Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Automated ISS Flight Utilities

During my internship at NASA Johnson Space Center, I worked in the Space Radiation Analysis Group (SRAG), where I was tasked with a number of projects focused on the automation of tasks and activities related to the operation of the International Space Station (ISS). As I worked on a number of projects, I have written short sections below to give a description for each, followed by more general remarks on the internship experience. My first project is titled "General Exposure Representation EVADOSE", also known as "GEnEVADOSE". This project involved the design and development of a C++/ ROOT framework focused on radiation exposure for extravehicular activity (EVA) planning for the ISS. The utility helps mission managers plan EVAs by displaying information on the cumulative radiation doses that crew will receive during an EVA as a function of the egress time and duration of the activity. SRAG uses a utility called EVADOSE, employing a model of the space radiation environment in low Earth orbit to predict these doses, as while outside the ISS the astronauts will have less shielding from charged particles such as electrons and protons. However, EVADOSE output is cumbersome to work with, and prior to GEnEVADOSE, querying data and producing graphs of ISS trajectories and cumulative doses versus egress time required manual work in Microsoft Excel. GEnEVADOSE automates all this work, reading in EVADOSE output file(s) along with a plaintext file input by the user providing input parameters. GEnEVADOSE will output a text file containing all the necessary dosimetry for each proposed EVA egress time, for each specified EVADOSE file. It also plots cumulative dose versus egress time and the ISS trajectory, and displays all of this information in an auto-generated presentation made in LaTeX. New features have also been added, such as best-case scenarios (egress times corresponding to the least dose), interpolated curves for trajectories, and the ability to query any time in the EVADES output. As mentioned above, GEnEVADOSE makes extensive use of ROOT version 6, the data analysis framework developed at the European Organization for Nuclear Research (CERN), and the code is written to the C++11 standard (as are the other projects). My second project is the Automated Mission Reference Exposure Utility (AMREU).Unlike GEnEVADOSE, AMREU is a combination of three frameworks written in both Python and C++, also making use of ROOT (and PyROOT). Run as a combination of daily and weekly cron jobs, these macros query the SRAG database system to determine the active ISS missions, and query minute-by-minute radiation dose information from ISS-TEPC (Tissue Equivalent Proportional Counter), one of the radiation detectors onboard the ISS. Using this information, AMREU creates a corrected data set of daily radiation doses, addressing situations where TEPC may be offline or locked up by correcting doses for days with less than 95% live time (the total amount time the instrument acquires data) by averaging the past 7 days. As not all errors may be automatically detectable, AMREU also allows for manual corrections, checking an updated plaintext file each time it runs. With the corrected data, AMREU generates cumulative dose plots for each mission, and uses a Python script to generate a flight note file (.docx format) containing these plots, as well as information sections to be filled in and modified by the space weather environment officers with information specific to the week. AMREU is set up to run without requiring any user input, and it automatically archives old flight notes and information files for missions that are no longer active. My other projects involve cleaning up a large data set from the Charged Particle Directional Spectrometer (CPDS), joining together many different data sets in order to clean up information in SRAG SQL databases, and developing other automated utilities for displaying information on active solar regions, that may be used by the space weather environment officers to monitor solar activity. I consulted my mentor Dr. Ryan Rios and Dr. Kerry Lee for project requirements and added features, and ROOT developer Edmond Offermann for advice on using the ROOT library. I also received advice and feedback from Dr. Janet Barzilla of SRAG, who tested my code. Besides these inputs, I worked independently, writing all of the code by myself. The code for all these projects is documented throughout, and I have attempted to write it in a modular format. Assuming that ROOT is updated accordingly, these codes are also Y2038-compliant (and Y10K-compliant). This allows the code to be easily referenced, modified and possibly repurposed for non-ISS missions in the future, should the necessary inputs exist. These projects have taught me a lot about coding and software design - I have become a much more skilled C++ programmer and ROOT user, and I also learned to code in Python and PyROOT (and its advantages and disadvantages compared to C++/ ROOT). Furthermore, I have learned about space radiation and radiation modeling, topics that greatly interest me as I pursue a degree in physics. Working alongside experimental physicists like Dr. Rios, I have developed a greater understanding and appreciation for experimental science, something I have always leaned towards but to which I lacked significant exposure. My work in SRAG has also given me the invaluable opportunity to witness the work environment for physicists at NASA, and what a career in academia may look like at a government laboratory such as NASA Johnson Space Center. As I continue my studies and look forward to graduate school and a future career, this experience at NASA has given me a meaningful and enjoyable opportunity to put my skills to use and see what my future career path might hold.

Offermann, Jan Tuzlic↗

Neutron influences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (E(sub n) less than or equal to 0.2 eV), resonance (0.2 eV less than E(sub n) less than 1.0 MeV) and fast (E(sub n) greater than or equal to 1.0 MeV) neutrons. The first two groups were measured with U.S. (6)LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d(exp -1) were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d(exp -1). Inside the spacecraft, a value of 3.5 mrem d(exp -1) was found.

Dudkin, V. E.↗

To the solar foci

Earlier authors showed that the sun is likely to act as a lens for gravitational radiation, with focui in the outer solar system. They suggested that missions to these foci have the potential of directly measuring the density structure of the sun. Other applications include gravitational wave astronomy and tests of general relativity. This idea is reexamined, concentrating on the engineering aspects of focal missions; primarily spacecraft design and performance. Other topics studied include solar optics, gravitational wave detectors, navigation, and the design of missions for different purposes. Specifically, it is shown that shuttle launched chemical rockets have a substantial capability for reaching some foci; and that all can be reached with large payloads using nuclear isotope-electric propulsion.

Sonnabend, D.↗

A high-resolution study of ultra-heavy cosmic-ray nuclei (A0178)

The main objective of the experiment is a detailed study of the charge spectra of ultraheavy cosmic-ray nuclei from zinc (Z = 30) to uranium (Z = 92) and beyond using solid-state track detectors. Special emphasis will be placed on the relative abundances in the region Z or - 65, which is thought to be dominated by r-process nucleosynthesis. Subsidiary objectives include the study of the cosmic-ray transiron spectrum a search for the postulated long-lived superheavy (SH) nuclei (Z or = 110), such as (110) SH294, in the contemporary cosmic radiation. The motivation behind the search for super-heavy nuclei is based on predicted half-lives that are short compared to the age of the Earth but long compared to the age of cosmic rays. The detection of such nuclei would have far-reaching consequences for nuclear structure theory. The sample of ultraheavy nuclei obtained in this experiment will provide unique opportunities for many tests concerning element nucleosynthesis, cosmic-ray acceleration, and cosmic-ray propagation.

Osullivan, D.↗

Summary of LET spectra and dose measurements on ten STS missions

A comparison of linear energy transfer (LET) spectra measurements made with plastic nuclear track detectors (PNTD's) from area passive dosimeters (APD's), was made for ten different STS missions under similar shielding. The results show that integral flux, dose rate and equivalent dose rate values follow a general increase with respect to increasing orbital inclination and altitude but that there are large variations from a simple relationship. This is to be expected since it has been shown that Shuttle attitude variations, combined with the anisotropic particle flux at the South Atlantic Anomaly (SAA), can result in differences of a factor of 2 in dose rate inside the Shuttle (Badhwar et al., 1995). Solar cycle and shielding differences also result in variations in radiation dose between STS missions. Spaceflight dosimeters from the STS missions are also being used in the development of a method for increasing LET spectra measurement accuracy by extending LET measurements to particle tracks of ranges 10-80 microns. Refinements in processing and measurement techniques for the flight PNTD's have yielded increased detection efficiencies for the short tracks when LET spectra determined by using the standard and refined methods were intercompared.

Source record↗

Probability of cell hits in selected organs and tissues by high-LET particles at the ISS orbit

The fluence of high-LET particles (HLP) with LET infinity H2O greater than 15 keV micrometers-1 in selected organs and tissues were measured with plastic nuclear track detectors using a life-size human phantom on the 9th Shuttle-Mir Mission (STS-91). The planar-track fluence of HLP during the 9.8-day mission ranged from 1.9 x 10(3) n cm-2 (bladder) to 5.1 x 10(3) n cm-2 (brain) by a factor of 2.7. Based on these data, a probability of HLP hits to a matured cell of each organ or tissue was roughly estimated for a 90-day ISS mission. In the calculation, all cells were assumed to be spheres with a geometric cross-sectional area of 500 micrometers2 and the cell-hit frequency from isotropic space radiation can be described by the Poisson-distribution function. As results, the probability of one or more than 1 hit to a single cell by HLP for 90 days ranged from 17% to 38%; that of two or more than 2 hits was estimated to be 1.3-8.2%. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

NASA Discipline Radiation Health↗

Electrolytic Co-deposition Neutron Production Evaluation

Co-deposition electrochemical cells are a simple means to examine novel nuclear reactions. In this study, palladium and deuterium atoms were co-deposited on a cathode at stoichiometric densities, forming dendritic morphologies. Bubble detector neutron dosimeters were used to measure equivalent dose levels during electrolytic deposition. Standard configuration cells expected to produce excess neutrons were denoted as experimental cells and contained an electrolyte consisting of palladium(II) chloride, lithium chloride, and heavy water. The control cells used copper(II) chloride, lithium chloride, and heavy water electrolyte. Experimental and control cells were supplied current, increasing from 0.1 to 100.0 mA over a period of 20 days. For test days 9 through 20, the standard configuration experimental cells exhibited significantly higher average neutron radiation than the controls at a 99% confidence level. Alternative configurations involving more increasing current over a shortened time scale, substitutions of water in place of heavy water or potassium chloride for lithium chloride, as well as inclusion of depleted uranium near the cell cathodes all resulted in inconclusive evidence for promoting neutron production.

neutron↗

Relative Abundances and Energy Spectra of C, N, and 0 as Measured by the Advanced Thin Ionization Calorimeter Balloon Experiment

We present results on the spectra and the relative abundances of C, N, and 0 nuclei in the cosmic radiation as measured from the Advanced Thin Ionization Calorimeter Balloon Experiment (ATIC) . The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon flight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate calorimeter. It is equipped with a large area mosaic of silicon detector pixels capable of charge identification from H to Fe. As a redundancy check for the charge identification and a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target.

Fazely, A. R.↗

Feasibility of a nuclear gauge for fuel quantity measurement aboard aircraft

Capacitance fuel gauges have served as the basis for fuel quantity indicating systems in aircraft for several decades. However, there have been persistent reports by the airlines that these gauges often give faulty indications due to microbial growth and other contaminants in the fuel tanks. This report describes the results of a feasibility study of using gamma ray attenuation as the basis for measuring fuel quantity in the tanks. Studies with a weak Am-241 59.5-keV radiation source indicate that it is possible to continuously monitor the fuel quantity in the tanks to an accuracy of better than 1 percent. These measurements also indicate that there are easily measurable differences in the physical properties and resultant attenuation characteristics of JP-4, JP-5, and Jet A fuels. The experimental results, along with a suggested source-detector geometrical configuration are described.

Signh, J. J.↗

Lunar occultations for gamma-ray source measurements

The unambiguous association of discrete gamma-ray sources with objects radiating at other wavelengths, the separation of discrete sources from the extended emission within the Galaxy, the mapping of gamma-ray emission from nearby galaxies and the measurement of structure within a discrete source cannot presently be accomplished at gamma-ray energies. In the past, the detection processes used in high-energy gamma-ray astronomy have not allowed for good angular resolution. This problem can be overcome by placing gamma-ray detectors on the moon and using the horizon as an occulting edge to achieve arcsec resolution. For purposes of discussion, this concept is examined for gamma rays above 100 MeV for which pair production dominates the detection process and locally-generated nuclear gamma rays do not contribute to the background.

Koch, David G.↗

Radiation exposure of LDEF: Initial results

Initial results from Long Duration Exposure Facility (LDEF) include radiation detector measurements from four experiments; P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also at the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose dependence of a factor of approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly (SAA). On the trailing edge of the orbiter, a range of doses from 664 to 291 rad were measured under nominal shielding of 0.42 to 8.45 g/sq cm. A second set of detectors near this locations results are also given. On the leading edge, doses of 258 to 210 rad were found under shielding of 1.25 to 2.48 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses, and dose equivalents, for LET in H2O greater than or = 5 keV/micron, were measured with plastic nuclear track detectors located in the four experiments. Also, preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗

Exclusive measurements of mean pion multiplicities in 4He-nucleus reactions from 200 to 800 MeV/nucleon

Mean multiplicities of pi+ and pi- in 4He collisions with C, Cu, and Pb at 200, 600, and 800 MeV/u, and with C and Pb at 400 MeV/u have been measured using the large solid angle detector Diogene. The independence of pion multiplicity on projectile incident energy, target mass and proton multiplicity is studied in comparison with intra-nuclear cascade predictions. The discrepancy between experimental results and theory is pointed out and discussed.

NASA Discipline Radiation Health↗

Effective dose equivalent on the ninth Shuttle--Mir mission (STS-91)

Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).

NASA Center JSC↗

Three-dimensional shielding effects on charged particle fluences measured in the P0006 experiment of LDEF

Three-dimensional shielding effects on cosmic ray charged particle fluences were measured with plastic nuclear track detectors in the P0006 experiment on Long Duration Exposure Facility (LDEF). The azimuthal and polar angle distributions of the galactic cosmic ray particles (mostly relativistic iron) were measured in the main stack and in four side stacks of the P0006 experiment, located on the west end of the LDEF satellite. A shadowing effect of the shielding of the LDEF satellite is found. Total fluence of stopping protons was measured as a function of the position in the main and side stacks of the P0006 experiment. Location dependence of total track density is explained by the three-dimensional shielding model of the P0006 stack. These results can be used to validate 3D mass model and transport code calculations and also for predictions of the outer radiation environment for the Space Station Freedom.

Csige, I.↗

Performance of bismuth germanate active shielding on a balloon flight over Antarctica

The GRAD (Gamma-Ray Advanced Detector) gamma-ray spectrometer was flown on a balloon at an altitude of 36.6 km over Antarctica on January 8-10, 1988, where it was used to make observations of SN 1987A. The performance of the bismuth germanate (BGO) active shielding in the near-space environment over Antarctica is examined. The promised effectiveness of this shielding in the suppression of unwanted background has been demonstrated. The BGO-shielded GRAD spectrometer detected gamma-ray lines with fluxes of 0.002/sq cm sec from SN 1987A in a radiation background approximately a factor of 4 more intense than that over Alice Springs, Australia. This level of sensitivity indicates that BGO is at least as effective as CsI when used as active shielding. Isomerism is common, both in the bismuth and germanium regions of the nuclear chart, but is found to be less of a problem for background suppression in the latter region than in the former.

Rester, A. C.↗

Radiation exposure of LDEF: Initial results

Initial results from LDEF include radiation detector measurements from four experiments, P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also on the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose ratio dependence of a factor approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly. On the trailing edge of the orbiter a range of doses from 6.64 to 2.91 Gy were measured under Al equivalent shielding of 0.42 to 1.11 g/sq cm. A second set of detectors near this location yielded doses of 6.48 to 2.66 Gy under Al equivalent shielding of 0.48 to 15.4 g/sq cm. On the leading edge, doses of 2.58 to 2.10 Gy were found under Al equivalent shielding of 1.37 to 2.90 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses and dose equivalents, for LET in H2O greater than or = 8 keV/micron, were measured with plastic nuclear track detectors (PNTDs) located in two experiments. Also preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗

Fragmentation cross sections of 28Si at 14.5 GeV/nucleon

We used CR39 plastic nuclear track detectors (C12H18O7) in combination with automatic track measurement techniques to determine total charge changing and partial cross sections for the production of fragments of charge ZF = 6 to ZF = 13 in collisions of 28Si beam nuclei at 14.5 GeV/nucleon in targets H, C, CR39, (C18H38O), Al, Cu, Ag, and Pb. By application of factorization rules, measured partial cross sections are separated into pure nuclear and electromagnetic components. The cross sections for electromagnetic dissociation agree with theoretical models. The results are consistent with a Z2 dependence of virtual photon spectra.

NASA Discipline Number 04-10↗

A new method for internal calibration of nuclear track detectors

A new technique is proposed for an internal calibration of a two-layer detector assembly. Spatially coincident pairs of conical tracks on one surface and overetched tracks on the adjacent surface are selected for measurement. Both the etch rate ratio and the particle range can be obtained from the minor and major diameters of the elliptical track and the radii of the circular tracks for two etching steps. This technique was applied to CR-39 detectors exposed to fast neutrons and those flown on a high altitude balloon in order to evaluate the proton response. An improvement by using multi-step etching was also carried out. It was found that not only a single set of the etch rate ratio and the range but also the response curve could be estimated in an extended region by analyzing combined growth curves.

NASA Discipline Radiation Health↗