Search NASASearch

SEARCH · Search NASA

Results for “nickel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

150 records · Page 9

A high reliability battery management system

Over a period of some 5 years Canadian Astronautics Limited (CAL) has developed a system to autonomously manage, and thus prolong the life of, secondary storage batteries. During the development, the system was aimed at the space vehicle application using nickel cadmium batteries, but is expected to be able to enhance the life and performance of any rechargeable electrochemical couple. The system handles the cells of a battery individually and thus avoids the problems of over, and under, drive that inevitably occur in a battery of cells managed by an averaging system. This individual handling also allow cells to be totally bypassed in the event of failure, thus avoiding the losses associated with low capacity, partial short circuit, and the catastrophe of open circuit. The system has an optional capability of managing redundant batteries simultaneously, adding the advantage of on line reconditioning of one battery, while the other maintains the energy storage capability of the overall system. As developed, the system contains a dedicated, redundant, microprocessor, but the capability exists to have this computing capability time shared, or remote, and operating through a data link. As adjuncts to the basic management system CAL has developed high efficiency, polyphase, power regulators for charge and discharge power conditioning.

Moody, M. H.

International Space Station Lithium-Ion Battery Status

When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35% depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. The first set of six Ni-H2 batteries was replaced by Li-Ion batteries in December 2016; the second set of six was launched in September 2018 and installed in March 2019. The third set of six were launched in September 2019. Three batteries were installed in September 2019, with the remaining three to be installed in January 2020. This paper will include a brief overview of the ISS Li-Ion battery system architecture, start up of the second and third set of 6 batteries and the on-orbit status of all 18 batteries, plus the status of the Li-Ion cell life testing.

Lithium-Ion

Hubble Space Telescope On-orbit NiH2 Battery Performance

This paper summarizes the Hubble Space Telescope (HST) nickel-hydrogen (NiH2) battery performance from launch to the present time. Over the life of HST vehicle configuration, charge system degradation and failures together with thermal design limitations have had a significant effect on the capacity of the HST batteries. Changes made to the charge system configuration in order to protect against power system failures and to maintain battery thermal stability resulted in undercharging of the batteries. This undercharging resulted in decreased usable battery capacity as well as battery cell voltage/capacity divergence. This cell divergence was made evident during on-orbit battery capacity measurements by a relatively shallow slope of the discharge curve following the discharge knee. Early efforts to improve the battery performance have been successful. On-orbit capacity measurement data indicates increases in the usable battery capacity of all six batteries as well as improvements in the battery cell voltage/capacity divergence. Additional measures have been implemented to improve battery performance, however, failures within the HST Power Control Unit (PCU) have prevented verification of battery status. As this PCU fault prevents the execution of on-orbit capacity testing, the HST Project has based the battery capacity on trends, which utilizes previous on-orbit battery capacity test data, for science mission and servicing mission planning. The Servicing Mission 38 (SM-3B) in March 2002 replaced the faulty PCU. Following the servicing mission, on-orbit capacity test resumed. A summary of battery performance is reviewed since launch in this paper.

Rao, Gopalakrishna M.

Microbiological Characterization and Concerns of the International Space Station Internal Active Thermal Control System

Since January 1999, the chemical the International Space Station Thermal Control System (IATCS) and microbial state of (ISS) Internal Active fluid has been monitored by analysis of samples returned to Earth. Key chemical parameters have changed over time, including a drop in pH from the specified 9.5 +/- 0.5 ta = 58.4, an increase in the level of total inorganic carbon (TIC), total organic carbon (TOC) and dissolved nickel (Ni) in the fluid, and a decrease in the phosphate (PO,) level. In addition, silver (AS) ion levels in the fluid decreased rapidly as Ag deposited on internal metallic surfaces of the system. The lack of available Ag ions coupled with changes in the fluid chemistry has resulted in a favorable environment for microbial growth. Counts of heterotrophic bacteria have increased from less than 10 colony-forming units (CFUs)/l00 mL to l0(exp 6) to l0(exp 7) CFUs/100 mL. The increase of the microbial population is of concern because uncontrolled microbiological growth in the IATCS can contribute to deterioration in the performance of critical components within the system and potentially impact human health if opportunistic pathogens become established and escape into the cabin atmosphere. Micro-organisms can potentially degrade the coolant chemistry; attach to surfaces and form biofilms; lead to biofouling of filters, tubing, and pumps; decrease flow rates; reduce heat transfer; initiate and accelerate corrosion; and enhance mineral scale formation. The micro- biological data from the ISS IATCS fluid, and approaches to addressing the concerns, are summarized in this paper.

Monsi C Roman

Behavior of 2-Cell CPV Ni-H2 Battery During Pulse Discharge

A study was carried out to determine the transient voltage behavior of the 2-cell CPV nickel-hydrogen battery with the objective of using the results as a basis for mathematical modeling. The 2-cell CPV battery which is manufactured by Eagle Picher, Inc. for the GOES program yields 18.5 Ah at C/2 rate of discharge at 10 C with a mid-discharge voltage of 2.514 V. The capacity increased with decrease of temperature and a maximum capacity of 22 Ah was obtained at -5 C. The pulse tests consisted of obtaining the voltage profile in the first 20 milliseconds of the one minute pulse discharge at 37 A and pulse discharge was repeated as a function of state-of-charge. The pulse test at 10 C and 20 C provided voltage profiles with the expected decrease in voltage as the pulse was applied. The end of pulse voltage decreased with the state-of-charge. The battery voltage was above 2V at the end of the one-minute pulse at 8 % state-of-charge at 10 C. The voltage profile during the 37 A pulse discharge consists of an initial drop in voltage which was independent of the state of charge. The invariability in the value for the initial drop in voltage with state of charge is a very important observation. The results show that towards the end of discharge the dominant resistance is not ohmic in nature. It could be hypothesized from the nature of the voltage transients that the dominant mechanism towards the end of discharge is proton diffusion. The study also shows that the dominant resistance in the voltage plateau during discharge is activation polarization.

Vaidyanathan, Hari

The 2004 NASA Aerospace Battery Workshop

Topics covered include: Super NiCd(TradeMark) Energy Storage for Gravity Probe-B Relativity Mission; Hubble Space Telescope 2004 Battery Update; The Development of Hermetically Sealed Aerospace Nickel-Metal Hydride Cell; Serial Charging Test on High Capacity Li-Ion Cells for the Orbiter Advanced Hydraulic Power System; Cell Equalization of Lithium-Ion Cells; The Long-Term Performance of Small-Cell Batteries Without Cell-Balancing Electronics; Identification and Treatment of Lithium Battery Cell Imbalance under Flight Conditions; Battery Control Boards for Li-Ion Batteries on Mars Exploration Rovers; Cell Over Voltage Protection and Balancing Circuit of the Lithium-Ion Battery; Lithium-Ion Battery Electronics for Aerospace Applications; Lithium-Ion Cell Charge Control Unit; Lithium Ion Battery Cell Bypass Circuit Test Results at the U.S. Naval Research Laboratory; High Capacity Battery Cell By-Pass Switches: High Current Pulse Testing of Lithium-Ion; Battery By-Pass Switches to Verify Their Ability to Withstand Short-Circuits; Incorporation of Physics-Based, Spatially-Resolved Battery Models into System Simulations; A Monte Carlo Model for Li-Ion Battery Life Projections; Thermal Behavior of Large Lithium-Ion Cells; Thermal Imaging of Aerospace Battery Cells; High Rate Designed 50 Ah Li-Ion Cell for LEO Applications; Evaluation of Corrosion Behavior in Aerospace Lithium-Ion Cells; Performance of AEA 80 Ah Battery Under GEO Profile; LEO Li-Ion Battery Testing; A Review of the Feasibility Investigation of Commercial Laminated Lithium-Ion Polymer Cells for Space Applications; Lithium-Ion Verification Test Program; Panasonic Small Cell Testing for AHPS; Lithium-Ion Small Cell Battery Shorting Study; Low-Earth-Orbit and Geosynchronous-Earth-Orbit Testing of 80 Ah Batteries under Real-Time Profiles; Update on Development of Lithium-Ion Cells for Space Applications at JAXA; Foreign Comparative Technology: Launch Vehicle Battery Cell Testing; 20V, 40 Ah Lithium Ion Polymer Battery for the Spacesuit; Low Temperature Life-Cycle Testing of a Lithium-Ion Battery for Low-Earth-Orbiting Spacecraft; and Evaluation of the Effects of DoD and Charge Rate on a LEO Optimized 50 Ah Li-Ion Aerospace Cell.

Source record