testing results of that mockup.

43 PARTICLE ACCELERATORS↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic Designs of New First Target Beamline Magnets for the ORNL SNS Upgrade

The Spallation Neutron Source (SNS) at ORNL currently is being upgraded from 1.0 GeV to 1.3 GeV. Several water-cooled magnets should be upgraded to transport 30% of higher beam energy. New chicane, injection/extraction septum, and Lambertson magnets were designed. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field do not disturb the circulating beam. The special field profiles had to be provided in foil areas between magnets. The analysis described here was based on OPERA3D simulations. A special technique was used for analyzing the integrated field harmonics. Initially, the particle track was simulated, and integrated field components were calculated along this track for the reference radius, which were used for the harmonics analysis. In addition, 3D field maps were provided for beam optics simulations. The final beamline analysis confirmed good beam transmission and low losses.

3d field maps↗