Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Neutrino energy transport in weak decoupling and big bang nucleosynthesis

In this study, we calculate the evolution of the early universe through the epochs of weak decoupling, weak freeze-out and big bang nucleosynthesis (BBN) by simultaneously coupling a full strong, electromagnetic, and weak nuclear reaction network with a multienergy group Boltzmann neutrino energy transport scheme. The modular structure of our code provides the ability to dissect the relative contributions of each process responsible for evolving the dynamics of the early universe in the absence of neutrino flavor oscillations. Such an approach allows a detailed accounting of the evolution of the νe, ν¯e, νμ, ν¯μ, ντ, ν¯τ energy distribution functions alongside and self-consistently with the nuclear reactions and entropy/heat generation and flow between the neutrino and photon/electron/positron/baryon plasma components. This calculation reveals nonlinear feedback in the time evolution of neutrino distribution functions and plasma thermodynamic conditions (e.g., electron-positron pair densities), with implications for the phasing between scale factor and plasma temperature; the neutron-to-proton ratio; light-element abundance histories; and the cosmological parameter N eff . We find that our approach of following the time development of neutrino spectral distortions and concomitant entropy production and extraction from the plasma results in changes in the computed value of the BBN deuterium yield. For example, for particular implementations of quantum corrections in plasma thermodynamics, our calculations show a 0.4% increase in deuterium. These changes are potentially significant in the context of anticipated improvements in observational and nuclear physics uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the Isospin Composition of Short-Range Correlated Pairs at Jefferson Lab Hall B

Nucleons in short-range correlated (SRC) pairs, due to their close proximity and high relative momentum, can provide insight into the short-range part of the strong nuclear interaction. In particular, the prevalence of np pairs is due to the dominance of a tensor term for correlated nucleons with momenta of approximately 400?600 MeV/c. This dissertation comprises two studies advancing the community?s understanding of the isospin composition of SRC pairs. First, I performed a study of proton and neutron knockout from initially low-momentum and high-momentum states in 3He. Previous work has shown that protons are disproportionately represented in high-momentum states in neutron-rich nuclei. I demonstrate that spectral functions for the proton-rich nucleus 3He predict, in agreement with data, that neutrons are disproportionately represented in high-momentum states, but that 3He does not display the same strong prevalence of np pairs that is observed in larger nuclei. Second, Generalized Contact Formalism (GCF), a well-supported theory for predicting SRC behavior, predicts the transition from an isospin-dependent, tensor-dominant interaction at intermediate distances to a scalar-dominant, isospin-independent interaction at very short distances. This dissertation uses data from the CLAS12 Nuclear Targets Experiments in Hall B at Jefferson Lab to measure the relative abundances of pp and pn pairs for increasing relative momentum and decreasing separation. I provide an independent confirmation of the previously-observed increase in pp pairs at increasing momentum of the struck nucleon. I also contribute to the application of the new CLAS12 Central Neutron Detector by precisely measuring the neutron detection efficiency and developing a machine learning model for rejecting charged particle background.

Seroka, Erin↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid state 59 Co NMR study of a Np(VII) compound

Np(VII) compounds with [Co(NH 3 ) 6 ] 3+ cations were synthesized and structurally examined using powder X-ray diffraction. Multiple phases were observed, consisting of octahedral [Co(NH 3 ) 6 ] 3+ cations, discrete tetragonal bipyramidal [NpO 4 (OH) 2 ] 3− anions, and waters of hydration. Electric field gradient tensors at Co sites were measured by solid state 59 Co nuclear magnetic resonance (NMR) spectroscopy and compared with theoretical calculations. The relative contributions of the chemical shift and electric field tensors to the NMR lineshape were determined by recording spectra at field strengths of 7.04 and 11.74 Tesla. Further, the evolution of structure and morphology as a function of sample age and the effects on NMR spectral parameters has also been investigated. These results demonstrate the use of NMR at multiple fields to expand understanding of the stability and electronic structure of high valent neptunium compounds.

heptavalent neptunium↗

Inelastic Neutron Spectra of Uranium Tetrafluoride Hydrate, UF 4 (H 2 O) 2.5

Uranium tetrafluoride hydrate (UFH) is formed by immersing anhydrous UF4 under water for 12 h. UFH is therefore clearly a chemical species of environmental concern, as anhydrous UF4 is an intermediate uranium form in the nuclear fuel cycle. We use inelastic neutron scattering (INS) to probe the full vibrational spectra of UFH and its deuterated analogue in an effort to improve the fundamental understanding of its vibrational spectra. Coupled with density functional theory (DFT) calculations, the first for this compound, and full spectral modeling, we generate the complete vibrational spectra of UFH and compare them to prior optical spectroscopic results. In particular, the combination of DFT with INS allows us to identify multiple distinct chemical environments in the water bending and OH stretching regions. Whereas the water molecules directly bound to the U atoms execute OH stretching around 3600 cm –1 , a second class of H-bonded waters vibrate below 3000 cm –1 , an indicator of strong H bonding. In addition, a class of librational water modes are observed between 400 and 900 cm–1, which themselves can be separated in energy according to their chemical environments. Furthermore, measurements presented herein directly assist in the assignment of certain spectral features in the infrared spectrum and will inform future investigations of UFH for environmental or forensics purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ITER diagnostic systems in development in Ioffe Institute

Three diagnostic systems are being developed in Ioffe Institute for ITER. Those are Neutral Particle Analysis (NPA), Thomson Scattering in Divertor (TSD) and Gamma Spectroscopy (GS). The main objective of NPA in ITER is to measure D/T fuel ration in plasma on the basis of measurement of neutralized fluxes of D and T ions [1]. Fuel ratio is one of the key parameters needed by ITER control system to provide the optimal conditions in plasma and the most effective plasma burning. Another objective is to measure the distribution function of fast ions (including alpha particles) generated as a result of the additional heating and nuclear fusion reactions. Thomson Scattering in Divertor (TSD) [2] will be used to measure electron temperature and density in the scrape-off layer in outer leg of ITER divertor. The main task of TSD is to protect the machine from divertor overloading. Gamma Spectroscopy (GS) [3] is based on the measurement of spectral lines of MeV range gammas generated in nuclear reactions in plasma. 2-D gamma-ray emission measurements give valuable information on the confined alpha particles in DT plasma. They also provide important information on the location of MeV range runaway electron beams in ITER plasma. For all three cases the physical basis and instrumentation are presented. The simple NPA version for measurements of D/T ratio in DEMO is also briefly described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of chemometric models to classify solid-state U materials by micro-Raman spectroscopy

Discerning uranium (U) particles found in environmental sampling is of interest for monitoring the peaceful use of nuclear material. In this study, a soft independent modeling of class analogy (SIMCA) library was successfully developed for the classification of a four-class system consisting of α-U 3 O 8 , UO 2 , UO 2 (NO 3 ) 2 ·6H 2 O (UNH), and UO 2 O 2 ·4H 2 O (studtite) by Raman spectroscopy in the presence of matrix particulates and additional outliers. Spectral variability between numerous particles of each type revealed appreciable differences as a function of particle size with respect to hydration state and potential oxide phase within each class. Interclass variability was accounted for using both unsupervised and supervised chemometric models. The supervised SIMCA model displayed reasonable sensitivity for each U class and a high degree of specificity by returning whether a spectrum belonged to one class or not. This work demonstrates how Raman spectral features and chemometrics can be used to distinguish U materials from one another and from matrix materials such as flint clay. Combining the outlined chemometric approach with Raman mapping sequences could provide a rapid, nondestructive technique to characterize the chemical composition of a diverse collection of U compounds amid background samples for environmental sampling, nuclear forensics, and industrial applications.

Actinide↗

Adaptive Reweighted Variance Estimation for Monte Carlo Eigenvalue Simulations

Monte Carlo (MC) simulation is used to solve the eigenvalue form of the Boltzmann transport equation to estimate various parameters such as fuel pin flux distributions that are crucial for the safe and efficient operation of nuclear systems (e.g., a nuclear reactor). Monte Carlo eigenvalue simulation uses a sample mean over many stationary cycles (iterations) to estimate various parameters important to nuclear systems. A variance estimate of the sample mean is often used for calculating the confidence intervals. However, MC eigenvalue simulation variance estimators that ignore the intercycle correlation underestimate the true variance of the estimated quantity. This paper presents novel data-adaptive approaches based on a simple autoregressive (AR) model and sigmoid functions to improve MC variance estimation. The standard MC sample-based variance estimator (or naïve estimator) and the spectral density–based MC variance estimator are enhanced by adding data-adaptive components that reduce their bias and improve performance. By investigating the frequency pattern of the AR(1) (order 1) model, two adaptive spectral estimators and one adaptive naïve estimator are proposed. The proposed estimators manifest superior performance when applied to three test problems compared to the standard spectral density–based estimator previously introduced by the authors. In conclusion, these new estimators are straightforward, as they use online algorithms and do not require storage of tallies from all active cycles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quasielastic Scattering at MiniBooNE Energies

We present our description of neutrino induced charged current quasielastic scattering (CCQE) in nuclei at energies relevant for the MiniBooNE experiment. In our framework, the nucleons, with initial momentum distributions according to the Local Fermi Gas model, move in a density- and momentum-dependent mean field potential. The broadening of the outgoing nucleons due to nucleon-nucleon interactions is taken into account by spectral functions. Long range (RPA) correlations renormalizing the electroweak strength in the medium are also incorporated. The background from resonance excitation events that do not lead to pions in the final state is also predicted by propagating the outgoing hadrons with the Giessen semiclassical BUU model in coupled channels (GiBUU). We achieve a good description of the shape of the CCQE Q{sup 2} distribution extracted from data by MiniBooNE, thanks to the inclusion of RPA correlations, but underestimate the integrated cross section when the standard value of M{sub A} = 1 GeV is used. Possible reasons for this mismatch are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Power density in direct nuclear-pumped He-3 lasers

The interaction of neutron beams with He-3 gas is of interest for nuclear pumped lasers. The effects of spectral dependence of the neutron beam, neutron attenuation in the gas-filled laser tube, and transport of the charged-particle He-3(n, p)He-3 reaction products are treated in detail. An expression for the energy density as a function of position within the tube, tube radius, operating pressure, and neutron fluence is given. The maximum energy density within the optical cavity is achieved when the tube radius is 3.26/P where P (atm) is the operating pressure. The variation of radius by 50% above and below optimum will change the energy density at most by 10%, although performance degrades quickly for radii outside this range. If the optimum tube radius is used for each operating pressure, then the power density on the centerline (kW/cu cm) is given as 9.3 x 10 to the -18th power times the operating pressure times flux in a thermal neutron environment of flux (n/sq cm sec).

Wilson, J. W.↗

Chi-Nu measurements of the prompt fission neutron spectrum of {sup 235}U and {sup 239}Pu - 25581

Knowledge of the prompt fission neutron spectrum is crucial for understanding the behavior of energetic nuclear systems. Although this energy spectrum has been measured for the major actinides {sup 235}U and {sup 239}Pu for decades, the majority of the available literature data lack the coverage of both incident and outgoing neutron energies and the precision required to accurately guide evaluations and fission models. The Chi-Nu experiment is designed to measure the prompt fission neutron spectrum for a wide range of incident and outgoing neutron energies with attention to uncertainty estimation and assessment of systematic errors in order to provide reliable guidance for evaluations and models of nuclear fission. Preliminary results of the prompt fission neutron spectrum from the neutron-induced fission of {sup 235}U and {sup 239}Pu are presented here, with a focus on the presence of spectral features near multi-chance fission thresholds, pre-equilibrium neutrons in the deduced spectrum, and also on trends of the mean fission neutron energy as a function of the incident neutron energy. While the mean energies of from ENDF/B-VIII.0 are in good agreement with those reported for {sup 235}U spectra, significant disagreements exist above an incident neutron energy of approximately 13 MeV for {sup 239}Pu. Furthermore, in general, the physics features regarding multi-chance fission and pre-equilibrium neutron emission newly-introduced into ENDF/B-VIII.0 appear provide an improved description of the data as compared to ENDF/B-VII.1. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

AGR-1 Irradiation Test Final As-Run Report, Rev 2

This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel process development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 ?1025 n/m2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10-7 with only one capsule significantly exceeding this value. A maximum R/B of around 2?10-7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-1 Irradiation Test Final As-Run Report, Rev. 3

This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel process development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 x 10 25 n/m 2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10 -7 with only one capsule significantly exceeding this value. A maximum R/B of around 2 x 10 -7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-1 Irradiation Test Final As-Run Report

This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel process development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 x 10 25 n/m 2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10 -7 with only one capsule significantly exceeding this value. A maximum R/B of around 2 x 10 -7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New perspective on iron-ligand vibrations of oxyheme complexes.

We report our studies of the vibrational dynamics of iron for three imidazole-ligated oxyheme derivatives that mimic the active sites of histidine-ligated heme proteins complexed with dioxygen. The experimental vibrational data are obtained from nuclear resonance vibrational spectroscopy (NRVS) measurements conducted on both powder samples and oriented single crystals, and which includes several in-plane (ip) and out-of-plane (oop) measurements. Vibrational spectral assignments have been made through a combination of the oriented sample spectra and predictions based on density functional theory (DFT) calculations. The two Fe-O{sub 2} modes that have been previously observed by resonance Raman spectroscopy in heme proteins are clearly shown to be very strongly mixed and are not simply either a bending or stretching mode. In addition, a third Fe-O{sub 2} mode, not previously reported, has been identified. The long-sought Fe-Im stretch, not observed in resonance Raman spectra, has been identified and compared with the frequencies observed for the analogous CO and NO species. The studies also suggest that the in-plane iron motion is anisotropic and is controlled by the orientation of the Fe-O{sub 2} group and not sensitive to the in-plane Fe-N{sub p} bonds and/or imidazole orientations.

59 BASIC BIOLOGICAL SCIENCES↗

THE STAR FORMATION AND NUCLEAR ACCRETION HISTORIES OF NORMAL GALAXIES IN THE AGES SURVEY

We combine IR, optical, and X-ray data from the overlapping, 9.3 deg{sup 2} NOAO Deep Wide-Field Survey, AGN and Galaxy Evolution Survey (AGES), and XBooetes Survey to measure the X-ray evolution of 6146 normal galaxies as a function of absolute optical luminosity, redshift, and spectral type over the largely unexplored redshift range 0.1 {approx}< z {approx}< 0.5. Because only the closest or brightest of the galaxies are individually detected in X-rays, we use a stacking analysis to determine the mean properties of the sample. Our results suggest that X-ray emission from spectroscopically late-type galaxies is dominated by star formation, while that from early-type galaxies is dominated by a combination of hot gas and active galactic nucleus (AGN) emission. We find that the mean star formation and supermassive black hole accretion rate densities evolve like {approx}(1 + z){sup 3{+-}}{sup 1}, in agreement with the trends found for samples of bright, individually detectable starburst galaxies and AGN. Our work also corroborates the results of many previous stacking analyses of faint source populations, with improved statistics.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron Absorber Considerations for the DOE Standardized Canister

The Department of Energy (DOE) standardized canister is being re-evaluated to support the management of non-commercial spent nuclear fuel. The standardized canister would allow a broad range of DOE-managed fuels to be loaded, stored, transported, and disposed of while avoiding the need to re-open the canister after initial loading, thus preventing repackaging of the material. A key safety function of this package is to ensure the material maintains a sub-critical configuration for storage, transportation, and disposal. DOE-managed fuels come from a wide range of reactor types, with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties resulting in a large diversity of reactor and fuel designs. To adequately address the diversity of DOE spent nuclear fuel (SNF), a number of basket were designed. The basket material needed to have the ability to ensure subcriticality, be structurally sound, and be corrosion resistant. One such option that was investigated in the late-1990s through mid-2000s was a corrosion-resistant, nickel-chromium-molybdenum alloy containing gadolinium, which was termed the advanced neutron absorber (ANA). A number of analyses were performed to verify the structural, corrosive properties, and neutron absorption performances of this material as well as to compare other potential materials to be used for the basket. Gadolinium-containing carbon steel and borated stainless steel were also considered and evaluated. Boral was briefly considered, but due to its corrosive properties. Each of the evaluated materials have strengths and weaknesses. ANA is the best thermal neutron absorber but lacks confirmatory research for corrosion and weldability. Gadolinium containing carbon steel provides excellent moderator exclusion capabilities but does not contain a sufficient supply of phosphate to ensure the gadolinium precipitates. To minimize the probability of a critical configuration, it is highly desirable for the gadolinium to precipate the probability that the materials will remain within the waste packages over the postclosure time periods of interest. Borated stainless steel has structural integrity and impressive corrosion resistance in most environments, but can undergo galvanic corrosion when in close proximity/contact with aluminum and may experience less than desirable corrosion resistance. This report provides an extensive list and comparison of the materials evaluated to ensure sub-criticality of DOE standardized canister in all credible scenarios. More analyses need to be performed using new and updated corrosion information to re-evaluate the neutron absorber that best meets the objectives of the DOE standardized canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System Development

We have designed and tested hardware and software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—Osiris—software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,132I. A set of over 100 fission-product spectra was employed for Osiris testing. These spectra were measured, where possible, or generated by modeling. The synthetic test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, Osiris correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.The Osiris gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC Transpec-100, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer was used successfully during the recent 2014 CTBT Integrated Field Exercise in Jordan. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. To date, software development has been the main focus of the Osiris project. In FY2016-17, we plan to modify the Osiris hardware, integrate the Osiris software and hardware, and conduct rigorous field tests to ensure that the Osiris system will function correctly during CTBT on-site inspections. The planned development will raise Osiris to technology readiness level TRL-8; transfer the Osiris technology to a commercial manufacturer, and demonstrate Osiris to potential CTBT on-site inspectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗