Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear fusion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Neutronics Analysis for ITER Diagnostic Generic Upper Port Plug

This paper presents new results of neutronics analysis performed for the updated design of the ITER Diagnostic Generic Upper Port Plug (DGUPP). Such analysis is performed regularly during the development of the ITER Ports design. Neutronics analysis is an important step in support of the development of ITER components irradiated by 14 MeV neutrons generated in D-T fusion thermonuclear reactions. The neutrons are born in the ITER tokamak plasma chamber and then impinge on the surrounding blanket and port plugs, after that they diffuse through shielding material of vacuum vessel components or could stream through the diagnostic channels and assembly gaps far away from plasma up to the bio-shield and in a small amount beyond it. While ITER machine is in operation it is inaccessible, after the shut-down it is planned to provide personnel access to the Upper Port Inter-Space Structure (UP ISS) behind the Port Plug via the corridors. Neutrons activate the ITER materials and those radioactive materials emit decay gammas during the shut-down causing a Shut-Down Dose Rate (SDDR) field distributed all around the activated materials. Decay gammas could also stream through the void channels. That emphasizes the need for calculation of decay gamma transport in evaluations of SDDR, which is reflected in the use of transport - activation interface code described in Section of Computational Modelling. The assessment of radiation environment (fluxes and SDDR) at DGUPP was focused on the port back-side area of UP ISS, where personnel access is planned along the ISS maintenance corridors. Minimization of SDDR at the front part of the ISS maintenance corridors was the target value for optimization of the DGUPP shielding and analysis of related neutronics effects. Following the dose ALARA (As Low As Reasonably Achievable) principle, every possibility to reduce SDDR should be investigated, emphasizing the importance of this analysis. The challenges of such analysis are inextricably connected with the engineering complexity of the ITER machine, with integration of many diagnostics systems having channels and gaps inside the ITER ports. Those gaps result in radiation streaming and negatively affect the shielding performance of the port plugs. The computational complication is caused by the need to model precisely the ITER geometry and then to run deep penetrating radiation transport in the substantially heterogenic toroidal geometry of ITER large-size tokamak, with 30 m height and diameter of its bio-shield. The whole mass of Upper Port Plug (UPP) could be up to 25 tons and it must be very precisely positioned inside the port opening in blanket and Vacuum Vessel. Facing the engineering challenges for the assembly of DGUPP, there were proposed two Project Change Requests (PCRs) No. 439 and 709 concerning the design updates of UPP/blanket interface and its remote handling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Absolute calibration method for laser megajoule neutron yield measurement by activation diagnostics

The laser megajoule (LMJ) and the National Ignition Facility (NIF) plan to demonstrate thermonuclear ignition using inertial confinement fusion (ICF). The neutron yield is one of the most important parameters to characterize ICF experiment performance. For decades, the activation diagnostic was chosen as a reference at ICF facilities and is now planned to be the first nuclear diagnostic on LMJ, measuring both 2.45 MeV and 14.1 MeV neutron yields. Challenges for the activation diagnostic development are absolute calibration, accuracy, range requirement, and harsh environment. At this time, copper and zirconium material are identified for 14.1 MeV neutron yield measurement and indium material for 2.45 MeV neutrons. A series of calibrations were performed at Commissariat a l'Energie Atomique (CEA) on a Van de Graff facility to determine activation diagnostics efficiencies and to compare them with results from calculations. The CEA copper activation diagnostic was tested on the OMEGA facility during DT implosion. Experiments showed that CEA and Laboratory for Laser Energetics (LLE) diagnostics agree to better than 1% on the neutron yield measurement, with an independent calibration for each system. Also, experimental sensitivities are in good agreement with simulations and allow us to scale activation diagnostics for the LMJ measurement range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study on the neutron monitoring system of LHD based on Monte Carlo simulations

Neutron monitoring is quite important because fusion neutrons are a direct evidence of fusion reactions. In calibration experiments of a neutron monitoring system, Monte Carlo calculations play an important role to correct various effects. To perform Monte Carlo calculations for a helical type fusion device, we make a program that can automatically generate an input file of a helical coil geometry for the MCNP code. The neutron spatial distributions and spectra for the helical devices are calculated in the geometries automatically generated by this program. We also discuss in calibration experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metastable helium density probe for remote plasmas

Helium metastable atom density was spatially determined by a modified electrostatic probe in a remote plasma. The probe structure was similar to that of a guard ring probe. Opposite polarity voltages were applied to the inner probe and the guard ring to shield both electrons and ions from the vicinity of the inner probe. Therefore, the inner probe current is due to secondary electrons generated by the de-exciting helium metastable atom flux. The photoelectron current was removed by shielding and orienting the probe 90 deg. to the direction of the plasma-generated photon flux. Helium metastable atom density on the order of 10{sup 7} cm{sup -3} was measured. Limitations on the use of this technique are revealed by comparisons with simulated metastable distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical simulation of Li-pellet injection experiments for ELM-pacing in EAST

The injection of light impurity granules into fusion research discharges has shown a great potential for ELM pacing in future nuclear devices. The present work employed a model considering both pellet ablation and transport to systematically study for the first time the evolution of both impurity Li species and target plasma in the edge plasma during single and repeated Li pellet injections, with all initial information extracted from the EAST experiments. The evolutionary distributions of atomic and ionized Li species were presented and show good consistency with experimental CCD camera images. Simulation studies were carried out for single and repeated pellet injections at the outer mid-plane, and statistical uncertainty of ELM pacing rates triggering ELMs is discussed with regard to related injection conditions. It is found that the pressure locally caused by an ELM pacing pellet (with a diameter of 0.6 ~ 0.7 mm) was 1.8–2.4 times its unperturbed magnitude in the EAST shots of interest. Accumulation from repeated pellet injections results in the rise of pedestal height at a high injection frequency and this effect becomes stronger with increasing pellet size. Pressure changes are also evident in a scenario of multiple small pellets per stroke, which could lead to a nonnegligible, probabilistic ELM triggering rate observed experimentally. The effects of other possible factors are also discussed. With the assumption that the ELM trigger rate of a Li pellet of 0.7 mm diameter is 100%, the predicted trigger rates are in good agreement with those observed in experiments. This work can help understand the statistically probabilistic behavior of ELM triggering efficiency observed in previous studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of Multi-Step CADIS Parameter Sensitivity to Neutron Flux Spectrum in Shutdown Dose Rate Calculations

Shutdown dose rate (SDDR) analysis requires (a) a neutron transport calculation to estimate neutron flux fields, (b) an activation calculation to compute radionuclide inventories and associated photon sources, and (c) a photon transport calculation to estimate final dose rate. In some applications, accurate full-scale Monte Carlo (MC) SDDR simulations are needed for very large systems with massive amounts of shielding materials. For example, SDDR assessments are required throughout the biological shield (bio-shield) of the ITER experimental facility to evaluate the required waiting period after the shutdown of ITER and to identify the locations where human accessibility should be prohibited. The bio-shield is a large cylindrical concrete structure (30 m tall and 34 m in diameter) surrounding the very complex tokamak machine. Determining the effects on SDDR of important factors, such as the cross talk (interactions) between the different ports of ITER, is possible only through full-scale simulations that involve all the complex inner details of the ITER tokamak machine. These simulations are impractical because calculation of space- and energy-dependent neutron fluxes throughout the structural materials is needed to estimate the distribution of radioisotopes causing the SDDR. Determining a good importance function that can be used in biasing a neutron MC calculation for SDDR is complicated because it is difficult to explicitly express the SDDR response function, which depends on subsequent computational steps. The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid MC/deterministic method was developed to speed up the SDDR MC neutron transport calculation using an importance function that represents the neutron importance to the final SDDR. The MS-CADIS method uses the CADIS method, which has been Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC0500OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for the United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). successfully used for more than a decade in radiation shielding applications to generate consistent source biasing and weight window (WW) variance reduction parameters to accelerate continuous-energy MC simulations. However, because MS-CADIS focuses on multi-step shielding calculations such as SDDR calculations, it develops an importance function for the initial radiation transport calculation (e.g., the neutron calculations in SDDR simulations) that represents the importance of particles to the final response of the overall simulation. To develop this importance function, the MS-CADIS method uses an adjoint calculation with a specific neutron adjoint source that represents the neutron's contribution to the final SDDR. Brute force calculation of the MS-CADIS neutron adjoint source requires a deterministic neutron transport calculation coupled with activation calculations in each element of the deterministic mesh. These calculations are needed to determine the MS-CADIS parameter for the neutron interactions that produce radioisotopes contributing to the SDDR. The MS-CADIS parameter is the microscopic cross section of the radioisotope-producing interaction, multiplied by the mass of this radioisotope existing at the end of the irradiation and decay scenario, and divided by the steady-state rate of the interaction. Because the activation calculations are performed for each radionuclide in each mesh element, implementation of the MS-CADIS method can be computationally expensive. However, these neutron transport and activation calculations are not needed if we assume that the radioisotopes are created due to single neutron interactions and their concentrations do not change as a result of burnup by neutron irradiation. The use of this approximation, which renders the MS-CADIS parameter independent of the neutron flux, seems reasonable in calculating the MS-CADIS importance function because this function is needed only to speed up the MC calculation, not to calculate the final SDDR. In this work, we investigate the validity of this approximation by investigating the behavior of the MS-CADIS parameter as a function of the neutron flux spectra in the Fusion Evaluated Nuclear Data Library (FENDL) Neutronics and Shielding Benchmark problem that contains representative isotopes and flux environments of fusion energy systems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, iontemperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The dynamic radiation environment assimilation model (DREAM)

The Dynamic Radiation Environment Assimilation Model (DREAM) is a 3-year effort sponsored by the US Department of Energy to provide global, retrospective, or real-time specification of the natural and potential nuclear radiation environments. The DREAM model uses Kalman filtering techniques that combine the strengths of new physical models of the radiation belts with electron observations from long-term satellite systems such as GPS and geosynchronous systems. DREAM includes a physics model for the production and long-term evolution of artificial radiation belts from high altitude nuclear explosions. DREAM has been validated against satellites in arbitrary orbits and consistently produces more accurate results than existing models. Tools for user-specific applications and graphical displays are in beta testing and a real-time version of DREAM has been in continuous operation since November 2009.

58 GEOSCIENCES↗

Development, validation, and verification of multi-pass thermo-mechanical welding simulations using the open-source MOOSE framework: NeT TG4 benchmark weldment

This study develops and validates a sequentially coupled thermo-mechanical welding simulation for the three-pass 316L stainless steel NeT TG4 benchmark weldment using the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) and the Nuclear Engineering Material model Library (NEML). A diffused ellipsoidal heat source was calibrated against thermocouple data and weld macrographs to accurately model the fusion zone geometry and transient thermal fields. Material hardening is represented using the Lemaitre-Chaboche mixed isotropic-kinematic hardening model, while four annealing models - no annealing, single-stage at 1050 °C and 1300 °C, and two-stage at 800 °C/1300 °C - were implemented to assess the impact of annealing models on the accuracy of the predicted welding-induced plasticity, distortions, and residual stresses. The predictions were validated against experimental measurements and benchmarked against results from commercial software, demonstrating that thermo-mechanical MOOSE welding simulations achieve comparable accuracy with enhanced computational efficiency. This work highlights the potential of using open-source finite element frameworks like MOOSE for advanced manufacturing simulations.

Ji, Wendy [Australian Nuclear Science and Technolo↗

Neutron emission during the implosion of a wire array onto a deuterated fiber

Results are presented from Z-pinch experiments performed in the S-300 facility (Kurchatov Institute) at a maximum current of 2 MA and current rise time of 100 ns. The Z-pinch load was a 1-cm-long 1-cmdiameter cylindrical array made of 40 tungsten wires with a total mass of 160 {mu}g, at the axis of which a 100-{mu}m-diameter (CD{sub 2}){sub n} deuterated fiber was installed. Hard X-ray and neutron signals were recorded using five scintillation detectors oriented in one radial and two axial directions. The maximum neutron yield from the DD reaction reached 3 x 10{sup 9} neutrons per shot. The average neutron energy was determined from time-of-flight measurements and Monte Carlo simulations under the assumption that the neutron emission time was independent of the neutron energy. The average neutron energy in different experiments was found to vary within the range 2.5-2.7 MeV. The fact that the average neutron energy was higher than 2.45 MeV (the energy corresponding to the DD reaction) is attributed to the beam-target collisional mechanism for the acceleration of deuterons to 100-500 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helium measurements simulating alpha-particle diagnostics by the pellet charge exchange in Large Helical Device

It is very important to investigate the confinement of {alpha} particle, which is produced by the nuclear reaction in ITER or fusion reactor. The pellet charge exchange measurement (PCX) is one of the most powerful methods because it can directly provide the profile of {alpha} particle energy spectra in plasma. In Large Helical Device (LHD), it is possible to confine the high energetic particle (helium) accelerated by using the ion cyclotron resonance heating (ICH). Therefore it is possible to perform the simulation experiment of {alpha} particle diagnostic in LHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The NIF x-ray spectrometer calibration campaign at Omega

The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the OMEGA laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2–18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear yield reduction in inertial confinement fusion exploding-pusher targets explained by fuel-pusher mixing through hybrid kinetic-fluid modeling

In inertial confinement fusion implosion experiments involving fast laser heating of glass capsules containing gaseous nuclear fuel, some nuclear measurements cannot be rendered by standard hydrodynamics numerical simulations. Here, the calculated values of the nuclear yield are found to be too high by more than a decade in some cases. The first kinetic simulations of the enclosed reacting gas have bridged only half that gap. In this Rapid Communication, using a hybrid ion kinetic-fluid numerical model which takes into account the kinetic interaction between the fuel and the pusher, we reach full agreement with the experimental yield data. We thus unambiguously demonstrate that the kinetic behavior of the system, resulting in both nonthermodynamic equilibrium of the ions comprising the fuel and strong pusher-fuel mixing, is the correct interpretation of the data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling law of electron confinement in a zero beta polywell device

Orbital theory simulation was applied to an electron trap that uses a cube shaped magnetic cusp known as a Polywell device. The purpose of this device is to create a virtual cathode in order to achieve nuclear fusion using inertial electrostatic confinement. Analytical expressions of the electron confinement time and average position within the device were obtained in terms of the current in the field coils, the dimensions of the device, and the kinetic energy of the electrons. Comparisons with numerical simulations showed good agreement over a parameter range that spanned several orders of magnitude for the current. In addition, power loss from electrons exiting the trap was estimated in order to obtain minimum power requirement to maintain a virtual cathode within the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards a novel laser-driven method of exotic nuclei extraction−acceleration for fundamental physics and technology

A combination of a petawatt laser and nuclear physics techniques can crucially facilitate the measurement of exotic nuclei properties. With numerical simulations and laser-driven experiments we show prospects for the Laser-driven Exotic Nuclei extraction–acceleration method proposed in [M. Nishiuchi et al., Phys, Plasmas 22, 033107 (2015)]: a femtosecond petawatt laser, irradiating a target bombarded by an external ion beam, extracts from the target and accelerates to few GeV highly charged short-lived heavy exotic nuclei created in the target via nuclear reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elastic Properties of Plasma-Exposed Tungsten Predicted by Molecular-Dynamics Simulations

We report results of systematic molecular-dynamics computations of the elastic properties of single-crystalline tungsten containing structural defects, voids and overpressurized He nanobubbles, related to plasma exposure of tungsten serving as a plasma- facing component (PFC) in nuclear fusion devices. Our computations reveal that the empty voids are centers of dilatation resulting in development of tensile stress in the tungsten matrix, whereas He-filled voids (nanobubbles) introduce compressive stress in the plasma-exposed tungsten. We find that the dependence of the elastic moduli of plasma-exposed tungsten, namely, the bulk, Young, and shear modulus, on its void fraction follows a universal exponential scaling relation. We also find that the elastic moduli of plasma-exposed tungsten soften substantially as a function of He content in the tungsten matrix, following an exponential scaling relation; this He-induced exponential softening is in addition to the softening caused in the matrix with increasing temperature. A systematic characterization of the dependence of the elastic moduli on the He bubble size reveals that He bubble growth affects significantly both the bulk modulus and the Poisson ratio of plasma-exposed tungsten, while its effect on the Young and shear moduli of the plasma-exposed material is weak. Our findings contribute directly to the development of a structure-properties database that is required for the predictive modeling of the dynamical response of PFCs in nuclear fusion devices.

36 MATERIALS SCIENCE↗

Conceptual design of a versatile radiation tolerant integrated signal conditioning circuit for resistive sensors

This paper presents the design of a radiation tolerant configurable discrete time CMOS signal conditioning circuit for use with resistive sensors like strain gauge pressure sensors. The circuit is intended to be used for remote handling in harsh environments in the International Thermonuclear Experimental fusion Reactor (ITER). The design features a 5 V differential preamplifier using a Correlated Double Sampling (CDS) architecture at a sample rate of 20 kHz and a 24 V discrete time post amplifier. The gain is digitally controllable between 27 and 400 in the preamplifier and between 1 and 8 in the post amplifier. The nominal input referred noise voltage is only 8.5 {mu}V while consuming only 1 mW. The circuit has a simulated radiation tolerance of more than 1 MGy. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗