Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Feature‐shared adaptive‐boost deep learning for invasiveness classification of pulmonary subsolid nodules in CT images

Purpose In clinical practice, invasiveness is an important reference indicator for differentiating the malignant degree of subsolid pulmonary nodules. These nodules can be classified as atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), or invasive adenocarcinoma (IAC). The automatic determination of a nodule's invasiveness based on chest CT scans can guide treatment planning. However, it is challenging, owing to the insufficiency of training data and their interclass similarity and intraclass variation. To address these challenges, we propose a two‐stage deep learning strategy for this task: prior‐feature learning followed by adaptive‐boost deep learning. Methods The adaptive‐boost deep learning is proposed to train a strong classifier for invasiveness classification of subsolid nodules in chest CT images, using multiple 3D convolutional neural network (CNN)‐based weak classifiers. Because ensembles of multiple deep 3D CNN models have a huge number of parameters and require large computing resources along with more training and testing time, the prior‐feature learning is proposed to reduce the computations by sharing the CNN layers between all weak classifiers. Using this strategy, all weak classifiers can be integrated into a single network. Results Tenfold cross validation of binary classification was conducted on a total of 1357 nodules, including 765 noninvasive (AAH and AIS) and 592 invasive nodules (MIA and IAC). Ablation experimental results indicated that the proposed binary classifier achieved an accuracy of with an AUC of 81.3 . These results are superior compared to those achieved by three experienced chest imaging specialists who achieved an accuracy of , , and , respectively. About 200 additional nodules were also collected. These nodules covered 50 cases for each category (AAH, AIS, MIA, and IAC, respectively). Both binary and multiple classifications were performed on these data and the results demonstrated that the proposed method definitely achieves better performance than the performance achieved by nonensemble deep learning methods. Conclusions It can be concluded that the proposed adaptive‐boost deep learning can significantly improve the performance of invasiveness classification of pulmonary subsolid nodules in CT images, while the prior‐feature learning can significantly reduce the total size of deep models. The promising results on clinical data show that the trained models can be used as an effective lung cancer screening tool in hospitals. Moreover, the proposed strategy can be easily extended to other similar classification tasks in 3D medical images.

Wang, Jun↗

Using transparent fish to observe barotrauma associated with downstream passage through hydropower turbines

During downstream passage of hydroelectric facilities, fish can be injured by rapid decompression; this is especially noted during hydroturbine passage. The rapid decrease in pressure can cause barotrauma as undissolved gas expands according to Boyle’s law. However, it is difficult to see barotrauma occurring within the body of the fish in real time. In order to determine if transparent fish could provide greater insight into barotrauma, five species of transparent tropical fish were exposed to rapid decompressions so internal injuries could be viewed noninvasively. Before and after photos were taken to review the injuries and high speed video allowed observations of barotrauma pathways in vivo. High speed video recordings show the expansion of the swim bladder and subsequent release of gas through the mouth and gills, and into the body cavity when the swim bladder ruptured. Post-decompression photographs show that many internal injuries were visible and included hemorrhaging and the presence of emphysema within the body cavity and tissues. These observations provide new opportunities to understand the pathways and effects of barotrauma.

13 HYDRO ENERGY↗

Use of Fluorescent Protein Reporters for Assessing and Detecting Genome Editing Reagents and Transgene Expression in Plants

Fluorescent protein reporters have been widely used for monitoring the expression of target genes in various engineered organisms. Although a wide range of analytical approaches (e.g., genotyping PCR, digital PCR, DNA sequencing) have been utilized to detect and identify genome editing reagents and transgene expression in genetically modified plants, these methods are usually limited to use in the late stages of plant transformation and can only be used invasively. Here we describe GFP- and eYGFPuv-based strategies and methods for assessing and detecting genome editing reagents and transgene expression in plants, including protoplast transformation, leaf infiltration, and stable transformation. These methods and strategies enable easy, noninvasive screening of genome editing and transgenic events in plants.

Yuan, Guoliang↗

Comparative Analysis of Imaging and Measurements of Micrometer-Scale Fracture Aperture Fields Within a Heterogeneous Rock Using PET and X-ray CT

Knowledge of the spatial distribution of fracture apertures is essential for reliable characterization of flow and transport processes in fractured systems and for better understanding of physicochemical matrix–fracture interactions. Here, we propose and test two image-based methods, thereby extending the current experimental capabilities to characterize aperture size distribution in structurally heterogeneous geologic porous media noninvasively. The first approach utilizes an inversion method based on the dataset acquired from positron emission tomography (PET) and the second approach considers an extension of the classic missing attenuation technique that relies on clinical X-ray computed tomography (X-ray CT). Independent sets of imaging experiments are conducted on a fractured basalt core with heterogeneous matrix properties and aperture distributions to compare the two methodologies. A repeat of each experiment is conducted to verify the proposed workflows. The performance of these two imaging techniques is systematically evaluated through the analysis of signal-to-noise ratio, minimum fracture size detectability, and measurement errors. While both approaches provide a reliable estimation of fracture aperture distributions, PET yields a signal-to-noise ratio that is substantially higher than the corresponding X-ray CT measurements. Furthermore, uncertainties of the aperture values for PET are considerably lower ($\bar {\sigma}_{\text {d}} = 15\%$) compared to those obtained from X-ray CT ($\bar {\sigma}_{\text {d}} = 29\%$), allowing for the detection of minimum aperture sizes of 20 $\mu$m with 70% confidence level. Finally, these approaches provide key experimental tools for better understanding dynamic hydromechanical fracture properties in geologic systems.

58 GEOSCIENCES↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computational investigation of hydrogen-induced phonon changes in carbon fiber

Optical vibrational spectroscopy has shown promise as a noninvasive means of monitoring the mechanical properties of carbon fiber (CF), which is increasingly used for industrial and consumer purposes. However, interpretation of optical vibrational spectra for solid materials is inferential, particularly when defects are present. Because inelastic neutron scattering (INS) spectroscopy is not subject to selection rules, the full vibrational spectra can be measured. And, identifying correlations between INS features and tensile properties can assist in the interpretation of spectra from more commonly used optical vibrational spectroscopic techniques, such as Raman and infrared (IR) spectroscopy. Recent INS experiments on high-performance commercial carbon fibers showed features near 900 and 1100 cm –1 in addition to a broad feature near 3000 cm –1 that increased in intensity with decreasing tensile strength. These features were assigned to hydrogen defects. Here, we use density functional theory to simulate the INS spectra of several hydrogen defect geometries in graphite as a model for carbon fiber structure units, confirming the experimental assignment of these peaks to hydrogen modes and providing insights into the structure and lattice dynamics of the defects.

36 MATERIALS SCIENCE↗

Analytical solution for partial heating on the exterior of the pipe with application to measuring fluid flow rate

An analytical model using Green’s functions for partial external heating of a pipe is developed, which results in an exact mathematical solution for the radial and axial temperature distribution in the pipe wall. Partial heating consists of a constant heat flux function imposed over a small section of the exterior of a pipe and for a limited time duration. The solution comprises steady-state and transient parts, and an algebraic identity is used to decrease the number of summation terms in the slowly-converging steady- state part. Intrinsic verification principles are used to verify the solution. As an example application, this transient solution is applied toward the development of a simple, noninvasive method for in-field measurement of the flow rate in pipes. Furthermore, to simulate this application, a pulse of energy is imposed to the wall of the pipe, and the developed mathematical solution is used to find the flow rate of the fluid inside the pipe. An optimal experiment is designed to find the best measurement location and time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and Atlas to Enable Targeting for Cardiac Radioablation Employing the American Heart Association Segmented Model

Cardiac radioablation using stereotactic body radiation therapy is gaining popularity as a noninvasive treatment for otherwise refractory ventricular arrhythmias. As radiation oncologists might be unaccustomed to the lexicon used by cardiologists to describe the location of arrhythmogenic foci, a preliminary guide to cardiac-specific anatomy and orientation is needed to foster effective communication between the radiation oncologist and cardiology team.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Cancer Targeted X-Ray Fluorescence Imaging via Gold Nanoparticles Functionalized With Prostate-Specific Membrane Antigen (PSMA)

The gold nanoparticle (GNP) as a promising theranostic probe has been increasingly studied. The tumor-targeting efficiency of GNPs is crucial to increase the therapeutic ratio. In this study, we developed PSMA-targeted GNPs to enhance GNP uptake in prostate cancer and developed an x-ray fluorescence imaging system to noninvasively monitor and assess GNP delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The impact of tritium phytoremediation on plant health as measured by fluorescence

Phytoremediation, using plants for soil, sediment, or water contaminant clean-up, is an established technology dependent on plant health. Tritium (3H), a radioactive isotope of hydrogen that is generally found in the environment as tritiated water (HTO), is a low-level beta emitter with a half-life of 12.32 years. Chlorophyll fluorescence (CF) for monitoring risk assessment of tritium to plant health was conducted at the Tritium Irrigation Facility (TIF) located on the US Department of Energy's Savannah River Site (SRS) near Aiken, SC. Two fluorometers were evaluated in conjunction with phytoremediation at the 25 –acre TIF where tritiated groundwater is being spray–irrigated on a mixed coniferous/deciduous forested watershed as a means of reducing tritium release to a nearby stream that serves as a tributary to the Savannah River. Tritium activity in irrigated water averaged 104 + 42 pCi mL -1 during the 2003 project. Fluorescence parameters measured by the two fluorometers were well correlated with each other (p < 0.0001). Tritium in water respired from oak leaves ranged up to 1845.13 pCi ml -1 and 2138.22 pCi ml -1 in pine needles. Trees in both the test and control sites were approximately 15 years old. In this report we demonstrated that fluorescence parameters provide an effective way to estimate the impact of HTO on plant health in a noninvasive, extremely rapid, and cost-effective manner. In the current study applying fluorometry, plants within the TIF phytoremediation site exposed to the site tritiated water were not significantly impacted by the tritium phytoremediation based on CF parameters as compared to the control, a nascent non-irrigated site.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Micro-photoluminescence mapping and Chemometrics for the rapid classification of rare earth materials

This article introduces advancements in chemically mapping rare earth materials using photoluminescence (PL) and chemometrics. By leveraging the high sensitivity and selectivity of PL compared to alternative optical techniques, as well as its compatibility with microscopy, we present enhanced capabilities for noninvasive material screening and characterization. Exemplary PL spectra of samarium(III) and europium(III) in oxide, nitrate, and chloride forms demonstrated the ability to extract detailed chemical information of diverse rare earth particles. Additionally, we introduced efficient PL mapping sequences capable of covering a 9 mm diameter carbon tab within minutes, which highlighted the benefits of rapid, large-area imaging. Furthermore, an integrated approach combining PL mapping with principal component analysis and a random forest classifier enabled the resolution of overlapping spectral peaks from different chemistries and provided accurate material classification. In conclusion, these advancements underscored the versatility and robustness of PL for chemically mapping rare earth materials, with the potential to support applications in mining, energy, environmental monitoring, isotope production and beyond.

Chemometrics↗

Detector Characterization for Quantitative Spectral Radiography of Uranium Powder Samples

Pacific Northwest National Laboratory (PNNL) is developing a prototype spectral x-ray radiography (SpecX) non-destructive assay system for noninvasive material mass quantification of uranium-bearing powders. The SpecX system uses a custom material estimation algorithm, which requires a high-fidelity pixel-by-pixel detector response model for accurate quantification. We performed a detailed characterization and built a model of a High-Energy X-ray Imaging Technology (HEXITEC) CdTe pixelated spectral detector. Here we present the detector characterization which led to that model, including a determination of the pixel-wise energy calibration, the detection efficiency, the detector uniformity, the detector stability, and a comparison of methods to remove charge-shared events.

spectral X-ray radiography, pixelated detector, ca↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Resonance ultrasound prediction of residual stress within a hybrid layer for additively manufactured samples

Hybrid additive manufacturing (AM) involves secondary processes or energy sources to alter specified locations within the build volume. Each hybrid step can refine the grain size, increase dislocation density, or modify residual stresses. Typically, the changes in mechanical properties are not confined within a single layer but have a compounding effect on preceding layers. Existing methods of measuring AM residual stress are limited in terms of their sensitivity, or they are destructive measurements. We propose using resonant ultrasound spectroscopy (RUS) to measure the residual stress in hybrid-AM components noninvasively, based on changes to the resonances, compared to a stress-free component. In this paper, we use finite element models to simulate residual stress in hybrid-AM components and to examine the sensitivity of RUS measurements in terms of frequency shifts and mode shapes with respect to single hybrid layers. Then, the RUS results are used to predict stress for a layer at a known location with unknown stress. Here, the approach highlights the capabilities of RUS to address an AM characterization challenge.

36 MATERIALS SCIENCE↗

Real-Time Detection of Hydrogen and Ammonia Isotopologues for Impurity Removal and Recovery of Tritium

To accommodate gas measurements for impurity removal and recovery of tritium, a silver-coated optical or waveguide is employed for collecting Raman scattered signals to determine relative hydrogen and ammonia isotopologue populations in real time. The data and results presented here demonstrate an analytical methodology for the analysis of four ammonia and three hydrogen isotopologues in a hydrogen–deuterium exchange reaction by gas phase Raman spectroscopy. Standard chemometric modeling techniques effectively unravel the signatures of the isotopologues involved observed here; however, a sophisticated quantum chemical approach supports the spectral assignments. An interpretation of the data presented here can emphasize the practicality and reliability of the gaseous monitoring system in complex chemical environments for the hydrogen fuel economy as well as the more distant energy source from a facility that handles tritium. There are still considerable concerns about the measurement of tritium in isotope separation and radiological impurities from gas processing. A common impurity in gas processing is ammonia, which can form readily in the presence of nitrogen and tritium. Substituted ammonia (NQ 3 ), where Q = H, D, or T, is traditionally removed through getters or diffusers along with other non-hydrogen contaminants. A preferable analytical approach is noninvasive and can be deployed for real-time process evaluation in radiological environments.

Ammonia↗

UV–Vis–NIR Reflectance Spectroscopy and Chemometrics for Monitoring Pu Directly on an Ion Exchange Column

Here, we present a fiber-optic UV–vis–NIR reflectance spectroscopy method for direct, noninvasive monitoring of Pu(IV) in a glass ion exchange column during dynamic loading and elution in a glovebox. A movable probe enables spatially resolved spectral acquisition along the column axis, capturing distinct features associated with Pu(IV) nitrate complexes during loading and free ions during elution. Principal component analysis was applied to extract the dominant spectral variance and resolve relative concentration profiles without requiring precise knowledge of optical penetration depth or species identity. This in situ approach reveals spatial gradients and speciation dynamics in real time, which provides actionable insight into Pu(IV) ion migration, resin saturation, and breakthrough behavior under evolving flow conditions. The method offers a practical, fiber-compatible strategy to monitor glass column–based separations for Pu and other lanthanides or actinides and to characterize metal–resin interactions in flow-through systems.

actinide↗